{"uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/ocds/record/ocds-03ad3f-443857-1", "publishedDate": "2026-09-13T01:04:43Z", "publisher": {"name": "Direcci\u00f3n Nacional de Contrataciones P\u00fablicas, Paraguay"}, "license": "https://creativecommons.org/licenses/by/4.0/", "publicationPolicy": "https://www.contrataciones.gov.py/datos/legal", "version": "1.1", "extensions": ["https://raw.githubusercontent.com/open-contracting-extensions/ocds_budget_breakdown_extension/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_budget_and_spend_extension/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_lots_extension/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_enquiry_extension/master/extension.json", "https://raw.githubusercontent.com/sdd1982/enquiriesAddress/master/extension.json", "https://raw.githubusercontent.com/sdd1982/legalEntityTypeDetail/master/extension.json", "https://raw.githubusercontent.com/gitMHOCDS/transactions/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_planning_investmentproject_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_clarification_meetings_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_item_attributes_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_planning_items_extension/raw/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_contract_suppliers_extension/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_partyDetails_scale_extension/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_location_extension/v1.1.4/extension.json", "https://gitlab.com/dncp-opendata/ocds_partyDetails_activityType_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_tender_notifiedsuppliers_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_tender_lots_details_extension/raw/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_memberOf_extension/master/extension.json", "https://raw.githubusercontent.com/portaledcahn/ocds_tenderDatePublished_extension/master/extension.json", "https://raw.githubusercontent.com/INAImexico/ocds_guarantees_extension/master/extension.json", "https://bitbucket.org/ONCAETI/ocds_releasesource_extension/raw/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_requirements_extension/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_bidOpening_extension/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_coveredBy_extension/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_qualification_extension/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_partyDetails_publicEntitiesDetails_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_items_subItems_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_statusdetails_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_mainProcurementCategoryDetails_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_planning_identifier_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_planning_estimatedDate_extension/raw/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_participationFee_extension/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_amendments_details_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_lot_details_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_transaction_details_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_contract_financialprogress_financialcode_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_partyDetails_categories_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_complaints_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_item_minQuantity_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_contract_implementation_purchaseOrder_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_document_type_details/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_contract_cancellations_amendments_extension/raw/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_milestone_documents_extension/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_techniques_extension/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_bid_extension/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_bid_items_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_auctions_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_secondStage_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_beneficiaries_extension/raw/master/extension.json", "https://raw.githubusercontent.com/Crown-Commercial-Service/ocds_tender_suitability_extension/main/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_subcontracting_extension/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_partyDetails_scale_extension/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_organizationClassification_extension/master/extension.json", "https://raw.githubusercontent.com/open-contracting-extensions/ocds_sustainability_extension/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_contract_implementation_reportedpayment_extension/raw/master/extension.json", "https://gitlab.com/dncp-opendata/ocds_milestone_deliveries_extension/raw/master/extension.json"], "records": [{"ocid": "ocds-03ad3f-443857-1", "releases": [{"date": "2025-04-14T09:05:39-04:00", "tag": ["tender", "award", "implementation", "contractAmendment", "planningUpdate"], "url": "https://www.contrataciones.gov.py/datos/api/v3/doc/ocds/releases/id/1ef5fba1-ce71-61f8-8818-a11be0626a70-1744621539"}], "compiledRelease": {"id": "1ef5fba1-ce71-61f8-8818-a11be0626a70-1744621539", "awards": [{"id": "1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc", "status": "active", "statusDetails": "publicado", "date": "2024-10-16T00:00:00-04:00", "value": {"amount": 1333285000, "currency": "PYG"}, "suppliers": [{"name": "ALBATROS SACI", "id": "PY-RUC-80002766-3"}], "documents": [{"id": "1ef907c5-a74b-6f6e-b1dc-83a828c23e82", "datePublished": "2024-10-22T10:48:43-04:00", "title": "reso-adj-lpn-21-2024-comp1-6717ad3bcfebb.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/bb615421-b2fb-4f08-a8f9-6cfbb1a8e6b7/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "1ef907c6-252c-66c2-a0f8-8101fb3213b1", "datePublished": "2024-10-22T10:48:57-04:00", "title": "cco-lpn-21-2024-comp1-6717ad4915e58.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/e6b0c92f-e43b-484f-9247-9265eacaeaa6/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef8c721-2715-68ca-b8a6-359fb6476ff3", "datePublished": "2024-10-17T07:25:03-04:00", "title": "cco-lpn-21-2024-6710e5ff5fdc4.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/183e8af1-0475-4ad6-96ae-2ae39582a128/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef907c6-c894-624c-b4af-873b674c807d", "datePublished": "2024-10-22T10:49:14-04:00", "title": "inf-eva-lpn-21-2024-comp1-6717ad5a31d1d.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/4edd617f-8c88-4ff1-9532-93f73879cbce/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "dix2iRRDbik=", "title": "URL de la Adjudicaci\u00f3n", "url": "https://www.contrataciones.gov.py/licitaciones/adjudicacion/1ef8bbaf-a583-61da-88c5-1bed43a37266/resumen-adjudicacion.html", "language": "es", "documentType": "awardNotice", "format": "text/html"}, {"id": "1ef8c722-d10b-6d06-8dd7-fd94b7f65888", "datePublished": "2024-10-17T07:25:48-04:00", "title": "inf-eva-lpn-21-2024-6710e62badd24.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/f635d362-29b8-41e6-8e6f-906512f3cf85/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "1ef8c720-c27c-6aee-90f1-5f2465ebf343", "datePublished": "2024-10-17T07:24:52-04:00", "title": "2268-resol-d-n-1790-adj-lpn-n-21-024-6710e5f4ccaac.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/dad19b6a-f9d0-4c17-9f55-2d712bc71847/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}], "items": [{"id": "1ef66c97-b9cc-6416-9b4c-03138fe681b4", "description": "Caja de Cirugia", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181515-004", "description": "Caja de Cirugia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181515-004"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181515", "description": "Bandejas de examen y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181515"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 140000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9cb-6836-aaf2-03138fe681b4", "attributes": [{"value": "ALEMANIA", "name": "Procedencia", "id": "1"}, {"value": "KARL STORZ SE & CO. KG", "name": "Fabricante", "id": "3"}, {"value": "KARL STORZ", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "7", "id": "7"}]}, {"id": "1ef66c97-b9f7-606c-95e7-03138fe681b4", "description": "Caja de Cirugia General", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9998", "description": "Caja de Cirugia General", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9998"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 17000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9f6-64dc-94f1-03138fe681b4", "attributes": [{"value": "ALEMANIA", "name": "Procedencia", "id": "1"}, {"value": "MEDICON EG.", "name": "Fabricante", "id": "3"}, {"value": "MEDICON", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "15", "id": "7"}]}, {"id": "1ef66c97-ba40-680c-a96f-03138fe681b4", "description": "Caja de Cirugia", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181515-004", "description": "Caja de Cirugia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181515-004"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181515", "description": "Bandejas de examen y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181515"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 47000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba3f-6c40-8ab2-03138fe681b4", "attributes": [{"value": "ALEMANIA", "name": "Procedencia", "id": "1"}, {"value": "KARL STORZ SE & CO. KG", "name": "Fabricante", "id": "3"}, {"value": "KARL STORZ", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "29", "id": "7"}]}, {"id": "1ef66c97-ba4a-6956-aa26-03138fe681b4", "description": "Set para cirugia laparoscopica", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42294805-003", "description": "Set para cirugia laparoscopica", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42294805-003"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42294805", "description": "Laparoscopios o telescopios laparoscopicos", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42294805"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 99500000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba49-6d4e-81da-03138fe681b4", "attributes": [{"value": "ALEMANIA", "name": "Procedencia", "id": "1"}, {"value": "KARL STORZ SE & CO. KG", "name": "Fabricante", "id": "3"}, {"value": "KARL STORZ", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "31", "id": "7"}]}, {"id": "1ef66c97-ba4f-69c4-9d30-03138fe681b4", "description": "Citoscopio", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42294801-034", "description": "Cistoscopio", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42294801-034"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42294801", "description": "Endoscopios o accesorios o productos relacionados", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42294801"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 140000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba4e-6e0c-b76e-03138fe681b4", "attributes": [{"value": "ALEMANIA", "name": "Procedencia", "id": "1"}, {"value": "KARL STORZ SE & CO. KG", "name": "Fabricante", "id": "3"}, {"value": "KARL STORZ", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "32", "id": "7"}]}, {"id": "1ef66c97-ba7d-6310-bfa5-03138fe681b4", "description": "Lampara cialitica con satelite", "classification": {"scheme": "catalogoNivel5DNCP", "id": "39101602-002", "description": "Lampara cialitica con satelite", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/39101602-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "39101602", "description": "Lamparas medicas y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/39101602"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 130000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba7c-6780-a897-03138fe681b4", "attributes": [{"value": "BRASIL", "name": "Procedencia", "id": "1"}, {"value": "BARRFAB INDUSTRIA COMERCIO IMPORTACI\u00d3N EXPORTACI\u00d3N DE EQUIPAMIENTO HOSPITALAR LTDA", "name": "Fabricante", "id": "3"}, {"value": "BARRFAB", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "41", "id": "7"}]}, {"id": "1ef66c97-ba9f-69e2-ad8a-03138fe681b4", "description": "Mesa Quirurgica", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42295108-001", "description": "Mesa Quirurgica", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42295108-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42295108", "description": "Mesas de fractura de paciente de la sala de operacion o mesas ortopedicas o accesorios o productos relacionados", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42295108"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 163200000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba9e-6e20-90ac-03138fe681b4", "attributes": [{"value": "BRASIL", "name": "Procedencia", "id": "1"}, {"value": "BARRFAB INDUSTRIA COMERCIO IMPORTACI\u00d3N EXPORTACI\u00d3N DE EQUIPAMIENTO HOSPITALAR LTD", "name": "Fabricante", "id": "3"}, {"value": "BARRFAB", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "48", "id": "7"}]}, {"id": "1ef66c97-babe-6edc-a80b-03138fe681b4", "description": "Nefroscopio", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42142708-9999", "description": "Nefroscopio", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42142708-9999"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42142708", "description": "Instrumentos urologicos", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42142708"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 115885000, "currency": "PYG"}}, "relatedLot": "1ef66c97-babd-6dca-b3c5-03138fe681b4", "attributes": [{"value": "ALEMANIA", "name": "Procedencia", "id": "1"}, {"value": "KARL STORZ SE & CO. KG", "name": "Fabricante", "id": "3"}, {"value": "KARL STORZ", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "54", "id": "7"}]}, {"id": "1ef66c97-bb50-6be8-b674-03138fe681b4", "description": "Caja de Cirugia Especializada", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9997", "description": "Caja de Cirugia Especializada", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9997"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 187500000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb4f-65ae-8700-03138fe681b4", "attributes": [{"value": "ALEMANIA", "name": "Procedencia", "id": "1"}, {"value": "KARL STORZ SE & CO. KG", "name": "Fabricante", "id": "3"}, {"value": "KARL STORZ", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "67", "id": "7"}]}]}, {"id": "1ef8bbd9-8739-6b0a-9b77-1717c52fda49", "status": "active", "statusDetails": "publicado", "date": "2024-10-16T00:00:00-04:00", "value": {"amount": 172500000, "currency": "PYG"}, "suppliers": [{"name": "ARGON S.R.L.", "id": "PY-RUC-80004373-1"}], "documents": [{"id": "dix2iRRDbik=", "title": "URL de la Adjudicaci\u00f3n", "url": "https://www.contrataciones.gov.py/licitaciones/adjudicacion/1ef8bbaf-a583-61da-88c5-1bed43a37266/resumen-adjudicacion.html", "language": "es", "documentType": "awardNotice", "format": "text/html"}, {"id": "1ef907c5-a74b-6f6e-b1dc-83a828c23e82", "datePublished": "2024-10-22T10:48:43-04:00", "title": "reso-adj-lpn-21-2024-comp1-6717ad3bcfebb.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/bb615421-b2fb-4f08-a8f9-6cfbb1a8e6b7/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "1ef907c6-c894-624c-b4af-873b674c807d", "datePublished": "2024-10-22T10:49:14-04:00", "title": "inf-eva-lpn-21-2024-comp1-6717ad5a31d1d.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/4edd617f-8c88-4ff1-9532-93f73879cbce/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "1ef907c6-252c-66c2-a0f8-8101fb3213b1", "datePublished": "2024-10-22T10:48:57-04:00", "title": "cco-lpn-21-2024-comp1-6717ad4915e58.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/e6b0c92f-e43b-484f-9247-9265eacaeaa6/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef8c720-c27c-6aee-90f1-5f2465ebf343", "datePublished": "2024-10-17T07:24:52-04:00", "title": "2268-resol-d-n-1790-adj-lpn-n-21-024-6710e5f4ccaac.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/dad19b6a-f9d0-4c17-9f55-2d712bc71847/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "1ef8c722-d10b-6d06-8dd7-fd94b7f65888", "datePublished": "2024-10-17T07:25:48-04:00", "title": "inf-eva-lpn-21-2024-6710e62badd24.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/f635d362-29b8-41e6-8e6f-906512f3cf85/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "1ef8c721-2715-68ca-b8a6-359fb6476ff3", "datePublished": "2024-10-17T07:25:03-04:00", "title": "cco-lpn-21-2024-6710e5ff5fdc4.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/183e8af1-0475-4ad6-96ae-2ae39582a128/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}], "items": [{"id": "1ef66c97-baaa-600e-b2f1-03138fe681b4", "description": "Microscopio Optico", "classification": {"scheme": "catalogoNivel5DNCP", "id": "41111710-001", "description": "Microscopio Optico", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/41111710-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "41111710", "description": "Microscopios electronicos y opticos combinados", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/41111710"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 172500000, "currency": "PYG"}}, "relatedLot": "1ef66c97-baa9-6460-89f5-03138fe681b4", "attributes": [{"value": "BRASIL", "name": "Procedencia", "id": "1"}, {"value": "DFV COMERCIAL E INDUSTRIAL LTDA", "name": "Fabricante", "id": "3"}, {"value": "DFV", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "50", "id": "7"}]}]}, {"id": "1ef8bbc8-387e-65ee-8df7-b79c7f8ce3dd", "status": "active", "statusDetails": "publicado", "date": "2024-10-16T00:00:00-04:00", "value": {"amount": 39000000, "currency": "PYG"}, "suppliers": [{"name": "ANDRES H. ARCE SA", "id": "PY-RUC-80023488-0"}], "documents": [{"id": "1ef8c721-2715-68ca-b8a6-359fb6476ff3", "datePublished": "2024-10-17T07:25:03-04:00", "title": "cco-lpn-21-2024-6710e5ff5fdc4.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/183e8af1-0475-4ad6-96ae-2ae39582a128/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "dix2iRRDbik=", "title": "URL de la Adjudicaci\u00f3n", "url": "https://www.contrataciones.gov.py/licitaciones/adjudicacion/1ef8bbaf-a583-61da-88c5-1bed43a37266/resumen-adjudicacion.html", "language": "es", "documentType": "awardNotice", "format": "text/html"}, {"id": "1ef907c6-252c-66c2-a0f8-8101fb3213b1", "datePublished": "2024-10-22T10:48:57-04:00", "title": "cco-lpn-21-2024-comp1-6717ad4915e58.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/e6b0c92f-e43b-484f-9247-9265eacaeaa6/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef8c720-c27c-6aee-90f1-5f2465ebf343", "datePublished": "2024-10-17T07:24:52-04:00", "title": "2268-resol-d-n-1790-adj-lpn-n-21-024-6710e5f4ccaac.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/dad19b6a-f9d0-4c17-9f55-2d712bc71847/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "1ef8c722-d10b-6d06-8dd7-fd94b7f65888", "datePublished": "2024-10-17T07:25:48-04:00", "title": "inf-eva-lpn-21-2024-6710e62badd24.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/f635d362-29b8-41e6-8e6f-906512f3cf85/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "1ef907c6-c894-624c-b4af-873b674c807d", "datePublished": "2024-10-22T10:49:14-04:00", "title": "inf-eva-lpn-21-2024-comp1-6717ad5a31d1d.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/4edd617f-8c88-4ff1-9532-93f73879cbce/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "1ef907c5-a74b-6f6e-b1dc-83a828c23e82", "datePublished": "2024-10-22T10:48:43-04:00", "title": "reso-adj-lpn-21-2024-comp1-6717ad3bcfebb.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/bb615421-b2fb-4f08-a8f9-6cfbb1a8e6b7/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}], "items": [{"id": "1ef702d7-ddd9-6904-a99a-9186720705fb", "description": "Set de Equipos odontologicos", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42151705-001", "description": "Set de Equipos odontologicos ", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42151705-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42151705", "description": "Sets de mobiliario combinado para tratamientos odontologicos", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42151705"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 19500000, "currency": "PYG"}}, "relatedLot": "1ef702d7-ddd8-6680-b15a-9186720705fb", "attributes": [{"value": "CHINA", "name": "Procedencia", "id": "1"}, {"value": "TOYEDENT", "name": "Fabricante", "id": "3"}, {"value": "TOYE", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "60", "id": "7"}]}]}, {"id": "1ef8bca8-b51b-68c8-91a9-592e0c6845ae", "status": "active", "statusDetails": "publicado", "date": "2024-10-16T00:00:00-04:00", "value": {"amount": 311500000, "currency": "PYG"}, "suppliers": [{"name": "IN SITU S.A.", "id": "PY-RUC-80027373-7"}], "documents": [{"id": "1ef907c5-a74b-6f6e-b1dc-83a828c23e82", "datePublished": "2024-10-22T10:48:43-04:00", "title": "reso-adj-lpn-21-2024-comp1-6717ad3bcfebb.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/bb615421-b2fb-4f08-a8f9-6cfbb1a8e6b7/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "1ef8c722-d10b-6d06-8dd7-fd94b7f65888", "datePublished": "2024-10-17T07:25:48-04:00", "title": "inf-eva-lpn-21-2024-6710e62badd24.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/f635d362-29b8-41e6-8e6f-906512f3cf85/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "dix2iRRDbik=", "title": "URL de la Adjudicaci\u00f3n", "url": "https://www.contrataciones.gov.py/licitaciones/adjudicacion/1ef8bbaf-a583-61da-88c5-1bed43a37266/resumen-adjudicacion.html", "language": "es", "documentType": "awardNotice", "format": "text/html"}, {"id": "1ef8c720-c27c-6aee-90f1-5f2465ebf343", "datePublished": "2024-10-17T07:24:52-04:00", "title": "2268-resol-d-n-1790-adj-lpn-n-21-024-6710e5f4ccaac.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/dad19b6a-f9d0-4c17-9f55-2d712bc71847/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "1ef8c721-2715-68ca-b8a6-359fb6476ff3", "datePublished": "2024-10-17T07:25:03-04:00", "title": "cco-lpn-21-2024-6710e5ff5fdc4.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/183e8af1-0475-4ad6-96ae-2ae39582a128/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef907c6-c894-624c-b4af-873b674c807d", "datePublished": "2024-10-22T10:49:14-04:00", "title": "inf-eva-lpn-21-2024-comp1-6717ad5a31d1d.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/4edd617f-8c88-4ff1-9532-93f73879cbce/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "1ef907c6-252c-66c2-a0f8-8101fb3213b1", "datePublished": "2024-10-22T10:48:57-04:00", "title": "cco-lpn-21-2024-comp1-6717ad4915e58.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/e6b0c92f-e43b-484f-9247-9265eacaeaa6/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}], "items": [{"id": "1ef66c97-baf6-6850-a99d-03138fe681b4", "description": "Tabla  para Diseccion", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42261705-999", "description": "Tabla para Diseccion", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42261705-999"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42261705", "description": "Mesas o accesorios de diseccion de animales para autopsia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42261705"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 311500000, "currency": "PYG"}}, "relatedLot": "1ef66c97-baf4-61fe-b041-03138fe681b4", "attributes": [{"value": "CHINA", "name": "Procedencia", "id": "1"}, {"value": "YCZX", "name": "Fabricante", "id": "3"}, {"value": "HUMAN 3D", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "57", "id": "7"}]}]}, {"id": "1ef8bc05-8114-6cda-9693-99740a454274", "status": "active", "statusDetails": "publicado", "date": "2024-10-16T00:00:00-04:00", "value": {"amount": 83579000, "currency": "PYG"}, "suppliers": [{"name": "DYSA HEALTHCARE S.A.", "id": "PY-RUC-80013820-1"}], "documents": [{"id": "1ef907c6-252c-66c2-a0f8-8101fb3213b1", "datePublished": "2024-10-22T10:48:57-04:00", "title": "cco-lpn-21-2024-comp1-6717ad4915e58.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/e6b0c92f-e43b-484f-9247-9265eacaeaa6/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef907c6-c894-624c-b4af-873b674c807d", "datePublished": "2024-10-22T10:49:14-04:00", "title": "inf-eva-lpn-21-2024-comp1-6717ad5a31d1d.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/4edd617f-8c88-4ff1-9532-93f73879cbce/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "dix2iRRDbik=", "title": "URL de la Adjudicaci\u00f3n", "url": "https://www.contrataciones.gov.py/licitaciones/adjudicacion/1ef8bbaf-a583-61da-88c5-1bed43a37266/resumen-adjudicacion.html", "language": "es", "documentType": "awardNotice", "format": "text/html"}, {"id": "1ef8c720-c27c-6aee-90f1-5f2465ebf343", "datePublished": "2024-10-17T07:24:52-04:00", "title": "2268-resol-d-n-1790-adj-lpn-n-21-024-6710e5f4ccaac.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/dad19b6a-f9d0-4c17-9f55-2d712bc71847/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "1ef907c5-a74b-6f6e-b1dc-83a828c23e82", "datePublished": "2024-10-22T10:48:43-04:00", "title": "reso-adj-lpn-21-2024-comp1-6717ad3bcfebb.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/bb615421-b2fb-4f08-a8f9-6cfbb1a8e6b7/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "1ef8c721-2715-68ca-b8a6-359fb6476ff3", "datePublished": "2024-10-17T07:25:03-04:00", "title": "cco-lpn-21-2024-6710e5ff5fdc4.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/183e8af1-0475-4ad6-96ae-2ae39582a128/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef8c722-d10b-6d06-8dd7-fd94b7f65888", "datePublished": "2024-10-17T07:25:48-04:00", "title": "inf-eva-lpn-21-2024-6710e62badd24.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/f635d362-29b8-41e6-8e6f-906512f3cf85/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}], "items": [{"id": "1ef66c97-b9d7-6460-be6a-03138fe681b4", "description": "Caja de Cirugia Menor", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9999", "description": "Caja de Cirugia Menor", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9999"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 19179000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9d6-6772-b15e-03138fe681b4", "attributes": [{"value": "ALEMANIA", "name": "Procedencia", "id": "1"}, {"value": "AS MEDIZINTECHNIK GMBH", "name": "Fabricante", "id": "3"}, {"value": "AS MEDIZINTECHNIK", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "9", "id": "7"}]}, {"id": "1ef66c97-ba01-66e8-8c0e-03138fe681b4", "description": "Caja de Cirugia Pediatrica", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-003", "description": "Caja de cirugia pediatrica", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-003"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 45600000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba00-6b12-a289-03138fe681b4", "attributes": [{"value": "ALEMANIA", "name": "Procedencia", "id": "1"}, {"value": "AS MEDIZINTECHNIK GMBH", "name": "Fabricante", "id": "3"}, {"value": "AS MEDIZINTECHNIK", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "17", "id": "7"}]}, {"id": "1ef66c97-ba45-67f8-bdb5-03138fe681b4", "description": "Caja de Cirugia", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181515-004", "description": "Caja de Cirugia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181515-004"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181515", "description": "Bandejas de examen y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181515"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 18800000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba44-6c36-8d32-03138fe681b4", "attributes": [{"value": "ALEMANIA", "name": "Procedencia", "id": "1"}, {"value": "AS MEDIZINTECHNIK GMBH", "name": "Fabricante", "id": "3"}, {"value": "AS MEDIZINTECHNIK", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "30", "id": "7"}]}]}, {"id": "1ef8bc9e-ca53-6df8-81d6-5539425ca473", "status": "active", "statusDetails": "publicado", "date": "2024-10-16T00:00:00-04:00", "value": {"amount": 477400000, "currency": "PYG"}, "suppliers": [{"name": "SUMI SOCIEDAD ANONIMA", "id": "PY-RUC-80068800-7"}], "documents": [{"id": "1ef8c722-d10b-6d06-8dd7-fd94b7f65888", "datePublished": "2024-10-17T07:25:48-04:00", "title": "inf-eva-lpn-21-2024-6710e62badd24.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/f635d362-29b8-41e6-8e6f-906512f3cf85/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "dix2iRRDbik=", "title": "URL de la Adjudicaci\u00f3n", "url": "https://www.contrataciones.gov.py/licitaciones/adjudicacion/1ef8bbaf-a583-61da-88c5-1bed43a37266/resumen-adjudicacion.html", "language": "es", "documentType": "awardNotice", "format": "text/html"}, {"id": "1ef8c720-c27c-6aee-90f1-5f2465ebf343", "datePublished": "2024-10-17T07:24:52-04:00", "title": "2268-resol-d-n-1790-adj-lpn-n-21-024-6710e5f4ccaac.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/dad19b6a-f9d0-4c17-9f55-2d712bc71847/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "1ef907c5-a74b-6f6e-b1dc-83a828c23e82", "datePublished": "2024-10-22T10:48:43-04:00", "title": "reso-adj-lpn-21-2024-comp1-6717ad3bcfebb.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/bb615421-b2fb-4f08-a8f9-6cfbb1a8e6b7/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "1ef907c6-252c-66c2-a0f8-8101fb3213b1", "datePublished": "2024-10-22T10:48:57-04:00", "title": "cco-lpn-21-2024-comp1-6717ad4915e58.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/e6b0c92f-e43b-484f-9247-9265eacaeaa6/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef8c721-2715-68ca-b8a6-359fb6476ff3", "datePublished": "2024-10-17T07:25:03-04:00", "title": "cco-lpn-21-2024-6710e5ff5fdc4.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/183e8af1-0475-4ad6-96ae-2ae39582a128/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef907c6-c894-624c-b4af-873b674c807d", "datePublished": "2024-10-22T10:49:14-04:00", "title": "inf-eva-lpn-21-2024-comp1-6717ad5a31d1d.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/4edd617f-8c88-4ff1-9532-93f73879cbce/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}], "items": [{"id": "1ef66c97-ba3b-673a-8aaa-03138fe681b4", "description": "Centrifuga", "classification": {"scheme": "catalogoNivel5DNCP", "id": "40161701-001", "description": "Centrifuga ", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/40161701-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "40161701", "description": "Centrifugas de laboratorio y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/40161701"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 4800000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba3a-6a10-9e0c-03138fe681b4", "attributes": [{"value": "CHINA", "name": "Procedencia", "id": "1"}, {"value": "COMPA\u00d1\u00cdA DE INSTRUMENTOS HANGZHOU BOYN, LTD.", "name": "Fabricante", "id": "3"}, {"value": "BOYN", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "28", "id": "7"}]}, {"id": "1ef66c97-ba6d-67c6-a50c-03138fe681b4", "description": "Equipo de rayos X portatil", "classification": {"scheme": "catalogoNivel5DNCP", "id": "41111808-002", "description": "Equipo de rayos X portatil", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/41111808-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "41111808", "description": "Equipo de examen por rayos X y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/41111808"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 450000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba6c-6bf0-8bf9-03138fe681b4", "attributes": [{"value": "JAP\u00d3N", "name": "Procedencia", "id": "1"}, {"value": "SHIMADZU", "name": "Fabricante", "id": "3"}, {"value": "SHIMADZU", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "38", "id": "7"}]}, {"id": "1ef66c97-ba78-60cc-96f9-03138fe681b4", "description": "Estufa de secado", "classification": {"scheme": "catalogoNivel5DNCP", "id": "41104506-003", "description": "Estufa de secado", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/41104506-003"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "41104506", "description": "Estufas de seguridad de laboratorio", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/41104506"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 11300000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba77-6474-a7a4-03138fe681b4", "attributes": [{"value": "CHINA", "name": "Procedencia", "id": "1"}, {"value": "COMPA\u00d1\u00cdA DE INSTRUMENTOS HANGZHOU BOYN, LTD.", "name": "Fabricante", "id": "3"}, {"value": "BOYN", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "40", "id": "7"}]}]}, {"id": "1ef8bc53-1543-618e-9005-ab792174d300", "status": "active", "statusDetails": "publicado", "date": "2024-10-16T00:00:00-04:00", "value": {"amount": 5571514000, "currency": "PYG"}, "suppliers": [{"name": "LCM SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80011068-4"}], "documents": [{"id": "1ef8c721-2715-68ca-b8a6-359fb6476ff3", "datePublished": "2024-10-17T07:25:03-04:00", "title": "cco-lpn-21-2024-6710e5ff5fdc4.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/183e8af1-0475-4ad6-96ae-2ae39582a128/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef8c720-c27c-6aee-90f1-5f2465ebf343", "datePublished": "2024-10-17T07:24:52-04:00", "title": "2268-resol-d-n-1790-adj-lpn-n-21-024-6710e5f4ccaac.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/dad19b6a-f9d0-4c17-9f55-2d712bc71847/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "1ef8c722-d10b-6d06-8dd7-fd94b7f65888", "datePublished": "2024-10-17T07:25:48-04:00", "title": "inf-eva-lpn-21-2024-6710e62badd24.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/f635d362-29b8-41e6-8e6f-906512f3cf85/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "1ef907c6-252c-66c2-a0f8-8101fb3213b1", "datePublished": "2024-10-22T10:48:57-04:00", "title": "cco-lpn-21-2024-comp1-6717ad4915e58.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/e6b0c92f-e43b-484f-9247-9265eacaeaa6/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef907c5-a74b-6f6e-b1dc-83a828c23e82", "datePublished": "2024-10-22T10:48:43-04:00", "title": "reso-adj-lpn-21-2024-comp1-6717ad3bcfebb.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/bb615421-b2fb-4f08-a8f9-6cfbb1a8e6b7/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "1ef907c6-c894-624c-b4af-873b674c807d", "datePublished": "2024-10-22T10:49:14-04:00", "title": "inf-eva-lpn-21-2024-comp1-6717ad5a31d1d.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/4edd617f-8c88-4ff1-9532-93f73879cbce/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "dix2iRRDbik=", "title": "URL de la Adjudicaci\u00f3n", "url": "https://www.contrataciones.gov.py/licitaciones/adjudicacion/1ef8bbaf-a583-61da-88c5-1bed43a37266/resumen-adjudicacion.html", "language": "es", "documentType": "awardNotice", "format": "text/html"}], "items": [{"id": "1ef66c97-b9a9-6c22-9d7a-03138fe681b4", "description": "Aspirador de Secreciones ", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42271907-001", "description": "Aspirador de secreciones", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42271907-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42271907", "description": "Productos o accesorios de aspirador respiratorio", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42271907"}], "quantity": 4, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 12900000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9a8-6354-903d-03138fe681b4", "attributes": [{"value": " BRASIL", "name": "Procedencia", "id": "1"}, {"value": " FANEM LTD", "name": "Fabricante", "id": "3"}, {"value": " FANEM", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "1", "id": "7"}]}, {"id": "1ef66c97-b9b5-6928-9d05-03138fe681b4", "description": "Balanza pediatrica", "classification": {"scheme": "catalogoNivel5DNCP", "id": "41111508-002", "description": "Balanza pediatrica", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/41111508-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "41111508", "description": "Basculas de medicion del peso corporal", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/41111508"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 1800000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9b4-6a96-89b0-03138fe681b4", "attributes": [{"value": " BRASIL", "name": "Procedencia", "id": "1"}, {"value": " BALMAK", "name": "Fabricante", "id": "3"}, {"value": " BALMAK", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "3", "id": "7"}]}, {"id": "1ef66c97-b9c0-6bf2-aa8e-03138fe681b4", "description": "Caja de Cirugia especializada", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9997", "description": "Caja de Cirugia Especializada", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9997"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 5, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 864000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9bf-6f2c-bf46-03138fe681b4", "attributes": [{"value": " PAKISTAN", "name": "Procedencia", "id": "1"}, {"value": " AKHYAR SURGICAL PROFFESSIONAL ", "name": "Fabricante", "id": "3"}, {"value": " ASP", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "5", "id": "7"}]}, {"id": "1ef66c97-b9c6-6cb4-8925-03138fe681b4", "description": "Caja de Cirugia General", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9998", "description": "Caja de Cirugia General", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9998"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 3, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 19658000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9c5-6fc6-b6d0-03138fe681b4", "attributes": [{"value": " PAKISTAN", "name": "Procedencia", "id": "1"}, {"value": " AKHYAR SURGICAL PROFFESSIONAL ", "name": "Fabricante", "id": "3"}, {"value": " ASP", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "6", "id": "7"}]}, {"id": "1ef66c97-b9d1-6dbc-9a79-03138fe681b4", "description": "Caja de Cirugia Menor", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9999", "description": "Caja de Cirugia Menor", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9999"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 5, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 2440000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9d0-6ed0-a4fa-03138fe681b4", "attributes": [{"value": " PAKISTAN", "name": "Procedencia", "id": "1"}, {"value": " AKHYAR SURGICAL PROFFESSIONAL ", "name": "Fabricante", "id": "3"}, {"value": " ASP", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "8", "id": "7"}]}, {"id": "1ef66c97-b9e2-627a-ac07-03138fe681b4", "description": "Caja de Cirugia especializada", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9997", "description": "Caja de Cirugia Especializada", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9997"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 28540000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9e1-66a4-a72d-03138fe681b4", "attributes": [{"value": " PAKISTAN", "name": "Procedencia", "id": "1"}, {"value": " AKHYAR SURGICAL PROFFESSIONAL ", "name": "Fabricante", "id": "3"}, {"value": " ASP", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "11", "id": "7"}]}, {"id": "1ef66c97-b9e7-65a4-9a99-03138fe681b4", "description": "Caja de Cirugia especializada", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9997", "description": "Caja de Cirugia Especializada", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9997"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 29400000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9e6-6622-8433-03138fe681b4", "attributes": [{"value": " ALEMANIA", "name": "Procedencia", "id": "1"}, {"value": " REDA INSTRUMENTE GMB", "name": "Fabricante", "id": "3"}, {"value": " REDA", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "12", "id": "7"}]}, {"id": "1ef66c97-b9ec-696e-b6b6-03138fe681b4", "description": "Caja de Cirugia", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181515-004", "description": "Caja de Cirugia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181515-004"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181515", "description": "Bandejas de examen y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181515"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 7800000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9eb-6a6e-81a3-03138fe681b4", "attributes": [{"value": " PAKISTAN", "name": "Procedencia", "id": "1"}, {"value": " AKHYAR SURGICAL PROFFESSIONAL ", "name": "Fabricante", "id": "3"}, {"value": " ASP", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "13", "id": "7"}]}, {"id": "1ef66c97-b9f2-6184-91c2-03138fe681b4", "description": "Caja de Cirugia General", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9998", "description": "Caja de Cirugia General", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9998"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 15000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9f1-6496-9f22-03138fe681b4", "attributes": [{"value": " ALEMANIA", "name": "Procedencia", "id": "1"}, {"value": " REDA INSTRUMENTE GMB", "name": "Fabricante", "id": "3"}, {"value": " REDA", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "14", "id": "7"}]}, {"id": "1ef66c97-b9fc-6328-a8e9-03138fe681b4", "description": "Monitor multiparametrico", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181904-002", "description": "Monitor multiparametrico", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181904-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181904", "description": "Unidades de transporte o de senales vitales moviles de multiparametro o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181904"}], "quantity": 6, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 95000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9fb-6748-90c8-03138fe681b4", "attributes": [{"value": " JAPON", "name": "Procedencia", "id": "1"}, {"value": " NIHON KOHDEN CORPORATION ", "name": "Fabricante", "id": "3"}, {"value": " NIHON KOHDEN", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "16", "id": "7"}]}, {"id": "1ef66c97-ba06-6788-848c-03138fe681b4", "description": "Caja de traumatologia y ortopedia", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-002", "description": "Caja de traumatologia y ortopedia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 62270000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba05-6b30-96b2-03138fe681b4", "attributes": [{"value": " ALEMANIA", "name": "Procedencia", "id": "1"}, {"value": " REDA INSTRUMENTE GMB", "name": "Fabricante", "id": "3"}, {"value": " REDA", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "18", "id": "7"}]}, {"id": "1ef66c97-ba0b-64e0-8189-03138fe681b4", "description": "Caja de curacion", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181515-002", "description": "Caja de curacion", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181515-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181515", "description": "Bandejas de examen y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181515"}], "quantity": 10, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 1860000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba0a-68ba-9cca-03138fe681b4", "attributes": [{"value": " PAKISTAN", "name": "Procedencia", "id": "1"}, {"value": " AKHYAR SURGICAL PROFFESSIONAL ", "name": "Fabricante", "id": "3"}, {"value": " ASP", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "19", "id": "7"}]}, {"id": "1ef66c97-ba10-6df0-8b3f-03138fe681b4", "description": "Cama electrica para paciente", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42191807-001", "description": "Cama electrica para paciente", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42191807-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42191807", "description": "Camas de cuidado del paciente o accesorios de uso general", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42191807"}], "quantity": 14, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 39000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba0f-6f68-a733-03138fe681b4", "attributes": [{"value": " CHINA", "name": "Procedencia", "id": "1"}, {"value": " JIANGSU SAIKANG MEDICAL EQUIPMENT CO. LTD", "name": "Fabricante", "id": "3"}, {"value": " JIANGSU SAIKANG", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "20", "id": "7"}]}, {"id": "1ef66c97-ba16-66f6-a709-03138fe681b4", "description": "Cama electrica para paciente", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42191807-001", "description": "Cama electrica para paciente", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42191807-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42191807", "description": "Camas de cuidado del paciente o accesorios de uso general", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42191807"}], "quantity": 9, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 9200000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba15-6a62-99c8-03138fe681b4", "attributes": [{"value": " CHINA", "name": "Procedencia", "id": "1"}, {"value": " JIANGSU SAIKANG MEDICAL EQUIPMENT CO. LTD", "name": "Fabricante", "id": "3"}, {"value": " JIANGSU SAIKANG", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "21", "id": "7"}]}, {"id": "1ef66c97-ba1b-6912-ad01-03138fe681b4", "description": "Camilla fija", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42192207-005", "description": "Camilla fija", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42192207-005"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42192207", "description": "Camillas de paciente o accesorios de camilla", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42192207"}], "quantity": 9, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 2500000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba1a-6c24-a5b3-03138fe681b4", "attributes": [{"value": " NACIONAL", "name": "Procedencia", "id": "1"}, {"value": " LCM S.A.", "name": "Fabricante", "id": "3"}, {"value": " MEDIMUEBLE", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "22", "id": "7"}]}, {"id": "1ef66c97-ba20-6ed0-baf2-03138fe681b4", "description": "Camilla con ruedas", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42192207-001", "description": "Camilla con ruedas", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42192207-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42192207", "description": "Camillas de paciente o accesorios de camilla", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42192207"}], "quantity": 5, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 4140000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba20-6296-be3b-03138fe681b4", "attributes": [{"value": " CHINA", "name": "Procedencia", "id": "1"}, {"value": " JIANGSU SAIKANG MEDICAL EQUIPMENT CO. LTD", "name": "Fabricante", "id": "3"}, {"value": " JIANGSU SAIKANG", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "23", "id": "7"}]}, {"id": "1ef66c97-ba26-627c-bd37-03138fe681b4", "description": "Cardiodesfibrilador", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42172101-003", "description": "Cardiodesfibrilador", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42172101-003"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42172101", "description": "Desfibriladores externos automatizados (AED) o paletas rigidas", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42172101"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 88495000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba25-661a-b623-03138fe681b4", "attributes": [{"value": " JAPON", "name": "Procedencia", "id": "1"}, {"value": " NIHON KOHDEN CORPORATION ", "name": "Fabricante", "id": "3"}, {"value": " NIHON KOHDEN", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "24", "id": "7"}]}, {"id": "1ef66c97-ba2b-6182-bcf8-03138fe681b4", "description": "Cardiodesfibrilador", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42172101-003", "description": "Cardiodesfibrilador", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42172101-003"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42172101", "description": "Desfibriladores externos automatizados (AED) o paletas rigidas", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42172101"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 74995000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba2a-6566-b221-03138fe681b4", "attributes": [{"value": " JAPON", "name": "Procedencia", "id": "1"}, {"value": " NIHON KOHDEN CORPORATION ", "name": "Fabricante", "id": "3"}, {"value": " NIHON KOHDEN", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "25", "id": "7"}]}, {"id": "1ef66c97-ba30-65ce-902c-03138fe681b4", "description": "Carro de paro", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42172101-004", "description": "Carro de paro", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42172101-004"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42172101", "description": "Desfibriladores externos automatizados (AED) o paletas rigidas", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42172101"}], "quantity": 6, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 9900000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba2f-69f8-a99d-03138fe681b4", "attributes": [{"value": " CHINA", "name": "Procedencia", "id": "1"}, {"value": " JIANGSU SAIKANG MEDICAL EQUIPMENT CO. LTD", "name": "Fabricante", "id": "3"}, {"value": " JIANGSU SAIKANG", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "26", "id": "7"}]}, {"id": "1ef66c97-ba35-6a7e-b968-03138fe681b4", "description": "Carro para curaciones", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42192404-001", "description": "Carro para curaciones", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42192404-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42192404", "description": "Carros medicos o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42192404"}], "quantity": 4, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 1760000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba34-6e08-9fbf-03138fe681b4", "attributes": [{"value": " NACIONAL", "name": "Procedencia", "id": "1"}, {"value": " LCM S.A.", "name": "Fabricante", "id": "3"}, {"value": " MEDIMUEBLE", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "27", "id": "7"}]}, {"id": "1ef66c97-ba63-61b8-8ef3-03138fe681b4", "description": "Electrocardiografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181716-001", "description": "Electrocardiografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181716-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181716", "description": "Electrocardiografia (ECG) y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181716"}], "quantity": 6, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 21000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba62-65b0-b112-03138fe681b4", "attributes": [{"value": " JAPON", "name": "Procedencia", "id": "1"}, {"value": " NIHON KOHDEN CORPORATION ", "name": "Fabricante", "id": "3"}, {"value": " NIHON KOHDEN", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "36", "id": "7"}]}, {"id": "1ef66c97-ba82-600e-a2e0-03138fe681b4", "description": "Ventilador pulmonar de alta complejidad", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42272207-001", "description": "Ventilador pulmonar de alta complejidad", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42272207-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42272207", "description": "Ventiladores de alta frecuencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42272207"}], "quantity": 4, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 350000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba81-63de-a101-03138fe681b4", "attributes": [{"value": " ESTADOS UNIDOS", "name": "Procedencia", "id": "1"}, {"value": " NIHON KOHDEN ORANGEMED INC ", "name": "Fabricante", "id": "3"}, {"value": " NIHON KOHDEN", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "42", "id": "7"}]}, {"id": "1ef66c97-ba86-6c4e-a6e0-03138fe681b4", "description": "Laringoscopio Adulto", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42272001-002", "description": "Laringoscopio Adulto", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42272001-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42272001", "description": "Laringoscopios o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42272001"}], "quantity": 8, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 2417000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba86-6096-88a5-03138fe681b4", "attributes": [{"value": " PAKISTAN", "name": "Procedencia", "id": "1"}, {"value": " AKHYAR SURGICAL PROFFESSIONAL ", "name": "Fabricante", "id": "3"}, {"value": " ASP", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "43", "id": "7"}]}, {"id": "1ef66c97-ba8b-6ee2-9a2f-03138fe681b4", "description": "Maquina de anestesia", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42272504-007", "description": "Maquina de anestesia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42272504-007"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42272504", "description": "Equipos para anestesia y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42272504"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 434070000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba8b-6276-9db9-03138fe681b4", "attributes": [{"value": " BELGICA", "name": "Procedencia", "id": "1"}, {"value": " MEDEC INTERNATIONAL BV", "name": "Fabricante", "id": "3"}, {"value": " MEDEC", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "44", "id": "7"}]}, {"id": "1ef66c97-ba90-694c-86ab-03138fe681b4", "description": "Maquina de anestesia", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42272504-007", "description": "Maquina de anestesia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42272504-007"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42272504", "description": "Equipos para anestesia y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42272504"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 463200000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba8f-6dd0-9052-03138fe681b4", "attributes": [{"value": " BELGICA", "name": "Procedencia", "id": "1"}, {"value": " MEDEC INTERNATIONAL BV", "name": "Fabricante", "id": "3"}, {"value": " MEDEC", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "45", "id": "7"}]}, {"id": "1ef66c97-ba95-6b90-a3dc-03138fe681b4", "description": "Mesa de instrumental ", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42295112-002", "description": "Mesa de instrumental", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42295112-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42295112", "description": "Mesas de procedimiento de la sala de operacion o accesorios o productos relacionados", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42295112"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 1469000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba94-6fba-aac5-03138fe681b4", "attributes": [{"value": " CHINA", "name": "Procedencia", "id": "1"}, {"value": " JIANGSU SAIKANG MEDICAL EQUIPMENT CO. LTD", "name": "Fabricante", "id": "3"}, {"value": " JIANGSU SAIKANG", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "46", "id": "7"}]}, {"id": "1ef66c97-ba9a-6a3c-922f-03138fe681b4", "description": "Mesa de Instrumental", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42295112-002", "description": "Mesa de instrumental", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42295112-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42295112", "description": "Mesas de procedimiento de la sala de operacion o accesorios o productos relacionados", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42295112"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 3200000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba99-6e70-99a5-03138fe681b4", "attributes": [{"value": " NACIONAL", "name": "Procedencia", "id": "1"}, {"value": " LCM S.A.", "name": "Fabricante", "id": "3"}, {"value": " MEDIMUEBLE", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "47", "id": "7"}]}, {"id": "1ef66c97-baa4-6b86-b156-03138fe681b4", "description": "Mesita de apoyo de cabecera / alimentacion del paciente", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42191901-001", "description": "Mesita de apoyo de cabecera / alimentacion del paciente", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42191901-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42191901", "description": "Muebles clinicos de cabecera o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42191901"}], "quantity": 9, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 1100000, "currency": "PYG"}}, "relatedLot": "1ef66c97-baa3-6fec-bf9d-03138fe681b4", "attributes": [{"value": " NACIONAL", "name": "Procedencia", "id": "1"}, {"value": " LCM S.A.", "name": "Fabricante", "id": "3"}, {"value": " MEDIMUEBLE", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "49", "id": "7"}]}, {"id": "1ef66c97-bab4-6626-9601-03138fe681b4", "description": "Monitor cardiofetal", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181901-001", "description": "Monitor cardiofetal", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181901-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181901", "description": "Unidades de monitorizacion materna o fetal de tratamiento agudo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181901"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 15600000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bab3-6a32-8e42-03138fe681b4", "attributes": [{"value": " KOREA", "name": "Procedencia", "id": "1"}, {"value": " BISTOS CO. LTD", "name": "Fabricante", "id": "3"}, {"value": " BISTOS", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "52", "id": "7"}]}, {"id": "1ef66c97-bab9-6522-ba16-03138fe681b4", "description": "Monitor multiparametrico", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181904-002", "description": "Monitor multiparametrico", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181904-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181904", "description": "Unidades de transporte o de senales vitales moviles de multiparametro o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181904"}], "quantity": 17, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 30000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bab8-6884-80fb-03138fe681b4", "attributes": [{"value": " KOREA", "name": "Procedencia", "id": "1"}, {"value": " BISTOS CO. LTD", "name": "Fabricante", "id": "3"}, {"value": " BISTOS", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "53", "id": "7"}]}, {"id": "1ef66c97-bad2-6af4-ac65-03138fe681b4", "description": "Porta suero", "classification": {"scheme": "catalogoNivel5DNCP", "id": "41123403-003", "description": "Porta suero", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/41123403-003"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "41123403", "description": "Goteros de dosificacion y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/41123403"}], "quantity": 20, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 380000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bace-63fa-a271-03138fe681b4", "attributes": [{"value": " NACIONAL", "name": "Procedencia", "id": "1"}, {"value": " LCM S.A.", "name": "Fabricante", "id": "3"}, {"value": " MEDIMUEBLE", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "55", "id": "7"}]}, {"id": "1ef66c97-bae5-6e10-abc9-03138fe681b4", "description": "Incubadora  Servocuna", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42191802-9999", "description": "Incubadora + Servocuna", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42191802-9999"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42191802", "description": "Incubadoras clinicas o calentadores de bebe y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42191802"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 250000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bae2-6c74-8406-03138fe681b4", "attributes": [{"value": " BRASIL", "name": "Procedencia", "id": "1"}, {"value": " FANEM LTD", "name": "Fabricante", "id": "3"}, {"value": " FANEM", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "56", "id": "7"}]}, {"id": "1ef66c97-bb02-6bf0-8b0c-03138fe681b4", "description": "Silla de rueda plegable", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42192210-001", "description": "Silla de rueda plegable", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42192210-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42192210", "description": "Sillas de ruedas", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42192210"}], "quantity": 20, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 1100000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb00-6792-9037-03138fe681b4", "attributes": [{"value": " CHINA", "name": "Procedencia", "id": "1"}, {"value": " JIANGSU INTCO MEDICAL PRODUCTS CO. LTD", "name": "Fabricante", "id": "3"}, {"value": " INTCO", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "58", "id": "7"}]}, {"id": "1ef66c97-bb0d-697e-a323-03138fe681b4", "description": "Silla Sanitaria", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42192103-9999", "description": "Silla Sanitaria", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42192103-9999"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42192103", "description": "Sillas de paciente", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42192103"}], "quantity": 6, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 590000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb0b-6d04-9d2f-03138fe681b4", "attributes": [{"value": " CHINA", "name": "Procedencia", "id": "1"}, {"value": " JIANGSU INTCO MEDICAL PRODUCTS CO. LTD", "name": "Fabricante", "id": "3"}, {"value": " INTCO", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "59", "id": "7"}]}]}, {"id": "1ef8f9ac-dd29-6e46-8b90-1930e52a79ef", "status": "active", "statusDetails": "publicado", "date": "2024-10-21T00:00:00-04:00", "value": {"amount": 98268596, "currency": "PYG"}, "suppliers": [{"name": "CATETERES Y AFINES S.A.", "id": "PY-RUC-80030030-0"}], "documents": [{"id": "1ef8c721-2715-68ca-b8a6-359fb6476ff3", "datePublished": "2024-10-17T07:25:03-04:00", "title": "cco-lpn-21-2024-6710e5ff5fdc4.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/183e8af1-0475-4ad6-96ae-2ae39582a128/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef907c6-c894-624c-b4af-873b674c807d", "datePublished": "2024-10-22T10:49:14-04:00", "title": "inf-eva-lpn-21-2024-comp1-6717ad5a31d1d.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/4edd617f-8c88-4ff1-9532-93f73879cbce/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "1ef8c720-c27c-6aee-90f1-5f2465ebf343", "datePublished": "2024-10-17T07:24:52-04:00", "title": "2268-resol-d-n-1790-adj-lpn-n-21-024-6710e5f4ccaac.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/dad19b6a-f9d0-4c17-9f55-2d712bc71847/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "1ef8c722-d10b-6d06-8dd7-fd94b7f65888", "datePublished": "2024-10-17T07:25:48-04:00", "title": "inf-eva-lpn-21-2024-6710e62badd24.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/f635d362-29b8-41e6-8e6f-906512f3cf85/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "dix2iRRDbik=", "title": "URL de la Adjudicaci\u00f3n", "url": "https://www.contrataciones.gov.py/licitaciones/adjudicacion/1ef8bbaf-a583-61da-88c5-1bed43a37266/resumen-adjudicacion.html", "language": "es", "documentType": "awardNotice", "format": "text/html"}, {"id": "1ef907c5-a74b-6f6e-b1dc-83a828c23e82", "datePublished": "2024-10-22T10:48:43-04:00", "title": "reso-adj-lpn-21-2024-comp1-6717ad3bcfebb.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/bb615421-b2fb-4f08-a8f9-6cfbb1a8e6b7/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "1ef907c6-252c-66c2-a0f8-8101fb3213b1", "datePublished": "2024-10-22T10:48:57-04:00", "title": "cco-lpn-21-2024-comp1-6717ad4915e58.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/e6b0c92f-e43b-484f-9247-9265eacaeaa6/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}], "items": [{"id": "1ef66c97-b9dc-6b40-9ec9-03138fe681b4", "description": "Caja de Cirugia especializada", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9997", "description": "Caja de Cirugia Especializada", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9997"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 98268596, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9db-6bb4-bed9-03138fe681b4", "attributes": [{"value": "ALEMANIA", "name": "Procedencia", "id": "1"}, {"value": "NOPA INSTRUMENTS MEDIZINTECHNIK GMBH", "name": "Fabricante", "id": "3"}, {"value": "NOPA", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "10", "id": "7"}]}]}, {"id": "1ef8bc90-a11a-663e-b2d6-79cf5a5a412f", "status": "active", "statusDetails": "publicado", "date": "2024-10-16T00:00:00-04:00", "value": {"amount": 382400000, "currency": "PYG"}, "suppliers": [{"name": "SOLUMEDIC S.A.", "id": "PY-RUC-80023913-0"}], "documents": [{"id": "1ef8c722-d10b-6d06-8dd7-fd94b7f65888", "datePublished": "2024-10-17T07:25:48-04:00", "title": "inf-eva-lpn-21-2024-6710e62badd24.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/f635d362-29b8-41e6-8e6f-906512f3cf85/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "1ef907c6-c894-624c-b4af-873b674c807d", "datePublished": "2024-10-22T10:49:14-04:00", "title": "inf-eva-lpn-21-2024-comp1-6717ad5a31d1d.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/4edd617f-8c88-4ff1-9532-93f73879cbce/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "1ef907c5-a74b-6f6e-b1dc-83a828c23e82", "datePublished": "2024-10-22T10:48:43-04:00", "title": "reso-adj-lpn-21-2024-comp1-6717ad3bcfebb.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/bb615421-b2fb-4f08-a8f9-6cfbb1a8e6b7/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "dix2iRRDbik=", "title": "URL de la Adjudicaci\u00f3n", "url": "https://www.contrataciones.gov.py/licitaciones/adjudicacion/1ef8bbaf-a583-61da-88c5-1bed43a37266/resumen-adjudicacion.html", "language": "es", "documentType": "awardNotice", "format": "text/html"}, {"id": "1ef8c721-2715-68ca-b8a6-359fb6476ff3", "datePublished": "2024-10-17T07:25:03-04:00", "title": "cco-lpn-21-2024-6710e5ff5fdc4.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/183e8af1-0475-4ad6-96ae-2ae39582a128/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef907c6-252c-66c2-a0f8-8101fb3213b1", "datePublished": "2024-10-22T10:48:57-04:00", "title": "cco-lpn-21-2024-comp1-6717ad4915e58.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/e6b0c92f-e43b-484f-9247-9265eacaeaa6/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef8c720-c27c-6aee-90f1-5f2465ebf343", "datePublished": "2024-10-17T07:24:52-04:00", "title": "2268-resol-d-n-1790-adj-lpn-n-21-024-6710e5f4ccaac.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/dad19b6a-f9d0-4c17-9f55-2d712bc71847/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}], "items": [{"id": "1ef66c97-ba5e-612c-8b0a-03138fe681b4", "description": "Ecografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42201718-001", "description": "Ecografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42201718-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42201718", "description": "Ecografos y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42201718"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 234600000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba5d-657e-a55b-03138fe681b4", "attributes": [{"value": "USA", "name": "Procedencia", "id": "1"}, {"value": "GENERAL ELECTRIC", "name": "Fabricante", "id": "3"}, {"value": "GENERAL ELECTRIC", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "35", "id": "7"}]}, {"id": "1ef66c97-bb20-6240-9b8c-03138fe681b4", "description": "Sistema de Monitorizacion Holter", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181713-9999", "description": "Sistema de Monitorizacion Holter", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181713-9999"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181713", "description": "Sistemas de monitorizacion Holter", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181713"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 12500000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb1e-690e-b0a4-03138fe681b4", "attributes": [{"value": "CHINA", "name": "Procedencia", "id": "1"}, {"value": "EDAN INSTRUMENTS INC.", "name": "Fabricante", "id": "3"}, {"value": "EDAN", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "61", "id": "7"}]}, {"id": "1ef66c97-bb28-6896-823f-03138fe681b4", "description": "Transductor para ecografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42201711-001", "description": "Transductor para ecografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42201711-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42201711", "description": "Transductores ecograficos medicos de ultrasonidos, efecto Doppler o eco, o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42201711"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 40750000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb27-63a6-89c4-03138fe681b4", "attributes": [{"value": "USA", "name": "Procedencia", "id": "1"}, {"value": "GENERAL ELECTRIC", "name": "Fabricante", "id": "3"}, {"value": "GENERAL ELECTRIC", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "62", "id": "7"}]}, {"id": "1ef66c97-bb30-6780-933f-03138fe681b4", "description": "Transductor para ecografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42201711-001", "description": "Transductor para ecografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42201711-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42201711", "description": "Transductores ecograficos medicos de ultrasonidos, efecto Doppler o eco, o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42201711"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 41300000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb2f-601a-93dd-03138fe681b4", "attributes": [{"value": "USA", "name": "Procedencia", "id": "1"}, {"value": "GENERAL ELECTRIC", "name": "Fabricante", "id": "3"}, {"value": "GENERAL ELECTRIC", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "63", "id": "7"}]}, {"id": "1ef66c97-bb38-6aa2-a29f-03138fe681b4", "description": "Transductor para ecografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42201711-001", "description": "Transductor para ecografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42201711-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42201711", "description": "Transductores ecograficos medicos de ultrasonidos, efecto Doppler o eco, o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42201711"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 40750000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb37-622e-9c94-03138fe681b4", "attributes": [{"value": "USA", "name": "Procedencia", "id": "1"}, {"value": "GENERAL ELECTRIC", "name": "Fabricante", "id": "3"}, {"value": "GENERAL ELECTRIC", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "64", "id": "7"}]}]}, {"id": "1ef8bc48-e024-6dae-8bb2-09ffc38db45b", "status": "active", "statusDetails": "publicado", "date": "2024-10-16T00:00:00-04:00", "value": {"amount": 796000000, "currency": "PYG"}, "suppliers": [{"name": "IMESE S.A.", "id": "PY-RUC-80016426-1"}], "documents": [{"id": "1ef907c6-c894-624c-b4af-873b674c807d", "datePublished": "2024-10-22T10:49:14-04:00", "title": "inf-eva-lpn-21-2024-comp1-6717ad5a31d1d.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/4edd617f-8c88-4ff1-9532-93f73879cbce/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "1ef907c5-a74b-6f6e-b1dc-83a828c23e82", "datePublished": "2024-10-22T10:48:43-04:00", "title": "reso-adj-lpn-21-2024-comp1-6717ad3bcfebb.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/bb615421-b2fb-4f08-a8f9-6cfbb1a8e6b7/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "1ef8c720-c27c-6aee-90f1-5f2465ebf343", "datePublished": "2024-10-17T07:24:52-04:00", "title": "2268-resol-d-n-1790-adj-lpn-n-21-024-6710e5f4ccaac.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/dad19b6a-f9d0-4c17-9f55-2d712bc71847/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "dix2iRRDbik=", "title": "URL de la Adjudicaci\u00f3n", "url": "https://www.contrataciones.gov.py/licitaciones/adjudicacion/1ef8bbaf-a583-61da-88c5-1bed43a37266/resumen-adjudicacion.html", "language": "es", "documentType": "awardNotice", "format": "text/html"}, {"id": "1ef907c6-252c-66c2-a0f8-8101fb3213b1", "datePublished": "2024-10-22T10:48:57-04:00", "title": "cco-lpn-21-2024-comp1-6717ad4915e58.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/e6b0c92f-e43b-484f-9247-9265eacaeaa6/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef8c721-2715-68ca-b8a6-359fb6476ff3", "datePublished": "2024-10-17T07:25:03-04:00", "title": "cco-lpn-21-2024-6710e5ff5fdc4.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/183e8af1-0475-4ad6-96ae-2ae39582a128/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef8c722-d10b-6d06-8dd7-fd94b7f65888", "datePublished": "2024-10-17T07:25:48-04:00", "title": "inf-eva-lpn-21-2024-6710e62badd24.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/f635d362-29b8-41e6-8e6f-906512f3cf85/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}], "items": [{"id": "1ef66c97-ba54-6744-b576-03138fe681b4", "description": "Ecocardiografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181716-002", "description": "Ecocardiografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181716-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181716", "description": "Electrocardiografia (ECG) y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181716"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 420000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba53-6b96-a2c5-03138fe681b4", "attributes": [{"value": "ITALIA", "name": "Procedencia", "id": "1"}, {"value": "ESAOTE SPA", "name": "Fabricante", "id": "3"}, {"value": "ESAOTE", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "33", "id": "7"}]}, {"id": "1ef66c97-ba59-65be-929b-03138fe681b4", "description": "Ecografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42201718-001", "description": "Ecografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42201718-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42201718", "description": "Ecografos y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42201718"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 288000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba58-6a24-b58f-03138fe681b4", "attributes": [{"value": "ITALIA", "name": "Procedencia", "id": "1"}, {"value": "ESAOTE SPA", "name": "Fabricante", "id": "3"}, {"value": "ESAOTE", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "34", "id": "7"}]}, {"id": "1ef66c97-bb40-6388-985e-03138fe681b4", "description": "Transductor para ecografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42201711-001", "description": "Transductor para ecografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42201711-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42201711", "description": "Transductores ecograficos medicos de ultrasonidos, efecto Doppler o eco, o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42201711"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 44000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb3e-6eca-8726-03138fe681b4", "attributes": [{"value": "ITALIA", "name": "Procedencia", "id": "1"}, {"value": "ESAOTE SPA", "name": "Fabricante", "id": "3"}, {"value": "ESAOTE", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "65", "id": "7"}]}, {"id": "1ef66c97-bb48-679a-8107-03138fe681b4", "description": "Transductor para ecografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42201711-001", "description": "Transductor para ecografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42201711-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42201711", "description": "Transductores ecograficos medicos de ultrasonidos, efecto Doppler o eco, o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42201711"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 44000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb47-6354-b58a-03138fe681b4", "attributes": [{"value": "ITALIA", "name": "Procedencia", "id": "1"}, {"value": "ESAOTE SPA", "name": "Fabricante", "id": "3"}, {"value": "ESAOTE", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "66", "id": "7"}]}]}, {"id": "1ef8bbdd-ce68-682e-9cb6-832f507ce7a1", "status": "active", "statusDetails": "publicado", "date": "2024-10-16T00:00:00-04:00", "value": {"amount": 96200000, "currency": "PYG"}, "suppliers": [{"name": "BIOERIX S.A. ", "id": "PY-RUC-80051821-7"}], "documents": [{"id": "dix2iRRDbik=", "title": "URL de la Adjudicaci\u00f3n", "url": "https://www.contrataciones.gov.py/licitaciones/adjudicacion/1ef8bbaf-a583-61da-88c5-1bed43a37266/resumen-adjudicacion.html", "language": "es", "documentType": "awardNotice", "format": "text/html"}, {"id": "1ef8c720-c27c-6aee-90f1-5f2465ebf343", "datePublished": "2024-10-17T07:24:52-04:00", "title": "2268-resol-d-n-1790-adj-lpn-n-21-024-6710e5f4ccaac.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/dad19b6a-f9d0-4c17-9f55-2d712bc71847/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "1ef8c721-2715-68ca-b8a6-359fb6476ff3", "datePublished": "2024-10-17T07:25:03-04:00", "title": "cco-lpn-21-2024-6710e5ff5fdc4.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/183e8af1-0475-4ad6-96ae-2ae39582a128/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef907c6-c894-624c-b4af-873b674c807d", "datePublished": "2024-10-22T10:49:14-04:00", "title": "inf-eva-lpn-21-2024-comp1-6717ad5a31d1d.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/4edd617f-8c88-4ff1-9532-93f73879cbce/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "1ef8c722-d10b-6d06-8dd7-fd94b7f65888", "datePublished": "2024-10-17T07:25:48-04:00", "title": "inf-eva-lpn-21-2024-6710e62badd24.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/f635d362-29b8-41e6-8e6f-906512f3cf85/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "1ef907c6-252c-66c2-a0f8-8101fb3213b1", "datePublished": "2024-10-22T10:48:57-04:00", "title": "cco-lpn-21-2024-comp1-6717ad4915e58.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/e6b0c92f-e43b-484f-9247-9265eacaeaa6/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef907c5-a74b-6f6e-b1dc-83a828c23e82", "datePublished": "2024-10-22T10:48:43-04:00", "title": "reso-adj-lpn-21-2024-comp1-6717ad3bcfebb.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/bb615421-b2fb-4f08-a8f9-6cfbb1a8e6b7/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}], "items": [{"id": "1ef66c97-baaf-61da-aa03-03138fe681b4", "description": "Microscopios de fluorescencia", "classification": {"scheme": "catalogoNivel5DNCP", "id": "41111722-001", "description": "Microscopios de fluorescencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/41111722-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "41111722", "description": "Microscopios de fluorescencia y Accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/41111722"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 96200000, "currency": "PYG"}}, "relatedLot": "1ef66c97-baae-65be-9437-03138fe681b4", "attributes": [{"value": "EEUU / JAPON / CHINA", "name": "Procedencia", "id": "1"}, {"value": "EVIDENT CORPORATION", "name": "Fabricante", "id": "3"}, {"value": "OLYMPUS", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "51", "id": "7"}]}]}, {"id": "1ef8bca3-d665-62d6-bf3d-03e9b40e05cd", "status": "active", "statusDetails": "publicado", "date": "2024-10-16T00:00:00-04:00", "value": {"amount": 220000000, "currency": "PYG"}, "suppliers": [{"name": "SURVYCON S.A. SURVEY & CONTROL", "id": "PY-RUC-80063377-6"}], "documents": [{"id": "1ef907c6-c894-624c-b4af-873b674c807d", "datePublished": "2024-10-22T10:49:14-04:00", "title": "inf-eva-lpn-21-2024-comp1-6717ad5a31d1d.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/4edd617f-8c88-4ff1-9532-93f73879cbce/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "1ef907c6-252c-66c2-a0f8-8101fb3213b1", "datePublished": "2024-10-22T10:48:57-04:00", "title": "cco-lpn-21-2024-comp1-6717ad4915e58.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/e6b0c92f-e43b-484f-9247-9265eacaeaa6/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "1ef8c722-d10b-6d06-8dd7-fd94b7f65888", "datePublished": "2024-10-17T07:25:48-04:00", "title": "inf-eva-lpn-21-2024-6710e62badd24.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/f635d362-29b8-41e6-8e6f-906512f3cf85/download", "language": "es", "documentTypeDetails": "Informe de Evaluaci\u00f3n"}, {"id": "1ef907c5-a74b-6f6e-b1dc-83a828c23e82", "datePublished": "2024-10-22T10:48:43-04:00", "title": "reso-adj-lpn-21-2024-comp1-6717ad3bcfebb.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/bb615421-b2fb-4f08-a8f9-6cfbb1a8e6b7/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}, {"id": "1ef8c721-2715-68ca-b8a6-359fb6476ff3", "datePublished": "2024-10-17T07:25:03-04:00", "title": "cco-lpn-21-2024-6710e5ff5fdc4.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/183e8af1-0475-4ad6-96ae-2ae39582a128/download", "language": "es", "documentTypeDetails": "Cuadro Comparativo de Ofertas"}, {"id": "dix2iRRDbik=", "title": "URL de la Adjudicaci\u00f3n", "url": "https://www.contrataciones.gov.py/licitaciones/adjudicacion/1ef8bbaf-a583-61da-88c5-1bed43a37266/resumen-adjudicacion.html", "language": "es", "documentType": "awardNotice", "format": "text/html"}, {"id": "1ef8c720-c27c-6aee-90f1-5f2465ebf343", "datePublished": "2024-10-17T07:24:52-04:00", "title": "2268-resol-d-n-1790-adj-lpn-n-21-024-6710e5f4ccaac.pdf", "url": "https://www.contrataciones.gov.py/api/resultado/1ef8bbaf-a583-61da-88c5-1bed43a37266/files/dad19b6a-f9d0-4c17-9f55-2d712bc71847/download", "language": "es", "documentType": "awardNotice", "documentTypeDetails": "Resoluci\u00f3n de Adjudicaci\u00f3n"}], "items": [{"id": "1ef66c97-ba68-6488-a7ee-03138fe681b4", "description": "Equipo de hemodialisis", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42161632-001", "description": "Equipo de hemodialisis", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42161632-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42161632", "description": "Unidad de hemodialisis y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42161632"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 110000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba67-683a-8b82-03138fe681b4", "attributes": [{"value": "CHINA", "name": "Procedencia", "id": "1"}, {"value": "SWS HEMODIALYSIS CARE CO., LTD.", "name": "Fabricante", "id": "3"}, {"value": "SWS", "name": "Marca", "id": "4"}, {"name": "Orden", "value": "37", "id": "7"}]}]}], "parties": [{"id": "DNCP-SICP-CODE-226", "name": "Universidad Nacional de Asunci\u00f3n (UNA)", "identifier": {"id": "226", "legalName": "Universidad Nacional de Asunci\u00f3n (UNA)", "scheme": "DNCP-SICP-CODE"}, "additionalIdentifiers": [{"id": "2024.28.1", "legalName": "Universidad Nacional de Asunci\u00f3n", "scheme": "PY-PGN"}], "roles": ["buyer"]}, {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n", "identifier": {"scheme": "DNCP-SICP-CODE", "id": "1360", "legalName": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "contactPoint": {"email": "uoc@fcmuna.edu.py", "name": "LIC. LIZ RAQUEL DUARTE QUINTANA"}, "roles": ["procuringEntity", "payer"], "details": {"level": "Universidades Nacionales", "entityType": "Entidades Descentralizadas", "type": "Unidad Contrataci\u00f3n"}, "memberOf": [{"id": "DNCP-SICP-CODE-226", "name": "Universidad Nacional de Asunci\u00f3n (UNA)"}]}, {"name": "HELEN DEL MAR MARTINEZ INSAURRALDE", "id": "PY-RUC-5041516-6", "identifier": {"id": "5041516-6", "legalName": "HELEN DEL MAR MARTINEZ INSAURRALDE", "scheme": "PY-RUC"}, "roles": ["enquirer"], "contactPoint": {"name": "HELEN DEL MAR MARTINEZ INSAURRALDE", "email": "helenmartinez5@gmail.com", "telephone": "0994252630"}, "address": {"countryName": "Paraguay", "locality": "SAN LORENZO", "region": "Central", "streetAddress": "CORDOBA C/ AVDA LA VICTORIA"}, "details": {"legalEntityTypeDetail": "Persona F\u00edsica - Bienes y Servicios", "activityTypes": ["goods", "services"], "categories": [{"name": "Servicios T\u00e9cnicos", "id": 7}, {"name": "Capacitaciones y Adiestramientos", "id": 4}]}}, {"name": "VICENTE SCAVONE & CIA. S.A.E", "id": "PY-RUC-80001446-4", "identifier": {"id": "80001446-4", "legalName": "VICENTE SCAVONE & CIA. S.A.E", "scheme": "PY-RUC"}, "roles": ["tenderer"], "contactPoint": {"name": "PASCUAL SCAVONE - CHRISTIAN ALEXANDER WENTZENSEN - VICENTE SCAVONE C\u00c1RDENAS-C\u00c9SAR SCAVONE CARDENAS-MARIA HERMINIA CABALLERO - MARIA PAZ ZALDIVAR CABALLERO - SILVANA CANDIA- Ricardo Maciel", "email": "licita@lasca.com.py", "faxNumber": "522 322", "telephone": "0981 438 279", "url": "http://www.lasca.com.py"}, "address": {"countryName": "Paraguay", "locality": "SAN LORENZO.", "region": "Central", "streetAddress": "PASTORA C\u00c9SPEDES Y VICENTE SCAVONE."}, "details": {"legalEntityTypeDetail": "C.I.S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}, {"name": "Textiles, vestuarios y calzados", "id": 10}, {"name": "Bienes e insumos agropecuario y forestal", "id": 19}]}}, {"name": "CASA BOLLER S.A.", "id": "PY-RUC-80001556-8", "identifier": {"id": "80001556-8", "legalName": "CASA BOLLER S.A.", "scheme": "PY-RUC"}, "roles": ["enquirer"], "contactPoint": {"name": "JOSE RODRIGO CAMPOS CERVERA - SEBASTIAN CAMPOS CERVERA", "email": "licitaciones@boller.com.py", "faxNumber": "6885105", "url": "http://www.boller.com.py"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION", "region": "Asunci\u00f3n", "streetAddress": "AVDA.AVIADORES DEL CHACO 2518 e/SAN BLAS"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Adquisici\u00f3n y Locaci\u00f3n de inmuebles. Alquiler de muebles", "id": 3}, {"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}, {"name": "Capacitaciones y Adiestramientos", "id": 4}, {"name": "Equipos Militares y de Seguridad. Servicio de Seguridad y Vigilancia", "id": 25}, {"name": "Construcci\u00f3n, Restauraci\u00f3n, Reconstrucci\u00f3n o Remodelaci\u00f3n y Reparaci\u00f3n de Inmuebles", "id": 21}, {"name": "Equipos, accesorios y programas computacionales, de oficina, educativos, de imprenta, de comunicaci\u00f3n y se\u00f1alamiento", "id": 24}, {"name": "Textiles, vestuarios y calzados", "id": 10}]}}, {"name": "EDUARDO ELIZECHE BENITEZ SAC", "id": "PY-RUC-80002379-0", "identifier": {"id": "80002379-0", "legalName": "EDUARDO ELIZECHE BENITEZ SAC", "scheme": "PY-RUC"}, "roles": ["enquirer"], "contactPoint": {"name": "PATRICIA GRANDA DE SERRATI, PAULINA GRANDA SERRATI", "email": "licitaciones@elizechesac.com", "faxNumber": "223233", "telephone": "0986-174299", "url": "http://www.elizechesac.com"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION", "region": "Central", "streetAddress": "AVDA SACRAMENTO 2409"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}, {"name": "Consultor\u00edas, Asesor\u00edas e Investigaciones. Estudios y Proyectos de inversi\u00f3n", "id": 5}, {"name": "Servicios de Limpiezas, Mantenimientos y reparaciones menores y mayores de Instalaciones, Maquinarias y Veh\u00edculos", "id": 2}]}}, {"name": "ALBATROS SACI", "id": "PY-RUC-80002766-3", "identifier": {"id": "80002766-3", "legalName": "ALBATROS SACI", "scheme": "PY-RUC"}, "roles": ["enquirer", "tenderer", "supplier", "payee"], "contactPoint": {"name": "ROLF WALTER THIEDE FRIESEN - PAUL MATTHIAS THIEDE DICHTL", "email": "albatros@albatros.com.py", "faxNumber": "441407", "telephone": "0981 416733", "url": "http://www.albatros.com.py"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION (DISTRITO)", "region": "Asunci\u00f3n", "streetAddress": "DR. NARCISO MENDEZ BENITEZ N\u00ba 404 E/ MAYOR NICOLAS GOLDSCHMIDT Y DR. PABLO MAX INSFRAN"}, "details": {"legalEntityTypeDetail": "S.A.C.I.", "activityTypes": ["goods", "services"], "categories": [{"name": "Maquinarias, Equipos y herramientas mayores - Equipos de transporte", "id": 22}, {"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}, {"name": "Servicios de Limpiezas, Mantenimientos y reparaciones menores y mayores de Instalaciones, Maquinarias y Veh\u00edculos", "id": 2}, {"name": "Muebles y Enseres", "id": 23}, {"name": "Utensilios de cocina y comedor, Productos de Porcelana, vidrio y loza", "id": 13}]}}, {"name": "ARGON S.R.L.", "id": "PY-RUC-80004373-1", "identifier": {"id": "80004373-1", "legalName": "ARGON S.R.L.", "scheme": "PY-RUC"}, "roles": ["tenderer", "supplier", "payee"], "contactPoint": {"name": "CARLOS ROBERTO GONZ\u00c1LEZ - OSCAR FELIX GARCETE - NORA ELIZABETH PEDROZO -  GUMERCINDO PEDROZO RODR\u00cdGUEZ.", "email": "administrador@argonmed.com", "faxNumber": "021 562 231", "telephone": "0981 321 813 ", "url": "https://www.argonmed.com"}, "address": {"countryName": "Paraguay", "locality": "ASUNCI\u00d3N.", "region": "Asunci\u00f3n", "streetAddress": "RCA. ARGENTINA N\u00b0 2461 CASI PASO DE PATRIA."}, "details": {"legalEntityTypeDetail": "S.R.L.", "activityTypes": ["goods", "services"], "categories": [{"name": "Maquinarias, Equipos y herramientas mayores - Equipos de transporte", "id": 22}, {"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}, {"name": "Servicios de Limpiezas, Mantenimientos y reparaciones menores y mayores de Instalaciones, Maquinarias y Veh\u00edculos", "id": 2}]}}, {"name": "BIOTEC DEL PARAGUAY S.A.", "id": "PY-RUC-80008449-7", "identifier": {"id": "80008449-7", "legalName": "BIOTEC DEL PARAGUAY S.A.", "scheme": "PY-RUC"}, "roles": ["enquirer"], "contactPoint": {"name": "GONZALO IGNACIO SAMANIEGO ZUBIZARRETA- CARLOS AYALA- LORENA SAMANIEGO", "email": "licitaciones@biotec.com.py", "url": "http://www.biotec.com.py"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION", "region": "Asunci\u00f3n", "streetAddress": "TUYUTI N\u00b01545 ENTRE AVDA.JOSE FELIX BOGADO Y GRAL.FRANCISCO MIRANDA"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Productos quimicos", "id": 16}, {"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}]}}, {"name": "FALCON COM. & IND. S.A.", "id": "PY-RUC-80010835-3", "identifier": {"id": "80010835-3", "legalName": "FALCON COM. & IND. S.A.", "scheme": "PY-RUC"}, "roles": ["enquirer"], "contactPoint": {"name": "RODOLFO ARCE GODOY; WALTER ARCE GODOY; CHRISTIAN ARCE GODOY", "email": "falcon@falcon.com.py", "faxNumber": "+59521655680", "telephone": "+595981511108", "url": "http://www.falcon.com.py"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION", "region": "Asunci\u00f3n", "streetAddress": "Calle Guido Spano N\u00b0 3052"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"]}}, {"name": "LCM SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80011068-4", "identifier": {"id": "80011068-4", "legalName": "LCM SOCIEDAD AN\u00d3NIMA", "scheme": "PY-RUC"}, "roles": ["tenderer", "supplier", "payee"], "contactPoint": {"name": "CARLOS CLARI- ROCIO ACU\u00d1A- LUCAS CLARI- LUCIANO ORTELLADO", "email": "licitaciones@lcm.com.py", "faxNumber": "449-479", "telephone": "0981-929988", "url": "http://www.lacasadelmedico.com.py"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION", "region": "Asunci\u00f3n", "streetAddress": "ELIGIO AYALA 878"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}, {"name": "Textiles, vestuarios y calzados", "id": 10}, {"name": "Productos quimicos", "id": 16}]}}, {"name": "B.BRAUN MEDICAL PARAGUAY S.A.", "id": "PY-RUC-80012330-1", "identifier": {"id": "80012330-1", "legalName": "B.BRAUN MEDICAL PARAGUAY S.A.", "scheme": "PY-RUC"}, "roles": ["enquirer"], "contactPoint": {"name": "JESUS DONADO-MAZARRON, JOGE CADENA, MARTIN HELMUT", "email": "licitaciones.py@bbraun.com", "faxNumber": "752480", "url": "http://www.bbraun.com"}, "address": {"countryName": "Paraguay", "locality": "MARIANO ROQUE ALONSO", "region": "Asunci\u00f3n", "streetAddress": "CRISTOBAL COLON N\u00b0 230"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Productos Alimenticios", "id": 14}, {"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}, {"name": "Productos quimicos", "id": 16}]}}, {"name": "CHARPENTIER SRL", "id": "PY-RUC-80013232-7", "identifier": {"id": "80013232-7", "legalName": "CHARPENTIER SRL", "scheme": "PY-RUC"}, "roles": ["enquirer"], "contactPoint": {"name": "LUIS ABENTE PECCI- MARIA PALOMA ABENTE ", "email": "licitaciones@charpentier.com.py", "faxNumber": "600824"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION", "region": "Asunci\u00f3n", "streetAddress": "Avda Mariscal L\u00f3pez 2781 casi Reclus"}, "details": {"legalEntityTypeDetail": "S.R.L.", "activityTypes": ["goods", "services"], "categories": [{"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}, {"name": "Minerales", "id": 20}, {"name": "Materiales e insumos el\u00e9ctricos, met\u00e1licos y no met\u00e1licos, Pl\u00e1sticos, cauchos. Repuestos, herramientas, c\u00e1maras y cubiertas.", "id": 18}]}}, {"name": "DYSA HEALTHCARE S.A.", "id": "PY-RUC-80013820-1", "identifier": {"id": "80013820-1", "legalName": "DYSA HEALTHCARE S.A.", "scheme": "PY-RUC"}, "roles": ["tenderer", "supplier", "enquirer", "payee"], "contactPoint": {"name": "RICARDO HELLMERS FONSECA- Ricardo Hellmers Llano- Juan Gabriel Appleyard- Luis Pettengil- Ivan Maciel- Benjamin Diaz de Bedoya", "email": "informes@dysa.com.py", "faxNumber": "282098", "telephone": "981680068"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION (DISTRITO)", "region": "Asunci\u00f3n", "streetAddress": "AVDA.ARTIGAS C/AVDA.VENEZUELA 2698"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"]}}, {"name": "IMESE S.A.", "id": "PY-RUC-80016426-1", "identifier": {"id": "80016426-1", "legalName": "IMESE S.A.", "scheme": "PY-RUC"}, "roles": ["supplier", "enquirer", "tenderer", "payee"], "contactPoint": {"name": "EMIGDIO ELIZAUR ALFONSO - MARIA EMILIA ELIZAUR GAONA", "email": "licitaciones@imese.com.py", "faxNumber": "021390915", "telephone": "0981540573", "url": "http://www.imese.com.py"}, "address": {"countryName": "Paraguay", "locality": "ASUNCI\u00d3N.", "region": "Asunci\u00f3n", "streetAddress": "CABALLERO N\u00b0 1642."}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Elementos e insumos de limpieza", "id": 12}, {"name": "Productos Alimenticios", "id": 14}, {"name": "Utensilios de cocina y comedor, Productos de Porcelana, vidrio y loza", "id": 13}, {"name": "Textiles, vestuarios y calzados", "id": 10}, {"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}, {"name": "Equipos, accesorios y programas computacionales, de oficina, educativos, de imprenta, de comunicaci\u00f3n y se\u00f1alamiento", "id": 24}]}}, {"name": "DROGUERIA ITALQUIMICA SOCIEDAD ANONIMA", "id": "PY-RUC-80017185-3", "identifier": {"id": "80017185-3", "legalName": "DROGUERIA ITALQUIMICA SOCIEDAD ANONIMA", "scheme": "PY-RUC"}, "roles": ["enquirer"], "contactPoint": {"name": "BLAS VAZQUEZ FLEYTAS, RITA DE VAZQUEZ, JOSE ESPINOLA - Maria Nidia Fari\u00f1a", "email": "licitaciones@italquimica.com.py", "faxNumber": "512040"}, "address": {"countryName": "Paraguay", "locality": "FERNANDO DE LA MORA", "region": "Central", "streetAddress": "RIO YHAGUY ESQ. COLON"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Elementos e insumos de limpieza", "id": 12}, {"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}, {"name": "Productos quimicos", "id": 16}]}}, {"name": "IMPORTEX S.A.", "id": "PY-RUC-80017358-9", "identifier": {"id": "80017358-9", "legalName": "IMPORTEX S.A.", "scheme": "PY-RUC"}, "roles": ["enquirer"], "contactPoint": {"name": "GABRIEL AVILA- FRANCESCA SCAVONE-VICTOR MENDEZ - RUTH SINGER - MICHAEL JACK HERSCHKOWICZ- Gabriela Mujica", "email": "licitaciones@importex.com.py", "faxNumber": "449337", "telephone": "0971 207 028"}, "address": {"countryName": "Paraguay", "locality": "ASUNCI\u00d3N.", "region": "Asunci\u00f3n", "streetAddress": "NUESTRA SE\u00d1ORA DE LA ASUNCI\u00d3N N\u00ba 1181 C/ RODR\u00cdGUEZ DE FRANCIA."}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}]}}, {"name": "ANDRES H. ARCE SA", "id": "PY-RUC-80023488-0", "identifier": {"id": "80023488-0", "legalName": "ANDRES H. ARCE SA", "scheme": "PY-RUC"}, "roles": ["supplier", "tenderer", "payee"], "contactPoint": {"name": "JUAN CARLOS ARCE RAMIREZ", "email": "licitaciones@aharce.com.py", "faxNumber": "220500", "telephone": "0981-666011"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION (DISTRITO)", "region": "Asunci\u00f3n", "streetAddress": "BRASIL 198 E/ JOSE BERGES"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"]}}, {"name": "SOLUMEDIC S.A.", "id": "PY-RUC-80023913-0", "identifier": {"id": "80023913-0", "legalName": "SOLUMEDIC S.A.", "scheme": "PY-RUC"}, "roles": ["tenderer", "supplier", "payee"], "contactPoint": {"name": "VICTOR RAMON CABA\u00d1AS RERNANDEZ", "email": "info@solumedic.com", "faxNumber": "226673", "telephone": "0981280553", "url": "http://www.solumedic.com.py"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION", "region": "Asunci\u00f3n", "streetAddress": "DR. MORQUIO 447"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}]}}, {"name": "STEVEN S SA", "id": "PY-RUC-80024104-5", "identifier": {"id": "80024104-5", "legalName": "STEVEN S SA", "scheme": "PY-RUC"}, "roles": ["enquirer"], "contactPoint": {"name": "SANDRA LORENA OVELAR - LIZ ROSSANA VERA MAR\u00cdN.", "email": "aline_kochuruba@stevenmedical.com", "faxNumber": "229462", "telephone": "0983939219", "url": "http://www.stevenmedical.com"}, "address": {"countryName": "Paraguay", "locality": "ASUNCI\u00d3N.", "region": "Asunci\u00f3n", "streetAddress": "Ana D\u00edaz N\u00b0 1145."}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Materiales e insumos el\u00e9ctricos, met\u00e1licos y no met\u00e1licos, Pl\u00e1sticos, cauchos. Repuestos, herramientas, c\u00e1maras y cubiertas.", "id": 18}, {"name": "Utiles de oficina, Productos de papel y cart\u00f3n e impresos", "id": 11}, {"name": "Utensilios de cocina y comedor, Productos de Porcelana, vidrio y loza", "id": 13}, {"name": "Textiles, vestuarios y calzados", "id": 10}, {"name": "Elementos e insumos de limpieza", "id": 12}]}}, {"name": "CHACO INTERNACIONAL SA", "id": "PY-RUC-80026564-5", "identifier": {"id": "80026564-5", "legalName": "CHACO INTERNACIONAL SA", "scheme": "PY-RUC"}, "roles": ["enquirer"], "contactPoint": {"name": "CARMEN STELLA ESCOBAR BARRIOCANAL- SILVANA LOPEZ- EFREN LOPEZ", "email": "licitaciones_chaco@chacointernacional.com.py", "faxNumber": "2385707", "telephone": "0981-435.000", "url": "http://www.chacointernacional.com.py"}, "address": {"countryName": "Paraguay", "locality": "LAMBARE", "region": "Central", "streetAddress": "San Juan Mar\u00eda Vianney N\u00b0 1684 c/ Bruno Guggiari e/ Juan Pablo II"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Productos quimicos", "id": 16}, {"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}]}}, {"name": "GAESA SA", "id": "PY-RUC-80026596-3", "identifier": {"id": "80026596-3", "legalName": "GAESA SA", "scheme": "PY-RUC"}, "roles": ["tenderer"], "contactPoint": {"name": "JULIO CESAR BOBADILLA SANDOVAL", "email": "licitacionesgaesa@gmail.com", "faxNumber": "232623/4"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION (DISTRITO)", "region": "Asunci\u00f3n", "streetAddress": "CHOFERES DEL CHACO 9001 Y JULIANA INSFRAN"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods"], "categories": [{"name": "Servicios de Limpiezas, Mantenimientos y reparaciones menores y mayores de Instalaciones, Maquinarias y Veh\u00edculos", "id": 2}, {"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}, {"name": "Muebles y Enseres", "id": 23}, {"name": "Textiles, vestuarios y calzados", "id": 10}]}}, {"name": "IN SITU S.A.", "id": "PY-RUC-80027373-7", "identifier": {"id": "80027373-7", "legalName": "IN SITU S.A.", "scheme": "PY-RUC"}, "roles": ["supplier", "tenderer", "payee"], "contactPoint": {"name": "ERIK PATRICIO WUTH AGUILERA- PAMELA VARGAS", "email": "insitu@insitu.com.py", "faxNumber": "228-068", "telephone": "0982-100603", "url": "http://www.insitu.com.py"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION", "region": "Asunci\u00f3n", "streetAddress": "SIRIA 515 E/ PITIANTUTA"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}, {"name": "Servicios T\u00e9cnicos", "id": 7}]}}, {"name": "DGR INTERNACIONAL S.R.L.", "id": "PY-RUC-80028232-9", "identifier": {"id": "80028232-9", "legalName": "DGR INTERNACIONAL S.R.L.", "scheme": "PY-RUC"}, "roles": ["enquirer"], "contactPoint": {"name": "VICTOR DANIEL GUGLIOTTA RUGGERI", "email": "dguglio@rieder.net.py", "faxNumber": "210536", "telephone": "981999848"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION", "region": "Asunci\u00f3n", "streetAddress": "PAI PEREZ 1020"}, "details": {"scale": "sme", "legalEntityTypeDetail": "S.R.L.", "activityTypes": ["goods", "services"], "categories": [{"name": "Servicios de Limpiezas, Mantenimientos y reparaciones menores y mayores de Instalaciones, Maquinarias y Veh\u00edculos", "id": 2}, {"name": "Equipos, accesorios y programas computacionales, de oficina, educativos, de imprenta, de comunicaci\u00f3n y se\u00f1alamiento", "id": 24}]}}, {"name": "CATETERES Y AFINES S.A.", "id": "PY-RUC-80030030-0", "identifier": {"id": "80030030-0", "legalName": "CATETERES Y AFINES S.A.", "scheme": "PY-RUC"}, "roles": ["enquirer", "supplier", "tenderer", "payee"], "contactPoint": {"name": "Patricia Noemi Fontela Meletti- Eduardo Javier Sanabria Cort\u00e1zar", "email": "trade4@caphar.com.py", "faxNumber": "228620", "telephone": "0982163434"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION", "region": "Central", "streetAddress": "Carmen Soler 3894 c/ Radio Operadores del Chaco "}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods"], "categories": [{"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}]}}, {"name": "PROSALUD FARMA S.A.", "id": "PY-RUC-80033584-8", "identifier": {"id": "80033584-8", "legalName": "PROSALUD FARMA S.A.", "scheme": "PY-RUC"}, "roles": ["enquirer"], "contactPoint": {"name": "Juan Domingo Rienzi Grassi, Camila Rienzi, Christian Rienzi- Magdalena Anahi Castro", "email": "licitaciones@prosaludfarma.com.py", "faxNumber": "281128 / 283093", "telephone": "0981782415"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION", "region": "Asunci\u00f3n", "streetAddress": "LOMBARDO 2051 C/ TTE. ENCISO"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Productos quimicos", "id": 16}, {"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}]}}, {"name": "BIOERIX S.A. ", "id": "PY-RUC-80051821-7", "identifier": {"id": "80051821-7", "legalName": "BIOERIX S.A. ", "scheme": "PY-RUC"}, "roles": ["supplier", "tenderer", "payee"], "contactPoint": {"name": "ROBERT HARRISON- ALDO HARRISON-  DIEGO FELIPE SANABRIA", "email": "licitaciones@bioerix.com.py", "telephone": "0976 201 597"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION", "region": "Central", "streetAddress": "Jos\u00e9 A. Flores 2548 c/ Avda. General Santos"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Consultor\u00edas, Asesor\u00edas e Investigaciones. Estudios y Proyectos de inversi\u00f3n", "id": 5}, {"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}]}}, {"name": "EUROQUIMICA S.A.", "id": "PY-RUC-80061211-6", "identifier": {"id": "80061211-6", "legalName": "EUROQUIMICA S.A.", "scheme": "PY-RUC"}, "roles": ["enquirer"], "contactPoint": {"name": "MARCELO RIENZI ZUCOLILLO - PAOLA RIENZI ZUCOLILLO - Paola Roa Gonzalez", "email": "licitaciones@euroquimica.com.py", "faxNumber": "021600777", "telephone": "0972425942"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION (DISTRITO)", "region": "Central", "streetAddress": "AVDA. AVIADORES DEL CHACO CASI LOPEZ MOREIRA (EDIFICIO THE TOP) PISO 10-OFICINA 02"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}]}}, {"name": "SURVYCON S.A. SURVEY & CONTROL", "id": "PY-RUC-80063377-6", "identifier": {"id": "80063377-6", "legalName": "SURVYCON S.A. SURVEY & CONTROL", "scheme": "PY-RUC"}, "roles": ["tenderer", "supplier", "payee"], "contactPoint": {"name": "GERARDO ALVARENGA BONZI- FERNANDO BENITEZ", "email": "survycon@survycon.com.py", "telephone": "0982359596", "url": "http://www.survycon.com.py"}, "address": {"countryName": "Paraguay", "locality": "ASUNCION", "region": "Central", "streetAddress": "AZARA 2950 C/ 33 ORIENTALES"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Elementos e insumos de limpieza", "id": 12}, {"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}, {"name": "Servicios de Limpiezas, Mantenimientos y reparaciones menores y mayores de Instalaciones, Maquinarias y Veh\u00edculos", "id": 2}]}}, {"name": "MACRO SCIENCE SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80064898-6", "identifier": {"id": "80064898-6", "legalName": "MACRO SCIENCE SOCIEDAD AN\u00d3NIMA", "scheme": "PY-RUC"}, "roles": ["tenderer", "enquirer"], "contactPoint": {"name": "ALEJANDRO TRELLLES - MILVA JANET DIAZ - OLGA JARA ", "email": "licitacionesmacro@macroscience.com.py", "faxNumber": "021 512 040"}, "address": {"countryName": "Paraguay", "locality": "FERNANDO DE LA MORA.", "region": "Central", "streetAddress": "Col\u00f3n 628 Casi Rio Yhaguy"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Productos quimicos", "id": 16}, {"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}, {"name": "Utiles de oficina, Productos de papel y cart\u00f3n e impresos", "id": 11}, {"name": "Elementos e insumos de limpieza", "id": 12}]}}, {"name": "SUMI SOCIEDAD ANONIMA", "id": "PY-RUC-80068800-7", "identifier": {"id": "80068800-7", "legalName": "SUMI SOCIEDAD ANONIMA", "scheme": "PY-RUC"}, "roles": ["supplier", "tenderer", "payee"], "contactPoint": {"name": "Sumijiro Takaoka - Yasutaka takaoka -CARLOS SOLIS - JOSIAS BEDOYA", "email": "licitaciones@sumi.com.py"}, "address": {"countryName": "Paraguay", "locality": "LAMBARE", "region": "Central", "streetAddress": "PEDRO GILL C/ YTORORO Casa #935"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Servicios de Limpiezas, Mantenimientos y reparaciones menores y mayores de Instalaciones, Maquinarias y Veh\u00edculos", "id": 2}, {"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}, {"name": "Combustibles y Lubricantes", "id": 15}, {"name": "Servicios T\u00e9cnicos", "id": 7}]}}, {"name": "Medical Supply Sociedad Anonima", "id": "PY-RUC-80092809-1", "identifier": {"id": "80092809-1", "legalName": "Medical Supply Sociedad Anonima", "scheme": "PY-RUC"}, "roles": ["enquirer"], "contactPoint": {"name": "Ram\u00f3n Eduardo Doria Zubizarreta- Sebastian Rojas- Maria Lorena Gimenez- Jorge alberto Perez", "email": "licitaciones@medsupar.com.py", "url": "http://www.medsupar.com.py"}, "address": {"countryName": "Paraguay", "locality": "Luque", "region": "Central", "streetAddress": "Scout de Luque, Z\u00e1rate Isla - Luque"}, "details": {"legalEntityTypeDetail": "S.A.", "activityTypes": ["goods", "services"], "categories": [{"name": "Adquisici\u00f3n y Locaci\u00f3n de inmuebles. Alquiler de muebles", "id": 3}, {"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}, {"name": "Productos quimicos", "id": 16}]}}, {"name": "Consorcio de Insumos Quir\u00fargicos del Paraguay", "id": "PY-RUC-80130658-2", "identifier": {"id": "80130658-2", "legalName": "Consorcio de Insumos Quir\u00fargicos del Paraguay", "scheme": "PY-RUC"}, "roles": ["enquirer"], "contactPoint": {"name": "Ricardo Hellmers Fonseca/ Marcial Nu\u00f1ez Gimenez", "email": "informes@dysa.com.py"}, "address": {"countryName": "Paraguay", "locality": "Asuncion", "region": "Asunci\u00f3n", "streetAddress": "Avda Santa Teresa c/ Aviadores del Chaco Paseo Galer\u00eda Torre 2 piso 26"}, "details": {"legalEntityTypeDetail": "Consorcio", "activityTypes": ["goods", "services"], "categories": [{"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}]}}, {"name": "CONSORCIO DYRMEC", "id": "PY-RUC-80131846-7", "identifier": {"id": "80131846-7", "legalName": "CONSORCIO DYRMEC", "scheme": "PY-RUC"}, "roles": ["enquirer"], "contactPoint": {"name": "Ricardo Hellmers Fonseca, Juan Gabriel Appleyard Pettengill, Javier Eugenio Moreno Iribas, Santiago Jos\u00e9 Moreno Iribas, Hugo Codas Thompson Benza, Oscar Antonio Codas Thompson Benza", "email": "informes@dysa.com.py"}, "address": {"countryName": "Paraguay", "locality": "Asunci\u00f3n", "region": "Asunci\u00f3n", "streetAddress": "Av. Santa Teresa c/ Av. Aviadores del Chaco - Torre 2, Piso 26"}, "details": {"legalEntityTypeDetail": "Consorcio", "activityTypes": ["goods", "services"], "categories": [{"name": "Servicios T\u00e9cnicos", "id": 7}, {"name": "Equipos, Productos e instrumentales M\u00e9dicos y de Laboratorio. Servicios asistenciales de salud", "id": 17}]}}, {"name": "CONSORCIO DYLAV", "id": "PY-RUC-80151156-9", "identifier": {"id": "80151156-9", "legalName": "CONSORCIO DYLAV", "scheme": "PY-RUC"}, "roles": ["enquirer"], "address": {"countryName": "Paraguay", "locality": "1000", "streetAddress": "Avda Santa teresa c/ Avda Aviadores Chaco"}, "details": {"legalEntityTypeDetail": "Consorcio", "activityTypes": ["goods", "services"]}, "contactPoint": {"email": "informes@dysa.com.py"}}, {"name": "CONSORCIO RD", "id": "PY-RUC-80154886-1", "identifier": {"id": "80154886-1", "legalName": "CONSORCIO RD", "scheme": "PY-RUC"}, "roles": ["enquirer"], "address": {"countryName": "Paraguay", "locality": "11009", "streetAddress": "Scout de Luque, Z\u00e1rate Isla"}, "details": {"legalEntityTypeDetail": "Consorcio", "activityTypes": ["services"]}, "contactPoint": {"email": "licitaciones@medsupar.com.py"}}], "tender": {"id": "1ef5fba1-ce71-61f8-8818-a11be0626a70", "title": "ADQUISICI\u00d3N DE EQUIPOS M\u00c9DICOS PARA LA FACULTAD DE CIENCIAS M\u00c9DICAS Y EL HOSPITAL DE CL\u00cdNICAS", "status": "complete", "awardCriteria": "priceOnly", "awardCriteriaDetails": "Por Item", "submissionMethod": ["inPerson"], "bidOpening": {"date": "2024-10-04T09:30:00-04:00", "address": {"streetAddress": "DPTO. DE CONTRATACIONES PUBLICAS - AVDA. MARISCAL LOPEZ ESQ. CORONEL CAZAL (PLANTA BAJA - NHC)"}}, "submissionMethodDetails": "Lugar entrega ofertas: DPTO. DE CONTRATACIONES PUBLICAS - AVDA. MARISCAL LOPEZ ESQ. CORONEL CAZAL (PLANTA BAJA - NHC)", "statusDetails": "Adjudicada", "enquiriesAddress": {"streetAddress": "SICP"}, "mainProcurementCategoryDetails": "Bienes - Equipos Accesorios y Suministros Medicos", "hasEnquiries": false, "value": {"amount": 9999502988, "currency": "PYG"}, "datePublished": "2024-09-10T17:00:05-04:00", "tenderPeriod": {"startDate": "2024-09-10T17:00:05-04:00", "endDate": "2024-10-04T09:00:00-04:00", "durationInDays": 23}, "awardPeriod": {"startDate": "2024-10-04T09:30:00-04:00"}, "enquiryPeriod": {"endDate": "2024-09-26T07:00:00-04:00", "startDate": "2024-09-10T17:00:05-04:00", "durationInDays": 15}, "mainProcurementCategory": "services", "additionalProcurementCategories": ["services"], "procurementMethod": "open", "procurementMethodDetails": "Licitaci\u00f3n P\u00fablica Nacional", "procuringEntity": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "criteria": [{"id": "1", "title": "Garant\u00eda de Mantenimiento de Ofertas", "description": "Los oferentes, proveedores o contratistas deber\u00e1n garantizar la seriedad de sus ofertas, mediante la garant\u00eda de mantenimiento de la oferta", "source": "tenderer", "requirementGroups": [{"id": "1-1", "description": "La garant\u00eda debe ser de un cierto porcentaje, periodo y tipo", "requirements": [{"id": "1-1-1", "title": "Porcentaje de la garantia", "expectedValue": "5"}, {"id": "1-1-2", "title": "Validez de la garantia en d\u00edas", "expectedValue": "120"}]}]}], "enquiries": [{"id": "5d897dbb0424894409299a8255932821-1", "date": "2024-09-18T10:41:52-04:00", "title": "/*Requisitos documentales para evaluar el criterio de capacidad t\u00e9cnica", "description": "12: Declaracion Jurada de que la empresa adjudicada se compromete a:... -Que proveer\u00e1 Asistencia t\u00e9cnica seg\u00fan necesidad, sea mantenimiento preventivo o correctivo, en un periodo menor a 48 hs., stock de repuestos y accesorios originales de f\u00e1brica. Solicitamos a la convocante excluir el requerimiento debido que es imposible determinar cual ser\u00eda la necesidad de la Convocante durante el uso del equipo. En cambio sugerimos a la Convocante solicitar que los equipos ya cuenten con una garant\u00eda establecida (de 1 a\u00f1o m\u00ednimo), en los cuales ya se contemple un mantenimiento preventivo a los 6 meses de uso del mismo y otro antes de finalizar la garant\u00eda.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:18:01-04:00"}, {"id": "0f1c365d9c25d54f526910002636ec4c-1", "date": "2024-09-18T19:24:44-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 34. Punto 4.11", "description": "Solicitamos a la convocante que ajuste la especificaci\u00f3n de \"Memoria CINE de al menos 9000 cuadros\" a un m\u00ednimo de 1000 cuadros. La cifra solicitada de 9000 cuadros es muy alta en relaci\u00f3n con el precio referencial indicado, y generalmente est\u00e1 asociada a ec\u00f3grafos de gama muy alta. Reducir este requisito permitir\u00e1 una mayor viabilidad en la selecci\u00f3n de equipos dentro del rango de precios establecido.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:17:11-04:00"}, {"id": "c8a186d959191087f87cff6893efa7e0-1", "date": "2024-09-18T16:06:24-04:00", "title": "item 36. Electrocardiografo", "description": "Punto 4.10 Capacidad de 18 derivadas con cables de 10 v\u00edas, sin necesidad de cambiar la posici\u00f3n de los electrodos. De manera a permitir mayor participaci\u00f3n de oferentes Solicitamos diga: Punto 4.10 Capacidad de 18 derivadas con cables de 10 v\u00edas.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:26:29-04:00"}, {"id": "20979b8cbd2aae494fa26197968e126a-1", "date": "2024-09-18T22:35:08-04:00", "title": "\u00cdtem 38 \u2013 Equipo de Rayos X M\u00f3vil", "description": "Donde dice \"Longitud total 1450 mm \u00b1 50 mm\" solicitamos a la convocante modificar este punto a \"Longitud total 1250 mm \u00b1 50 mm\" La diferencia solicitada es m\u00ednima, adem\u00e1s, dicho par\u00e1metro es est\u00e1ndar en la mayor\u00eda de los equipos de rayos x m\u00f3vil y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos se actualice este punto a fin de tener la participaci\u00f3n de las marcas con reconocida representaci\u00f3n y comprobada calidad en el mercado local e internacional. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 38 est\u00e1n direccionadas a la marca SHIMADZU modelo MobileArt Eco MUX-10, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:35:15-04:00"}, {"id": "2fc3676162293af4d1219aaa0a15b57b-1", "date": "2024-09-18T14:19:41-04:00", "title": "\u00cdtem 26 Carro de paro", "description": "4.2 Cinco (05) cajones como m\u00ednimo, de tres medidas diferentes, dos paneles de 80mm de altura como m\u00ednimo, dos paneles de 120mm de altura como m\u00ednimo y un panel grande de 240mm de altura como m\u00ednimo. Al menos 2 (dos) de ellas con separaciones pl\u00e1sticas.\n\u00bfSe podr\u00eda considerar: Cinco (05) cajones como m\u00ednimo, de tres medidas diferentes, dos paneles de 80mm de altura como m\u00ednimo, dos paneles de 120mm de altura como m\u00ednimo y un panel grande de 240mm de altura como m\u00ednimo o dimensiones seg\u00fan el fabricante. Al menos 2 (dos) de ellas con separaciones pl\u00e1sticas?", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:22:34-04:00"}, {"id": "a8e0c57648d0b66e61c3f7303fff5049-1", "date": "2024-09-26T02:18:28-04:00", "title": "\u00cdtem 50; Especificaciones t\u00e9cnicas", "description": "En general las EE.TT. son de un microscopio quir\u00fargico del tipo usado en Neuro u ORL (por ejemplo por el joystick multifuncional), sin embargo en el punto 3.6.5 se solicitan filtros naranja (usados en odontolog\u00eda) y azul cobalto (usado en oftalmolog\u00eda). Aclarar por favor, para qu\u00e9 tipo de cirug\u00edas ser\u00eda el equipo y verificar la pertinencia de los filtros solicitados.", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:25:58-04:00"}, {"id": "7142142a7b854e642035b29f373c9712-1", "date": "2024-09-18T14:33:06-04:00", "title": "\u00cdTEM 34 EC\u00d3GRAFO", "description": "Se solicita a la convocante admitir transductor lineal con ancho de banda de 3 a 14 MHz, para dar mayor participaci\u00f3n a oferentes.", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:23:24-04:00"}, {"id": "44f42b89f4b58cf657c9ac97eba4c08b-1", "date": "2024-09-13T16:32:53-04:00", "title": "Item N\u00b0 37 \u2013 EETT.", "description": "Solicitamos amablemente a la convocante donde dice: \u201cPunto 2.16 \u2013 Temperatura de dializado de 30.0 \u00b0C a 40.0 \u00b0C\u201d, poder ofertar equipos con un rango de 33.0 \u00b0C a 40.0 \u00b0C ya que esto no afectar\u00eda al tratamiento, ya que la temperatura ideal en los est\u00e1ndares internacionales para un correcto dializado es de 35.5 \u00b0C.", "answer": "Se aclara que esta dentro del rango solicitado.", "dateAnswered": "2024-09-26T07:14:03-04:00"}, {"id": "c14cda45b73add2a3bb439f540de0307-1", "date": "2024-09-17T15:20:20-04:00", "title": "Item 34", "description": "punto 6.2.23 donde dice:\nAjuste continuo autom\u00e1tico de escala de grises sin necesidad de tocar repetidamente el boton de ajuste\nSolicitamos solo agregar lo indispensable ya que solo pide Doppler pulsado y no continuo eliminar CW", "answer": "Remitirse a la Adenda en el SICP.", "dateAnswered": "2024-09-26T07:15:04-04:00"}, {"id": "cfb4abe825a019ebc05d9882bdf1ad60-1", "date": "2024-09-17T17:27:48-04:00", "title": "\u00edtem 33 de las Especificaciones T\u00e9cnicas", "description": "En relaci\u00f3n con Item 33 de las Especificaciones t\u00e9cnicas donde se solicita \u201c Cine memory de al menos 9000 cuadros\u201d solicitamos a la convocante la modificaci\u00f3n de este \u00edtem por \u201c Cine memory de al menos 2000 cuadros\u201d ,este ajuste permite cumplir con los est\u00e1ndares del mercado actual y  facilita la participaci\u00f3n de un mayor n\u00famero de oferentes adem\u00e1s de optimizar el costo del equipo, asegurando un proceso de adquisici\u00f3n m\u00e1s eficiente y competitivo.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:15:36-04:00"}, {"id": "fa65676c30663ec11f357082c8f123cd-1", "date": "2024-09-18T14:32:28-04:00", "title": "\u00edtem 48 Mesa quir\u00fargica", "description": "1.1.14 Carga total de peso de paciente 280kg \u00b1 30 kg\nConsiderando que entre los accesorios se solicitan extensores para pacientes obesos (#1.3.11), creemos que el peso m\u00ednimo de pacientes deber\u00eda de al menos 400kg, favor verificar.", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:23:03-04:00"}, {"id": "fc86bd3fa1f72799fc102194161d168b-1", "date": "2024-09-18T18:51:25-04:00", "title": "Item 24 \u2013 Cardiodesfibrilador", "description": "En el punto 24 4.5  Conectividad Bluetooth para transmisi\u00f3n de datos de descarga a trav\u00e9s\nde software para PC, solicitamos se permita cotizar como alternativa que los datos se puedan descargar v\u00eda USB a una PC.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:14:09-04:00"}, {"id": "78e6a2dd488cb26bd67bf1582c459c8b-1", "date": "2024-09-18T18:26:31-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 34. Punto 4.6", "description": "\"Posibilidad de visualizar im\u00e1genes almacenadas en el equipo a trav\u00e9s de la pantalla t\u00e1ctil para realizar comparaciones con la imagen en la pantalla principal y seguimiento de estudios\" Solicitamos reconsiderar el requerimiento de visualizar im\u00e1genes almacenadas en el equipo a trav\u00e9s de la pantalla t\u00e1ctil para realizar comparaciones. Consideramos que esta funcionalidad es una opci\u00f3n m\u00e1s que una necesidad, ya que la comparaci\u00f3n de estudios en la pantalla principal es igualmente eficaz y garantiza una visualizaci\u00f3n m\u00e1s amplia y clara de las im\u00e1genes, lo cual es crucial para la precisi\u00f3n diagn\u00f3stica. Proponemos que esta \nfuncionalidad sea opcional y que la comparaci\u00f3n en la pantalla principal sea aceptable para no limitar la participaci\u00f3n de equipos que cumplen con altos est\u00e1ndares de calidad pero no cuentan con esta caracter\u00edstica espec\u00edfica", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:11:55-04:00"}, {"id": "74da6b19c2b7d4509a8b9a5438a4ef88-1", "date": "2024-09-18T21:31:03-04:00", "title": "Especificaciones T\u00e9cnicas - Cajas de Cirug\u00eda", "description": "Para todos los \u00edtems de Cajas de Cirug\u00eda en donde menciona el punto:  Se aceptar\u00e1 una variaci\u00f3n de 2+/-cm en las medidas de los instrumentales.\n\u00bfFavor aclarar si es m\u00e1s menos 2 cm sobre las \u00faltimas medidas de las especificaciones? \nEjemplo de 12 a 14 cm ser\u00e1 desde 10 cm hasta 16 cm?", "answer": "Respondido en la consulta 82.", "dateAnswered": "2024-09-26T08:27:34-04:00"}, {"id": "d7be46fc8f6f1858cbcbad66446dfcd0-1", "date": "2024-09-18T21:18:50-04:00", "title": "\u00cdtem 42: Ventilador pulmonar de alta complejidad.", "description": "El PBC solicita Nebulizador con tecnolog\u00eda de malla vibratoria o ultras\u00f3nico. Adaptadores de v\u00edas a\u00e9reas para nebulizaci\u00f3n 5 (cinco) por cada equipo. Reservorio para el medicamento de la nebulizaci\u00f3n 2 (dos) por cada equipo.Se solicita amablemente a la convocante permitir cotizar equipo, sin ir en detrimento de lo solicitado, y permitir la competencia de marcas con experiencia comprobada en el mercado local, por lo que planteamos la siguiente reformulacion del requisito: Nebulizador con tecnolog\u00eda de malla vibratoria o ultras\u00f3nico o neum\u00e1tico controlado electr\u00f3nicamente. Adaptadores de v\u00edas a\u00e9reas para nebulizaci\u00f3n 5 (cinco) por cada equipo. Reservorio para el medicamento de la nebulizaci\u00f3n 2 (dos) por cada equipo", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:27:26-04:00"}, {"id": "1841741e83d303c8b1749507a8736ece-1", "date": "2024-09-18T17:42:49-04:00", "title": "\u00cdtem 42 \u2013 Ventilador Pulmonar de Alta Complejidad", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 4.22 se solicita \u201cNebulizador con tecnolog\u00eda de malla vibratoria o ultras\u00f3nico.\u201d solicitamos a la Convocante pueda modificar este punto por \u201cNebulizador integrado sincronizado\u201d de manera a poder ajustarse a las tecnolog\u00edas disponibles en el mercado ya que cada marca cuenta con su propia tecnolog\u00eda en nebulizaci\u00f3n cumpliendo con el mismo objetivo. Con esta modificaci\u00f3n se estar\u00eda posibilitando la participaci\u00f3n de m\u00e1s oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:33:35-04:00"}, {"id": "75903e1a166faa9ef5bf76fe956994f9-1", "date": "2024-09-18T21:02:58-04:00", "title": "\u00cdtem 37: Equipo para tratamiento de hemodi\u00e1lisis", "description": "El PBC solicita SISTEMA DE PREPARACI\u00d5N DE DIALIZADO Sistema cerrado mediante c\u00e1mara de balance y bombas de pist\u00f3n cer\u00e1mico.Se solicita amablemente a la convocante que, de manera a permitir la competencia de marcas de gran reconocimiento a nivel mundial y experiencia comprobada en el mercado local, las cuales cuentan con sistemas volum\u00e9tricos precisos de succi\u00f3n de concentrados y remoci\u00f3n de l\u00edquido programado, por lo que planteamos la siguiente reformulacion del requisito: SISTEMA DE PREPARACI\u00d5N DE DIALIZADO Sistema cerrado mediante c\u00e1mara de balance y bombas de pist\u00f3n cer\u00e1mico o bombas con mecanismo de membrana, a fin de brindar mayor oportunidad de participacion a los oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:27:03-04:00"}, {"id": "3e0eee5e8db88c46c9e391a463cb8ebc-1", "date": "2024-09-23T14:57:43-04:00", "title": "SOPORTE TECNICO", "description": "ITEM 35 En el punto 3.6 Soporte t\u00e9cnico durante el tiempo de duraci\u00f3n de la garant\u00eda. Presentar declaraci\u00f3n jurada\nSolicitamos a la convocante pueda ser modificada este criterio de la siguiente manera: Soporte t\u00e9cnico durante el tiempo de duraci\u00f3n de la garant\u00eda del bien ofertado.  Presentar declaraci\u00f3n jurada.", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:24:02-04:00"}, {"id": "c2faaa1b10c2ad9a3be2dcd728fd5b45-1", "date": "2024-09-18T22:37:27-04:00", "title": "ID 443857 - \u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \"El equipo debe trabajar con rangos de frecuencias de 1 a 22 MHz o mayor\" La diferencia solicitada es m\u00ednima, adem\u00e1s, dicho par\u00e1metro es est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos se actualice este punto a fin de tener la participaci\u00f3n de las marcas con reconocida representaci\u00f3n y comprobada calidad en el mercado local e internacional. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:35:54-04:00"}, {"id": "2973237faa4091c9739a01ec13b5f494-1", "date": "2024-09-14T11:29:51-04:00", "title": "EXPERIENCIA REQUERIDA", "description": "FAVOR EXCLUIR LO SIGUIENTE:\n\n (EL OFERENTE DEBER\u00c1 PRESENTAR DOCUMENTOS QUE CERTIFIQUEN SU EXPERIENCIA EN LA PROVISI\u00d3N DEL BIEN QUE COTIZA EN ESTA CONTRATACI\u00d3N)\n\nEl requisito es inaplicable e improcedente, debido a que los oferentes con vasta experiencia en provisi\u00f3n de equipos m\u00e9dicos, podr\u00edan no haber provisto el mismo equipo que cotiza en el presente llamado. Adem\u00e1s, al momento de la evaluaci\u00f3n se corre el riesgo de que la evaluaci\u00f3n no sea objetiva, porque podr\u00edan considerar que la experiencia en provisi\u00f3n de un equipo similar no lo acredita para cumplir el requisito.\n\nFavor excluir el requisito, y mantener la experiencia en provisi\u00f3n de equipos m\u00e9dicos en general, de manera a no establecer condiciones no indispensables y comprometer la objetividad de la evaluaci\u00f3n, en contraposici\u00f3n al principio de igualdad y libre competencia.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:14:45-04:00"}, {"id": "bc912e17b02570a7beaf16f77fce9a61-1", "date": "2024-09-18T19:40:37-04:00", "title": "Item 42 Ventilador Pulmonar", "description": "En el punto 4.2 donde dice \u201cVol\u00famen Corriente (ml). L\u00edmite inferior 1,5 \u00b1 0,5. L\u00edmite superior 3200 \u00b1 200\u201d solicitamos amablemente a la convocante permita la cotizacion de equipos con l\u00edmite superior de al menos 2500 mL, y asi dar participaci\u00f3n de potenciales oferetnes. Asi tambien cambiar el limite inferior considerando que vol\u00famenes de 1.5 mL solo se da en neonatos y el valor usual aplicable a pacientes adultos de 40 mL. En ese sentido solicitamos que el item quede de la siguiente manera: \u201cVol\u00famen Corriente (ml). L\u00edmite inferior 40 \u00b1 0,5. L\u00edmite superior 2500 \u00b1 200\u201d.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:18:16-04:00"}, {"id": "4581cd2ee54a789271a5f290b0b231e4-1", "date": "2024-09-18T18:51:22-04:00", "title": "Item 19 \u2013 Caja de curaci\u00f3n", "description": "Donde solicitan: Certificaci\u00f3n de la calidad de los instrum\u00e9ntales: DIM EN 10088T.1-3, EN ISO 7153-1 , y EN ISO 13485:2016, por favor aclarar que se requiere alguno de ellos.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:13:59-04:00"}, {"id": "a951f54fa51c0f61b51f2ad751f8cdd3-1", "date": "2024-09-18T20:48:38-04:00", "title": "\u00cdtem 37: Equipo para tratamiento de hemodi\u00e1lisis", "description": "El PBC solicita Software de diagn\u00f3stico con gr\u00e1ficas interactivas en la pantalla.Se solicita amablemente a la convocante permitir cotizar equipos que cuenten con software de diagn\u00f3stico para poder evaluar y determinar anomal\u00edas en el funcionamiento de los subsistemas de la m\u00e1quina. La utilizaci\u00f3n de graficas interactivas, aunque \u00fatiles no deben ser excluyentes a la hora de determinar malfuncionamiento del equipo.\nDe manera a permitir la competencia de marcas de gran reconocimiento a nivel mundial y experiencia comprobada en el mercado local, por lo que planteamos la siguiente reformulacion del requisito: Software de diagn\u00f3stico, a fin de brindar mayor oportunidad de participacion a los oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:19:48-04:00"}, {"id": "30c7b8a6f0ffb7593dccf4dd810e73ed-1", "date": "2024-09-18T18:52:50-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 33. 2.20", "description": "\u201cCine Memory de al menos 9000 cuadros\u201d Solicitamos a la convocante reconsiderar la especificaci\u00f3n de una Cine Memory de al menos 9000 cuadros. Esta cantidad est\u00e1 generalmente destinada a equipos de muy alta gama, lo que incrementa considerablemente el costo del equipo, lo cual no concuerda con el precio referencial establecido en el pliego. Sugerimos considerar un rango a partir de 1000 cuadros, que es suficiente para el almacenamiento eficiente de im\u00e1genes en la mayor\u00eda de las aplicaciones, permitiendo un equilibrio entre funcionalidad y costo.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:15:35-04:00"}, {"id": "283341458f7e036103abf728aade8ad6-1", "date": "2024-09-18T14:18:44-04:00", "title": "\u00cdtem 25", "description": "1.2 Con SpO2, CO2 y carro de paro para unidad de cuidados cr\u00edticos para pacientes Neonatales\n\u00bfPodr\u00edan aclarar si se debe entregar un carro de paro por cada desfibrilador? Creemos que nn el \u00edtem 26 se solicitan los carros de paro para uso con estos equipos.", "answer": "Se aclara que se debe entregar un carro por cada equipo.", "dateAnswered": "2024-09-26T07:19:54-04:00"}, {"id": "55c5a7f44d536c27d5646d33c9eb483f-1", "date": "2024-09-18T17:43:01-04:00", "title": "\u00cdtem 42 \u2013 Ventilador Pulmonar de Alta Complejidad", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 6.21 se solicita \u201cPresi\u00f3n inspiratoria negativa 0 a -60 cmH2O\u201d solicitamos a la Convocante pueda modificar este punto por \u201cPresi\u00f3n inspiratoria negativa o NIF de 0 a -45 cmH2O o mejor rango\u201d de manera a ajustarse a los valores normales de este par\u00e1metro y no limitar los mismos. Esta modificaci\u00f3n permite la participaci\u00f3n de m\u00e1s oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:33:51-04:00"}, {"id": "48b70679d3e31fd6c1f6691d93530bb1-1", "date": "2024-09-18T22:23:00-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Donde dice \"Pantalla t\u00e1ctil integrada para acceso al men\u00fa secundario de 13 o superior con ajuste de brillo y resoluci\u00f3n de al menos 1920x1080, que permita el manejo interactivo del men\u00fa, para acceso a modos de operaci\u00f3n, aplicaciones y configuraciones\" solicitamos a la convocante modificar este punto a \"Pantalla t\u00e1ctil integrada para acceso al men\u00fa secundario de 10\" o superior con ajuste de brillo y resoluci\u00f3n de al menos 1024x768, que permita el manejo interactivo del men\u00fa, para acceso a modos de operaci\u00f3n, aplicaciones y configuraciones.\" La diferencia solicitada es m\u00ednima, adem\u00e1s, lo solicitado constituye una caracter\u00edstica meramente constructiva que no afecta a la calidad de imagen. Por lo que solicitamos que modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:33-04:00"}, {"id": "3563f24a1eb4ba953e5b64379ff6162b-1", "date": "2024-09-18T18:53:44-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 33. Punto 2.21", "description": "\u201cProfundidad de imagen m\u00e1xima de 44 cm o mayor\u201d Solicitamos a la convocante considerar una modificaci\u00f3n en el requisito de profundidad de imagen m\u00e1xima de 44 cm a una profundidad m\u00ednima de 30 cm. Un rango de profundidad a partir de 30 cm es suficiente para la mayor\u00eda de las aplicaciones cl\u00ednicas y permite que equipos con caracter\u00edsticas avanzadas, pero con una profundidad de imagen m\u00e1s moderada tambi\u00e9n puedan participar en la licitaci\u00f3n. Esta modificaci\u00f3n ayudar\u00eda a equilibrar las especificaciones con el presupuesto referencial y a permitir una mayor competencia entre los oferentes", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:16:07-04:00"}, {"id": "069965606d1e48ed7898cdc519f215c7-1", "date": "2024-09-18T17:51:54-04:00", "title": "\u00cdTEM 35 EC\u00d3GRAFO", "description": "8.5 Se solicita a la convocante admitir Transductor Phased Array de cristal \u00fanico con un ancho de banda de 1,5 MHz-4,5 MHz.Para dar mayor participaci\u00f3n a oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:11:25-04:00"}, {"id": "edd7c830eaecdec18d999327c4fb434a-1", "date": "2024-09-18T15:24:52-04:00", "title": "Capacidad T\u00e9cnica", "description": "La convocante en el punto 8 solicita. Certificado de Registro Sanitario, de conformidad a la Ley N\u00ba 4959/12, teniendo en cuenta de que existe \u00edtems que son para uso laboratorio como por ejemplo, \u00edtem N\u00b0 28 y 40 y los mismos se encuentran regidos y excluidos por la Resoluci\u00f3n N\u00b0 266/2022 \u2013 Art 13. Solicitamos aclarar que para dichos \u00edtems no se precisara del Registro Sanitario.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:24:14-04:00"}, {"id": "277334187bf3f4eb5132f9bf0d18042f-1", "date": "2024-09-18T19:30:15-04:00", "title": "Item 42 Ventilador Pulmonar", "description": "En el \u00cdtem 42 Ventilador pulmonar de alta complejidad: En el punto 10.9 solicitan Sensor de SpO2 tipo pinza reutilizable de la misma marca que el ventilador., claramente se observa que estas especificaciones t\u00e9cnicas son de la marca nihon kohden, que ellos son los \u00fanicos que tiene de la misma marca, por lo tanto solicitamos que este punto sea opcional y considerando que cada proveedor terceriza con tecnolog\u00eda de confianza como Tecnolog\u00eda M\u00e1ximo, Nellcor, etc", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:17:33-04:00"}, {"id": "91ec4995e1aead3800332f7217ec739b-1", "date": "2024-09-18T22:35:17-04:00", "title": "ID 443857 - \u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Resoluci\u00f3n de pantalla de 1920 x 1080\" solicitamos a la convocante modificar este punto a \"Resoluci\u00f3n de pantalla de 1280 x 800 o mejor\" La diferencia solicitada es m\u00ednima, adem\u00e1s, dicho par\u00e1metro es est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos se actualice este punto a fin de tener la participaci\u00f3n de las marcas con reconocida representaci\u00f3n y comprobada calidad en el mercado local e internacional. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:35:18-04:00"}, {"id": "6f562fdf9807af82cba9fdea291166f0-1", "date": "2024-09-18T22:26:19-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Donde dice \"Evaluaci\u00f3n hemodin\u00e1mica con alta sensibilidad y alta resoluci\u00f3n espacial para el examen de micro-vascularizaci\u00f3n no invasiva\" solicitamos a la convocante considerar este punto como OPCIONAL debido a que esta caracter\u00edstica encarece significativamente el precio referencial del ecocardi\u00f3grafo requerido.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:29:04-04:00"}, {"id": "545caaf90d79838a66926789de181368-1", "date": "2024-09-18T17:45:05-04:00", "title": "\u00cdtem 45 \u2013 M\u00e1quina de Anestesia", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 7.2 se solicita \u201cDisplay: de m\u00ednimo de 15 pulgadas, tipo touchscreen (T\u00e1ctil). Tecnolog\u00eda LCD/TFT de alta resoluci\u00f3n. Trazados: 15 curvas fisiol\u00f3gicas de forma simult\u00e1nea\u201d solicitamos a la Convocante pueda modificar este punto por \u201cDisplay: de m\u00ednimo de 12 pulgadas, tipo touchscreen (T\u00e1ctil). Tecnolog\u00eda LCD/TFT de alta resoluci\u00f3n. Trazados: 10 curvas fisiol\u00f3gicas de forma simult\u00e1nea\u201d De manera a poder ajustar la oferta al precio referencial unitario, tambien se debe tener en cuenta que ya se solicita una pantalla amplia para la m\u00e1quina de anestesia, por lo que la pantalla del monitor ser\u00e1 solo para par\u00e1metros hemodin\u00e1micos.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:10:40-04:00"}, {"id": "b421b1a3600f85ef6b499aaeca714608-1", "date": "2024-09-18T18:40:51-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 33 Punto 2.19", "description": "Solicitamos a la convocante aclarar el requerimiento de \"6600 Hz de frame rate\", ya que el frame rate en sistemas de ultrasonido generalmente no se mide en Hertzios (Hz). Usualmente, el frame rate se expresa en cuadros por segundo (fps). Agradecer\u00edamos una revisi\u00f3n de la especificaci\u00f3n para asegurar que se indique correctamente la unidad de medida, y para evitar posibles confusiones en la interpretaci\u00f3n del requerimiento.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:12:11-04:00"}, {"id": "c2221f0f92a3fbc2248f36dea644d452-1", "date": "2024-09-18T19:14:55-04:00", "title": "item 20 Cama electrica", "description": "En el Item 20 Cama el\u00e9ctrica para paciente: en el punto 4.3 solicitan con longitud m\u00e1xima de 225 cm +/- 5cm, solicitamos a la convocante poder cotizar camas con dimensiones 222 cm +/-5 cm.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:16:31-04:00"}, {"id": "754b6936940dbd5e759ceced27fcdea6-1", "date": "2024-09-18T18:26:34-04:00", "title": "Plazo de reposici\u00f3n de bienes", "description": "Donde dice: El plazo de reposici\u00f3n de bienes para reparar o reemplazar ser\u00e1 de: De 5 (cinco) d\u00edas h\u00e1biles posterior a la comunicaci\u00f3n al proveedor.\nSolicitamos modificar por El plazo de reposici\u00f3n de bienes para reparar o reemplazar ser\u00e1 de: De 15 (quince) d\u00edas h\u00e1biles posterior a la comunicaci\u00f3n al proveedor.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:12:00-04:00"}, {"id": "b6e056c23736975fb78168eb266cf82f-1", "date": "2024-09-18T22:21:52-04:00", "title": "Embalajes y documentos", "description": "Donde dice \"El embalaje, la identificaci\u00f3n y la documentaci\u00f3n dentro y fuera de los paquetes ser\u00e1n como se indican a continuaci\u00f3n: Cada equipo y/o accesorio deber\u00e1 tener grabado a laser USO EXCLUSIVO DEL HOSPITAL DE CLINICAS\" solicitamos a la convocante excluir de este requerimiento a los accesorios correspondientes a los \u00edtems 33, 34, 35 y 38. Esta solicitud se fundamenta en que el grabado l\u00e1ser podr\u00eda afectar la funcionalidad  y la calidad de los accesorios (transductores, tubo de rayos X) de los ec\u00f3grafos y equipos de rayos X. Por lo que solicitamos se considere esta excepci\u00f3n a fin de garantizar la adecuada utilizaci\u00f3n de dichos equipos.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:21-04:00"}, {"id": "b18881880cb8119a664cda2091277b68-1", "date": "2024-09-17T17:42:52-04:00", "title": "ITEM 35", "description": "En el \u00edtem 35 de las especificaciones t\u00e9cnicas donde dice \u201cMonitor de alta resoluci\u00f3n LED Wide Screen Full HD de 18 \u00b13\", solicitamos a la convocante la modificaci\u00f3n de este \u00edtem por \u201cMonitor de alta resoluci\u00f3n LED de alta resoluci\u00f3n de 15\u201d o mejor\u201d, Esta modificaci\u00f3n est\u00e1 alineada con los est\u00e1ndares del mercado para equipos port\u00e1til y permitir\u00e1 una mayor apertura a potenciales oferentes, promoviendo una competencia m\u00e1s amplia y evitando la limitaci\u00f3n a una sola marca", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:16:20-04:00"}, {"id": "ea902f7987e7d01f6339612f173c6677-1", "date": "2024-09-18T20:56:25-04:00", "title": "\u00cdtem 37: Equipo para tratamiento de hemodi\u00e1lisis", "description": "El PBC solicita FLUJO DE DIALIZADO 300 a 700 mL/min (est\u00e1ndar: 500mL/min). En incrementos de 100 mL/min. Se solicita amablemente a la convocante que, de manera a permitir la competencia de marcas de gran reconocimiento a nivel mundial y experiencia comprobada en el mercado local, por lo que solicitamos sean aceptados equipos con FLUJO DE DIALIZADO 300 a 700 o mayor (mL/min) (est\u00e1ndar: 500mL/min). En incrementos de 100 mL/min \u00f3 con selecci\u00f3n de factor de flujo de dializado adaptado al flujo de sangre QB seteado, a fin de brindar mayor oportunidad de participacion a los oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:26:57-04:00"}, {"id": "2bf7b949810f42c141b85296a45de11b-1", "date": "2024-09-18T14:18:32-04:00", "title": "\u00cdtem 16 Monitor Multiparam\u00e9trico", "description": "7.7 (dos) sistemas EEG de 8 canales por la totalidad de equipos.\n\u00bfSe podr\u00eda contizar con sistema EEG de 4 canales por la totalidad de equipos?", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:19:49-04:00"}, {"id": "c79e06bcdc49261897f272c9809a69b8-1", "date": "2024-09-18T18:52:35-04:00", "title": "Item 52 \u2013 Monitor cardiofetal", "description": "52 2.1 Pantalla color de 9\" pulgadas \u00b1 2\", con movimiento de ajuste vertical, y\nmovimiento direccional horizontal. De manera a dar oportunidad a un mayor n\u00famero de oferentes, solicitamos que el movimiento direccional horizontal sea opcional.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:15:25-04:00"}, {"id": "d07e1604df6fab12631d44af9ab7a0d4-1", "date": "2024-09-13T12:15:30-04:00", "title": "\u00cdtem 51  Microscopios de fluorescencia", "description": "\u00cdtem 51  Microscopios de fluorescencia. Establece el PBC en el punto 3.8: Objetivos plan acrom\u00e1ticos 2X,4x,10x,20x,y 40x .\nFavor considerar solicitar sin el objetivo de 2x ya que esto aumentar\u00eda demasiado el costo del equipo, con respecto al precio de referencia.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:09:21-04:00"}, {"id": "843ee6fd4fcb70720dd47e911ef029f5-1", "date": "2024-09-18T09:19:38-04:00", "title": "Especificaciones tecnicas", "description": "SOLICITAMOS a la convocante modifique el punto 4.22 \"Nebulizador con tecnolog\u00eda de malla vibratoriao ultrasonico\", a Nebulizador con tecnolog\u00eda de malla vibratoriao ultrasonico o neum\u00e1tica ya que esta modificaci\u00f3n no afecta la calidad y eficacia de los tratamientos realizados, ademas de no limitar la participaci\u00f3n. Caso contrario nos veremos en la necesidad de realizar una protesta en la que vamos a mencionar la marca y el modelo a que corresponde estas especificaciones que limitan la participaci\u00f3n", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:17:38-04:00"}, {"id": "ec06e827740c4d11fea12badb0c384f2-1", "date": "2024-09-18T14:17:54-04:00", "title": "\u00cdtem 10 Caja de cirug\u00eda especializada", "description": "2.39 1 MANGO BISTUR\u00cd NO. 4 LARGO, de 15 a 16 cm de longitud\n\u00bfEs correcta la medida solicitada, no deber\u00eda ser de 20 a 21cm de longitud?", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:19:32-04:00"}, {"id": "d038c5a0b0bc7d6335179e0e1a19f2bd-1", "date": "2024-09-25T22:13:01-04:00", "title": "EETT ITEM 23. 2.9", "description": "En relaci\u00f3n con la especificaci\u00f3n de \"Altura de 80 cm \u00b1 5 cm\", solicitamos a la convocante considerar ajustar las especificaciones a 85 cm \u00b1 5 cm. Este ajuste facilitar\u00eda una mejor integraci\u00f3n con otros equipos m\u00e9dicos, optimizando el flujo de trabajo y la eficiencia durante los procedimientos\u00a0cl\u00ednicos", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:25:55-04:00"}, {"id": "4529cce40f7083fdec03700828bfe3b7-1", "date": "2024-09-13T12:15:23-04:00", "title": "Especificaciones t\u00e9cnicas. \u00cdtem 50  Microscopio \u00d3ptico", "description": "\u00cdtem 50:  Microscopio \u00f3ptico\nFavor indicar si ser\u00eda un microscopio quir\u00fargico lo que se requiere", "answer": "Afirmativo.", "dateAnswered": "2024-09-26T07:09:14-04:00"}, {"id": "32132043caa6b4b9cd8116ea7acc8b32-1", "date": "2024-09-18T20:44:36-04:00", "title": "\u00cdtem 37: Equipo para tratamiento de hemodi\u00e1lisis", "description": "El PBC solicita Pantalla LCD a color de 14 pulgadas \u00b1 2\" con panel sensible al tacto. Se solicita amablemente a la convocante, y sin ir en detrimento de lo solicitado, permitir cotizar equipos que cuenten con pantallas de al menos 10\u201d, cuyo tama\u00f1o resulta suficiente para poder desplegar datos, par\u00e1metros, configuraciones y graficas del tratamiento, adem\u00e1s de permitir la competencia de marcas de gran reconocimiento a nivel mundial y experiencia comprobada en el mercado local, por lo que planteamos la siguiente reformulacion del requisito: Pantalla LCD a color de al menos 10 pulgadas con panel sensible al tacto o teclado para operaci\u00f3n del equipo, a fin de brindar mayor oportunidad de participacion a los oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:18:32-04:00"}, {"id": "772038691889c1985ec21a1cba3defc3-1", "date": "2024-09-25T17:27:17-04:00", "title": "ESPECIFICACIONES TECNICAS - ITEM 21. 4.3.2", "description": "Donde se solicita \"Ancho m\u00e1ximo 110 cm \u00b1 5 cm\", solicitamos a la convocante considerar ajustar la especificaci\u00f3n de ancho m\u00e1ximo de la cama a 100 cm \u00b1 5 cm. Esta medida sigue siendo adecuada para la mayor\u00eda de los entornos cl\u00ednicos y permite una mayor flexibilidad en la oferta de equipos, sin comprometer la comodidad o funcionalidad necesaria para los cuidados cr\u00edticos", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:24:51-04:00"}, {"id": "a99a6187a05f4816caf76f14c488002c-1", "date": "2024-09-18T19:14:42-04:00", "title": "Plan de entrega de los bienes", "description": "En el apartado de Plan de entrega de los bienes se expresa: \u201cEl 100 % dentro de los 30 d\u00edas a partir de la firma del contrato en el Dto. de Suministros del HC San Lorenzo CP Lilian Suarez de lunes a viernes de 08: a 12:00 hs.\u201d Se solicita amablemente a la convocante, extender el plazo en 90 d\u00edas corridos, posteriores a la recepci\u00f3n de la orden de compra. Esta solicitud se fundamenta en los tiempos requeridos para la fabricaci\u00f3n, log\u00edstica de importaci\u00f3n y tr\u00e1mites de despacho en aduana, que f\u00e1cilmente podr\u00eda exceder los 2 meses. Adem\u00e1s, esto garantizara que todos los oferentes compitan en igualdad de condiciones, evitando que se favorezca a aquellos proveedores que ya disponen de los productos solicitados en stock, y asegurando as\u00ed un proceso de selecci\u00f3n justo para todos los participantes. Por lo expuesto, solicitamos que dicha solicitud quede redactada de la siguiente manera: \u201cEl 100 % dentro de los 90 (noventa) d\u00edas a partir de la firma del contrato en el Dto. de Suministros del HC San Lorenzo CP Lilian Suarez de lunes a viernes de 08: a 12:00 hs.\u201d", "answer": "Remitirse a la respuesta de la consulta 1.", "dateAnswered": "2024-09-26T08:16:20-04:00"}, {"id": "31e3ef7d4d826706cf090f5a0cd4db4e-1", "date": "2024-09-19T06:56:45-04:00", "title": "item 42 Ventilador", "description": "\u2022\tSolicitan Pantalla secundaria para control y monitorizaci\u00f3n del ventilador de 19\" \u00b1 2\". Conexi\u00f3n a la pantalla principal al\u00e1mbrica o inal\u00e1mbrica. Una (1) unidad por la totalidad de equipos incluyendo el carro para la pantalla secundaria. Solicitamos diga: Pantalla secundaria para monitorizaci\u00f3n del ventilador de 19\" \u00b1 2\". Conexi\u00f3n a la pantalla principal al\u00e1mbrica o inal\u00e1mbrica. Una (1) unidad por la totalidad de equipos incluyendo el carro para la pantalla secundaria. No se recomienda que se pueda tener control de los ventiladores por medio de las pantallas secundarias ya que esto puede causar cambiar los valores del paciente por accidente o modificar par\u00e1metros sin estar con el paciente", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:37:11-04:00"}, {"id": "f8cee81371812bbd237d40398378101f-1", "date": "2024-09-14T11:30:04-04:00", "title": "ESPECIFICACIONES T\u00c9CNICAS \u2013 \u00cdTEMS 1  - ITEM 14 \u2013 ITEM 19", "description": "DONDE DICE:\n\nOtros requerimientos:\n\n\u201cDeber\u00e1 presentar carta garant\u00eda original del fabricante\u2026\u201d\n\nFavor aclarar a qu\u00e9 se refiere con garant\u00eda original y confirmar si debe presentarse una vez adjudicado, porque no puede presentarse una garant\u00eda de un bien que no se entreg\u00f3.\nSe consulta si la Garant\u00eda remitida por f\u00e1brica de manera digital, con firma y membrete ser\u00e1 considerada como v\u00e1lida.", "answer": "Ajustarse a lo solicitado en el PBC. Se aclara que se presenta una vez adjudicado.", "dateAnswered": "2024-09-26T07:14:48-04:00"}, {"id": "edab8cbd4c6e467ab97962b01b2e6900-1", "date": "2024-09-18T17:01:31-04:00", "title": "ITEM 1 1 2.3 Pedestal M\u00f3vil del mismo fabricante, con manijas de empu\u00f1adura, montado en estructura met\u00e1lica (pedestal)", "description": "Para este punto, se solicita a la convocante aceptar equipo tipo modular con empu\u00f1adura y ruedas..", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:27:53-04:00"}, {"id": "aa35b245f751e57527ed742042082c14-1", "date": "2024-09-18T17:43:56-04:00", "title": "\u00cdtem 44 \u2013 M\u00e1quina de Anestesia", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 5.6 se solicita \u201cDespliegue de curvas de presi\u00f3n vs. Tiempo y volumen vs. Tiempo, al menos cinco curvas en simultaneo en la pantalla de ventilaci\u00f3n.\u201d solicitamos a la Convocante pueda modificar este punto por \u201cDespliegue de curvas de presi\u00f3n vs. Tiempo y volumen vs. Tiempo, al menos tres curvas en simultaneo en la pantalla de ventilaci\u00f3n.\u201d Esto debido a que en todas las especificaciones no se solicita la visualizaci\u00f3n de mas de estas dos curvas, por lo que no tiene sentido solicitar el despliegue de CINCO curvas. Tambien se debe tener en cuenta que el equipo solicitado es un equipo de mediana complejidad.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:10:02-04:00"}, {"id": "709f78f0a1ec377822320b0ea1cde40e-1", "date": "2024-09-18T22:31:01-04:00", "title": "ID 443857 - \u00cdtem 34 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Software para detecci\u00f3n autom\u00e1tica de translucencia nucal\" solicitamos a la convocante modificar este punto a \"Software para detecci\u00f3n autom\u00e1tica o manual de translucencia nucal\" lo solicitado no afectar\u00e1 la funcionalidad solicitada para este punto, adem\u00e1s lo solicitado es el est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda, por lo que solicitamos modificar este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:34:49-04:00"}, {"id": "611299d5d3ed44b9d5caccd10ce8b986-1", "date": "2024-09-18T22:02:43-04:00", "title": "Item 42 Ventilador Pulmonar", "description": "En el punto 6.15 donde dice \u201cRespiraci\u00f3n r\u00e1pida superficial RSBI 0 a 9999 bpm/l\u201d solicitamos a la convocante permita cotizar equipos con Respiraci\u00f3n r\u00e1pida superficial RSBI en el rango de 1 a 9999, y as\u00ed dar participaci\u00f3n a potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:27:45-04:00"}, {"id": "9a4d9d5b0f9cb50e5e6ff98d8995b33a-1", "date": "2024-09-18T16:06:16-04:00", "title": "item 25", "description": "Donde dice: 4.5 Conectividad Bluetooth para transmisi\u00f3n de datos de descarga a trav\u00e9s de software para PC.\nSolicitamos diga: 4.5 Conectividad Bluetooth o Wireless para transmisi\u00f3n de datos de descarga a trav\u00e9s de software para PC", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:26:27-04:00"}, {"id": "5665ac95b8e16a24ab3abe1266fa6265-1", "date": "2024-09-18T18:52:19-04:00", "title": "Item 36 \u2013 Electrocardiografo", "description": "36 5.13 4 puertos de USB como m\u00ednimo. Solicitamos se puedan cotizar equipos con un puerto USB, esto no afecta de ninguna manera a la adquisici\u00f3n del ECG.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:14:37-04:00"}, {"id": "943b47bafd774827e5d08fa11dc294e4-1", "date": "2024-09-18T14:52:20-04:00", "title": "Especificaciones T\u00e9cnicas", "description": "En la Pg. 98 del PBC, \u00edtem 37 punto 3.2 establece que: \u201cManuales: Un (01) del usuario o de operaci\u00f3n y Un (01) manual t\u00e9cnico por equipo, que ser\u00e1n entregados en el momento de la recepci\u00f3n el equipo. Todos los manuales ser\u00e1n originales del fabricante y no fotocopias ni traducciones\u201d. Solicitamos respetuosamente a la convocante eliminar o considerar la solicitud del manual t\u00e9cnico como opcional, ya que dicho documento contiene informaci\u00f3n sobre calibraciones y ajustes sensibles del equipo que solo pueden ser realizados por un personal t\u00e9cnico certificado por F\u00e1brica, de lo contrario cualquier cambio realizado por terceros pueden poner en riesgo la integridad y seguridad del paciente.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:23:47-04:00"}, {"id": "04b586491f336091c574977a56b37be6-1", "date": "2024-09-18T22:34:23-04:00", "title": "ID 443857 - \u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Para el \u00edtem 35 el PBC establece que el Plan de entrega de los bienes ser\u00e1: \"El 100 % dentro de los 30 d\u00edas a partir de la firma del contrato\" Favor solicitamos a la convocante modificar este punto a \"El 100 % dentro de los 90 d\u00edas posteriores a la recepci\u00f3n de la orden de compra por parte del proveedor\".  Lo solicitado obedece en su mayor\u00eda se trata de equipos cuya fabricaci\u00f3n se realiza tras un pedido al fabricante mediante orden de compra, y que posteriormente son importados, por lo que el plazo debe indefectiblemente incluir tiempo de transporte internacional y los procesos aduaneros realizados por terceros.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:35:08-04:00"}, {"id": "0c989c43a8f0ef6e35a5edad630c8582-1", "date": "2024-09-25T17:33:06-04:00", "title": "ESPECIFICACIONES TECNICAS - ITEM 20. 5.1", "description": "Donde se solicita \"Altura ajustable el\u00e9ctricamente (medido de la plataforma de la cama al piso, sin colch\u00f3n). Altura m\u00ednima 55 cm \u00b1 5 cm, Altura m\u00e1xima 85 cm \u00b1 5 cm\", solicitamos a la convocante considerar ajustar la altura m\u00ednima a 40 cm \u00b1 5 cm y la altura m\u00e1xima a 80 cm \u00b1 5 cm. Este ajuste proporcionar\u00eda mayor flexibilidad en el manejo de la cama, facilitando un mejor acceso para los profesionales de la salud y ofreciendo m\u00e1s comodidad para el paciente en diferentes contextos cl\u00ednicos, sin comprometer la funcionalidad de la cama.", "answer": "Respondido en la Consulta 264.", "dateAnswered": "2024-09-26T14:25:03-04:00"}, {"id": "036cf9c4d83cd88df12047096d5b807f-1", "date": "2024-09-18T17:52:31-04:00", "title": "\u00cdTEM 35 EC\u00d3GRAFO", "description": "4.16 Se solicita a la convocante dejar como opcional el M\u00f3dulo de respiraci\u00f3n integrado con despliegue de curva de respiraci\u00f3n, para dar mayor participaci\u00f3n a oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:11:36-04:00"}, {"id": "da7978083d07ace09f12386ef044da8e-1", "date": "2024-09-18T14:40:26-04:00", "title": "\u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \"El sistema debe ser capaz de medir autom\u00e1ticamente la fracci\u00f3n de eyecci\u00f3n en cortes de 4 c\u00e1maras y 2 c\u00e1maras\" solicitamos a la convocante considerar este punto como OPCIONAL debido a que esta caracter\u00edstica encarece significativamente el precio referencial del ec\u00f3grafo requerido. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:23:38-04:00"}, {"id": "ab3ff1547bd1576d9a3d17856e284d3c-1", "date": "2024-09-18T19:31:07-04:00", "title": "ITEM 38 \u2013 Equipo de rayos x portatil", "description": "En el punto 6.11 donde dice \u201cCarga de 400Kg. distribuida o 200 kg carga localizada o mejor.\u201d Solicitamos amablemente a la convocante permita la cotizacion de equipos con capacidad de carga que se ajuste a los valores de mercado como ser 100 kg de capacidad. Y asi dar participaci\u00f3n de potenciales oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:18:09-04:00"}, {"id": "461c85f8660fecc60bae8372867382c2-1", "date": "2024-09-18T22:03:34-04:00", "title": "Item 42 Ventilador Pulmonar", "description": "En el punto 9.6 donde dice \u201cPantalla LCD de 19 \u00b1 2\". Perilla o botones selectores para ajuste de valores.\u201d  Solicitamos a la convocante permita la cotizaci\u00f3n de equipos con pantallas LCD de 13 pulgadas t\u00e1ctil, no solo que utilice perillas o botones, para de esta manera dar aperturas a las especificaciones t\u00e9cnicas as\u00ed dar participaci\u00f3n a potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:02-04:00"}, {"id": "bce3839bc78b3e8e84054185c28cc32a-1", "date": "2024-09-18T22:33:41-04:00", "title": "ID 443857 - \u00cdtem 34 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Transductor lineal con ancho de banda de 4 MHz o menor a 15 MHz o mayor. Compatible para uso de elastosonograf\u00eda. Cantidad: 01 (uno) por cada equipo\" solicitamos a la convocante modificar este punto a \"Transductor lineal con ancho de banda de 3 MHz o menor a 11.5 MHz o mayor. Compatible para uso de elastosonograf\u00eda. Cantidad: 01 (uno) por cada equipo\" dichos par\u00e1metros son est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos que modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:35:01-04:00"}, {"id": "adab0d32a36dd3cdba0f382c69513e60-1", "date": "2024-09-18T18:28:59-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 34. Puntos 6.2.11", "description": "Software para detecci\u00f3n autom\u00e1tica de translucencia nucal, Software para detecci\u00f3n autom\u00e1tica de translucencia intracraneal\u201d\nsolicitamos que estas caracter\u00edsticas sean opcionales. Dado que se trata de un ec\u00f3grafo multiprop\u00f3sito, la inclusi\u00f3n de este tipo de software especializado en obstetricia y ginecolog\u00eda incrementa considerablemente el costo del equipo. Al ser funcionalidades espec\u00edficas para ciertas aplicaciones, creemos que su obligatoriedad limita la competitividad de posibles oferentes y no es indispensable para un equipo de uso general.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:12:02-04:00"}, {"id": "6d43a503ec67a2506a36bbdb0f02109a-1", "date": "2024-09-25T18:41:31-04:00", "title": "Plan de entrega de los bienes", "description": "En el apartado de Plan de entrega de los bienes se expresa: \u201cEl 100 % dentro de los 30 d\u00edas a partir de la firma del contrato en el Dto. de Suministros del HC San Lorenzo CP Lilian Suarez de lunes a viernes de 08: a 12:00 hs.\u201d Se solicita amablemente a la convocante, extender el plazo en 90 d\u00edas corridos, posteriores a la recepci\u00f3n de la orden de compra. Esta solicitud se fundamenta en los tiempos requeridos para la fabricaci\u00f3n, log\u00edstica de importaci\u00f3n y tr\u00e1mites de despacho en aduana, que f\u00e1cilmente podr\u00eda exceder los 2 meses. Adem\u00e1s, esto garantizara que todos los oferentes compitan en igualdad de condiciones, evitando que se favorezca a aquellos proveedores que ya disponen de los productos solicitados en stock, y asegurando as\u00ed un proceso de selecci\u00f3n justo para todos los participantes. Por lo expuesto, solicitamos que dicha solicitud quede redactada de la siguiente manera: \u201cEl 100 % dentro de los 90 (noventa) d\u00edas a partir de la firma del contrato en el Dto. de Suministros del HC San Lorenzo CP Lilian Suarez de lunes a viernes de 08: a 12:00 hs.\u201d", "answer": "Ajustarse a lo solicitado en el PBC, atendiendo a los plazos, establecidos en la Resoluci\u00f3n DNCP N\u00b0 1430/2024 \"Plazos m\u00e1ximos para comunicar a la DNCP los llamados, adjudicaciones y contratos que afecten a los procesos que comprometan el PGN 2024\", en cuanto se refiere a los env\u00edos de adjudicaciones, esta convocatoria de gran envergadura, cuenta con plazos limitados para la evaluaci\u00f3n, cierre y posterior firmas de contratos, se ha tenido suficiente tiempo para las consultas respectivas, las mismas han sido adendadas en su gran mayor\u00eda por la Instituci\u00f3n.", "dateAnswered": "2024-09-26T14:25:37-04:00"}, {"id": "f396471ed0cb5cb3477a7d1fc91a90cd-1", "date": "2024-09-25T16:58:04-04:00", "title": "Entrega de Bienes", "description": "PLAN DE ENTREGA DE BIENES\nEl 100% de los bienes se entregar\u00e1 dentro de los 30 d\u00edas a partir de la firma del contrato.\nSin embargo, solicitamos a la convocante que se considere una extensi\u00f3n del plazo de entrega de los equipos a 60 d\u00edas. Esto se debe a que, considerando la etapa de la convocatoria y la alta demanda de transporte que se presenta fin de a\u00f1o, los 30 d\u00edas no son suficientes para garantizar una entrega oportuna de este tipo de equipos.", "answer": "Ajustarse a lo solicitado en el PBC, atendiendo a los plazos, establecidos en la Resoluci\u00f3n DNCP N\u00b0 1430/2024 \"Plazos m\u00e1ximos para comunicar a la DNCP los llamados, adjudicaciones y contratos que afecten a los procesos que comprometan el PGN 2024\", en cuanto se refiere a los env\u00edos de adjudicaciones, esta convocatoria de gran envergadura, cuenta con plazos limitados para la evaluaci\u00f3n, cierre y posterior firmas de contratos, se ha tenido suficiente tiempo para las consultas respectivas, las mismas han sido adendadas en su gran mayor\u00eda por la Instituci\u00f3n.", "dateAnswered": "2024-09-26T14:24:42-04:00"}, {"id": "17f9605cc40843ef2fecd39fd0f5b973-1", "date": "2024-09-18T19:18:13-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 34. Punto 6.1.8", "description": "\u201cMagnificaci\u00f3n de im\u00e1genes (Zoom) hasta 50x en tiempo real. \u201cSolicitamos a la convocante que considere ajustar el requisito de \"Magnificaci\u00f3n de im\u00e1genes (Zoom) hasta 50x en tiempo real\" a un rango de magnificaci\u00f3n de 20x \u00b110. La especificaci\u00f3n actual de 50x puede ser excesiva para la mayor\u00eda de las aplicaciones cl\u00ednicas y puede limitar innecesariamente la participaci\u00f3n de proveedores. Un rango de magnificaci\u00f3n de 20x \u00b110 sigue proporcionando un nivel adecuado de detalle para la mayor\u00eda de las evaluaciones cl\u00ednicas, al tiempo que se alinea mejor con los costos y la funcionalidad de equipos de gama alta. Esta modificaci\u00f3n permitir\u00e1 una mayor flexibilidad en la selecci\u00f3n de equipos y fomentar\u00e1 una competencia m\u00e1s equitativa.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:17:00-04:00"}, {"id": "cc2f194431373499dcb52f85b7c8f4eb-1", "date": "2024-09-18T11:13:22-04:00", "title": "ITEM 19 - Caja de curaci\u00f3n", "description": "ITEM 19 - Caja de curaci\u00f3n\nEn una parte de las especificaciones t\u00e9cnicas dice: Todos los instrumentales son de material de acero Inoxidable quir\u00fargico, demostrado por Certificados de calidad de la CE e ISO 13485.", "answer": "La consulta no se identifica.", "dateAnswered": "2024-09-26T07:18:08-04:00"}, {"id": "42b76b25c17d360dd34b6a300821069e-1", "date": "2024-09-18T19:14:59-04:00", "title": "item 20 Cama electrica", "description": "En el Item 20 Cama el\u00e9ctric a para paciente: En el punto 4.5 Capacidad de ampliar el largo total del lecho de forma manual 25 cm +/- 5 cm, solicitamos a la convocante que este punto pueda ser opcional, de esta manera se dar\u00e1 mayor participaci\u00f3n a oferentes aclarando que las medidas solicitadas en el punto 4.3 ya son bastante largas de las medidas est\u00e1ndar solicitadas.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:16:36-04:00"}, {"id": "40310c977586e4279f22a57ba224a32a-1", "date": "2024-09-18T14:18:38-04:00", "title": "\u00cdtem 24 Cardiodesfibrilador", "description": "1.2 Con SpO2, CO2 y carro de paro para unidad de cuidados cr\u00edticos.\n\u00bfPodr\u00edan aclarar si se debe entregar un carro de paro por cada desfibrilador? Creemos que nn el \u00edtem 26 se solicitan los carros de paro para uso con estos equipos.", "answer": "Se aclara que se debe entregar un carro por cada equipo.", "dateAnswered": "2024-09-26T07:19:51-04:00"}, {"id": "2c006c238c93552fdf2906c6ff204e43-1", "date": "2024-09-14T11:05:45-04:00", "title": "Especificaciones T\u00e9cnicas - \u00cdtem 42) Ventilador Pulmonar de Alta Complejidad", "description": "DONDE DICE:\n\n3.1Normas de calidad espec\u00edficas: FDA, CE o JIS al menos alguna de ellas.\n\nFavor modificar a: \n\n3.1 FDA, CE JIS, o MERCOSUR al menos alguna de ellas.\n\nLo solicitado es debido a que el Paraguay es un miembro activo y fundador del MERCOSUR, lo cual debe permitir la inclusi\u00f3n de equipos con normas MERCOSUR para su comercializaci\u00f3n entre los miembros.", "answer": "Remitirse a la Adenda en el SICP.", "dateAnswered": "2024-09-26T07:14:31-04:00"}, {"id": "7c6980c7985f5d637679bcab2c86a2cd-1", "date": "2024-09-25T18:26:10-04:00", "title": "\u00cdtem 53", "description": "Donde dice \"5.6.3 - Medici\u00f3n de variaci\u00f3n de presi\u00f3n sist\u00f3lica (VPS), variaci\u00f3n de presi\u00f3n de pulso (VPP), presi\u00f3n de perfusi\u00f3n cerebral (PPC), medici\u00f3n de la presi\u00f3n venosa central al final de la expiraci\u00f3n (PVC - ET)\", solicitamos a la convocante que estas funciones sean consideradas como OPCIONALES, ya que la inclusi\u00f3n de todas estas mediciones podr\u00eda limitar la cantidad de oferentes que cumplan con estas especificaciones.", "answer": "Respondido en la Consulta 156.", "dateAnswered": "2024-09-26T14:25:27-04:00"}, {"id": "1cfb6240e7d24a2aaa6a6d34df55dc5a-1", "date": "2024-09-18T17:41:14-04:00", "title": "\u00cdtem 16 \u2013 Monitor Multiparam\u00e9trico", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 3.13 se solicita \u201cCapacidad de contar con Gasto Cardiaco por software\u201d, solicitamos a la convocante modificar este punto por \u201cM\u00f3dulo para la medici\u00f3n de Gasto Cardiaco\u201d, de manera a contar con todos los par\u00e1metros y funciones para la correcta medici\u00f3n del Gasto Cardiaco, teniendo en cuenta que lo solicitado es un equipo de Alta Complejidad. Tambien solicitamos a la Convocante pueda pedir los accesorios correspondientes para la medici\u00f3n de este par\u00e1metro.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:33:21-04:00"}, {"id": "575c7a2880e860d28705ecfabbefc8e3-1", "date": "2024-09-18T16:23:28-04:00", "title": "EETT- ITEM 34. Punto 4.6", "description": "Posibilidad de visualizar im\u00e1genes almacenadas en el equipo a trav\u00e9s de la pantalla t\u00e1ctil para realizar comparaciones con la imagen en la pantalla principal y seguimiento de estudios\" Solicitamos reconsiderar el requerimiento de visualizar im\u00e1genes almacenadas en el equipo a trav\u00e9s de la pantalla t\u00e1ctil para realizar comparaciones. Consideramos que esta funcionalidad es una opci\u00f3n m\u00e1s que una necesidad, ya que la comparaci\u00f3n de estudios en la pantalla principal es igualmente eficaz y garantiza una visualizaci\u00f3n m\u00e1s amplia y clara de las im\u00e1genes, lo cual es crucial para la precisi\u00f3n diagn\u00f3stica. Proponemos que esta funcionalidad sea opcional y que la comparaci\u00f3n en la pantalla principal sea aceptable para no limitar la participaci\u00f3n de equipos que cumplen con altos est\u00e1ndares de calidad pero no cuentan con esta caracter\u00edstica\u00a0espec\u00edfica.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:27:48-04:00"}, {"id": "aea04d5d70d3284f7485f58fc9c197df-1", "date": "2024-09-18T18:52:14-04:00", "title": "Item 36 \u2013 Electrocardiografo", "description": "En el punto 36 5.12 Funciones de prueba, como m\u00ednimo: Prueba ECG en reposo (12, 15\nderivaciones), prueba intervalo RR. Solicitamos que las 15 derivaciones sean opcionales considerando el precio referencial.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:14:34-04:00"}, {"id": "c5483d3363a9f6446ddc836d35dc123b-1", "date": "2024-09-12T12:57:57-04:00", "title": "Plan de entrega de los bienes", "description": "Establece el PBC en el Plan de entrega de los bienes: El 100 % dentro de los 30 d\u00edas a partir de la firma del contrato.\nFavor considerar ampliar el tiempo de entrega en 90 d\u00edas, muchos de los equipos requieren importaci\u00f3n a\u00e9rea y otros mar\u00edtima debido a los gases que contienen y 30 d\u00edas es solo para equipos que hay en plaza, esto limita la posibilidad de que el ente pueda seleccionar los mejores equipos al mejor precio.", "answer": "Ajustarse al PBC, atendiendo a que dicha convocatoria no es una licitaci\u00f3n plurianual y ya no se contar\u00eda con tiempo necesario para el ejercicio 2024.", "dateAnswered": "2024-09-26T07:09:05-04:00"}, {"id": "5c65cd971c9281104518db9130fc58df-1", "date": "2024-09-18T21:12:15-04:00", "title": "\u00cdtem 42: Ventilador pulmonar de alta complejidad.", "description": "El PBC solicita Tiempo espiratorio 0,1 a 103 seg \u00b1 5 seg. Se sugiere amablemente a la convocante permitir cotizar equipo con especificaciones de Tiempo espiratorio en rangos de 0.05 a 60 Seg, acerc\u00e1ndose m\u00e1s a tiempos reales en la mec\u00e1nica ventilatoria y con ello se permitir\u00e1 la competencia de potenciales oferentes con equipo de calidad y funcionalidad comprobada en el mercado local, por lo que planteamos la siguiente reformulacion del requisito: Tiempo espiratorio (seg):  0,1 o menor a 60 seg o mayor.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:27:21-04:00"}, {"id": "6ed93682a431b803f21d0969e0deed4a-1", "date": "2024-09-18T09:52:28-04:00", "title": "Consulta 1: Laringoscopio Adulto \u2013 Item N\u00b0 43", "description": "Podr\u00eda la convocante aclarar las medidas de las hojas solicitas ya que solo hace menci\u00f3n a \u201cHojas curvas Mcintosh N\u00ba 3, 4, 5\u201d sin especificar las dimensiones del mismo.", "answer": "Las medidas solicitadas corresponden a medidas estandares enumeradas.", "dateAnswered": "2024-09-26T07:17:47-04:00"}, {"id": "8ae74be41a169278404123effed96c7c-1", "date": "2024-09-18T10:18:01-04:00", "title": "/*Requisitos documentales para evaluar el criterio de capacidad t\u00e9cnica", "description": "En los Requisitos documentales para evaluar el criterio de capacidad t\u00e9cnica solicitan \"Documentos que acrediten que el Oferente es fabricante del producto que oferta. Trat\u00e1ndose de Agente, Distribuidor o Representante para el Paraguay, deber\u00e1 presentar la documentaci\u00f3n expedida por el fabricante o Agente Regional, debidamente inscripta en el Registro P\u00fablico de Comercio, Secci\u00f3n Representaciones, con certificado de vigencia del fabricante\" Solicitamos a la convocante excluir la Inscripci\u00f3n de la documentaci\u00f3n en el Registro publico de comercio, ya que dicho requerimiento estar\u00eda limitando la participaci\u00f3n de potenciales oferentes, en su lugar sugerimos solicitar la Autorizaci\u00f3n del Fabricante.", "answer": "Ajustarse al PBC.", "dateAnswered": "2024-09-26T07:17:50-04:00"}, {"id": "0fdfdd14f0f6823f4c15efe37798240d-1", "date": "2024-09-17T17:34:02-04:00", "title": "ITEM 34", "description": "En el \u00edtem 34 de las Especificaciones t\u00e9cnicas donde dice \u201cPantalla secundaria t\u00e1ctil de 15 \u00b12\" para el manejo interactivo del men\u00fa, para acceso a modos de operaci\u00f3n aplicaciones y configuraciones\u201d. Solicitamos a la convocante la modificaci\u00f3n de este Item por \u201cPantalla secundaria t\u00e1ctil de 12 \u00b12\" para el manejo interactivo del men\u00fa, para acceso a modos de operaci\u00f3n aplicaciones y configuraciones\u201d, esta modificaci\u00f3n ampliar\u00e1 la participaci\u00f3n de oferentes y no afectar\u00e1 la funcionalidad del equipo, la disminuci\u00f3n del tama\u00f1o de la pantalla secundaria conservar\u00e1 la eficiencia del equipo sin afectar sus caracter\u00edsticas clave.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:16:01-04:00"}, {"id": "4a471c611effd8f2b1f8595207b47689-1", "date": "2024-09-18T22:10:15-04:00", "title": "ITEM 44 \u2013 MAQUINA DE ANESTESIA", "description": "En el punto 5.15 donde dice \u201cSensiblidad de disparo o trigger por flujo. rango de 0,2 LPM a 10 LPM\u201d solicitamos amablemente a la convocante permita cotizar equipos con Sensiblidad de disparo o trigger por flujo. rango de 0,5 LPM o menor a 10 LPM o mayor. Dando asi apertura a las especificaciones t\u00e9cnicas para la participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:19-04:00"}, {"id": "88233a8efaecc83f0ef892407885c6bc-1", "date": "2024-09-18T18:52:47-04:00", "title": "Item 53 \u2013 Monitor multiparam\u00e9trico", "description": "53 4.1 Monitor modular. de baja complejidad, en este punto se menciona que el monitor debe ser de baja complejidad, sin embargo las especificaciones t\u00e9cnicas solicitadas m\u00e1s adelante son de un monitor de alta complejidad, solicitamos por favor revisen las especificaciones t\u00e9cnicas de manera a que podamos cotizar un monitor acorde a las necesidades del servicio donde ser\u00e1n instalados.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:15:33-04:00"}, {"id": "5c2f9fa56cae14f5ef6a9f7329ef69d5-1", "date": "2024-09-18T21:19:01-04:00", "title": "\u00cdtem 42: Ventilador pulmonar de alta complejidad.", "description": "El PBC solicita Cable interface de CO2 de la misma marca que el ventilador. Se solicita amablemente a la convocante permitir cotizar equipo, sin ir en detrimento de lo solicitado, con la provisi\u00f3n de cables y sensores de CO2 aptos y validados para la tecnolog\u00eda de nuestros equipos y as\u00ed permitir la competencia de marcas con experiencia comprobada en el mercado local, sean aceptados equipos con Cable interface de CO2 con tecnolog\u00eda validada para el ventilador, a fin de brindar mayor oportunidad de participacion de los oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:27:31-04:00"}, {"id": "a585b6b9115ca2b3b1f41a73b0664abd-1", "date": "2024-09-18T16:09:23-04:00", "title": "Certificaci\u00f3n de la calidad de los instrum\u00e9ntales", "description": "En los lotes de instrumentales solicitan Certificaci\u00f3n de la calidad de los instrum\u00e9ntales: DIM EN 10088T.1-3, EN ISO 7153-1 , y EN ISO 13485:2016 \nSolicitamos a la convocante presentar solo unas de las certificaciones solicitadas o correspondiente a ellas.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:27:45-04:00"}, {"id": "ef227ff4280f21ac5c38f054a73dfdca-1", "date": "2024-09-18T19:15:02-04:00", "title": "item 20 Cama electrica", "description": "En el Item 20 Cama el\u00e9ctrica a para paciente: En el punto 4.11 solicitan 2 (dos) controles el\u00e9ctricos desmontables de la cama. Uno para control del paciente y el otro control para el personal m\u00e9dico del hospital, como m\u00ednimo. Ambos desmontables con cable. Solicitamos a la convocante se pueda considerar los controles en las barandas laterales tanto para el paciente por dentro como para los profesionales por fuera", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:16:38-04:00"}, {"id": "7c9269bcb17ada628bd0658bf3148d1c-1", "date": "2024-09-18T11:13:00-04:00", "title": "ITEM 8 Caja de Cirugia Menor", "description": "ITEM 8 Caja de Cirugia Menor -\nEn una parte de las especificaciones t\u00e9cnicas dice: Todos los instrumentales son de material de acero Inoxidable quir\u00fargico, demostrado por Certificados de calidad de la CE e ISO 13485.\nSolicitamos al convocante permita cotizar certificado de calidad de la CE e ISO 13485 (al menos una de ellas).", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:18:04-04:00"}, {"id": "52776e01f32768b046acac958255f950-1", "date": "2024-09-18T22:28:28-04:00", "title": "ID 443857 - \u00cdtem 34 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Rango Din\u00e1mico de al menos 350dB\" solicitamos a la convocante modificar este punto a \"Rango Din\u00e1mico de al menos 260dB\" lo solicitado obedece a que esta caracter\u00edstica no afecta al estudio ni a la calidad de imagen, por lo que limita innecesariamente una mayor participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:33:50-04:00"}, {"id": "a644ab77dc0d9bcc482d87b5f98a9017-1", "date": "2024-09-18T20:48:45-04:00", "title": "\u00cdtem 37: Equipo para tratamiento de hemodi\u00e1lisis", "description": "El PBC solicita Funci\u00f3n de historial de mensajes de al menos 800 eventos. Funci\u00f3n de registro de cambios en el sistema. Se solicita amablemente a la convocante que, de manera a permitir la competencia de marcas de gran reconocimiento a nivel mundial y experiencia comprobada en el mercado local, por lo que planteamos la siguiente reformulacion del requisito: Funci\u00f3n de historial de mensajes de al menos 800 eventos. Funci\u00f3n de registro de cambios en el sistema (opcional), a fin de brindar mayor oportunidad de participacion a los oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:19:50-04:00"}, {"id": "cfbac48a9cd3f0b8b7d98f1c763402e0-1", "date": "2024-09-18T19:15:19-04:00", "title": "item 20 Cama electrica", "description": "En el Item 20 Cama el\u00e9ctrica a para paciente: En el punto 7.1 Solicitan Colch\u00f3n de espuma de poliuretano de la misma marca de la cama, el oferente deber\u00e1 presentar un certificado que los colchones son de la misma marca de la cama ofertada y un Certificado de la Norma de calidad CE MDD93/42/EEC Class 1, Dicha norma no aplica para los que se fabrican a nivel de mercosur ni otros pa\u00edses que no cuentan con certificaciones CE, por lo tanto solicitamos que este punto sea opcional y de esta manera se dar\u00e1 mayor participaci\u00f3n con los que tenga normas del MERCOSUR y FDA.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:16:51-04:00"}, {"id": "f815cb28f058e703ec625e0e80a63d2f-1", "date": "2024-09-17T15:20:11-04:00", "title": "ITEM 34", "description": "7.3 donde dice\nTransductor lineal con ancho de banda de 4 MHz o menor a 15 MHz o mayor. Compatible para uso de elastosonograf\u00eda. Cantidad: 01 (uno) por cada equipo\nSolicitamos disminuir la frecuencia de 4 MHz a 14 MHz para mayor participaci\u00f3n de oferentes", "answer": "Remitirse a la Adenda en el SICP.", "dateAnswered": "2024-09-26T07:14:58-04:00"}, {"id": "972fd77f5c074f93035b7ebed951c00c-1", "date": "2024-09-18T18:51:34-04:00", "title": "Item 24 \u2013 Cardiodesfibrilador", "description": "Con respecto a la capnograf\u00eda solicitada, se aceptar\u00e1n desfibriladores del tipo sidestream y no mainstream", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:14:14-04:00"}, {"id": "4d23ee05144bec61e440c71fb38e7498-1", "date": "2024-09-18T19:30:55-04:00", "title": "ITEM 38 \u2013 Equipo de rayos x portatil", "description": "En el punto 3.9 donde dice \u201cRotaci\u00f3n transversal del tubo \u00b190 grados \u00b1 2\u00b0\u201d solicitamos amablemente a la convocante permita la cotizacion de equipos con rotaci\u00f3n transversal de 180\u00b0, y asi dar participaci\u00f3n de potenciales oferentes, considerando que este pedido no afecta en las prestaciones finales del equipo.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:17:59-04:00"}, {"id": "f67e88f311c7c278239eed3e1196c7bb-1", "date": "2024-09-25T17:28:43-04:00", "title": "ESPECIFICACIONES TECNICAS - ITEM 21. 4.4.1", "description": "Donde se solicita \"Longitud m\u00ednima 190 cm \u00b1 5 cm\", solicitamos a la convocante considerar ajustar la especificaci\u00f3n de longitud m\u00ednima de la cama a 195 cm \u00b1 5 cm. Esta medida sigue siendo adecuada para la mayor\u00eda de los entornos cl\u00ednicos y permite una mayor flexibilidad en la oferta de equipos, sin comprometer la comodidad o funcionalidad necesaria para los cuidados cr\u00edticos.", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:24:54-04:00"}, {"id": "d383651efc8921a1015dfdd598e999ff-1", "date": "2024-09-18T17:42:27-04:00", "title": "\u00cdtem 16 \u2013 Monitor Multiparam\u00e9trico", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 6.4 se solicita \u201cFrecuencia de muestreo 100 Hz por canal Rango +- 400 uV\u201d solicitamos a la Convocante pueda modificar este punto por \u201cFrecuencia de muestreo 100 Hz o mayor\u201d de manera a poder ajustarse a las tecnolog\u00edas disponibles en el mercado y posibilitando la participaci\u00f3n de m\u00e1s oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:33:28-04:00"}, {"id": "af6b49c83bc3fd5a9a5c9a8bc6d11ca8-1", "date": "2024-09-18T14:19:23-04:00", "title": "\u00cdtem 25 Cardiodesfibrilador", "description": "11.2 Para papel de 50 mm.\n\u00bfSe podr\u00eda considerar de 50 a 58mm?", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:21:44-04:00"}, {"id": "81d481bfe70eb52693208dc01d03434b-1", "date": "2024-09-17T17:27:34-04:00", "title": "Plan de entrega de los bienes", "description": "En el Plan de Entrega de los bienes, el PBC establece que el 100% de los equipos debe ser entregado dentro de los 30 d\u00edas a partir de la firma del contrato. Solicitamos considerar una ampliaci\u00f3n del plazo de entrega a 90 d\u00edas. Este ajuste es necesario debido a que muchos de los equipos requieren importaci\u00f3n a\u00e9rea y mar\u00edtima, y el plazo actual de 30 d\u00edas es adecuado solo para equipos disponibles en stock local. Ampliar el tiempo de entrega permitir\u00e1 una mayor flexibilidad en la selecci\u00f3n de los equipos, facilitando la adquisici\u00f3n de opciones de mejor calidad y precio", "answer": "Remitirse a la respuesta de la consulta 1.", "dateAnswered": "2024-09-26T07:15:20-04:00"}, {"id": "2a78beee223342bc4bc482bfe9068811-1", "date": "2024-09-18T19:40:39-04:00", "title": "\u00edtem 42 ventilador pulmonar", "description": "En el punto 4.6 donde dice \u201cCPAP (cmH2O). De 0 a 50 \u00b1 5\u201d solicitamos a la convocante permita cotizar equipos con rango de CPAP de 4 a 30 o mejor, y asi dar participaci\u00f3n a potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:18:19-04:00"}, {"id": "4dcbe490b47dcb30f8d475988bbf3802-1", "date": "2024-09-18T18:51:07-04:00", "title": "Item 16 \u2013 Monitor multiparam\u00e9trico", "description": "En  el punto 16 2.2  Normas de calidad generales: ISO 13485. Dicho documento debe estar vigente e indicar marca y modelo ofertado, se\u00f1alamos que al tratarse de un certificado de f\u00e1brica y no de producto en particular por lo general no se mencionan los modelos, por lo que deber\u00edan solicitar marca y tipo de equipo ofertado", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:13:48-04:00"}, {"id": "a6bccb5ad9ddf9f094022f86a5e9d224-1", "date": "2024-09-17T18:02:18-04:00", "title": "CONSULTA 3. ITEM 20 \u2013 CAMA EL\u00c9CTRICA PARA PACIENTE.", "description": "En el punto: \u201c5.2 Elevaci\u00f3n el\u00e9ctrica de la secci\u00f3n de espalda. Rango de 0\u00b0 a 80\u00b0 +/- 5\u00b0\u201d. Se solicita a la convocante poder ampliar m\u00e1s este punto para permitir mayor participaci\u00f3n ya que lo normal en el uso para pacientes es de 60\u00b0. Al colocar en la graduaci\u00f3n m\u00e1xima de 80\u00b0 el paciente tiende a ir hacia el frente en la posici\u00f3n sentada ya que el colch\u00f3n (debido al espesor) tiende a ir hacia el frente y podr\u00eda provocar accidentes. Se solicita amablemente a la convocante permitir el cambio de este punto a: Rango de 0\u00b0 a 75\u00b0 +/- 10\u00b0.", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:17:23-04:00"}, {"id": "702317e125607b38e2e23ff7699bfe58-1", "date": "2024-09-25T22:12:39-04:00", "title": "EETT ITEM 23. 2.4", "description": "En relaci\u00f3n con la especificaci\u00f3n de \"Capacidad de carga segura de 250 kg \u00b1 50 kg\", solicitamos a la convocante considerar ajustar las especificaciones a 300 kg \u00b1 50 kg. Este ajuste proporcionar\u00eda una mayor capacidad de carga, permitiendo mayor seguridad y versatilidad para el uso del equipo en una amplia variedad de pacientes, sin comprometer la funcionalidad o el rendimiento del equipo en entornos cl\u00ednicos\u00a0cr\u00edticos.", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:25:48-04:00"}, {"id": "1ee9a0b65ba869abfc97141dcbaa200f-1", "date": "2024-09-18T17:40:28-04:00", "title": "\u00cdtem 53 \u2013 Monitor Multiparam\u00e9trico", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 4.1 solicitan Monitor modular de baja complejidad, esto va acorde al precio unitario estimado fijado para este \u00edtem, sin embargo, vemos que las especificaciones no se adecuan a un Monitor de baja complejidad, de hecho, las especificaciones son id\u00e9nticas a las del \u00edtem 16 donde se solicitan Monitores de Alta complejidad. Instamos a la Convocante a modificar las especificaciones del \u00edtem 53 para que se ajuste a un equipo de Baja Complejidad por consiguiente al precio unitario estipulado.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:28:06-04:00"}, {"id": "d95b43538208d49ab181d42801cdafb9-1", "date": "2024-09-14T11:05:10-04:00", "title": "Especificaciones T\u00e9cnicas  - \u00cdtem 53) Monitor Multiparam\u00e9trico", "description": "8.4 Un cable troncal, tres cables de paciente para ECG de tres puntas y tres cables de pacientes para ECG de 5 o 6 puntas.\n\nSolicitamos eliminar o modificar el requerimiento que solicita un cable troncal con tres cables de paciente para ECG de tres puntas y tres cables de paciente para ECG de 5 o 6 puntas, dado que los monitores equipados con la actualizaci\u00f3n de 12 derivaciones de ECG no son compatibles con cables de 3 o 5 puntas. Para evitar incompatibilidades y garantizar un funcionamiento \u00f3ptimo del equipo, es necesario ajustar este requerimiento a la tecnolog\u00eda disponible o eliminarlo si no es relevante para el equipo solicitado.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:14:25-04:00"}, {"id": "2c0ba502f99bf5024ce52335bcf29ad4-1", "date": "2024-09-18T17:51:26-04:00", "title": "\u00cdTEM 33 ECOCARDI\u00d3GRAFO", "description": "Se solicita a la convocante admitir  Peso desde 1020\u00b120mm, para dar mayor participaci\u00f3n a oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:10:43-04:00"}, {"id": "7ab0a5c78cca6c8b89b158b35fcc0518-1", "date": "2024-09-14T11:03:58-04:00", "title": "Especificaciones T\u00e9cnicas  - \u00cdtem 16) Monitor Multiparam\u00e9trico", "description": "7.4 Un cable troncal, tres cables de pacientes para ECG de tres puntas y tres cables de paciente para ECG de 5 o 6 puntas.\n\nSolicitamos eliminar o modificar el requerimiento que solicita un cable troncal con tres cables de paciente para ECG de tres puntas y tres cables de paciente para ECG de 5 o 6 puntas, dado que los monitores equipados con la actualizaci\u00f3n de 12 derivaciones de ECG no son compatibles con cables de 3 o 5 puntas. Para evitar incompatibilidades y garantizar un funcionamiento \u00f3ptimo del equipo, es necesario ajustar este requerimiento a la tecnolog\u00eda disponible o eliminarlo si no es relevante para el equipo solicitado.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:14:13-04:00"}, {"id": "017cb8d02f969cf3f33ed7d8632fc420-1", "date": "2024-09-18T17:40:39-04:00", "title": "\u00cdtem 53 \u2013 Monitor Multiparam\u00e9trico", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 4.14 se solicita \u201cCapacidad de contar con Gasto Cardiaco por software\u201d, solicitamos a la convocante modificar este punto por OPCIONAL, ya que esta funci\u00f3n por software limitar\u00eda la participaci\u00f3n de oferentes. Teniendo en cuenta que el equipo solicitado es un equipo de baja complejidad no se justifica la medici\u00f3n de Gasto Cardiaco.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:28:11-04:00"}, {"id": "748946fa6b1cc4bafc01f36a8da320ea-1", "date": "2024-09-18T18:51:22-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 33. 2.19", "description": "\u201cFrame Rate de 6600Hz o mayor\u201d Solicitamos a la convocante reconsiderar la especificaci\u00f3n que menciona un Frame Rate de 6600 Hz o mayor. Es importante aclarar que el Frame Rate se mide en fps (fotogramas por segundo), no en Hz. Adem\u00e1s, este valor de 6600 fps est\u00e1 destinado a equipos de muy alta gama, lo que eleva considerablemente el costo, limitando la participaci\u00f3n de m\u00e1s oferentes. Sugerimos que se permita un rango a partir de 1000 fps, que sigue siendo adecuado para garantizar un rendimiento \u00f3ptimo en la mayor\u00eda de aplicaciones, sin encarecer innecesariamente el equipo.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:14:03-04:00"}, {"id": "ede595dbe03355da65519069798ba112-1", "date": "2024-09-18T14:40:53-04:00", "title": "/*Requisitos documentales para evaluar el criterio de capacidad t\u00e9cnica", "description": "12. Declaraci\u00f3n jurada de que la empresa adjudicada se compromete Incluir mantenimientos preventivos y asistencia t\u00e9cnica a demanda por un a\u00f1o.\nSolicitamos a la convocante excluir que los mantenimientos sean \"a demanda\" ya que es imposible determinar cuantos mantenimientos ser\u00e1n requeridos por la convocante. Los equipos requeridos ya cuentan con garant\u00eda establecida y los mismos ser\u00e1n nuevos y no remanufacturados por lo tanto no es necesario que el mantenimiento sea \"a demanda\" de la convocante. Sugerimos a la convocante solicitar que se realice capacitaci\u00f3n sobre el uso adecuado del equipo en el momento de la entrega o instalaci\u00f3n, mantenimiento preventivo a los 6 meses de entregado el equipo y antes de finalizar la garant\u00eda.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:23:41-04:00"}, {"id": "7cbbbe580b28faba6d74cc29e288916c-1", "date": "2024-09-18T16:09:08-04:00", "title": "Experiencia requerida", "description": "Donde doce:  Demostrar experiencia Venta y distribuci\u00f3n en el ramo de equipos m\u00e9dicos, con facturaciones de venta y/o recepciones finales por un  monto equivalente al [30] % como m\u00ednimo del monto total ofertado en la presente licitaci\u00f3n, de los \u00faltimos [3] a\u00f1os (2021, 2022, 2023)  El porcentaje requerido ser\u00e1 considerado en sumatoria de los a\u00f1os indicados . \nConsulta: Llevando en cuenta que tambi\u00e9n se esta solicitando  instrumentales, sugerimos a la convocante agregar en experiencia tambi\u00e9n instrumentales a parte de equipos.", "answer": "Remitirse a la respuesta de la consulta 25.", "dateAnswered": "2024-09-26T07:26:35-04:00"}, {"id": "28c989db5f9846d76f32ee2bb460af16-1", "date": "2024-09-18T19:14:58-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 34. 4.5", "description": "\u201cPantalla secundaria t\u00e1ctil de 15 \u00b12\" para el manejo interactivo del men\u00fa, para acceso a modos de operaci\u00f3n aplicaciones y configuraciones.\u201d Solicitamos a la convocante que considere ajustar el requisito para la \"Pantalla secundaria t\u00e1ctil\" a un rango de 10 \u00b13 pulgadas en lugar de 15 \u00b12 pulgadas. Las pantallas t\u00e1ctiles de 10 pulgadas proporcionan un equilibrio \u00f3ptimo entre visibilidad y ergonom\u00eda, permitiendo un manejo interactivo eficiente del men\u00fa sin ocupar un espacio excesivo en el equipo. Esto facilita una operaci\u00f3n m\u00e1s intuitiva y accesible para los usuarios, especialmente en entornos cl\u00ednicos donde el espacio en el \u00e1rea de trabajo puede ser limitado. Adem\u00e1s, un tama\u00f1o m\u00e1s compacto puede contribuir a un dise\u00f1o m\u00e1s compacto y port\u00e1til del equipo, sin comprometer la funcionalidad y la comodidad del usuario.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:16:33-04:00"}, {"id": "99c288531e877583e5d88a1e8218d87a-1", "date": "2024-09-18T14:32:52-04:00", "title": "\u00cdTEM 33 ECOCARDI\u00d3GRAFO", "description": "Se solicita a la convocante admitir  transductor sectorial transesof\u00e1gico multiplanar  con frecuencia de 2.3 a 7,2 MHz, para dar mayor participaci\u00f3n a oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:23:09-04:00"}, {"id": "91960283d842299f011b5d6b5bcdafe4-1", "date": "2024-09-13T12:15:34-04:00", "title": "\u00cdtem 51  Microscopios de fluorescencia", "description": "En el punto 5.3 Cubo de excitaci\u00f3n B  de un solo color. Favor indicar cual fluorocromo van a utilizar? Similar a FITC?", "answer": "Se aclara que todos los anticuerpos son FITC.", "dateAnswered": "2024-09-26T07:09:24-04:00"}, {"id": "f6908381f4fdc8d29225c96f96b20c4d-1", "date": "2024-09-23T14:57:31-04:00", "title": "CAPACITACION", "description": "ITEM 38 En el punto 8.4 Capacitaci\u00f3n a usuarios sobre el funcionamiento del equipo y capacitaci\u00f3n t\u00e9cnica al personal t\u00e9cnico del Departamento de Electromedicina. \nSe solicita amablemente a la convocante especificar la cantidad de horas necesarias para realizar el entrenamiento. Sin embargo, se sugiere que para cumplir con dicho punto es m\u00e1s que suficiente 8 horas por 1 d\u00eda y de esta manera cubrir con todos los puntos que pueden realizar los usuarios", "answer": "Respondido en la Consulta 406.", "dateAnswered": "2024-09-26T14:24:00-04:00"}, {"id": "036ab55d20eb8bf88f21ddbc6863c127-1", "date": "2024-09-18T14:18:48-04:00", "title": "\u00cdtem 24 Cardiodesfibrilador", "description": "4.5 Conectividad Bluetooth para transmisi\u00f3n de datos de descarga a trav\u00e9s de software para PC.\n\u00bfSe podr\u00eda considerar conectividad Bluetooth o USB?", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:19:56-04:00"}, {"id": "2db372653b909c9f128764205ac63a7a-1", "date": "2024-09-25T18:26:01-04:00", "title": "\u00cdtem 53", "description": "Donde dice \"7.1 - Con al menos 8 canales de EEG\", solicitamos a la convocante permitir un rango de 4 canales a 8 o m\u00e1s canales, para ampliar la participaci\u00f3n de m\u00e1s oferentes que puedan cumplir con los requisitos t\u00e9cnicos.", "answer": "Respondido en la Consulta 249.", "dateAnswered": "2024-09-26T14:25:25-04:00"}, {"id": "e3461a94bbf537f4b8c5387e5744da48-1", "date": "2024-09-18T14:32:58-04:00", "title": "\u00cdTEM 34 EC\u00d3GRAFO", "description": "Se solicita a la convocante admitir transductor convexo con un ancho de banda de 1,2 a 6.0 MHz, para dar mayor participaci\u00f3n a oferentes.", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:23:12-04:00"}, {"id": "40234c0a696e975af804eaddcd8c3a66-1", "date": "2024-09-18T22:08:17-04:00", "title": "ITEM 44 \u2013 MAQUINA DE ANESTESIA", "description": "En el punto 5.7 donde dice \u201cRango de entrega de volumen corriente de 5 ml a 1500 ml\u201d solicitamos a la convocante permita cotizar equipos con Rango de entrega de volumen corriente de rango de 10 mL o menor a 1500 mL o mayor, y asi dar apertura a las especificaciones para la participaci\u00f3n de potenciales oferentes", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:16-04:00"}, {"id": "46c6403a2cf20e22341fe594d89e8aed-1", "date": "2024-09-18T15:24:47-04:00", "title": "ITEM N\u00b0 37 - EQUIPO DE HEMODIALISIS", "description": "En el punto 2.17.2: \"Desinfecci\u00f3n qu\u00edmica y t\u00e9rmica, programables, con hasta 10 etapas\", solicitamos la modificaci\u00f3n la parte con hasta  10 etapas, ya que lo importante es que el equipo cumpla con los est\u00e1ndares y normas de desinfecci\u00f3n, no la cantidad de etapas. Si el \nequipo puede lograr una desinfecci\u00f3n adecuada y segura en menos de 10 etapas, a\u00f1adir m\u00e1s ser\u00eda redundante.", "answer": "Se encuentra dentro del rango.", "dateAnswered": "2024-09-26T07:24:09-04:00"}, {"id": "4271ac20bf3a8e15463550e345dfdc18-1", "date": "2024-09-14T11:30:09-04:00", "title": "ESPECIFICACIONES T\u00c9CNICAS - GARANT\u00cdA  \u2013 \u00cdTEMS 1  - ITEM 14 \u2013 ITEM 19 -", "description": "OTROS REQUERIMIENTOS \u2013 GARANT\u00cdA\nFavor aclarar si los mantenimientos correctivos requeridos son por cualquier tipo de evento, incluso por uso inadecuado, y si incluye provisi\u00f3n de repuestos o solamente mano de obra.\nSe sugiere que los mantenimientos correctivos sean solo por defectos de f\u00e1brica o para mano de obra, porque si se requiere para cualquier tipo de evento, incluso por mala utilizaci\u00f3n descuido o sabotaje por parte de los usuarios, no es posible realizar un c\u00e1lculo correcto para la cotizaci\u00f3n, o el precio a ofertar se incrementar\u00e1 como m\u00ednimo al doble del valor, con el consecuente perjuicio econ\u00f3mico para la entidad y el estado por una incorrecta elaboraci\u00f3n de especificaciones.\nLo que debe hacer la convocante, es realiza un llamado posterior a la adjudicaci\u00f3n, espec\u00edfico para mantenimiento correctivos de los equipos adjudicados y por evento, de manera a adquirir las piezas por evento, cada vez que se requiera, siempre y cuando no corresponda a un defecto de f\u00e1brica dentro del periodo de garant\u00eda.\nLa actual redacci\u00f3n, compromete seriamente el principio de eficacia, econom\u00eda y eficiencia, adem\u00e1s de poner en riesgo la ejecuci\u00f3n contractual y el patrimonio de la entidad y del estado, por el mal uso de los recursos aportados por todos los contribuyentes, que puede configurarse como lesi\u00f3n de confianza posteriormente.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:14:51-04:00"}, {"id": "0313e8427f6e72f9354a28696add2067-1", "date": "2024-09-18T18:50:01-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 33 Punto 2.13", "description": "\u201cAl menos 15.000.000 de canales de procesamiento digital\u201d\nSolicitamos a la convocante reconsiderar la especificaci\u00f3n que requiere al menos 15.000.000 de canales de procesamiento, ya que esto incrementa significativamente el costo del equipo, lo cual no corresponde con el precio referencial propuesto. Adem\u00e1s, esta especificaci\u00f3n est\u00e1 limitada a equipos de gama muy alta, reduciendo la cantidad de oferentes. Solicitamos que se permita un rango a partir de 900.000 canales de procesamiento, lo cual sigue siendo adecuado para cumplir con los requisitos de rendimiento y funcionalidad.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:13:01-04:00"}, {"id": "f5fa8d6c1d4064ea72f746ae44dbb384-1", "date": "2024-09-18T17:52:16-04:00", "title": "\u00cdTEM 35 EC\u00d3GRAFO", "description": "4.11 Se solicita a la convocante admitir Frame Rate del sistema de al menos Velocidad de cuadro (m\u00e1x.): 610 f/s. para dar mayor participaci\u00f3n a oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:11:31-04:00"}, {"id": "ee54e77e9f0042ed77f94a1f23b2378b-1", "date": "2024-09-19T06:56:06-04:00", "title": "item 42", "description": "Pendiente de inyecci\u00f3n de flujo inspiratorio ajustable (%). De 5 a 100\nFavor aclarar si se refiere a la rampa en modo presi\u00f3n.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:58-04:00"}, {"id": "225a35f9cd192e72db090b8ac4e4a943-1", "date": "2024-09-18T18:52:52-04:00", "title": "Item 53 \u2013 Monitor multiparam\u00e9trico", "description": "Donde piden 53.5.6.2  Etiquetado del sitio de medici\u00f3n: P1, P2, P3, ART, ART2, RAD, DORS, AO, FEM, UA, UV, PAP, CVP, RAP, RVP, LAP, LVP, ICP, ICP2, ICP3, solicitamos se puedan cotizar monitores con las siguientes etiquetas: P1, P2, ART, RAD, AO, FEM, UA, UV, PAP, CVP, RAP, LAP, LVP, ICP, considerando que se contar\u00e1n con dos etiquetas libres y que las etiquetas espec\u00edficas solicitadas corresponden a la marca Nihon Kohden por lo que limita la libre participaci\u00f3n de otros oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:15:40-04:00"}, {"id": "8eb772ff65cc1d2453fbd96b54b14342-1", "date": "2024-09-18T20:48:24-04:00", "title": "\u00cdtem 37: Equipo para tratamiento de hemodi\u00e1lisis", "description": "El PBC solicita Perfiles de UF, Sodio y Bicarbonato, programables y personalizables. Se solicita amablemente a la convocante permitir cotizar equipos que cuenten con perfiles de Sodio y Ultrafiltraci\u00f3n como principales en el tratamiento, con posibilidad de ajuste de concentraci\u00f3n de bicarbonato para el tratamiento. De manera a permitir la competencia de marcas de gran reconocimiento a nivel mundial y experiencia comprobada en el mercado local, por lo que planteamos la siguiente reformulacion del requisito: Perfiles de UF, Sodio, programables y personalizables, perfil de bicarbonato (opcional), a fin de brindar mayor oportunidad de participaci\u00f3n a los oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:19:45-04:00"}, {"id": "516322391df84e1d5348c28adc2d3601-1", "date": "2024-09-17T17:43:14-04:00", "title": "ITEM 35", "description": "En el \u00edtem 35 de las Especificaciones t\u00e9cnicas donde dice \u201c Inicio r\u00e1pido del sistema inferior a 15 segundos\u201d , solicitamos a la convocante la modificaci\u00f3n de este \u00edtem por \u201cInicio r\u00e1pido del sistema alrededor de 60 segundos\u201d, Este ajuste se alinea con los est\u00e1ndares normales de los equipos disponibles en el mercado y permitir\u00e1 una mayor flexibilidad en las ofertas sin comprometer la funcionalidad esencial del sistema", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:16:30-04:00"}, {"id": "7c75e2e7c67d30251b4dc39dab04d24f-1", "date": "2024-09-18T22:32:32-04:00", "title": "ID 443857 - \u00cdtem 34 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Software para mejorar la visualizaci\u00f3n de las agujas durante la biopsia\" solicitamos a la convocante considerar este punto como OPCIONAL, debido a que esta caracter\u00edstica encarece significativamente el precio referencial del ec\u00f3grafo requerido.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:34:56-04:00"}, {"id": "f03ef4644b0cc661bfd68478db617905-1", "date": "2024-09-25T18:41:35-04:00", "title": "REQUISITOS DOCUMENTALES PARA EVALUAR EL CRITERIO DE CAPACIDAD T\u00c9CNICA", "description": "En el apartado de Requisitos documentales para evaluar el criterio de capacidad t\u00e9cnica, en el \u00edtem 12 se expresa: \u201cDeclaraci\u00f3n jurada de que la empresa adjudicada se compromete a: Incluir mantenimientos preventivos y asistencia t\u00e9cnica a demanda por un a\u00f1o. Que los mantenimientos se realizaran seg\u00fan los est\u00e1ndares de la marca y del equipo ofertado, presentar copia el protocolo de mantenimiento. Que proveer\u00e1 Asistencia t\u00e9cnica seg\u00fan necesidad, sea mantenimiento preventivo o correctivo, en un periodo menor a 48 hs., stock de repuestos y accesorios originales de f\u00e1brica\u201d se solicita amablemente a la convocante aclarar si el mantenimiento correctivo debe incluir la provisi\u00f3n de repuestos. En caso afirmativo, tambi\u00e9n pedimos que se especifique que los mantenimientos correctivos solo cubrir\u00e1n defectos de f\u00e1brica, excluyendo problemas ocasionados por un uso inadecuado por parte del operario o da\u00f1os por factores externos (como por ejemplo el sistema de alimentaci\u00f3n el\u00e9ctrica). Asimismo, solicitamos la exclusi\u00f3n del t\u00e9rmino \"a demanda\", ya que resulta dif\u00edcil predecir la cantidad exacta de mantenimientos necesarios. Los equipos solicitados contar\u00e1n con garant\u00eda y ser\u00e1n nuevos, por lo que consideramos innecesario que el mantenimiento sea \"a demanda\".", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:25:40-04:00"}, {"id": "0a69cda0d094fa012d9684eb3ac4c4de-1", "date": "2024-09-25T17:41:14-04:00", "title": "\u00cdtem 42", "description": "Donde dice: \"Respiraci\u00f3n r\u00e1pida superficial RSBI 0 a 9999 bpm/l.\"\nSolicitamos a la convocante considerar un rango m\u00ednimo de 0 a 999 bpm/l, lo cual permite una mayor cantidad de oferentes cumplir con esta especificaci\u00f3n, facilitando as\u00ed una participaci\u00f3n m\u00e1s amplia.", "answer": "Respondido en la Consulta 323.", "dateAnswered": "2024-09-26T14:25:08-04:00"}, {"id": "46133e256eee03d9a4041f50e986c74b-1", "date": "2024-09-18T22:31:14-04:00", "title": "ID 443857 - \u00cdtem 34 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Software para detecci\u00f3n autom\u00e1tica de translucencia intracraneal\" solicitamos a la convocante modificar este punto a \"Software para detecci\u00f3n autom\u00e1tica de translucencia intracraneal\" lo solicitado no afectar\u00e1 la funcionalidad solicitada para este punto, adem\u00e1s lo solicitado es el est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda, por lo que solicitamos modificar este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:34:51-04:00"}, {"id": "9a03d17b2b0c73ca7b035ccd1a5b4aa4-1", "date": "2024-09-18T14:18:55-04:00", "title": "\u00cdtem 25 Cardiodesfibrilador", "description": "4.5 Conectividad Bluetooth para transmisi\u00f3n de datos de descarga a trav\u00e9s de software para PC.\n\u00bfSe podr\u00eda considerar conectividad Bluetooth o USB?", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:19:59-04:00"}, {"id": "f985daea69dda38e88148d4af8b479f8-1", "date": "2024-09-25T17:53:13-04:00", "title": "Experiencia Requerida :", "description": "Demostrar experiencia venta y distribuci\u00f3n en el ramo de equipos m\u00e9dicos, con facturaciones de venta y/o recepciones finales por un monto equivalente al [30] % como m\u00ednimo del monto total ofertado en la presente licitaci\u00f3n, de los \u00faltimos [3] a\u00f1os (2021, 2022, 2023) el porcentaje requerido ser\u00e1 considerado en sumatoria de los a\u00f1os indicados.\nSolicitamos a la convocante que incluya la presentaci\u00f3n de contratos para demostrar experiencia de ser as\u00ed quedar\u00eda redactada de la siguiente manera.\nDemostrar experiencia venta y distribuci\u00f3n en el ramo de equipos m\u00e9dicos, con contratos, facturaciones de venta y/o recepciones finales por un monto equivalente al [30] % como m\u00ednimo del monto total ofertado en la presente licitaci\u00f3n, de los \u00faltimos [3] a\u00f1os (2021, 2022, 2023) el porcentaje requerido ser\u00e1 considerado en sumatoria de los a\u00f1os indicados.", "answer": "Ajustarse a lo solicitado en el Pliego de Bases y Condiciones.", "dateAnswered": "2024-09-26T14:25:13-04:00"}, {"id": "18b51d3cb748e87d03e81928ebfb2c85-1", "date": "2024-09-17T16:36:26-04:00", "title": "Experiencia Requerida", "description": "En la p\u00e1gina 18 del PBC dice Experiencia Requerida:\n Demostrar experiencia Venta y distribuci\u00f3n en el ramo de equipos m\u00e9dicos, con facturaciones de venta y/o recepciones finales por un monto equivalente al [30] % como m\u00ednimo del monto total ofertado en la presente licitaci\u00f3n, de los \u00faltimos [3] a\u00f1os (2021, 2022, 2023).\nSolicitamos a la convocante que para demostrar la experiencia incluya la presentaci\u00f3n de Contratos de ser as\u00ed quedar\u00eda redactada de la siguiente manera: \nDemostrar experiencia en Venta y distribuci\u00f3n en el ramo de equipos m\u00e9dicos, con Contratos, facturaciones de venta y/o recepciones finales por un monto equivalente al [30] % como m\u00ednimo del monto total ofertado en la presente licitaci\u00f3n, de los \u00faltimos [3] a\u00f1os (2021, 2022, 2023).", "answer": "Remitirse a la respuesta de la consulta 25.", "dateAnswered": "2024-09-26T07:15:17-04:00"}, {"id": "ca4827d7d113de1e1cc28a4d8612600a-1", "date": "2024-09-25T22:12:47-04:00", "title": "EETT ITEM 23. 2.7", "description": "En relaci\u00f3n con la especificaci\u00f3n de \"Largo de 200 cm \u00b1 5 cm\", solicitamos a la convocante considerar ajustar las especificaciones a 210 cm \u00b1 10 cm. Este ajuste ofrecer\u00eda mayor versatilidad y comodidad, permitiendo una mayor adaptaci\u00f3n a diferentes pacientes y mejorando la funcionalidad del equipo sin comprometer su rendimiento en entornos cl\u00ednicos\u00a0exigentes.", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:25:50-04:00"}, {"id": "f2e42908def17dbbdce0ac8651977222-1", "date": "2024-09-14T11:04:20-04:00", "title": "Especificaciones T\u00e9cnicas  - \u00cdtem 16) Monitor Multiparam\u00e9trico", "description": "7.7 (dos) sistemas EEG de 8 canales por la totalidad de equipos.\n\nSolicitamos modificar el requerimiento de 'dos sistemas EEG de 8 canales por la totalidad de equipos' a 'dos sistemas EEG de 4 canales'. La reducci\u00f3n a 4 canales es suficiente para la mayor\u00eda de los procedimientos cl\u00ednicos habituales, proporcionando datos precisos sobre la actividad cerebral sin comprometer la calidad del monitoreo. Este ajuste optimiza el uso de recursos y simplifica la instalaci\u00f3n y operaci\u00f3n de los equipos, sin afectar su funcionalidad en los escenarios previstos.", "answer": "Remitirse a la Adenda en el SICP.", "dateAnswered": "2024-09-26T07:14:16-04:00"}, {"id": "6c67b8d915e8da12989dab0540c8f7ce-1", "date": "2024-09-17T17:34:12-04:00", "title": "ITEM 35", "description": "8.8 Donde dice: Transductor microconvexo con ancho de banda de 2 a 11 Mhz , solicitamos diga: Transductor microconvexo con ancho de banda de 3 a 11 Mhz", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:16:03-04:00"}, {"id": "89e846da032b3de6f13fb852f0b8c984-1", "date": "2024-09-18T13:03:36-04:00", "title": "Especificaciones T\u00e9cnicas - ITEM 51 Microscopio de fluorescencia", "description": "Donde dice \u201cManuales: Un (01) del usuario o operaci\u00f3n y un (01) manual t\u00e9cnico por equipo, que ser\u00e1n entregados en el momento de la recepci\u00f3n del equipo. Todos los manuales ser\u00e1n originales del fabricante y no fotocopias ni traducciones\u201d.\n\nSobre el manual t\u00e9cnico, informamos que el mismo no puede ser entregado, debido a que el mismo es para el uso exclusivo de cada personal t\u00e9cnico certificado del representante de cada marca, el cual ser\u00eda una violaci\u00f3n a las pol\u00edticas de representaci\u00f3n, adem\u00e1s para poder acceder al manual (online) se requiere de una autorizaci\u00f3n de la marca y no pueden ser descargados.", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:18:18-04:00"}, {"id": "709200853e1be651b5ef20f3585dd3b0-1", "date": "2024-09-14T11:05:25-04:00", "title": "Especificaciones T\u00e9cnicas  - \u00cdtem 53) Monitor Multiparam\u00e9trico", "description": "8.7 (dos) sistemas EEG de 8 canales por la totalidad de equipos.\n\nSolicitamos modificar el requerimiento de 'dos sistemas EEG de 8 canales por la totalidad de equipos' a 'dos sistemas EEG de 4 canales'. La reducci\u00f3n a 4 canales es suficiente para la mayor\u00eda de los procedimientos cl\u00ednicos habituales, proporcionando datos precisos sobre la actividad cerebral sin comprometer la calidad del monitoreo. Este ajuste optimiza el uso de recursos y simplifica la instalaci\u00f3n y operaci\u00f3n de los equipos, sin afectar su funcionalidad en los escenarios previstos.", "answer": "Remitirse a la Adenda en el SICP.", "dateAnswered": "2024-09-26T07:14:27-04:00"}, {"id": "c9654d16a935c86d1b44567d8ddc5572-1", "date": "2024-09-17T17:28:33-04:00", "title": "item 33", "description": "En el \u00edtem 33 de las Especificaciones t\u00e9cnicas donde dice \u201cAl menos 15.000.000 de canales de procesamiento digital\u201d, solicitamos a la convocante modificar este \u00edtem por \u201cAl menos 1.000.00 de canales de procesamiento digital\u201d, este ajuste se alinea con el est\u00e1ndar de equipos modulares de la gama solicitada y facilitar\u00e1 una mayor participaci\u00f3n de potenciales oferentes, promoviendo as\u00ed un proceso de adquisici\u00f3n m\u00e1s inclusivo y competitivo", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:15:42-04:00"}, {"id": "ad0155f74bb4c4bae879413004d31589-1", "date": "2024-09-18T14:18:10-04:00", "title": "\u00cdtem 16 Monitor Multiparam\u00e9trico", "description": "4.6.1 Al menos cuatro canales.\n\u00bfSe podr\u00eda considerar de al menos dos canales?", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:19:38-04:00"}, {"id": "eb7b17ada07893dca80082f9e82af632-1", "date": "2024-09-18T20:51:16-04:00", "title": "\u00cdtem 37: Equipo para tratamiento de hemodi\u00e1lisis", "description": "El PBC solicita Bater\u00eda de respaldo (autonom\u00eda de m\u00e1s de 30 min a un QB = 300 mL/min y QH= 5.0 mL/hr).Se solicita amablemente a la convocante que, de manera a permitir la competencia de marcas de gran reconocimiento a nivel mundial y experiencia comprobada en el mercado local, tambi\u00e9n considerando que centros de hemodi\u00e1lisis cuentan con respaldo de grupos electr\u00f3genos (generadores) para apoyo de suministro el\u00e9ctrico en caso de fallas en la alimentaci\u00f3n principal, por lo que planteamos la siguiente reformulaci\u00f3n del requisito: Bater\u00eda de respaldo con autonom\u00eda para funcionamiento de circuito extracorp\u00f3reo de al menos 10 minutos por fallas en el suministro de energ\u00eda el\u00e9ctrica principal, a fin de brindar mayor oportunidad de participacion a los oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:19:54-04:00"}, {"id": "ae1a56908bdeb6661bf81e0e1aeac300-1", "date": "2024-09-18T17:42:21-04:00", "title": "\u00cdtem 16 \u2013 Monitor Multiparam\u00e9trico", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 6.1 se solicita \u201cCon al menos 8 canales de EEG\u201d solicitamos a la Convocante pueda modificar este punto por \u201cCon al menos 8 derivaciones\u201d de manera a poder ajustarse a las tecnolog\u00edas disponibles en el mercado y posibilitando la participaci\u00f3n de m\u00e1s oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:33:26-04:00"}, {"id": "8e66011efcdbb9c80aa01afd78bb8ba2-1", "date": "2024-09-18T14:18:25-04:00", "title": "\u00cdtem 16 Monitor Multiparam\u00e9trico", "description": "6.1 Con al menos 8 canales de EEG\n\u00bfSe podr\u00eda cotizar con al menos 4 canales de EEG?", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:19:46-04:00"}, {"id": "7afe98665b085c4b67aa846a06f73ede-1", "date": "2024-09-18T18:50:33-04:00", "title": "Item 6 \u2013 Caja de cirug\u00eda general", "description": "Donde solicitan: Certificaci\u00f3n de la calidad de los instrum\u00e9ntales: DIM EN 10088T.1-3, EN ISO 7153-1 , y EN ISO 13485:2016, por favor aclarar que se requiere alguno de ellos.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:13:09-04:00"}, {"id": "2cf20383c98b52e5b5ae90732159ed42-1", "date": "2024-09-18T17:44:55-04:00", "title": "\u00cdtem 44 \u2013 M\u00e1quina de Anestesia", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 5.14 se solicita \u201cflujo inspiratorio m\u00e1ximo: 120LPM m\u00e1s flujo de gas fresco\u201d solicitamos a la Convocante pueda modificar este punto por \u201cflujo inspiratorio m\u00e1ximo: 180LPM m\u00e1s flujo de gas fresco\u201d de manera a adecuarse a los valores de la mayor\u00eda de las marcas presentes en el mercado y no limitar la participaci\u00f3n.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:10:32-04:00"}, {"id": "9ac2bd83acbbb25c28e382e4e1969c82-1", "date": "2024-09-18T22:33:24-04:00", "title": "ID 443857 - \u00cdtem 34 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Transductor Convexo con un ancho de banda de 1 MHz o menor a 5 MHz o mayor. Con profundidad de escaneo hasta 44 cm o mayor. Compatible para uso de elastosonograf\u00eda. Cantidad: 01 (Uno) por cada equipo\" solicitamos a la convocante modificar este punto a \"Transductor Convexo con un ancho de banda de 1.5 MHz o menor a 5 MHz o mayor. Con profundidad de escaneo hasta 30 cm o mayor. Compatible para uso de elastosonograf\u00eda. Cantidad: 01 (Uno) por cada equipo\" dichos par\u00e1metros son est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos que modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:34:59-04:00"}, {"id": "91dfcce34c863c6c210053a818679d96-1", "date": "2024-09-13T12:15:39-04:00", "title": "\u00cdtem 51  Microscopios de fluorescencia", "description": "En el punto 5.5  se establece - No modifica altura del microscopio.\nFavor indicar a que se refieren con esta exigencia? Que altura total del sistema se requiere?", "answer": "Remitirse a la Adenda en el SICP.", "dateAnswered": "2024-09-26T07:09:26-04:00"}, {"id": "fa09255c2e13fb0c216f51fc9540c7ec-1", "date": "2024-09-18T17:43:41-04:00", "title": "\u00cdtem 42 \u2013 Ventilador Pulmonar de Alta Complejidad", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 9.13 se solicita \u201cPantalla secundaria para control y monitorizaci\u00f3n del ventilador de 19\" \u00b1 2\". Conexi\u00f3n a la pantalla principal al\u00e1mbrica o inal\u00e1mbrica. Una (1) unidad por la totalidad de equipos incluyendo el carro para la pantalla secundaria.\u201d Solicitamos a la Convocante eliminar este punto, ya que esto no significa una mejora en la ventilaci\u00f3n o una tecnolog\u00eda superior que permita maniobras especiales o significativas a favor del paciente, esto simplemente es entregar un televisor. Recomendamos a la Convocante pensar en implementar una conectividad real entre los equipos, donde puedan desplegar tanto los par\u00e1metros ventilatorios como de los demas equipos de las terapias a una central m\u00e9dica, con registros de los pacientes y de los eventos de los equipos.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:34:08-04:00"}, {"id": "0b6c669e9e62815c011907535bc40ed9-1", "date": "2024-09-18T22:47:38-04:00", "title": "CAPACIDAD TECNICA", "description": "El punto 4 solicita: Presentar certificados y/o constancias de haber participado en cursos de entrenamiento, capacitaci\u00f3n y familiarizaci\u00f3n del equipo ofertado y sus programas del personal t\u00e9cnico de la empresa emitida por el fabricante de la marca ofertada.\nSolicitamos eliminar este criterio ya que corresponde a la misma documentaci\u00f3n requerida en el punto 11", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:36:34-04:00"}, {"id": "2ea51e4083547f68099aaffd34863881-1", "date": "2024-09-25T14:32:47-04:00", "title": "\u00cdtem 4_ Biometro", "description": "En el numeral 4.2 de las especificaciones t\u00e9cnicas la Convocante solicita:\nBiometro \u00f3ptico por fuente de barrido l\u00e1ser con Topograf\u00eda (Swept Source laser)\nSolicitamos a la Convocante eliminar la parte que dice \u201c(Swept Source laser)\u201d; porque esta descripci\u00f3n es una caracter\u00edstica espec\u00edfica del modelo IOL Mater de la marca Zeiss.", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:24:36-04:00"}, {"id": "4bc9e41c3942255222145c1cc9cc1dd7-1", "date": "2024-09-18T22:28:48-04:00", "title": "\u00edtem 34 - Ec\u00f3grafo", "description": "Para el \u00edtem 34 Donde dice \"Los equipos deber\u00e1n contar con 2 (dos) a\u00f1os de garant\u00eda desde la puesta en funcionamiento, e incluir como m\u00ednimo 1 (un) mantenimiento preventivo anual durante dicho periodo\" solicitamos a la convocante aclarar si la garant\u00eda debe incluir repuestos y materiales de desgaste como son los transductores. Adem\u00e1s, solicitamos confirmar que la garant\u00eda no incluir\u00e1 los da\u00f1os que pudiere sufrir el equipo por errores de utilizaci\u00f3n y/o golpes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:33:54-04:00"}, {"id": "288e69ff3f931f0cb735653859d64954-1", "date": "2024-09-18T20:56:00-04:00", "title": "\u00cdtem 37: Equipo para tratamiento de hemodi\u00e1lisis", "description": "El PBC solicita Concentraci\u00f3n total: 10 a 17 mS/cm.Se solicita amablemente a la convocante que, de manera a permitir la competencia de marcas de gran reconocimiento a nivel mundial y experiencia comprobada en el mercado local, atendiendo a rangos reales de ajuste del par\u00e1metro mencionado, por lo que solicitamos sean aceptados equipos con Concentraci\u00f3n total (mS/cm): 12.8 o menor a 15.7 o mayor, a fin de brindar mayor oportunidad de participacion a los oferentes", "answer": "Se encuentra dentro del parametro solicitado.", "dateAnswered": "2024-09-26T08:26:55-04:00"}, {"id": "e4ef24a865ba598bf10e391a1f3e481a-1", "date": "2024-09-18T22:22:51-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Donde dice \"Monitor de al menos 23 pulgadas LCD, montado en brazo articulado, con resoluci\u00f3n de al menos} 1920x1080 pixeles\" solicitamos a la convocante modificar este punto a \"Monitor de al menos 21 pulgadas LCD, montado en brazo articulado, con resoluci\u00f3n de al menos} 1920x1080 pixeles\" La diferencia solicitada es m\u00ednima, adem\u00e1s, lo solicitado constituye una caracter\u00edstica meramente constructiva que no afecta a la calidad de imagen. Por lo que solicitamos que modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:29-04:00"}, {"id": "b08c59d91bd925de82ff4edd4633da4d-1", "date": "2024-09-17T17:50:05-04:00", "title": "ITEM 35", "description": "En el \u00edtem 35 de las Especificaciones t\u00e9cnicas donde dice \u201cM\u00f3dulo de respiraci\u00f3n integrado con despliegue de curva de respiraci\u00f3n.\u201d esta modificaci\u00f3n es necesaria ya que no es una especificaci\u00f3n est\u00e1ndar en los equipos port\u00e1tiles lo que limita considerablemente la competencia y esto permitir\u00e1 una mayor flexibilidad en las ofertas y la participaci\u00f3n de potenciales oferentes, sin comprometer la funcionalidad esencial del equipo.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:17:12-04:00"}, {"id": "9f1076c632a9c926bf379b1de7bab091-1", "date": "2024-09-18T22:36:20-04:00", "title": "ID 443857 - \u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Dos puertos activos para conexi\u00f3n de transductores integrados al equipo sin necesidad del uso de adaptadores\" solicitamos a la convocante modificar este punto a \"Al menos Un puerto activo para conexi\u00f3n de transductores integrados al equipo sin necesidad del uso de adaptadores\" lo solicitado constituye una caracter\u00edstica meramente constructiva que no afecta al diagn\u00f3stico ni a la calidad de imagen. Por lo que solicitamos modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:35:36-04:00"}, {"id": "72c5e84161b2571cce4976e276909b6f-1", "date": "2024-09-18T21:03:14-04:00", "title": "\u00cdtem 37: Equipo para tratamiento de hemodi\u00e1lisis", "description": "El PBC solicita Desinfecci\u00f3n qu\u00edmica y t\u00e9rmica, programables, con hasta 10 etapas. Se solicita amablemente a la convocante que, de manera a permitir la competencia de marcas de gran reconocimiento a nivel mundial y experiencia comprobada en el mercado local, y sin ir en detrimento de lo solicitado, atendiendo  a que cada maquina cuenta con los procesos necesarios que garantizan la limpieza, descalcificaci\u00f3n y desinfecci\u00f3n del sistema hidraulico independientemente de las cantidades de secuencias o etapas propias de marcas en particular, por lo que planteamos la siguiente reformulacion del requisito: Desinfecci\u00f3n qu\u00edmica y t\u00e9rmica, programables, a fin de brindar mayor oportunidad de participacion a los oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:27:08-04:00"}, {"id": "14c9ead8c62a1409b5d0d360c5de516c-1", "date": "2024-09-18T19:31:07-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 35. Punto 4.10", "description": "\u201cAl menos 4.000.000 de canales digitales de procesamiento\u201d Solicitamos a la convocante considerar ajustar el requerimiento de canales digitales de procesamiento a partir de 200.000 o m\u00e1s. El n\u00famero de 4.000.000 de canales digitales es excesivo para un ec\u00f3grafo port\u00e1til y puede no ser necesario para cumplir con los requisitos cl\u00ednicos t\u00edpicos. Un rango de 200.000 canales a\u00fan proporciona un rendimiento robusto mientras que permite una mayor flexibilidad en la selecci\u00f3n del equipo y posiblemente reduce el costo.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:18:06-04:00"}, {"id": "f2d16cd25dcbcd377f0cc9c50cc865fc-1", "date": "2024-09-18T11:13:27-04:00", "title": "ITEM 19 - Caja de curaci\u00f3n", "description": "ITEM 19 - Caja de curaci\u00f3n -\nEn una parte de las especificaciones t\u00e9cnicas dice: Todos los instrumentales son de material de acero Inoxidable quir\u00fargico, demostrado por Certificados de calidad de la CE e ISO 13485.\nSolicitamos al convocante permita cotizar certificado de calidad de la CE e ISO 13485 (al menos una de ellas).", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:18:11-04:00"}, {"id": "941dcd9ab5ae85f1fd260efca0e088f2-1", "date": "2024-09-18T22:47:09-04:00", "title": "Plazo de reposici\u00f3n de bienes", "description": "El plazo de reposici\u00f3n de bienes para reparar o reemplazar ser\u00e1 de: De 5 (cinco) d\u00edas h\u00e1biles posterior a la comunicaci\u00f3n al proveedor.\nSolicitamos ampliar el plazo de reposici\u00f3n a 30 d\u00edas", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:36:32-04:00"}, {"id": "ef50941f8f621da9801d0f1c07dc11ef-1", "date": "2024-09-18T18:44:53-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 33. Punto 2.1", "description": "\u201cMonitor de al menos 23 pulgadas LCD, montado en brazo articulado, con resoluci\u00f3n de al menos 1920x1080 pixeles\u201d Solicitamos a la convocante que considere especificar un rango de tama\u00f1o de monitor entre 21 y 24 pulgadas, en lugar de establecer una \u00fanica medida de 23 pulgadas. Esto permitir\u00e1 una mayor flexibilidad en las propuestas sin comprometer la calidad o las caracter\u00edsticas t\u00e9cnicas necesarias para el equipo, facilitando la participaci\u00f3n de m\u00e1s oferentes y asegurando la competitividad en el proceso de licitaci\u00f3n.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:12:13-04:00"}, {"id": "391bbb42310c86493f17c5534cc45ba6-1", "date": "2024-09-18T22:23:10-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Donde dice \"Panel de control ajustable en altura y rotaci\u00f3n\" solicitamos a la convocante considerar este punto a OPCIONAL, lo solicitado es una caracter\u00edstica constructiva que no se traduce en una mejora en la calidad de imagen o en el diagnostico, por lo que limita innecesariamente una mayor participaci\u00f3n de oferentes, por lo que solicitamos que modifiquen este punto a fin de tener mayor cantidad de oferentes potenciales.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:36-04:00"}, {"id": "c05963acad8a010de8c63c5fd6cc6e60-1", "date": "2024-09-18T14:19:46-04:00", "title": "\u00cdtem 31 Set para cirug\u00eda laparosc\u00f3pica", "description": "3.4 Capacitaci\u00f3n a usuarios sobre el funcionamiento del equipo y capacitaci\u00f3n t\u00e9cnica al personal t\u00e9cnico del Departamento de Electromedicina. Presentar declaraci\u00f3n jurada.\nSolicitamos excluir este requisito, considerando que no se trata de un equipo m\u00e9dico", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:22:37-04:00"}, {"id": "2160dd38b119a3a04faf275c20e2def0-1", "date": "2024-09-18T18:04:36-04:00", "title": "item 42", "description": "4.22 Solicitan Nebulizador con tecnolog\u00eda de malla vibratoria o ultras\u00f3nico, solicitamos diga: 4.22 Nebulizador incorporado para mayor participaci\u00f3n de oferentes", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:11:41-04:00"}, {"id": "483209dfdfc0cd931245fffe3421e2d2-1", "date": "2024-09-18T19:14:52-04:00", "title": "Item 56 Incubadora + Servocuna", "description": "En el \u00cdtem 56 Incubadora +Servocuna:  solicitan en el punto 2.1 Tecnolog\u00eda de microprocesadores o microcontroladores, capaz de funcionar como incubadora o como servocuna en unidades de terapia intensiva neonatal, solicitamos a la convocante poder cotizar una de las dos opciones solicitadas en el pliego de esta manera la convocante esta dirigiendo \u00fanicamente dichas especificaciones a la empresa LCM.", "answer": "El equipo solicitado corresponde a un equipo hibrido comercializado en nuestro pais por varias marcas. Refiere a una nueva tecnologia solicitada por el servicio.", "dateAnswered": "2024-09-26T08:16:29-04:00"}, {"id": "aa52f2acee5a43ba79d25aca62686c5a-1", "date": "2024-09-18T14:32:46-04:00", "title": "\u00cdTEM 33 ECOCARDI\u00d3GRAFO", "description": "Se solicita a la convocante admitir  transductor sectorial o phased array pedi\u00e1trico con ancho de banda de 3,0 a 11,4 MHz, para dar mayor participaci\u00f3n a oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:23:07-04:00"}, {"id": "9fda995d1fdb6fe1624e47a4aa83f54d-1", "date": "2024-09-18T22:37:36-04:00", "title": "\u00cdtem 38 \u2013 Equipo de Rayos X M\u00f3vil", "description": "Donde dice \"Capacidad de hasta 2.500 im\u00e1genes con las bater\u00edas cargadas a raz\u00f3n de 1 imagen cada 15 segundos o mejor\" solicitamos a la convocante modificar este punto a \"Capacidad de hasta 840 im\u00e1genes o mejor con las bater\u00edas cargadas a raz\u00f3n de 1 imagen cada 30 segundos o mejor\" lo solicitado es el est\u00e1ndar en la mayor\u00eda de los equipos de rayos x m\u00f3vil y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos se actualice este punto a fin de tener la participaci\u00f3n de las marcas con reconocida representaci\u00f3n y comprobada calidad en el mercado local e internacional. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 38 est\u00e1n direccionadas a la marca SHIMADZU modelo MobileArt Eco MUX-10, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:35:57-04:00"}, {"id": "47699cc9eebab9639b1930bc32a4c5e1-1", "date": "2024-09-18T22:30:50-04:00", "title": "ID 443857 - \u00cdtem 34 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Profundidad de imagen m\u00e1xima de 44 cm o mayor\" solicitamos a la convocante modificar este punto a \"Profundidad de imagen m\u00e1xima de 30 cm o mayor\" dicho par\u00e1metro solicitado es est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos que modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:34:46-04:00"}, {"id": "037e370cd7571d60ef5d88d61484acb2-1", "date": "2024-09-18T22:23:44-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Donde dice \"Rango Din\u00e1mico de al menos 350dB\" solicitamos a la convocante modificar este punto a \"Rango Din\u00e1mico de al menos 260dB\" lo solicitado obedece a que esta caracter\u00edstica no afecta al estudio ni a la calidad de imagen, por lo que limita innecesariamente una mayor participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:44-04:00"}, {"id": "c707f02311025d45bc7428e9f42c0a55-1", "date": "2024-09-18T17:42:58-04:00", "title": "\u00cdtem 42 \u2013 Ventilador Pulmonar de Alta Complejidad", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 6.20 se solicita \u201cTiempo espiratorio 0,1 a 103 seg \u00b1 5 seg\u201d solicitamos a la Convocante pueda modificar este punto por \u201cTiempo espiratorio 0,1 a 10 seg \u00b1 5 seg\u201d de manera a ajustarse a los valores normales de este par\u00e1metro. Esta modificaci\u00f3n permite la participaci\u00f3n de m\u00e1s oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:33:48-04:00"}, {"id": "c4bcfe4e6dfe1a5ce23aa585470e8206-1", "date": "2024-09-17T17:33:53-04:00", "title": "ITEM 34", "description": "En el \u00edtem 34 de las Especificaciones t\u00e9cnicas donde dice \u201cRango Din\u00e1mico de al menos 350 dB.\u201d, solicitamos a la convocante la modificaci\u00f3n de este \u00edtem por \u201cRango din\u00e1mico de al menos 280 dB\u201d, La mayor\u00eda de los procedimientos cl\u00ednicos no demandan un rango din\u00e1mico de 350 dB. y la modificaci\u00f3n de este \u00edtem a 280 dB alinea el equipo con las necesidades reales de los usuarios y las normativas vigentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:15:54-04:00"}, {"id": "b2772c772310d830da6d62011c0e6f2c-1", "date": "2024-09-18T22:41:19-04:00", "title": "\u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Software para medici\u00f3n autom\u00e1tica de la fracci\u00f3n de eyecci\u00f3n en modo 2D con reconocimiento automatico\" solicitamos a la convocante considerar este punto como OPCIONAL debido a que esta caracter\u00edstica encarece significativamente el precio referencial del ec\u00f3grafo requerido. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:27-04:00"}, {"id": "30ef44e780731937d285813cb23b70c1-1", "date": "2024-09-23T14:57:19-04:00", "title": "INSPECCIONES Y PRUEBAS", "description": "En el punto 4 expresa lo siguiente: Cuando el proveedor est\u00e9 listo para realizar dichas pruebas e inspecciones, notificar\u00e1 oportunamente a la contratante indic\u00e1ndole el lugar y la hora. \nCual seria el plazo posterior a la entrega del bien para la puesta en marcha y funcionamiento del equipo.", "answer": "El Oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:23:55-04:00"}, {"id": "838b5c8628639b5b2d2f707019f0544c-1", "date": "2024-09-18T15:24:50-04:00", "title": "Item N\u00b0 37 \u2013 Equipo de Hemodialisis", "description": "Solicitamos poder ofertar equipos con un rango de temperatura de 33\u00b0C a 40\u00b0C, ya que dicho rango permite mantener una temperatura adecuada para los pacientes durante el tratamiento de hemodi\u00e1lisis. Ya que a nivel de est\u00e1ndares internacionales, se sugiere que la temperatura del dializado se mantenga en un rango seguro y ajustable, generalmente entre 35\u00b0C y 38\u00b0C.", "answer": "Se encuentra dentro del rango.", "dateAnswered": "2024-09-26T07:24:12-04:00"}, {"id": "5080029ffd1b6f580eea8199e34c3f5a-1", "date": "2024-09-18T22:39:30-04:00", "title": "\u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Transductor Phased Array neonatal con un ancho de banda de 6 a 13 Mhz. Cantidad: 1 (una) unidad por equipo\" solicitamos a la convocante modificar este punto a \"Transductor Phased Array neonatal con un ancho de banda de 3 Mhz o menor a 8 Mhz o mayor. Cantidad: 1 (una) unidad por equipo\" dichos par\u00e1metros son est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:12-04:00"}, {"id": "b5016c808fd58eef62771cb82bdcb5d5-1", "date": "2024-09-18T18:31:17-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 35 Punto 4.4", "description": "\"Panel de control retroiluminado y pantalla t\u00e1ctil integrado a la consola del equipo para acceso r\u00e1pido a las principales funciones del equipo con teclado alfanum\u00e9rico.\" Observamos que el requerimiento de \"pantalla t\u00e1ctil integrada a la consola del equipo para acceso r\u00e1pido a las principales funciones del equipo\" parece estar espec\u00edficamente dirigido a un modelo en particular, como el Vinno 6. Solicitamos considerar la eliminaci\u00f3n de esta especificaci\u00f3n para permitir una mayor flexibilidad en la participaci\u00f3n de proveedores. Existen otras soluciones igualmente efectivas para el acceso r\u00e1pido a las funciones del equipo, como paneles de control retroiluminados con teclado alfanum\u00e9rico, que tambi\u00e9n cumplen con los objetivos funcionales sin limitar la competencia.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:12:04-04:00"}, {"id": "3cf2eef3ee01a77ecd9fb9de50b93453-1", "date": "2024-09-18T19:26:04-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 34. Punto 4.10", "description": "\u201cCapacidad de almacenamiento en disco de estado s\u00f3lido (SSD) de al menos 512 GB.\u201d Solicitamos a la convocante que ajuste la especificaci\u00f3n de \"Capacidad de almacenamiento en disco de estado s\u00f3lido (SSD) de al menos 512 GB\" a un rango de 500 GB o m\u00e1s. Esto permitir\u00e1 una mayor flexibilidad en la selecci\u00f3n del equipo y asegurar\u00e1 que se mantengan opciones viables tanto en t\u00e9rminos de costo como de capacidad para cumplir con los requisitos operativos del equipo.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:17:14-04:00"}, {"id": "ef3760d6d97550ad4a97c7ba0163cf76-1", "date": "2024-09-18T14:33:18-04:00", "title": "\u00cdTEM 35 EC\u00d3GRAFO", "description": "Se solicita a la convocante dejar como opcional la posibilidad de admitir transductor transesof\u00e1gico, para dar mayor participaci\u00f3n a oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:23:30-04:00"}, {"id": "6355d19f00aeb7e161f49b6e9261ddce-1", "date": "2024-09-18T22:37:50-04:00", "title": "ID 443857 - \u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Trackball para movimiento del puntero\" solicitamos a la convocante modificar este punto a \"Trackball o Trackpad multitactil para movimiento del puntero\" lo solicitado constituye una caracter\u00edstica meramente constructiva que no afecta al diagn\u00f3stico ni a la calidad de imagen. Por lo que solicitamos modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:00-04:00"}, {"id": "9d6e66249aa19d84c662d7c5f28c9262-1", "date": "2024-09-18T17:41:08-04:00", "title": "\u00cdtem 53 \u2013 Monitor Multiparam\u00e9trico", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 7 se solicita \u201cEEG\u201d y en los puntos siguientes desde el punto 7.1 hasta el punto 7.9 las caracter\u00edsticas de este par\u00e1metro, solicitamos a la convocante eliminar estos puntos ya que lo solicitado es un par\u00e1metro exclusivo de un Monitor de Alta complejidad y no se ajusta a las especificaciones de un Monitores de Baja Complejidad tal como se solicita en el punto 4.1. Asi tambien solicitamos eliminar los accesorios solicitados en los puntos 8.7 al 8.8.4 que corresponden a accesorios para EEG. Estas modificaciones permitir\u00e1n la participaci\u00f3n de un mayor n\u00famero de oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:33:18-04:00"}, {"id": "7fd4b3b90c79e7b00043b18d093524ef-1", "date": "2024-09-25T17:54:56-04:00", "title": "ESPECIFICACIONES TECNICAS - ITEM 20 4.4", "description": "Donde se solicita \"Dimensiones de la superficie para el paciente. Longitud m\u00ednima 190 cm \u00b1 5 cm, Ancho m\u00ednimo 80 cm \u00b1 5 cm\", solicitamos a la convocante considerar ajustar las especificaciones a 200 cm \u00b1 10 cm de longitud y 90 cm \u00b1 10 cm de ancho. Estas medidas ofrecen mayor comodidad para el paciente y permiten una mayor flexibilidad en el uso de colchones y accesorios cl\u00ednicos, sin comprometer la funcionalidad o adaptabilidad del equipo en entornos\u00a0cr\u00edticos", "answer": "Respondido en la Consulta 66.", "dateAnswered": "2024-09-26T14:25:15-04:00"}, {"id": "b5db2eac4ba4725946c351312c62fb96-1", "date": "2024-09-25T14:32:16-04:00", "title": "\u00cdtem 4_ Biometro", "description": "\u00cdtem 4_ Biometro\nEn el numeral 4.2 de las especificaciones t\u00e9cnicas la Convocante solicita:\nBiometro \u00f3ptico por fuente de barrido l\u00e1ser con Topograf\u00eda (Swept Source laser)\nSolicitamos respetuosamente al Convocante permitir la cotizaci\u00f3n de equipo:\nBiometro \u00f3ptico por fuente de barrido l\u00e1ser con Topograf\u00eda (Swept Source laser) o T-cone (denominaci\u00f3n del fabricante).", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:24:34-04:00"}, {"id": "6af7f08f3f723bcafeae6fc154832b12-1", "date": "2024-09-18T17:43:45-04:00", "title": "\u00cdtem 44 \u2013 M\u00e1quina de Anestesia", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 4.5 se solicita \u201cV\u00e1lvula de sobrepresi\u00f3n (ALP) DE 0 a 70 cm de H2O\u201d solicitamos a la Convocante pueda modificar este punto por \u201cV\u00e1lvula de sobrepresi\u00f3n (ALP) DE 5 cm de H2O o menor a 70 cm de H2O o mayor\u201d de manera a adecuarse a los valores de la mayor\u00eda de las marcas presentes en el mercado y no limitar la participaci\u00f3n.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:36:29-04:00"}, {"id": "1b47cf40f5866f3b53980ecfc9e8ed0c-1", "date": "2024-09-17T17:27:45-04:00", "title": "\u00edtem 33 de las Especificaciones T\u00e9cnicas", "description": "En relaci\u00f3n con el \u00edtem 33 de las Especificaciones T\u00e9cnicas, donde se solicita un \u201cFrame Rate de 6600 Hz o mayor\u201d, solicitamos la modificaci\u00f3n a \u201cFrame Rate de 1800 Hz o mayor\u201d. Este ajuste ofrece un equilibrio adecuado entre calidad, costos y capacidad t\u00e9cnica y se alinea con los est\u00e1ndares del sector y promover\u00e1 una mayor participaci\u00f3n de oferentes.", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:15:29-04:00"}, {"id": "6c249d8df7671ac38ecdc6bc3ed339d7-1", "date": "2024-09-18T14:20:16-04:00", "title": "\u00cdtem 53 Monitor multiparam\u00e9trico", "description": "Solicitamos revisar por completo las especificaciones t\u00e9cnicas de este \u00edtem, teniendo en cuenta que son copia de lo solicitado en el \u00edtem 16 y en el \u00edtem 53 se pretende adquirir monitores de baja complejidad, seg\u00fan el 4.1 y el precio referencial fijado", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:22:51-04:00"}, {"id": "a7e6d073eee802a4d3f787d323ff4852-1", "date": "2024-09-18T22:35:41-04:00", "title": "ID 443857 - \u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Movimiento rotativo del monitor para facilitar la operaci\u00f3n del usuario\"  solicitamos a la convocante considerar este punto como OPCIONAL, lo solicitado constituye una caracter\u00edstica meramente constructiva que no afecta al diagn\u00f3stico ni a la calidad de imagen. Por lo que solicitamos modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:35:23-04:00"}, {"id": "c4233c9539731c010a3260e50c3cd618-1", "date": "2024-09-18T23:14:26-04:00", "title": "Item 35 - Ecografo", "description": "Donde dice \"El sistema debe ser capaz de medir autom\u00e1ticamente la fracci\u00f3n de eyecci\u00f3n en cortes de 4 c\u00e1maras y 2 c\u00e1maras\" solicitamos a la convocante considerar este punto como OPCIONAL debido a que esta caracter\u00edstica encarece significativamente el precio referencial del ec\u00f3grafo requerido. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:51-04:00"}, {"id": "50bfd6249b8d5a555712c144c6b94ddd-1", "date": "2024-09-18T19:15:35-04:00", "title": "Plan de entrega de los bienes", "description": "En el PBC En el Punto Plan de Entrega de los bienes y el cronograma de Entrega solicitan que las entregas sean el 100% dentro de los 30 d\u00edas a partir de la firma del contrato, solicitamos a la convocante que los plazos de entrega sean a 120 dias a partir de la firma del contrato esto obedece a que muchos de los productos solicitados el tiempo de fabricaci\u00f3n es como m\u00ednimo de 45 d\u00edas y a eso debemos de agregar el plazo de transporte.", "answer": "Remitirse a la respuesta de la consulta 1.", "dateAnswered": "2024-09-26T08:16:55-04:00"}, {"id": "6e51e3de0d5592296197c526a09c7602-1", "date": "2024-09-18T18:52:30-04:00", "title": "Item 36 \u2013 Electrocardiografo", "description": "En el punto 36 5.14 HL7/DICOM para conexiones a HIS y RIS, solicitamos por favor el HL7 sea considerado opcional.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:15:21-04:00"}, {"id": "53c0f82212aa817cc1664a7726761a0d-1", "date": "2024-09-18T22:08:01-04:00", "title": "ITEM 44 \u2013 MAQUINA DE ANESTESIA", "description": "En el punto 4.1 donde dice \u201cCanister reutilizable y esterilizable con capacidad m\u00e1xima de 2,5 litros o su equivalente en gramos\u201d solicitamos a la convocante permita la cotizacion de equipos con canister reutilizable y esterilizable de al menos 1.5 litros o mayor, esto considerando los valores disponibles del mercado y asi dar participaci\u00f3n a potenciales oferentes", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:08-04:00"}, {"id": "3900320b05fa8d0fa941424e4c34bfe4-1", "date": "2024-09-18T18:50:37-04:00", "title": "Item 8 \u2013 Caja de cirug\u00eda menor", "description": "Donde solicitan: Certificaci\u00f3n de la calidad de los instrum\u00e9ntales: DIM EN 10088T.1-3, EN ISO 7153-1 , y EN ISO 13485:2016, por favor aclarar que se requiere alguno de ellos.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:13:12-04:00"}, {"id": "935cbd0691b070d22c697146967007fe-1", "date": "2024-09-18T18:50:30-04:00", "title": "Item 5 \u2013 Caja de cirug\u00eda especializada", "description": "Donde solicitan: Certificaci\u00f3n de la calidad de los instrum\u00e9ntales: DIM EN 10088T.1-3, EN ISO 7153-1 , y EN ISO 13485:2016, por favor aclarar que se requiere alguno de ellos", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:13:06-04:00"}, {"id": "7ce9ef38effc1393f7bdb388ae49e4b2-1", "date": "2024-09-18T17:01:39-04:00", "title": "ITEM 1 1 2.6 Ajuste de la intensidad de la presi\u00f3n", "description": "Para este punto se solicita que sea opcional ya que con el mando de regulaci\u00f3n de vaci\u00f3 uno aumenta la fuerza de succi\u00f3n que es reflejada en el manometro de presi\u00f3n.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:27:58-04:00"}, {"id": "59b90d896b48bdb18c41ddf0153103ef-1", "date": "2024-09-18T19:15:05-04:00", "title": "item 20 Cama electrica", "description": "En el Item 20 Cama el\u00e9ctrica a para paciente: En el punto 4.10 Sistema de protecci\u00f3n y gu\u00eda rotatoria antigolpes en las 4 esquinas de la cama, solicitamos a la convocante si este punto pueda ser opcional, de esta manera se podr\u00eda dar mayor participaci\u00f3n a empresas que tiene de forma est\u00e1ndar la fabricaci\u00f3n sin gu\u00eda rotatoria", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:16:40-04:00"}, {"id": "7855cc9d8636df5a184f438b5bd62313-1", "date": "2024-09-18T17:43:48-04:00", "title": "\u00cdtem 44 \u2013 M\u00e1quina de Anestesia", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 4.5 se solicita \u201cV\u00e1lvula de sobrepresi\u00f3n (ALP) DE 0 a 70 cm de H2O\u201d solicitamos a la Convocante pueda modificar este punto por \u201cV\u00e1lvula de sobrepresi\u00f3n (ALP) DE 5 cm de H2O o menor a 70 cm de H2O o mayor\u201d de manera a adecuarse a los valores de la mayor\u00eda de las marcas presentes en el mercado y no limitar la participaci\u00f3n.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:09:54-04:00"}, {"id": "575a62159f0dbd2f9625ace70bde24ac-1", "date": "2024-09-18T22:23:33-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Donde dice \"Al menos 15.000.000 de canales de procesamiento digital\" solicitamos a la convocante modificar este punto a \"Al menos 172.000 canales de procesamiento digital\" Lo solicitado obedece a que cada casa comercial calcula los canales de procesamiento digitales mediante una f\u00f3rmula matem\u00e1tica propia, que no se ha estandarizado en el mercado y lo cual hace que los n\u00fameros de canales digitales no sean comparables entre una marca y otra.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:41-04:00"}, {"id": "72ab5ba11763c4e36b78153c4e8d4027-1", "date": "2024-09-14T11:04:58-04:00", "title": "Especificaciones T\u00e9cnicas  - \u00cdtem 53) Monitor Multiparam\u00e9trico", "description": "7.1 Con al menos 8 canales de EEG\n\nSolicitamos modificar el requerimiento de al menos 8 canales de EEG a 4 canales, ya que en muchos casos cl\u00ednicos rutinarios, 4 canales son suficientes para obtener informaci\u00f3n precisa y relevante sobre la actividad cerebral del paciente. Esta reducci\u00f3n no compromete la calidad del monitoreo en entornos donde no se requiere una alta resoluci\u00f3n de datos, adem\u00e1s de que simplifica el an\u00e1lisis y optimiza el uso de recursos. La reducci\u00f3n a 4 canales permite un equipo m\u00e1s accesible y eficiente sin perder eficacia diagn\u00f3stica en la mayor\u00eda de los escenarios cl\u00ednicos.", "answer": "Remitirse a la Adenda en el SICP.", "dateAnswered": "2024-09-26T07:14:22-04:00"}, {"id": "b40b0e7445e7e8b45bf45872fdbddee8-1", "date": "2024-09-18T15:47:15-04:00", "title": "Especificaciones T\u00e9cnicas: \u00cdtem 10 - SET DE INSTRUMENTALES PARA CAJA DE ABDOMEN \u2013 TORAX.", "description": "En el punto 2.39 donde solicitan 1 MANGO BISTUR\u00cd NO. 4 LARGO, de 15 a 16 cm de longitud\n\nFavor considerar aceptar y/o modificar la longitud del material a 21,5 (+/- 1cm) considerando que esta medida es la mas utilizada para este tipo de cirug\u00edas donde se necesita instrumentales largos por la profundidad.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:24:19-04:00"}, {"id": "0e50612b8aeb9b41b6c8ab8cba4e780d-1", "date": "2024-09-18T16:06:31-04:00", "title": "item 36. Electrocardiografo", "description": "5.13 Solicitan 4 puertos USB como m\u00ednimo, Soicitamos diga: 3 puertos USB como m\u00ednimo", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:26:32-04:00"}, {"id": "0408d6e5d7cb0f1f7cbfb2d2040a481e-1", "date": "2024-09-18T22:49:16-04:00", "title": "SOPORTE TECNICO", "description": "Punto 8.6 SOPORTE TECNICO: Soporte t\u00e9cnico durante el tiempo de duraci\u00f3n de la garant\u00eda. Presentar declaraci\u00f3n jurada.\n Solicitamos a la convocante pueda ser modificada este criterio de la siguiente manera: Soporte t\u00e9cnico durante el tiempo de duraci\u00f3n de la garant\u00eda del bien ofertado.  Presentar declaraci\u00f3n jurada.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:39-04:00"}, {"id": "eca11c74cc87be63a0acc57025c361ea-1", "date": "2024-09-18T22:02:36-04:00", "title": "Item 42 Ventilador Pulmonar", "description": "En el punto 6.9 donde dice \u201cVolumen Corriente VT inspiratorio, Vte espiratorio, Vtspon de 0 a 3500 ml, o mejor\u201d solicitamos a la convocante considere el par\u00e1metro Vtspon como opcional.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:27:43-04:00"}, {"id": "b4c961748c753b495601fc42113901ad-1", "date": "2024-09-18T17:01:46-04:00", "title": "ITEM 1 1 2.9  El equipo permitir\u00e1 el acople de 2 frascos recolectores, de 5 litros cada una, totalizando en su m\u00e1xima capacidad hasta 10 litros;", "description": "Para este punto se solicita a la convocante aclarar en el pliego si es 5 litros utilizable ya que con la v\u00e1lvula anti desborde resta capacidad de absorci\u00f3n. Se solicita acepar frascos colectores de 4L (util 3.5L) totalizando 7 litros util de capacidad. De este modo habran mas oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:28:02-04:00"}, {"id": "041c06931e2403070133edb9f210fc90-1", "date": "2024-09-13T16:32:38-04:00", "title": "Item N\u00b0 37 \u2013 EETT.", "description": "Solicitamos amablemente a la convocante modificar donde dice: \u201cPunto 2.9 \u2013 Bater\u00eda de respaldo (autonom\u00eda de m\u00e1s de 30 minutos a un QB = 300 mL/min y QH = 5.0 mL/min)\u201d debe decir: \u201cBater\u00eda de respaldo (autonom\u00eda de m\u00e1s de 30 minutos a un QB = 300 mL/min)\u201d, puesto que en cualquier equipo de di\u00e1lisis la bater\u00eda de respaldo solo funciona para retornar la sangre al paciente, ya que no es posible continuar con el tratamiento de di\u00e1lisis, por lo que no es necesario el funcionamiento de la QH o Bomba de heparina.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:09:29-04:00"}, {"id": "10158c6411b70c39f08debe705636f8a-1", "date": "2024-09-18T19:30:26-04:00", "title": "ITEM 38 \u2013 Equipo de rayos x portatil", "description": "En el punto 3.2 donde dice  \u201cAncho total de 710 mm \u00b1 20 mm\u201d solicitamos amablemente a la convocante permita la cotizacion de equipos de ancho de 610 mm o mayor considerando que el valor solicitado es mejor para su utilizaci\u00f3n en los servicios de un hospital tales como la terapia o hospitalizaci\u00f3n, asi tambien para dar participaci\u00f3n a potenciales oferentes. Entonces solicitamos que el item quede de la siguiente manera: Ancho total de 610 mm \u00b1 20 mm\u201d", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:17:45-04:00"}, {"id": "5e69162e813aa8fb56fb98e88f65aef9-1", "date": "2024-09-18T17:52:45-04:00", "title": "\u00cdTEM 35 EC\u00d3GRAFO", "description": "6.5 Se solicita a la convocante  admitir Disco duro de estado s\u00f3lido con capacidad desde 128 GB, para dar mayor participaci\u00f3n a oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:11:39-04:00"}, {"id": "eb3c452de6f307e3b65665c122c7f174-1", "date": "2024-09-18T14:33:12-04:00", "title": "\u00cdTEM 34 EC\u00d3GRAFO", "description": "Se solicita a la convocante admitir transductor endocavitario  con ancho de banda de3 a 11 MHz exfov: 210. Para dar mayor participaci\u00f3n a oferentes.", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:23:27-04:00"}, {"id": "95f5b2c77f0ff9679bc93724e44cb2c5-1", "date": "2024-09-17T17:43:24-04:00", "title": "ITEM 35", "description": "En el \u00edtem 35 de las Especificaciones t\u00e9cnicas donde dice \u201cRango Din\u00e1mico de al menos 300 dB.\u201d, solicitamos a la convocante la modificaci\u00f3n de este \u00edtem por \u201cRango din\u00e1mico de al menos 280 dB\u201d, La mayor\u00eda de los procedimientos cl\u00ednicos no demandan un rango din\u00e1mico de 300 dB. y la modificaci\u00f3n de este \u00edtem a 280 dB alinea el equipo con las necesidades reales de los usuarios y las normativas vigentes", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:16:36-04:00"}, {"id": "f773decd955b3c87787623df9bf152df-1", "date": "2024-09-18T17:44:03-04:00", "title": "\u00cdtem 44 \u2013 M\u00e1quina de Anestesia", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 5.14 se solicita \u201cflujo inspiratorio m\u00e1ximo: 120LPM m\u00e1s flujo de gas fresco\u201d solicitamos a la Convocante pueda modificar este punto por \u201cflujo inspiratorio m\u00e1ximo: 180LPM m\u00e1s flujo de gas fresco\u201d de manera a adecuarse a los valores de la mayor\u00eda de las marcas presentes en el mercado y no limitar la participaci\u00f3n.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:10:05-04:00"}, {"id": "771eb5ca339788ba5f1e0bc163efc416-1", "date": "2024-09-25T14:31:42-04:00", "title": "Especificaciones Tecnicas", "description": "Item 34-  Pantalla secundaria t\u00e1ctil de 15 \u00b12\" para el manejo interactivo del men\u00fa, para acceso a modos de operaci\u00f3n aplicaciones y configuraciones. Solicitamos amablemente a la convocante aceptar pantalla secundaria de 15 \u00b15\" de manera a ampliar el rango para dar lugar de participaci\u00f3n a oferentes con mejores prestaciones, adem\u00e1s esto no desvia sustancialmente las prestaciones del equipo.", "answer": "Respondido en la Consulta 49.", "dateAnswered": "2024-09-26T14:24:12-04:00"}, {"id": "9c58b19e7bbde240d815abe3a584b2ff-1", "date": "2024-09-17T17:43:00-04:00", "title": "ITEM 35", "description": "En el \u00edtem 35 de las Especificaciones t\u00e9cnicas donde dice \u201cPanel de control retroiluminado y pantalla t\u00e1ctil integrado a la consola del equipo para acceso r\u00e1pido a las principales funciones del equipo con teclado alfanum\u00e9rico\u201d solicitamos a la convocante la modificaci\u00f3n de este \u00edtem por \u201cPanel de control retroiluminado con teclado alfanum\u00e9rico\u201d, esta modificaci\u00f3n reduce la complejidad del requisito sin afectar las funciones clave, lo que ofrece mayor flexibilidad en las propuestas y ampl\u00eda la posibilidad de participaci\u00f3n de diferentes oferentes.", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:16:25-04:00"}, {"id": "1199620806c774b060592d4b65cb1bf3-1", "date": "2024-09-18T14:19:29-04:00", "title": "\u00cdtem 25 Cardiodesfibrilador", "description": "13.1 Palas externas para adultos (par). Cantidad: 1 (una) unidad por equipo m\u00e1s 2 (dos) unidades por la totalidad de los equipos.\nConsideramos que deber\u00eda decir para infantiles.\nSolicitamos excluir la cantidad extra solicitada, considerando que se pide un s\u00f3lo equipo?", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:21:47-04:00"}, {"id": "bc183fb4004cdbdc49f050dba45655e6-1", "date": "2024-09-18T17:42:55-04:00", "title": "\u00cdtem 42 \u2013 Ventilador Pulmonar de Alta Complejidad", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 6.16 se solicita \u201cVolumen de fuga De 0 a 3000 ml\u201d solicitamos a la Convocante pueda modificar este punto por \u201cVolumen de fuga\u201d de manera a poder ajustarse a las tecnolog\u00edas disponibles en el mercado ya que varias marcas configuran este par\u00e1metro en porcentaje y no en ml, con esta modificaci\u00f3n se estar\u00eda posibilitando la participaci\u00f3n de m\u00e1s oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:33:40-04:00"}, {"id": "fbc77678f281878502a81cd383a8a7d1-1", "date": "2024-09-18T17:52:11-04:00", "title": "\u00cdTEM 35 EC\u00d3GRAFO", "description": "4.10 Se solicita a la convocante admitir  al menos 1032192 de canales digitales de procesamiento, para dar mayor participaci\u00f3n a oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:11:28-04:00"}, {"id": "9cfc79b84712ac20c2177b61b259cf4c-1", "date": "2024-09-18T22:31:52-04:00", "title": "ID 443857 - \u00cdtem 34 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Elaxtosonograf\u00eda por Strain con representaci\u00f3n de histograma en el ROI, compatible para uso con transductores convexo, lineal y endocavitario\" solicitamos a la convocante considerar este punto como OPCIONAL, debido a que esta caracter\u00edstica encarece significativamente el precio referencial del ec\u00f3grafo requerido.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:34:53-04:00"}, {"id": "ba5103b3cdf24d2e8138127f5da53328-1", "date": "2024-09-17T17:42:34-04:00", "title": "ITEM 34", "description": "En el \u00edtem 34 de las Especificaciones t\u00e9cnicas donde dice \u201cImagen trapezoidal hasta 70cm \u00b1 10 cm (funcionalidad para transductores lineales)\u201d, solicitamos a la convocante la modificaci\u00f3n de este \u00edtem por \u201cImagen trapezoidal hasta 30 cm \u00b110 cm (funcionalidad para transductores lineales)\u201d, este rango es m\u00e1s realista y est\u00e1 dentro de los est\u00e1ndares de los equipos disponibles, garantizando mayor flexibilidad en las ofertas sin comprometer la funcionalidad del equipo", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:16:09-04:00"}, {"id": "d39fb461a730e7c258b5540b7d913b77-1", "date": "2024-09-18T18:52:43-04:00", "title": "Item 53 \u2013 Monitor multiparam\u00e9trico", "description": "En  el punto 53 3.2  Normas de calidad generales: ISO 13485. Dicho documento debe estar vigente e indicar marca y modelo ofertado, se\u00f1alamos que al tratarse de un certificado de f\u00e1brica y no de producto en particular por lo general no se mencionan los modelos, por lo que deber\u00edan solicitar marca y tipo de equipo ofertado.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:15:30-04:00"}, {"id": "7185664a8022cf1e5b1419f62a1d3923-1", "date": "2024-09-18T22:26:33-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Donde dice \"Transductor sectorial o phased array de cristal \u00fanico para paciente adulto con ancho de banda de 1 MHz o menor a 5 MHz o mayor.Con Campo de apertura de almenos 90\u00b0. Que alcance una profundidad de escaneo de al menos 35cm o mayor. Cantidad: 01 unidad\" solicitamos a la convocante modificar este punto a \"Transductor sectorial o phased array de cristal \u00fanico para paciente adulto con ancho de banda de 1.5 MHz o menor a 4 MHz o mayor.Con Campo de apertura de almenos 90\u00b0. Que alcance una profundidad de escaneo de al menos 30cm o mayor. Cantidad: 01 unidad\" dichos par\u00e1metros son est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos que modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:29:07-04:00"}, {"id": "8fff8ed90f0d93c9882e5481d638ae70-1", "date": "2024-09-18T18:51:18-04:00", "title": "Item 16 \u2013 Monitor multiparam\u00e9trico", "description": "En los puntos 16 6 EEG 16 6.1 Con al menos 8 canales de EEG  16 6.2 Verificaci\u00f3n autom\u00e1tica de impedancia y reconocimiento de conjuntos de cables 16 6.3 Posibilidad de mediciones de referencia o bipolares 16 6.4 Frecuencia de muestreo 100 Hz por canal Rango \u00b1 400 \u03bcV, 16 7.7 (dos) sistemas EEG de 8 canales por la totalidad de equipos. solicitamos se puedan cotizar m\u00f3dulos de EEG de 4 canales que son suficientes para fines de monitoreo y que adem\u00e1s un m\u00f3dulo de EEG de 8 canales corresponde nuevamente a la marca NIHON KOHDEN demostrando que las especificaciones t\u00e9cnicas est\u00e1n completamente dirigidas.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:13:56-04:00"}, {"id": "416b03296cb5870848adc68ea0adfbaf-1", "date": "2024-09-18T22:36:29-04:00", "title": "\u00cdtem 38 \u2013 Equipo de Rayos X M\u00f3vil", "description": "Donde dice \"Resoluci\u00f3n espacial de 3,5 PL/mm o mejor\" solicitamos a la convocante modificar este punto a \"Resoluci\u00f3n espacial de 3,3 PL/mm o mejor\" La diferencia solicitada es m\u00ednima, adem\u00e1s, dicho par\u00e1metro es est\u00e1ndar en la mayor\u00eda de los equipos de rayos x m\u00f3vil y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos se actualice este punto a fin de tener la participaci\u00f3n de las marcas con reconocida representaci\u00f3n y comprobada calidad en el mercado local e internacional. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 38 est\u00e1n direccionadas a la marca SHIMADZU modelo MobileArt Eco MUX-10, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:35:39-04:00"}, {"id": "b93aae3c192955188d6b8289e1db0e95-1", "date": "2024-09-18T22:03:01-04:00", "title": "Item 42 Ventilador Pulmonar", "description": "En el punto 6.28 dice \u201cHerramienta cl\u00ednica para titulaci\u00f3n de PEEP\u201d solicitamos considerar esta caracter\u00edstica como opcional considerando que es una caracter\u00edstica exclusiva de la marca NIHON KOHDEN, representada por la empresa la casa del m\u00e9dico", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:00-04:00"}, {"id": "fbbff93e29f662fe8cf3fa9b3135f82b-1", "date": "2024-09-17T17:42:29-04:00", "title": "ITEM 34", "description": "En el \u00edtem 34 de las Especificaciones t\u00e9cnicas donde dice \u201cImagen trapezoidal hasta 70cm \u00b1 10 cm (funcionalidad para transductores lineales)\u201d, solicitamos a la convocante la modificaci\u00f3n de este \u00edtem por \u201cImagen trapezoidal hasta 30 cm \u00b110 cm (funcionalidad para transductores lineales)\u201d, este rango es m\u00e1s realista y est\u00e1 dentro de los est\u00e1ndares de los equipos disponibles, garantizando mayor flexibilidad en las ofertas sin comprometer la funcionalidad del equipo", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:16:06-04:00"}, {"id": "1f09c074a01cfd57b1b1300d1c7185c1-1", "date": "2024-09-18T22:02:48-04:00", "title": "Item 42 Ventilador Pulmonar", "description": "En el punto 6.16 dice \u201cVolumen de fuga De 0 a 3000 ml\u201d solicitamos a la convocante permita cotizar equipos que desplieguen este par\u00e1metro en funci\u00f3n de la fuga de acuerdo a lo que va entregando por ejemplo 5 a 95%, y as\u00ed dar participaci\u00f3n a potenciales oferentes", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:27:48-04:00"}, {"id": "4ef78db52a5b63cbf361470b07ec6461-1", "date": "2024-09-19T06:56:33-04:00", "title": "item 42", "description": "Solicitan Pantalla LCD de 19 \u00b1 2\" Perilla o botones selectores para ajuste de valores. Solicitamos diga Pantalla LCD de al menos 15\u201d con Perilla o botones selectores para ajuste de valores.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:37:08-04:00"}, {"id": "ecbf3becb614631e65f6d2d162ac1966-1", "date": "2024-09-18T18:51:14-04:00", "title": "Item 16 \u2013 Monitor multiparam\u00e9trico", "description": "Punto 16 4.6.3 Medici\u00f3n de variaci\u00f3n de presi\u00f3n sist\u00f3lica (VPS), variaci\u00f3n de presi\u00f3n\nde pulso (VPP), presi\u00f3n de perfusi\u00f3n cerebral (PPC), medici\u00f3n de la presi\u00f3n venosa central al final de la expiraci\u00f3n (PVC-ET). Solicitamos que la PPC, VPS y PVC-ET sean opcionales puesto que esos valores son obtenidos con distintos r\u00f3tulos.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:13:53-04:00"}, {"id": "1bafb5e86b2d1358282a9d4ab202889e-1", "date": "2024-09-18T21:02:53-04:00", "title": "\u00cdtem 37: Equipo para tratamiento de hemodi\u00e1lisis", "description": "El PBC solicita Bicarbonato: 1 a 8 mS/cm.Se solicita amablemente a la convocante que, de manera a permitir la competencia de marcas de gran reconocimiento a nivel mundial y experiencia comprobada en el mercado local, sean aceptados equipos con Bicarbonato: 1 a 8 mS/cm o \u00b18 mmol/l, a fin de brindar mayor oportunidad de participacion de los oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:27:00-04:00"}, {"id": "c2b6721f7c7de758fedded1c0da94145-1", "date": "2024-09-18T18:51:30-04:00", "title": "Item 24 \u2013 Cardiodesfibrilador", "description": "Donde dice: 24 5.2 Energ\u00eda seleccionable por pasos, modo bif\u00e1sico. Limite inferior: 1 Joules \u00b1 1 J. L\u00edmite superior: 270 Joules o m\u00e1s. Solicitamos se revise esta especificaci\u00f3n puesto que en la tecnolog\u00eda bif\u00e1sica no se proporciona al paciente m\u00e1s de 200 J-", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:14:12-04:00"}, {"id": "26d6d6b28a0922334bd7d31cc40b7606-1", "date": "2024-09-18T19:20:35-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 34. Punto 7.2", "description": "\u201cTransductor Convexo con un ancho de banda de 1 MHz o menor a 5 MHz o mayor. Con profundidad de escaneo hasta 44 cm o mayor. Compatible para uso de elastosonograf\u00eda. Cantidad: 01 (Uno) por cada equipo\u201dSolicitamos a la convocante que considere ajustar la especificaci\u00f3n de \"Profundidad de escaneo hasta 44 cm o mayor\" a un rango de 35 \u00b13 cm. Un rango de 35 cm proporciona una profundidad adecuada para la mayor\u00eda de las aplicaciones cl\u00ednicas, y es compatible con las capacidades t\u00edpicas de transductores convencionales. Este ajuste permitir\u00e1 una mayor flexibilidad en la selecci\u00f3n de equipos sin comprometer la funcionalidad necesaria para realizar elastosonograf\u00eda. Adem\u00e1s, ayudar\u00e1 a equilibrar los requisitos con los costos de los equipos, promoviendo una competencia m\u00e1s amplia y equitativa entre los proveedores.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:17:04-04:00"}, {"id": "8d9b7e711f60e3fc96675bc8c90bd2e3-1", "date": "2024-09-18T17:43:04-04:00", "title": "\u00cdtem 42 \u2013 Ventilador Pulmonar de Alta Complejidad", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 6.25 se solicita \u201cCapacidad de almacenar 10.000 eventos, relacionados con los par\u00e1metros ventilatorios\u201d solicitamos a la Convocante pueda modificar este punto por \u201cCapacidad de almacenar 5.000 eventos o m\u00e1s, relacionados con los par\u00e1metros ventilatorios\u201d de manera a ajustarse a los valores normales de este par\u00e1metro y no limitar los mismos. Esta modificaci\u00f3n permite la participaci\u00f3n de m\u00e1s oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:33:58-04:00"}, {"id": "5e7cf186534c11a541edd8cfe0f24b6a-1", "date": "2024-09-18T22:27:00-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Donde dice \"Transductor sectorial transesof\u00e1gico multiplanar con frecuencia de 3Mhz o menor a 8MHz o mayor. Cantidad: 01 unidad\" solicitamos a la convocante modificar este punto a \"Transductor sectorial transesof\u00e1gico multiplanar con frecuencia de 3.5Mhz o menor a 9MHz o mayor. Cantidad: 01 unidad\" dichos par\u00e1metros son est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos que modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:29:12-04:00"}, {"id": "f2c71c0835305b310a888d1a7ee874e1-1", "date": "2024-09-18T17:40:50-04:00", "title": "\u00cdtem 37: Equipo para tratamiento de hemodi\u00e1lisis", "description": "El PBC solicita Di\u00e1lisis con Bicarbonato l\u00edquido y Cartucho de Bicarbonato en Polvo. Se solicita amablemente a la convocante que, de manera a permitir la competencia de marcas de gran reconocimiento a nivel mundial y experiencia comprobada en el mercado local, y sin ir en detrimento de lo solicitado, y atendiendo a que la presentaci\u00f3n del concentrado de bicarbonato en polvo sea un par\u00e1metro excluyente, planteamos la siguiente reformulaci\u00f3n del requisito Di\u00e1lisis con Bicarbonato l\u00edquido y Bicarbonato en Polvo (cartucho o bolsa), a fin de brindar mayor oportunidad de participaci\u00f3n a los oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:33:15-04:00"}, {"id": "fcae885a9583c7dabf1af4fa571a1948-1", "date": "2024-09-18T22:25:30-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Donde dice \"Software para medici\u00f3n del espesor de la intima media en tiempo real\" solicitamos a la convocante considerar este punto como OPCIONAL debido a que esta caracter\u00edstica encarece significativamente el precio referencial del ecocardi\u00f3grafo requerido.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:29:02-04:00"}, {"id": "fe272c07e296147d27bceb6af9b09db1-1", "date": "2024-09-18T17:44:46-04:00", "title": "\u00cdtem 44 \u2013 M\u00e1quina de Anestesia", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 5.16 se solicita \u201cManipuleo y control por pantalla t\u00e1ctil y mando rotatorio.\u201d solicitamos a la Convocante pueda modificar este punto por \u201cManipuleo y control por pantalla t\u00e1ctil y/o mando rotatorio.\u201d De manera a ajustarse al tipo de equipo solicitado (mediana complejidad) y tambien al precio referencial unitario para este \u00edtem.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:10:12-04:00"}, {"id": "8fb056896f0ba494bc434aace36f06e9-1", "date": "2024-09-18T17:43:07-04:00", "title": "\u00cdtem 42 \u2013 Ventilador Pulmonar de Alta Complejidad", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 8.2 se solicita \u201cSuministro de gas O2 Desde 31 psi o menor hasta llegar 87 psi o mayor\u201d solicitamos a la Convocante pueda modificar este punto por \u201cSuministro de gas O2 Desde 40 psi o menor hasta llegar 87 psi o mayor\u201d de manera a ajustarse a los valores est\u00e1ndares del mercado y no limitar los mismos. Esta modificaci\u00f3n permite la participaci\u00f3n de m\u00e1s oferentes", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:34:00-04:00"}, {"id": "1970609e8a5d7cdea5b8fd873816a2e1-1", "date": "2024-09-18T17:43:43-04:00", "title": "\u00cdtem 44 \u2013 M\u00e1quina de Anestesia", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 2.8 se solicita \u201cBateria de respaldo interconstruida de grado medico con capacidad de 180 minutos \u00b1 30 min.\u201d solicitamos a la Convocante pueda modificar este punto por \u201cBateria de respaldo interconstruida de grado medico con capacidad de 120 minutos \u00b1 30 min.\u201d de manera a ajustarse a lo solicitado en el punto 5.20 del mismo \u00edtem y adecuarse a las especificaciones de las marcas disponibles en el mercado. Esto permitir\u00e1 un mayor n\u00famero de oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:34:12-04:00"}, {"id": "f07f91a7ab23f684ea91782e1ce9bfdd-1", "date": "2024-09-18T14:20:21-04:00", "title": "\u00cdtem 54 Nefroscopio", "description": "9.2 Manuales: Un (01) del usuario o de operaci\u00f3n y Un (01) manual t\u00e9cnico por equipo, que ser\u00e1n entregados en el momento de la recepci\u00f3n el equipo. Todos los manuales ser\u00e1n originales del fabricante y no fotocopias ni traducciones.\nSolicitamos excluir este requisito, teniendo en cuenta que no se trata de un equipo", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:22:53-04:00"}, {"id": "480eb537003bb0a345087246b70a7312-1", "date": "2024-09-18T14:19:59-04:00", "title": "\u00cdtem 32 Citoscopio", "description": "4.2 210\u00ba abajo\n\u00bfSe podr\u00eda considerar de 140\u00ba a 210\u00ba?", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:22:43-04:00"}, {"id": "918097a94735bfd15ce02ea197dc7695-1", "date": "2024-09-25T14:32:06-04:00", "title": "\u00cdtem 1_ Aspirador de secreciones", "description": "En el punto 2.9 de las especificaciones t\u00e9cnicas la Convocante solicita:\nEl equipo permitir\u00e1 el acople de 2 frascos recolectores, de 5 litros cada una, totalizando en su m\u00e1xima capacidad hasta 10 litros;\nSolicitamos respetuosamente a la Convocante permitir la cotizaci\u00f3n de equipos con:\nEl equipo permitir\u00e1 el acople de 2 frascos recolectores, de 3 litros cada una como m\u00ednimo, totalizando capacidad 6 litros como m\u00ednimo;", "answer": "Respondido en la Consulta 150.", "dateAnswered": "2024-09-26T14:24:14-04:00"}, {"id": "8301409c972e710f9fd5f8a41a51ca63-1", "date": "2024-09-18T18:50:59-04:00", "title": "Item 14 \u2013 Caja de cirug\u00eda general", "description": "Donde solicitan: Certificaci\u00f3n de la calidad de los instrum\u00e9ntales: DIM EN 10088T.1-3, EN ISO 7153-1 , y EN ISO 13485:2016, por favor aclarar que se requiere alguno de ellos", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:13:40-04:00"}, {"id": "8cba0541551248a017e214869e0cdad8-1", "date": "2024-09-23T14:57:14-04:00", "title": "ANTICIPO", "description": "En punto donde menciona lo siguiente: Para acceder al anticipo, la empresa adjudicada deber\u00e1 presentar dentro de los 10 d\u00edas calendarios siguientes a la firma del contrato las documentaciones.\nAl respecto consultamos cual ser\u00eda el plazo m\u00e1ximo para el cobro de anticipo?. Esta consulta es realizada en base que la solicitud de anticipo seg\u00fan el PBC debe realizarse a los 10 dias de calendarios de la firma del contrato y el plan de entrega establece que el bien adjudicado debe ser entregado  el 100 % dentro de los 30 dias a partir de la firma del contrato.", "answer": "La convocante realiza las gestiones para el pago de anticipo, de acuerdo a la disponibilidad del MEF.", "dateAnswered": "2024-09-26T14:23:53-04:00"}, {"id": "1fea51a22f290f5e06a381e2c5eaef78-1", "date": "2024-09-18T18:52:56-04:00", "title": "Item 53 \u2013 Monitor multiparam\u00e9trico", "description": "Punto 16 4.6.3 Medici\u00f3n de variaci\u00f3n de presi\u00f3n sist\u00f3lica (VPS), variaci\u00f3n de presi\u00f3n\nde pulso (VPP), presi\u00f3n de perfusi\u00f3n cerebral (PPC), medici\u00f3n de la presi\u00f3n venosa central al final de la expiraci\u00f3n (PVC-ET). Solicitamos que la PPC, VPS y PVC-ET sean opcionales puesto que esos valores son obtenidos con distintos r\u00f3tulos.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:15:47-04:00"}, {"id": "1ee1f07262a3b378e993d1d14ca30504-1", "date": "2024-09-18T22:38:12-04:00", "title": "ID 443857 - \u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \u201cControl de compensaci\u00f3n de la ganancia TGC de 8 controles como m\u00ednimo\u201d solicitamos a la convocante modificar este punto a \u201cControl de compensaci\u00f3n de la ganancia TGC de 6 controles como m\u00ednimo.\u201d Lo solicitado se fundamenta en que los ec\u00f3grafos con comprobada calidad cuentan con otros sistemas adicionales de mejoramiento de la ganancia de imagen, aparte del TGC, como la optimizaci\u00f3n autom\u00e1tica de ganancia, que ajusta din\u00e1micamente la ganancia de acuerdo a la profundidad del estudio, lo cual permite obtener la calidad de imagen m\u00e1s optimizada en las diferentes profundidades del estudio. Por lo que solicitamos modificar este punto a fin de permitir la participaci\u00f3n de potenciales oferentes con reconocida representaci\u00f3n y comprobada calidad en el mercado local e internacional. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:05-04:00"}, {"id": "ef52df54bc77de5a6c8a9692f1a5ab90-1", "date": "2024-09-18T18:50:55-04:00", "title": "Item 11 \u2013 Caja de cirug\u00eda especializada", "description": "En el punto 11.2.14 1 PAR SEPARADOR FARABEUF O SEPARADOR US ARMY, de 21 a 22 cm de longitud, solicitamos de pueda cotizar 1 PAR SEPARADOR PARKER-LANGENBERG de 21 a 22 cm de longitud, considerando que cumplen la misma funci\u00f3n.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:13:38-04:00"}, {"id": "1e8e3f8d73c85d1ea9f8fa8446a68309-1", "date": "2024-09-18T13:03:41-04:00", "title": "Especificaciones T\u00e9cnicas - ITEM 51 Microscopio de fluorescencia", "description": "Donde dice \u201cCapacitaci\u00f3n a usuarios sobre el funcionamiento del equipo y capacitaci\u00f3n t\u00e9cnica al personal t\u00e9cnico del departamento de electromedicina. Presentar declaraci\u00f3n jurada.\u201d \n\nSolicitamos a la convocante tener en cuenta que, las capacitaciones que pueden ser ofrecidas a los clientes son de funcionamiento y cuidados para el equipo, debido a que las capacitaciones t\u00e9cnicas son brindadas exclusivamente para los t\u00e9cnicos de la empresa quienes representan a la marca", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:19:26-04:00"}, {"id": "8769f754570e7051f026cbbee42e070d-1", "date": "2024-09-18T14:20:04-04:00", "title": "\u00cdtem 41 L\u00e1mpara cial\u00edtica con sat\u00e9lite", "description": "Solicitamos excluir los requisitos enumerados en la p\u00e1gina 104, numerales: 1.3.7, 1.3.8, 1.3.9, 1.3.10, 1.3.11, 1.3.13, 1.3.14, 1.4, 1.4.1 al 1.4.6, 1.5, 4.1, 4.2, 4.3, 4.4. Estos no son especificaciones o accesorios del equipo solicitado", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:22:46-04:00"}, {"id": "f4cd01bac3daedfdd37f7ba626a70173-1", "date": "2024-09-18T22:39:50-04:00", "title": "\u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Bater\u00eda interna con autonom\u00eda de al menos 90 minutos\" solicitamos a la convocante modificar este punto a \u201cBater\u00eda interna con autonom\u00eda de al menos 60 minutos o mejor\u201d lo solicitado no afecta al estudio ni a la calidad de imagen, adem\u00e1s, dicho par\u00e1metro es est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda, por lo que solicitamos se actualice este punto a fin de tener la participaci\u00f3n de las marcas con reconocida representaci\u00f3n y comprobada calidad en el mercado local e internacional. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:17-04:00"}, {"id": "0b58804774afc68347cfde821bbfc776-1", "date": "2024-09-18T17:43:51-04:00", "title": "\u00cdtem 44 \u2013 M\u00e1quina de Anestesia", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 5.3 se solicita \u201cCon medici\u00f3n y aplicaci\u00f3n de los par\u00e1metros respiratorios en pantalla LCD o LED color de 19 pulgadas \u00b1 2\"\u201d solicitamos a la Convocante pueda modificar este punto por \u201cPantalla LCD de 17 \u00b1 2\" Con medici\u00f3n y aplicaci\u00f3n de los par\u00e1metros respiratorios en pantalla LCD o LED color de 14 pulgadas \u00b1 2\"\u201d de manera a ajustarse a los valores est\u00e1ndares del mercado y no limitar los mismos. La modificaci\u00f3n sugerida no afecta en lo m\u00e1s m\u00ednimo la funcionalidad del equipo. Esta modificaci\u00f3n permite la participaci\u00f3n de m\u00e1s oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:10:00-04:00"}, {"id": "ba617c20a4c3efa9f617ebf9b9ca8a70-1", "date": "2024-09-17T17:33:48-04:00", "title": "ITEM 34", "description": "En el \u00edtem 34 de las Especificaciones t\u00e9cnicas donde dice \u201cSoftware para detecci\u00f3n de translucencia intracraneal\u201d, solicitamos a la convocante poner como opcional este requerimiento permite que los proveedores presenten ofertas con equipos m\u00e1s accesibles en cuanto a costo, lo que puede aumentar la cantidad de oferentes y mejorar la competencia, esto es especialmente", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:15:52-04:00"}, {"id": "2cac75501413640a94c2e4afd2eb6198-1", "date": "2024-09-18T19:15:25-04:00", "title": "item 26 carro de paro", "description": "En el Item 26 Carro de Paro, en el punto 4.1 Solicitan Estructura en pol\u00edmero de alta densidad, con tablero de ABS y barandilla en acero inoxidable AISI 304., Solicitamos al oferente poder cotizar con estructura en acero de alta resistencia acabado en frio, de esta manera se tendr\u00e1 con mayor participaci\u00f3n a los oferentes ya que el \u00fanico que re\u00fane dichas capacitaciones es la empresa LCM con su marca Saikang", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:16:53-04:00"}, {"id": "65e871632c8b0771c67aed78f79a9004-1", "date": "2024-09-18T19:31:10-04:00", "title": "ITEM 38 \u2013 Equipo de rayos x portatil", "description": "En el punto 6.12 donde dice \u201cCapacidad de hasta 2.500 im\u00e1genes con las bater\u00edas cargadas a raz\u00f3n de 1 imagen cada 15 segundos o mejor.\u201d Solicitamos amablemente a la convocante permita cotizar equipos con capacidad de hasta 1000 im\u00e1genes a plena carga, esto para dar apertura a las especificaciones t\u00e9cnicas para la participaci\u00f3n de potenciales oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:18:11-04:00"}, {"id": "bd0cc188f294a55d4e68ff8fe0749f22-1", "date": "2024-09-18T18:50:46-04:00", "title": "Item 10 \u2013 Caja de cirug\u00eda especializada", "description": "En el punto 10.2.3 1 SEPARADOR GOSSET CORTO O SEPARADOR BALFOUR, de 25 a 30 cm, solicitamos se pueda cotizar 1  SEPARADOR BALFOUR, de 20 cm que se trata de una medida est\u00e1ndar para este instumental.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:13:21-04:00"}, {"id": "e9bea94f639b293784cd64fbb19bdb09-1", "date": "2024-09-18T18:50:43-04:00", "title": "Item 9 \u2013 Caja de cirug\u00eda menor", "description": "En el punto 9 2.1 1 EVACUADOR FEMENINO 155MM 8,10,12,14FR, por favor aclarar si se refieren a sondas urinarias descartables.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:13:17-04:00"}, {"id": "c7c31fa7ea96620c36acae197085b4bc-1", "date": "2024-09-18T14:52:32-04:00", "title": "Requisitos Documentales", "description": "En la Pg. 20 del PBC, Requisitos documentales para evaluar el criterio de capacidad t\u00e9cnica, \u00edtem 12 establece que: \u201cDeclaraci\u00f3n jurada de que la empresa adjudicada se compromete a:\n-Incluir mantenimientos preventivos y asistencia t\u00e9cnica a demanda por un a\u00f1o.\n-Que los mantenimientos se realizaran seg\u00fan los est\u00e1ndares de la marca y del equipo ofertado, presentar copia el protocolo de mantenimiento.\n-Que proveer\u00e1 Asistencia t\u00e9cnica seg\u00fan necesidad, sea mantenimiento preventivo o correctivo, en un periodo menor a 48 hs., stock de repuestos y accesorios originales de f\u00e1brica\u201d\nSolicitamos respetuosamente a la convocante definir si el mantenimiento correctivo deber\u00e1 ser con provisi\u00f3n de repuestos, en el caso de que sea afirmativo, tambien detallar que los mantenimientos correctivos solo sean cubiertos por defectos de F\u00e1brica, no as\u00ed por problemas ocasionados por mala utilizaci\u00f3n por parte del operario y da\u00f1os por factores externos (sistema de agua tratada, alimentaci\u00f3n el\u00e9ctrica, entre otros).\nAs\u00ed tambien definir si los mantenimientos preventivos y asistencia t\u00e9cnica a demanda deber\u00e1n ser por un a\u00f1o o por dos a\u00f1os, como se solicita en el apartado de garant\u00eda del \u00edtem 37.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:24:04-04:00"}, {"id": "27a2dae1494e23cc0bbb1ad76678ee7d-1", "date": "2024-09-18T20:55:54-04:00", "title": "\u00cdtem 37: Equipo para tratamiento de hemodi\u00e1lisis", "description": "El PBC solicita Puerto de conexi\u00f3n a computadora para visualizar los par\u00e1metros del tratamiento.Se solicita amablemente a la convocante que, de manera a permitir la competencia de marcas de gran reconocimiento a nivel mundial y experiencia comprobada en el mercado local, por lo que planteamos la siguiente reformulacion del requisito Puerto de conexi\u00f3n a computadora para visualizar los par\u00e1metros del tratamiento (opcional), a fin de brindar mayor oportunidad de participacion a los oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:26:52-04:00"}, {"id": "a1c55ff0f89cec18f6afab868ea07e24-1", "date": "2024-09-18T22:40:46-04:00", "title": "\u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Software que amplia virtualmente el campo de visi\u00f3n en los transductores cardiol\u00f3gicos en la punta para una mejor evaluaci\u00f3n del VI para an\u00e1lisis de STRAIN\" solicitamos a la convocante considerar este punto como OPCIONAL. Lo solicitado obedece a que este software corresponde a equipos de la Marca (GE), por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:19-04:00"}, {"id": "fa2dac1270c0ed3b61d2c2a334b5b937-1", "date": "2024-09-23T14:57:51-04:00", "title": "CAPACITACION", "description": "ITEM 35 En el punto 3.4 Capacitaci\u00f3n a usuarios sobre el funcionamiento del equipo y capacitaci\u00f3n t\u00e9cnica al personal t\u00e9cnico del Departamento de Electromedicina. Presentar declaraci\u00f3n jurada.\nSe solicita amablemente a la convocante especificar la cantidad de horas necesarias para realizar el entrenamiento. Sin embargo, se sugiere que para cumplir con dicho punto es m\u00e1s que suficiente 8 horas por 2 d\u00edas y de esta manera cubrir con todos los puntos que pueden realizar los usuarios.", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:24:05-04:00"}, {"id": "9f133ec47db7c68c54b0b3aa37b073e0-1", "date": "2024-09-13T12:15:19-04:00", "title": "Especificaciones t\u00e9cnicas. \u00cdtem 40 ESTUFA DE SECADO", "description": "\u00cdtem 40 estufa de secado: El PBC especifica Estabilidad +- 0,4 \u00baC.\nFavor indicar si la estabilidad se refiere a la precisi\u00f3n del equipo", "answer": "Afirmativo.", "dateAnswered": "2024-09-26T07:09:11-04:00"}, {"id": "f8cca972cd7491d28defaaeb0321a21b-1", "date": "2024-09-18T11:20:28-04:00", "title": "Cajas de Cirug\u00eda", "description": "Para todos los \u00edtems de Cajas de Cirug\u00eda en donde menciona el punto:  Se aceptar\u00e1 una variaci\u00f3n de 2+/-cm en las medidas de los instrumentales.\n\u00bfFavor aclarar si es m\u00e1s menos 2 cm sobre las \u00faltimas medidas de las especificaciones? \nEjemplo de 12 a 14 cm ser\u00e1 desde 10 cm hasta 16 cm?", "answer": "Remitirse al PBC, se aclara que se ha consignado en las EETT, que se aceptan variaciones, seg\u00fan se indica en los numerales.", "dateAnswered": "2024-09-26T07:18:13-04:00"}, {"id": "0888e26ba900164722510d4f4799ca16-1", "date": "2024-09-17T18:02:27-04:00", "title": "CONSULTA 5. CRONOGRAMA DE ENTREGAS", "description": "Se pide a la convocante considerar el tiempo de fabricaci\u00f3n de los equipos as\u00ed como el transporte y los tiempos de despacho necesarios para los equipos a ser importados. Se solicita al menos extender el plazo de entrega a 90 d\u00edas a partir de la firma del contrato.", "answer": "Remitirse a la respuesta de la consulta 1.", "dateAnswered": "2024-09-26T07:17:36-04:00"}, {"id": "c7843dca23ee675fe702c1428875a7cb-1", "date": "2024-09-18T22:41:09-04:00", "title": "\u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Software que realiza el c\u00e1lculo de la torsi\u00f3n en los cortes transversales del eje corto a nivel de VM y AP\" solicitamos a la convocante considerar este punto como OPCIONAL debido a que esta caracter\u00edstica encarece significativamente el precio referencial del ec\u00f3grafo requerido. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:24-04:00"}, {"id": "700af989b960ab4a0c55d3ed35a91ad0-1", "date": "2024-09-18T22:34:33-04:00", "title": "\u00cdtem 38 \u2013 Equipo de Rayos X M\u00f3vil", "description": "Para el \u00edtem 38 el PBC establece que el Plan de entrega de los bienes ser\u00e1: \"El 100 % dentro de los 30 d\u00edas a partir de la firma del contrato\" Favor solicitamos a la convocante modificar este punto a \"El 100 % dentro de los 120 d\u00edas posteriores a la recepci\u00f3n de la orden de compra por parte del proveedor\".  Lo solicitado obedece en su mayor\u00eda se trata de equipos cuya fabricaci\u00f3n se realiza tras un pedido al fabricante mediante orden de compra, y que posteriormente son importados, por lo que el plazo debe indefectiblemente incluir tiempo de transporte internacional y los procesos aduaneros realizados por terceros.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:35:11-04:00"}, {"id": "f5780ce841dbcf41aff375294e1b8158-1", "date": "2024-09-18T18:51:50-04:00", "title": "Item 25 \u2013 Cardiodesfibrilador", "description": "Con respecto a la capnograf\u00eda solicitada, se aceptar\u00e1n desfibriladores del tipo sidestream y no mainstream?", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:14:21-04:00"}, {"id": "d768144d60222b49497467e698b64b54-1", "date": "2024-09-18T22:36:11-04:00", "title": "\u00cdtem 38 \u2013 Equipo de Rayos X M\u00f3vil", "description": "Donde dice \"Rango de Kilovoltios de 45 kV a 125 kV en pasos de no mayor a 3 kV\" solicitamos a la convocante modificar este punto a \"Rango de Kilovoltios de 45 kV a 125 kV o mayor, en pasos de 5 kV o menor\" lo solicitado obedece a que en equipos de \u00faltima generaci\u00f3n la regulaci\u00f3n de voltaje var\u00eda dependiendo del rango de operaci\u00f3n. Ejemplo, para trabajar con \u00f3rganos de baja densidad, donde se usan bajos rangos de kv el equipo s\u00ed permite modificar los kv en 3 pasos (de 40kv a 60kv la regulaci\u00f3n es de \u00b13Kv), Sin embargo para \u00f3rganos de alta densidad no es necesario tener una regulaci\u00f3n de 3 kv, pudiendo variar desde 60Kv hasta 150 Kv en pasos de 3,4,5,etc. Por lo que solicitamos se actualice este punto a fin de tener la participaci\u00f3n de las marcas con reconocida representaci\u00f3n y comprobada calidad en el mercado local e internacional. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 38 est\u00e1n direccionadas a la marca SHIMADZU modelo MobileArt Eco MUX-10, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:35:26-04:00"}, {"id": "b27603c31bd96dfaa4009d9da54bb773-1", "date": "2024-09-18T22:39:17-04:00", "title": "\u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Transductor Phased Array pedi\u00e1trico con un ancho de banda de 2 a 9 Mhz. Cantidad: 1 (una) unidad por equipo\" solicitamos a la convocante modificar este punto a \"Transductor Phased Array pedi\u00e1trico con un ancho de banda de 3 Mhz o menor a 8 Mhz o mayor. Cantidad: 1 (una) unidad por equipo\" dichos par\u00e1metros son est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:10-04:00"}, {"id": "29f5c59bccb89b01809b5a927bc9a028-1", "date": "2024-09-18T22:39:43-04:00", "title": "\u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Transductor microconvexo con ancho de banda de 2Mhz a 11 Mhz. Cantidad: 1 (una) unidad por equipo\" solicitamos a la convocante modificar este punto a \"Transductor microconvexo con ancho de banda de 3.5Mhz o menor a 11 Mhz. Cantidad: 1 (una) unidad por equipo\" dichos par\u00e1metros son est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:36:15-04:00"}, {"id": "3b875e5066956494b5fc67ff0d373e7b-1", "date": "2024-09-18T17:51:38-04:00", "title": "\u00cdTEM 34 EC\u00d3GRAFO", "description": "Se solicita a la convocante admitir Magnificaci\u00f3n de im\u00e1genes (Zoom) hasta 30x, para dar mayor participaci\u00f3n a oferentes", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:10:47-04:00"}, {"id": "30fa90bfff8aa7db8408da6440d269da-1", "date": "2024-09-18T21:12:08-04:00", "title": "\u00cdtem 42: Ventilador pulmonar de alta complejidad.", "description": "El PBC solicita Volumen Corriente VT inspiratorio, VTe espiratorio, VTspon de 0 a 3500 ml, o mejor. Se solicita amablemente a la convocante permitir cotizar equipo, sin ir en detrimento de lo solicitado, y permitir la competencia de marcas con experiencia comprobada en el mercado local, por lo que planteamos la siguiente reformulacion del requisito: Volumen Corriente VT inspiratorio, VTe espiratorio, VTspon de 0 a 3000 ml, o mejor.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:27:18-04:00"}, {"id": "176724662d921508ccc5c0240b276c4a-1", "date": "2024-09-14T11:06:44-04:00", "title": "Especificaciones T\u00e9cnicas - \u00cdtem 42) Ventilador Pulmonar de Alta Complejidad", "description": "DONDE DICE:\n\n6.25 acidad de almacenar 10.000 eventos, relacionados con los par\u00e1metros ventilatorios\n6.28 Herramienta clinica para titulaci\u00f3n de PEEP.\n6.29 Herramienta clinica para evaluar reclutabilidad, a la mejor compliance.\n\n\nFavor modificar a: \n\n6.25 acidad de almacenar 10.000 eventos, relacionados con los par\u00e1metros ventilatorios (OPCIONAL)\n6.28 Herramienta clinica para titulaci\u00f3n de PEEP. (OPCIONAL)\n6.29 Herramienta clinica para evaluar reclutabilidad, a la mejor compliance. (OPCIONAL)\n\nLo solicitado es por el motivo que sokn condiciones t\u00e9cnicas no indispensables para el funcionamiento del equipo, no afecta en sus prestaciones, y con la modificaci\u00f3n se permitir\u00e1 mayor concurrencia y posibilidad de contar con mayor cantidad de ofertas y marcas ofertadas, y como consecuencia, aumentar las posibilidades de mejores condiciones de contrataci\u00f3n para la entidad, en concordancia con los principios de econom\u00eda, eficacia y eficiencia y de igualdad y libre competencia.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:14:37-04:00"}, {"id": "d20eaed38c661b937220e9e489f179f0-1", "date": "2024-09-14T11:03:23-04:00", "title": "Especificaciones T\u00e9cnicas  - \u00cdtem 16) Monitor Multiparam\u00e9trico", "description": "3.13 Capacidad de contar con Gasto Cardiaco\n\nSolicitamos que el requerimiento de capacidad para medir el gasto card\u00edaco sea aceptado a trav\u00e9s del m\u00e9todo de termodiluci\u00f3n. Este m\u00e9todo, aunque invasivo, es altamente confiable y ampliamente utilizado en entornos cl\u00ednicos cr\u00edticos debido a su precisi\u00f3n en la evaluaci\u00f3n del gasto card\u00edaco. La termodiluci\u00f3n proporciona datos exactos y confiables, esenciales para la monitorizaci\u00f3n de pacientes con condiciones cardiovasculares complejas, asegurando un diagn\u00f3stico y tratamiento m\u00e1s efectivo.", "answer": "Remitirse a la Adenda en el SICP.", "dateAnswered": "2024-09-26T07:14:08-04:00"}, {"id": "5e8fdca3bbb7ebdbe82be93c1a27e39f-1", "date": "2024-09-18T18:53:00-04:00", "title": "Item 53 \u2013 Monitor multiparam\u00e9trico", "description": "Donde dice: 53 7 EEG 53 7.1 Con al menos 8 canales de EEG 53 7.2 Verificaci\u00f3n autom\u00e1tica de impedancia y reconocimiento de conjuntos de cables 53 7.3 Posibilidad de mediciones de referencia o bipolares 53 7.4 Frecuencia de muestreo 100 Hz \u00b110% por canal Rango \u00b1 400 \u03bcV \u00b110% 53 7.5 Rango de frecuencia de 0,5 a al menos 30 Hz 53 7.6 Resoluci\u00f3n 60 nV o mejor 53 7.7 Impedancia de entrada > 8 M\u03a9 a 10 Hz 53 7.8 Nivel de ruido < 0.5 \u03bcV rms de 0,5 Hz a 30 Hz 53 7.9 CMRR > 100 dB a 50 Hz; solicitamos se puedan cotizar m\u00f3dulos de EEG de 4 canales que son suficientes para fines de monitoreo y que adem\u00e1s un m\u00f3dulo de EEG de 8 canales corresponde nuevamente a la marca NIHON KOHDEN demostrando que las especificaciones t\u00e9cnicas est\u00e1n completamente dirigidas", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:16:04-04:00"}, {"id": "62d2e7155b38bd5ed2b061963f5ceb51-1", "date": "2024-09-17T17:42:38-04:00", "title": "ITEM 34", "description": "En el \u00edtem 34 de las Especificaciones t\u00e9cnicas donde dice \u201cTransductor Convexo con un ancho de banda de 1 MHz o menor a 5 MHz o mayor. Con profundidad de escaneo hasta 44 cm o mayor. Compatible para uso de elastosonograf\u00eda. Cantidad: 01 (Uno) por cada equipo\u201d, solicitamos a la convocante la modificaci\u00f3n de este \u00edtem por \u201cTransductor Convexo con un ancho de banda de 2 MHz o menor a 6 MHz o mayor. Con profundidad de escaneo hasta 44 cm o mayor. Cantidad: 01 (Uno) por cada equipo\u201d, esta modificaci\u00f3n est\u00e1 alineada con el rango est\u00e1ndar de los transductores convexos disponibles en el mercado y permitir\u00e1 una mayor participaci\u00f3n de potenciales oferentes, beneficiando as\u00ed a la convocatoria en t\u00e9rminos de competencia y opciones.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:16:12-04:00"}, {"id": "e9c73fc2359753c97f74ef4c53005bd5-1", "date": "2024-09-23T14:57:06-04:00", "title": "Reajuste", "description": "El IPC es un \u00edndice econ\u00f3mico que mide las variaciones en los precios de un conjunto de bienes y servicios de la canasta familiar. Teniendo en cuenta la naturaleza de los bienes licitados, solicitamos considerar la f\u00f3rmula de reajuste en relaci\u00f3n a la variaci\u00f3n del d\u00f3lar y del salario m\u00ednimo; ya que estas son las variables que afectan a la estructura de costos de los bienes licitados y no el IPC. Sugerimos que la f\u00f3rmula de reajuste aplicada sea la siguiente:\nLos precios ofertados para los bienes, estar\u00e1n sujetos a Reajustes, siempre y cuando el D\u00f3lar Americano haya sufrido una variaci\u00f3n como m\u00ednimo del cinco por ciento (5%) del precio referente a la fecha de apertura de ofertas, conforme a la siguiente f\u00f3rmula:\nP= (Po x 0,8 x (Coe / Cao)) + (Po x 0,2 x (Soe / Sao))\nDonde;\nP= Precio Reajustado a la Oferta\nPo= Precio Original de la Oferta\nCoe= Tipo de cambio referencial del D\u00f3lar (BCP) correspondiente al de la fecha de la Acta de Recepci\u00f3n Definitiva.\nCao= Tipo de cambio referencial del D\u00f3lar (BCP) correspondiente al de la fecha del d\u00eda anterior al de la Apertura de Ofertas.\nSoe= Salario m\u00ednimo vigente a la fecha de la Recepci\u00f3n de Acta de Recepci\u00f3n Definitiva.\nSao= Salario m\u00ednimo vigente a la fecha de la Apertura de Ofertas.", "answer": "Ajustarse a lo solicitado en el PBC, atendiendo a los plazos, establecidos en la Resoluci\u00f3n DNCP N\u00b0 1430/2024 \"Plazos m\u00e1ximos para comunicar a la DNCP los llamados, adjudicaciones y contratos que afecten a los procesos que comprometan el PGN 2024\", en cuanto se refiere a los env\u00edos de adjudicaciones, esta convocatoria de gran envergadura, cuenta con plazos limitados para la evaluaci\u00f3n, cierre y posterior firmas de contratos, se ha tenido suficiente tiempo para las consultas respectivas, las mismas han sido adendadas en su gran mayor\u00eda por la Instituci\u00f3n.", "dateAnswered": "2024-09-26T13:53:16-04:00"}, {"id": "235704b7aaf2960ead3d2bd2c6ffa921-1", "date": "2024-09-18T19:29:43-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 35. Punto 4.9", "description": "\u201cRango din\u00e1mico del sistema de 300 dB o mejor.\u201d  Solicitamos a la convocante considerar ajustar el rango din\u00e1mico del sistema a un m\u00ednimo de 260 dB o m\u00e1s. El rango din\u00e1mico de 300 dB puede ser excesivo y no necesariamente representa una mejora significativa en la calidad de la imagen para todos los escenarios cl\u00ednicos, adem\u00e1s de que puede resultar en un costo m\u00e1s alto del equipo. Un rango din\u00e1mico de 260 dB sigue ofreciendo una calidad de imagen excelente mientras que permite una mayor flexibilidad en la selecci\u00f3n de equipos.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:17:20-04:00"}, {"id": "d35284ff1e392beb16441b484917613d-1", "date": "2024-09-18T22:02:26-04:00", "title": "Item 42 Ventilador Pulmonar", "description": "En el punto 4.11 donde dice \u201cFrecuencia respiratoria (bpm). L\u00edmite inferior 1 o menor y l\u00edmite superior 150 o mayor\u201d solicitamos a la convocante permita la cotizacion de equipos con rango de l\u00edmite superior de 50 o mayor, esto considerando que es el valor usual para aplicaciones Clinicas y asi tambien para dar participaci\u00f3n de potenciales oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:27:38-04:00"}, {"id": "411bff5462ede4fc48eec92cc723c517-1", "date": "2024-09-18T17:44:53-04:00", "title": "\u00cdtem 45 \u2013 M\u00e1quina de Anestesia", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 4.5 se solicita \u201cV\u00e1lvula de sobrepresi\u00f3n (ALP) DE 0 a 70 cm de H2O\u201d solicitamos a la Convocante pueda modificar este punto por \u201cV\u00e1lvula de sobrepresi\u00f3n (ALP) DE 5 cm de H2O o menor a 70 cm de H2O o mayor\u201d de manera a adecuarse a los valores de la mayor\u00eda de las marcas presentes en el mercado y no limitar la participaci\u00f3n.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:10:29-04:00"}, {"id": "68c52d07dd1d594c73988b741663e5b7-1", "date": "2024-09-18T19:27:26-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 35. Punto 4.3", "description": "\u201cMovimiento rotativo del monitor para facilitar la operaci\u00f3n del usuario\u201d Solicitamos a la convocante considerar la eliminaci\u00f3n del requisito de \"Movimiento rotativo del monitor para facilitar la operaci\u00f3n del usuario\". Esta especificaci\u00f3n est\u00e1 particularmente dirigida a ciertos modelos espec\u00edficos y no es una caracter\u00edstica com\u00fan en la mayor\u00eda de los ec\u00f3grafos port\u00e1tiles. La mayor\u00eda de los equipos en esta categor\u00eda no cuentan con esta funci\u00f3n, por lo que su inclusi\u00f3n puede limitar innecesariamente las opciones disponibles para los ofertantes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:17:17-04:00"}, {"id": "7ff6df43bfcf6463de75a7ea4ef4ec9d-1", "date": "2024-09-18T22:26:43-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Donde dice \"Transductor sectorial o phased array pedi\u00e1trico con ancho de banda de 2 MHz o menor a 9 MHz o mayor. Cantidad: 01 unidad\" solicitamos a la convocante modificar este punto a \"Transductor sectorial o phased array pedi\u00e1trico con ancho de banda de 3 MHz o menor a 8 MHz o mayor. Cantidad: 01 unidad.\" dichos par\u00e1metros son est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos que modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:29:10-04:00"}, {"id": "a99292a3fe5e936edd6b1b629f020bb9-1", "date": "2024-09-23T14:57:24-04:00", "title": "SOPORTE TECNICO", "description": "ITEM 38 En el punto 8.6 Soporte t\u00e9cnico durante el tiempo de duraci\u00f3n de la garant\u00eda.\nSolicitamos a la convocante pueda ser modificada este criterio de la siguiente manera: Soporte t\u00e9cnico durante el tiempo de duraci\u00f3n de la garant\u00eda del bien ofertado.  Presentar declaraci\u00f3n jurada.", "answer": "Respondido en la Consulta 405.", "dateAnswered": "2024-09-26T14:23:58-04:00"}, {"id": "bf6fde4f9c10f0bfbde6e929ca13890a-1", "date": "2024-09-18T22:02:32-04:00", "title": "Item 42 Ventilador Pulmonar", "description": "En el punto 5.7 donde dice \u201cTerapia O2 de bajo y alto flujo o Terap\u00eda de O2 o similar con rango (l/min) de 1 a 65 \u00b1 5 l/min\u201d solicitamos permitan cotizar equipo con rango de 0 a 50 l/min para terapia de O2 de bajo y alto flujo o terapia de O2. Y asi dar apertura a las especificaciones t\u00e9cnicas.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:27:40-04:00"}, {"id": "d3f2b755f9962508c82e68ad5d39e940-1", "date": "2024-09-18T23:14:34-04:00", "title": "Item 35 - Ecografo", "description": "Donde dice \"Software para medici\u00f3n autom\u00e1tica de la fracci\u00f3n de eyecci\u00f3n en modo 2D con reconocimiento automatico\" solicitamos a la convocante considerar este punto como OPCIONAL debido a que esta caracter\u00edstica encarece significativamente el precio referencial del ec\u00f3grafo requerido. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:53-04:00"}, {"id": "cf158521c0e886c9be9b39c4fa162fc0-1", "date": "2024-09-18T22:07:56-04:00", "title": "ITEM 44 \u2013 MAQUINA DE ANESTESIA", "description": "En el punto 2.7 donde dice \u201cPrueba inicial autom\u00e1tica para revisi\u00f3n del sistema, mezclador electr\u00f3nico, ventilador y fugas/compliance/resistencia del circuito de paciente\u201d solicitamos a la convocante que la compliance y resistencia del circuito paciente sea opcional, considerando que de esta manera se da apertura a las especificaciones t\u00e9cnicas para la participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:05-04:00"}, {"id": "4816fca796b4edfa9a012db2af6f8817-1", "date": "2024-09-17T18:02:10-04:00", "title": "CONSULTA 1. ITEM 20 \u2013 CAMA EL\u00c9CTRICA PARA PACIENTE.", "description": "En donde dice: \u201c4.4 Dimensiones de la superficie para el paciente. Longitud m\u00ednima: 190 cm +/-5 cm. Ancho m\u00ednimo 80 cm +/- 5cm.\u201d \nSe solicita amablemente a la convocante abrir este punto para permitir mayor participaci\u00f3n ya que la modificaci\u00f3n de este punto no alterar\u00e1 el inter\u00e9s original, sino que permitir\u00e1 mayor competencia. Por tanto, se solicita incrementar la longitud m\u00ednima en 5cm y el ancho m\u00ednimo en 5 cm de modo que el punto quede de la siguiente manera: \u201c4.4 Dimensiones de la superficie para el paciente. Longitud m\u00ednima: 195 cm +/-5 cm. Ancho m\u00ednimo 85 cm +/- 5cm\u201d", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:17:14-04:00"}, {"id": "7e739781ff16cccc2ee8c0fa9ab21b63-1", "date": "2024-09-19T06:56:27-04:00", "title": "item 42", "description": "Solicitan 6.25 Capacidad de almacenar 10.000 eventos, relacionados con los  par\u00e1metros ventilatorios, solicitamos permita ofertar Capacidad de almacenar al menos 1000 eventos, relacionados con los par\u00e1metros ventilatorios", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:37:05-04:00"}, {"id": "bdb4f30eed93350a787680a0df33829f-1", "date": "2024-09-18T16:33:00-04:00", "title": "item Monitor Cardiofeta", "description": "Punto 2.11 Donde dice Rango de medici\u00f3n 0-100 unidades solicitamos permita ofertar de 0-99 unidadess, solicitamos diga: Rango de medici\u00f3n 0-100 unidades solicitamos permita ofertar de 0-99 unidadess,", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:27:51-04:00"}, {"id": "09ec3793d3ebf59acada14cb68b7c199-1", "date": "2024-09-25T17:26:04-04:00", "title": "ESPECIFICACIONES TECNICAS - ITEM 21. 4.3.1", "description": "Donde se solicita\"Longitud m\u00e1xima 230 cm \u00b1 5 cm.\" Solicitamos a la convocante considerar ajustar la especificaci\u00f3n de longitud m\u00e1xima de la cama a 220 cm \u00b1 5 cm . Esta medida sigue siendo adecuada para la mayor\u00eda de los entornos cl\u00ednicos y permite una mayor flexibilidad en la oferta de equipos, sin comprometer la comodidad o funcionalidad necesaria para los cuidados cr\u00edticos", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:24:49-04:00"}, {"id": "65331e1bed2e5f69e8aa74aa474802f4-1", "date": "2024-09-17T17:42:47-04:00", "title": "ITEM 34", "description": "En el \u00edtem 34 de las Especificaciones t\u00e9cnicas donde dice \u201cElastosonograf\u00eda por Strain con representaci\u00f3n de histograma en el ROI, compatible para uso con transductores convexo, lineal y endocavitario\u201d, solicitamos a la convocante que este requisito sea OPCIONAL. Hacerlo opcional permitir\u00e1 una mayor flexibilidad y optimizaci\u00f3n de costos, adaptando el equipo a las necesidades espec\u00edficas de cada usuario y facilitando una oferta m\u00e1s competitiva", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:16:17-04:00"}, {"id": "6ae0adc844729ef7562583e6f7c478d8-1", "date": "2024-09-18T22:27:36-04:00", "title": "ID 443857 - \u00cdtem 34 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Pantalla t\u00e1ctil integrada para acceso al men\u00fa secundario de 13 o superior con ajuste de brillo y resoluci\u00f3n de al menos 1920x1080, que permita el manejo interactivo del men\u00fa, para acceso a modos de operaci\u00f3n, aplicaciones y configuraciones\" solicitamos a la convocante modificar este punto a \"Pantalla t\u00e1ctil integrada para acceso al men\u00fa secundario de 10\" o superior con ajuste de brillo y resoluci\u00f3n de al menos 1024x768, que permita el manejo interactivo del men\u00fa, para acceso a modos de operaci\u00f3n, aplicaciones y configuraciones.\" La diferencia solicitada es m\u00ednima, adem\u00e1s, lo solicitado constituye una caracter\u00edstica meramente constructiva que no afecta a la calidad de imagen. Por lo que solicitamos que modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:29:23-04:00"}, {"id": "0ad55872451dcd4de7abc8a246b16d4c-1", "date": "2024-09-18T16:09:17-04:00", "title": "Plan de entrega de los bienes", "description": "Tratando de equipos, cajas de instrumentales en su mayor\u00eda importados, solicitamos a la convocante ampliar el plazo de entrega a 90 d\u00edas.", "answer": "Remitirse a la respuesta de la consulta 1.", "dateAnswered": "2024-09-26T07:27:43-04:00"}, {"id": "6b4d3087faa70646a04f81f2721d56fb-1", "date": "2024-09-25T17:32:05-04:00", "title": "ESPECIFICACIONES TECNICAS - ITEM 20. 4.5", "description": "\"Capacidad de ampliar el largo total del lecho de forma manual: 25 cm \u00b1 5 cm\", solicitamos a la convocante considerar ajustar la especificaci\u00f3n a 25 cm o mayor. Esto proporcionar\u00eda una mayor flexibilidad en el ajuste del lecho, permitiendo una mejor adaptaci\u00f3n a las necesidades de pacientes de diferentes alturas, sin comprometer la funcionalidad del equipo en entornos cl\u00ednicos", "answer": "Respondido en la Consulta 261.", "dateAnswered": "2024-09-26T14:25:01-04:00"}, {"id": "583a0eec9c3627b057e4e6439b5728cb-1", "date": "2024-09-18T14:19:00-04:00", "title": "\u00cdtem 24 Cardiodesfibrilador", "description": "7.2 Amplitud del pulso seleccionable en un rango de 8 mA o \u00b1 2 mA a 150 mA \u00b1 10 mA.\n\u00bfSe podr\u00eda considerar de 8mA o \u00b1 3 mA?", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:20:01-04:00"}, {"id": "9b4497af979723eee998d6bbf4a2423c-1", "date": "2024-09-18T14:33:24-04:00", "title": "\u00cdTEM 35 EC\u00d3GRAFO", "description": "Se solicita a la convocante admitir Transductor Phased Array pedi\u00e1trico con un ancho de banda de 2 a 8 Mhz. . Para dar mayor participaci\u00f3n a oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:23:32-04:00"}, {"id": "88f89eb813dd94bc6d847915a5c801f7-1", "date": "2024-09-18T22:24:22-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Donde dice \"Profundidad de imagen m\u00e1xima de 44 cm o mayor\" solicitamos a la convocante modificar este punto a \"Profundidad de imagen m\u00e1xima de 30 cm o mayor\" dicho par\u00e1metro solicitado es est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos que modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:28:50-04:00"}, {"id": "1521ef95f4b79179ee7b88bdba84d8c7-1", "date": "2024-09-18T18:52:11-04:00", "title": "Item 36 \u2013 Electrocardiografo", "description": "Solicitamos aclaraci\u00f3n de este punto36 5.1 Modo de Adquisici\u00f3n Simult\u00e1nea de entrada de al menos 16.000 muestras, considerando que las muestras se adquieren por un tiempo determinado y no \u00b4pueden ser almacenadas.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:14:32-04:00"}, {"id": "ba2e6bfd4bd04daa7f0e004051b221a9-1", "date": "2024-09-18T14:20:35-04:00", "title": "Plan de entregas", "description": "Solicitamos ampliar el plan de entregas a por lo menos 60 d\u00edas desde la firma del contrato para los \u00edtems: 7, 16, 20, 21, 24, 25, 29, 32, 33, 34, 35, 36, 37, 38, 41, 42, 44, 45, 48, 53, 54, 56 y 67, teniendo en cuenta la complejidad de los mismos", "answer": "Remitirse a la respuesta de la consulta 1.", "dateAnswered": "2024-09-26T07:23:00-04:00"}, {"id": "1fb39d8c5202eb24be26dea2be2e5b58-1", "date": "2024-09-18T22:49:55-04:00", "title": "CAPACITACION", "description": "8.4 Capacitaci\u00f3n a usuarios sobre el funcionamiento del equipo y capacitaci\u00f3n t\u00e9cnica al personal t\u00e9cnico del Departamento de Electromedicina. Presentar declaraci\u00f3n jurada. \nSe solicita amablemente a la convocante especificar la cantidad de horas necesarias para realizar el entrenamiento. Sin embargo, se sugiere que para cumplir con dicho punto es m\u00e1s que suficiente 8 horas por 3 d\u00edas y de esta manera cubrir con todos los puntos que pueden realizar los usuarios", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:42-04:00"}, {"id": "eacccaab5070280cb720c52e69e51741-1", "date": "2024-09-18T19:15:13-04:00", "title": "item 20 Cama electrica", "description": "En el Item 20 Cama el\u00e9ctrica a para paciente: En el punto 5.2 Solicitan Elevaci\u00f3n el\u00e9ctrica de la secci\u00f3n de espalda. Rango de 0\u00b0 a 80\u00b0 \u00b1 5\u00b0, Solicitamos a la convocante poder cotizar con rango de 0\u00b0 a 70\u00b0 +/- 5\u00b0.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:16:45-04:00"}, {"id": "858b3bd9052098ace23a474d449d9fc9-1", "date": "2024-09-18T21:31:12-04:00", "title": "\u00cdtem 10 - SET DE INSTRUMENTALES PARA CAJA DE ABDOMEN \u2013 TORAX.", "description": "En el punto 2.39 donde solicitan 1 MANGO BISTUR\u00cd NO. 4 LARGO, de 15 a 16 cm de longitud\n\nFavor considerar aceptar y/o modificar la longitud del material a 21,5 (+/- 1cm) considerando que esta medida es la mas utilizada para este tipo de cirug\u00edas donde se necesita instrumentales largos por la profundidad.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:27:36-04:00"}, {"id": "10129c530baee37034f65474339fc2b3-1", "date": "2024-09-18T15:47:12-04:00", "title": "Especificaciones T\u00e9cnicas: Cajas de Cirug\u00eda", "description": "Para todos los \u00edtems de Cajas de Cirug\u00eda en donde menciona el punto:  Se aceptar\u00e1 una variaci\u00f3n de 2+/-cm en las medidas de los instrumentales.\n\u00bfFavor aclarar si es m\u00e1s menos 2 cm sobre las \u00faltimas medidas de las especificaciones? \nEjemplo de 12 a 14 cm ser\u00e1 desde 10 cm hasta 16 cm?", "answer": "Respondido en la consulta 82.", "dateAnswered": "2024-09-26T07:24:16-04:00"}, {"id": "0f930f5c56626acf549285341c03fb92-1", "date": "2024-09-23T14:57:10-04:00", "title": "ANTICIPO", "description": "Solicitamos a la convocante cual ser\u00eda la vigencia de la garant\u00eda del anticipo ya que el pbc establece que la Garant\u00eda de anticipo debe cubrir el cien por ciento (100%) del valor del Anticipo con vigencia de 30 d\u00edas posteriores al cumplimiento de las obligaciones ya que este punto no se encuentra claro o bien definido.", "answer": "Para la fijaci\u00f3n del plazo de vigencia de la garant\u00eda se considerar\u00e1 todo el plazo de ejecuci\u00f3n del objeto del contrato, m\u00e1s un periodo de 30 d\u00edas calendarios, contados a partir de la fecha de cumplimiento total de las obligaciones en virtud del mismo contrato.", "dateAnswered": "2024-09-26T13:53:20-04:00"}, {"id": "56d2dbfdd4634f70ec679005ea848826-1", "date": "2024-09-18T16:05:34-04:00", "title": "item  24", "description": "Donde dice: 4.5 Conectividad Bluetooth para transmisi\u00f3n de datos de descarga a trav\u00e9s de software para PC.\nSolicitamos diga: 4.5 Conectividad Bluetooth o Wireless para transmisi\u00f3n de datos de descarga a trav\u00e9s de software para PC", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:26:25-04:00"}, {"id": "bb5c8340c5e845f14665af85a21c2ed0-1", "date": "2024-09-18T22:24:38-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Donde dice \"Optimizaci\u00f3n Vascular autom\u00e1tica para la correcci\u00f3n de posici\u00f3n y \u00e1ngulo de la caja de Doppler color y Doppler Pulsado siguiendo el curso del vaso sangu\u00edneo\" solicitamos a la convocante considerar este punto como OPCIONAL debido a que esta caracter\u00edstica encarece significativamente el precio referencial del ecocardi\u00f3grafo requerido.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:52-04:00"}, {"id": "6af6d1afc09cda4366b9f77b65c9e8ca-1", "date": "2024-09-18T14:19:10-04:00", "title": "\u00cdtem 24 Cardiodesfibrilador", "description": "11.2 Para papel de 50 mm.\n\u00bfSe podr\u00eda considerar de 50 a 58mm?", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:20:07-04:00"}, {"id": "21e80d6617ec27a77fc4ff720b1454eb-1", "date": "2024-09-18T14:18:20-04:00", "title": "\u00cdtem 16 Monitor Multiparam\u00e9trico", "description": "4.6.3 Medici\u00f3n de variaci\u00f3n de presi\u00f3n sist\u00f3lica (VPS), variaci\u00f3n de presi\u00f3n de pulso (VPP), presi\u00f3n de perfusi\u00f3n cerebral (PPC), medici\u00f3n de la presi\u00f3n venosa central al final de la expiraci\u00f3n (PVC-ET).\n\u00bfPodr\u00eda ser considerado OPCIONAL?", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:19:43-04:00"}, {"id": "d9029576cefa68be9f914dc946711e86-1", "date": "2024-09-14T11:04:45-04:00", "title": "Especificaciones T\u00e9cnicas - \u00cdtem 53) Monitor Multiparam\u00e9trico", "description": "4.15 Capacidad de visualizacion via remota de curvas y tendencias desde cualquier dispositivo dentro y fuera de la Unidad Medica\n\nSolicitamos modificar el requerimiento para que la visualizaci\u00f3n remota de curvas y tendencias se limite a dispositivos conectados a la central de monitoreo dentro de la Unidad M\u00e9dica. Esta centralizaci\u00f3n asegura un mayor control sobre los datos cl\u00ednicos sensibles, reduciendo riesgos de seguridad y asegurando que solo el personal autorizado tenga acceso a la informaci\u00f3n. Adem\u00e1s, garantiza una infraestructura t\u00e9cnica m\u00e1s robusta y adecuada para el monitoreo en tiempo real, mejorando la confiabilidad del sistema.", "answer": "Remitirse a la Adenda en el SICP.", "dateAnswered": "2024-09-26T07:14:19-04:00"}, {"id": "61c6fc2c1d5705e7517e744cf80afcd0-1", "date": "2024-09-18T14:19:05-04:00", "title": "\u00cdtem 24 Cardiodesfibrilador", "description": "7.2 Amplitud del pulso seleccionable en un rango de 8 mA o \u00b1 2 mA a 150 mA \u00b1 10 mA.\n\u00bfSe podr\u00eda considerar de 8 mA o \u00b1 3 mA a 150 mA \u00b1 50 mA?", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:20:03-04:00"}, {"id": "e0fead532d93c048a85aaf3490b55c3d-1", "date": "2024-09-18T22:50:52-04:00", "title": "CAPACITACION", "description": "ITEM 33 : Punto 8.4 Capacitaci\u00f3n a usuarios sobre el funcionamiento del equipo y capacitaci\u00f3n t\u00e9cnica al personal t\u00e9cnico del Departamento de Electromedicina. Presentar declaraci\u00f3n jurada. \nSe solicita amablemente a la convocante especificar la cantidad de horas necesarias para realizar el entrenamiento. Sin embargo, se sugiere que para cumplir con dicho punto es m\u00e1s que suficiente 8 horas por 3 d\u00edas y de esta manera cubrir con todos los puntos que pueden realizar los usuarios.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:46-04:00"}, {"id": "5d57962ab4c6a2ada4b3f28aab807520-1", "date": "2024-09-18T17:40:43-04:00", "title": "\u00cdtem 53 \u2013 Monitor Multiparam\u00e9trico", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 5.6.2 se solicita \u201cEtiquetado del sitio de medici\u00f3n: al menos P1, P2, P3, ART, ART2, RAD, DORS, AO, FEM, UA, UV, PAP, CVP, RAP, RVP, LAP, LVP, ICP, ICP2, ICP3.\u201d, solicitamos a la convocante modificar este punto por \u201cEtiquetado del sitio de medici\u00f3n al menos 15 etiquetas\u201d de manera a que lo solicitado se ajuste a las tecnolog\u00edas disponibles en el mercado y por sobre todo a los Monitores de Baja Complejidad tal como se solicita en el punto 4.1", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:30:38-04:00"}, {"id": "131132863d631c5f73c4d042f781c2d6-1", "date": "2024-09-18T21:11:52-04:00", "title": "\u00cdtem 37: Equipo para tratamiento de hemodi\u00e1lisis", "description": "El PBC solicita Concentraci\u00f3n de desinfectante programable Se solicita amablemente a la convocante que, de manera a permitir la competencia de marcas de gran reconocimiento a nivel mundial y experiencia comprobada en el mercado local, y sin ir en detrimento de lo solicitado, atendiendo  a que cada maquina cuenta con subsistemas de detecci\u00f3n de concentraciones de l\u00edquidos desinfectantes y desincrustantes aptos y validados  para los programas de limpieza, descalcificaci\u00f3n y desinfecci\u00f3n, por lo que planteamos la siguiente reformulacion del requisito: Concentraci\u00f3n de desinfectante programable (opcional), a fin de brindar mayor oportunidad de participacion a los oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:27:11-04:00"}, {"id": "ea694a6bdcecf2c3dd378caf4e0a2db3-1", "date": "2024-09-18T22:29:43-04:00", "title": "ID 443857 - \u00cdtem 34 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Al menos 15.000.000 de canales de procesamiento digital\" solicitamos a la convocante modificar este punto a \"Al menos 172.000 canales de procesamiento digital\" Lo solicitado obedece a que cada casa comercial calcula los canales de procesamiento digitales mediante una f\u00f3rmula matem\u00e1tica propia, que no se ha estandarizado en el mercado y lo cual hace que los n\u00fameros de canales digitales no sean comparables entre una marca y otra.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:34:36-04:00"}, {"id": "ef57e5fc33bbd7a2b645a0bf3030c949-1", "date": "2024-09-18T19:23:02-04:00", "title": "ESPECIFICACIONES TECNICAS - 34. Punto 4.10", "description": "\u201cCapacidad de almacenamiento en disco de estado s\u00f3lido (SSD) de al menos 512 GB.\u201d Solicitamos a la convocante que ajuste la especificaci\u00f3n de \"Capacidad de almacenamiento en disco de estado s\u00f3lido (SSD) de al menos 512 GB\" a un rango de 500 GB o m\u00e1s. Esto permitir\u00e1 una mayor flexibilidad en la selecci\u00f3n del equipo y asegurar\u00e1 que se mantengan opciones viables tanto en t\u00e9rminos de costo como de capacidad para cumplir con los requisitos operativos del equipo.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:17:09-04:00"}, {"id": "f270c88d0fa1afa17ab844a0a0d69063-1", "date": "2024-09-25T17:37:28-04:00", "title": "ESPECIFICACIONES TECNICAS - ITEM 20. 5.2", "description": "Donde se solicita \"Elevaci\u00f3n el\u00e9ctrica de la secci\u00f3n de espalda. Rango de 0\u00b0 a 80\u00b0 \u00b1 5\u00b0\" Solicitamos a la convocante considerar la especificaci\u00f3n para la elevaci\u00f3n el\u00e9ctrica de la secci\u00f3n de espalda, modificando el rango requerido de 0\u00b0 a 80\u00b0 \u00b1 5\u00b0 a un rango de 0\u00b0 a 75\u00b0 \u00b1 5\u00b0. Este ajuste proporcionar\u00eda mayor flexibilidad en el manejo de la cama, facilitando un mejor acceso para los profesionales de la salud y ofreciendo m\u00e1s comodidad para el paciente en diferentes contextos cl\u00ednicos, sin comprometer la funcionalidad de la cama", "answer": "Respondido en la Consulta 265.", "dateAnswered": "2024-09-26T14:25:05-04:00"}, {"id": "e99960993e7f571127bedaeab99fdbbb-1", "date": "2024-09-17T17:33:58-04:00", "title": "ITEM 34", "description": "En relaci\u00f3n con Item 34 de las Especificaciones t\u00e9cnicas donde se solicita \u201c Cine memory de al menos 9000 cuadros\u201d solicitamos a la convocante la modificaci\u00f3n de este \u00edtem por \u201c Cine memory de al menos 2000 cuadros\u201d ,este ajuste permite cumplir con los est\u00e1ndares del mercado actual y  facilita la participaci\u00f3n de un mayor n\u00famero de oferentes adem\u00e1s de optimizar el costo del equipo, asegurando un proceso de adquisici\u00f3n m\u00e1s eficiente y competitivo.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:15:58-04:00"}, {"id": "d9ec014d49ef86cc22e43dfced78636b-1", "date": "2024-09-18T19:30:19-04:00", "title": "Item 42 Ventilador Pulmonar", "description": "En el \u00cdtem 42 Ventilador pulmonar de alta complejidad: En el punto 10.12 Pantalla secundaria para control y monitorizaci\u00f3n del ventilador de 19\"\u00b1 2\". Conexi\u00f3n a la pantalla principal al\u00e1mbrica o inal\u00e1mbrica. Una (1)unidad por la totalidad de equipos incluyendo el carro para la pantalla secundaria, nuevamente vemos que estas especificaciones t\u00e9cnicas son de la marca Nihon Kohden por lo tanto podr\u00edan realizar un llamado por v\u00eda de la excepci\u00f3n para solicitar a LCM que coticen sus ventiladores. Por lo tanto, solicitamos que este punto sea opcional por lo expuesto anteriormente-", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:17:41-04:00"}, {"id": "a7d57b72046221e7f4686173b8ba79e8-1", "date": "2024-09-18T09:39:53-04:00", "title": "Especificaciones tecnicas", "description": "SOLICITAMOS a la convocante modifique el punto 9.6 \"Pantalla LCD de 19 \u00b1 2\".Perilla o botones selectores para ajuste de valores.\", a Pantalla LCD de 16 \u00b1 2\".Perilla o botones selectores para ajuste de valores ya que esta modificaci\u00f3n no afecta la calidad y eficacia del equipo, ademas de no limitar la participaci\u00f3n.", "answer": "No es posible identificar la consulta, no figura el numero de item.", "dateAnswered": "2024-09-26T07:17:41-04:00"}, {"id": "29d7f8524723d2bb3921876cedca8c9a-1", "date": "2024-09-18T22:22:25-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Para el \u00edtem 33 el PBC establece que el Plan de entrega de los bienes ser\u00e1: \"El 100 % dentro de los 30 d\u00edas a partir de la firma del contrato\" Favor solicitamos a la convocante modificar este punto a \"El 100 % dentro de los 90 d\u00edas posteriores a la recepci\u00f3n de la orden de compra por parte del proveedor\".  Lo solicitado obedece en su mayor\u00eda se trata de equipos cuya fabricaci\u00f3n se realiza tras un pedido al fabricante mediante orden de compra, y que posteriormente son importados, por lo que el plazo debe indefectiblemente incluir tiempo de transporte internacional y los procesos aduaneros realizados por terceros.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:24-04:00"}, {"id": "236b855973f16c2231624471dc333e97-1", "date": "2024-09-18T22:23:22-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Donde dice \"Disco duro interno SSD de al menos 1TB\"solicitamos a la convocante modificar este punto a \u201cDisco duro interno SSD de al menos 500 GB o mayor\u201d el valor solicitado es el est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda. El valor de 1 TB limita innecesariamente la participaci\u00f3n de potenciales oferentes, ya que esta caracter\u00edstica se encuentra presente en muy pocos modelos disponibles en el mercado.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:28:39-04:00"}, {"id": "215ee3c4a38d2980be7cf3d10131c37d-1", "date": "2024-09-17T15:20:36-04:00", "title": "ITEM 34", "description": "Item 34 punto  6.1.6  donde dice: Al menos 15.000.000 de canales digitales \nSolicitamos que el m\u00ednimo sea de aproximadamente 6 millones para mayor participaci\u00f3n de oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:15:09-04:00"}, {"id": "a3b1a1ab1144062e5042dee2d81fdc9d-1", "date": "2024-09-18T22:34:51-04:00", "title": "ID 443857 - \u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Para el \u00edtem 35 Donde dice \"Los equipos deber\u00e1n contar con 2 (dos) a\u00f1os de garant\u00eda desde la puesta en funcionamiento, e incluir como m\u00ednimo 1 (un) mantenimiento preventivo anual durante dicho periodo\" solicitamos a la convocante aclarar si la garant\u00eda solicitada incluye repuestos. Adem\u00e1s, solicitamos confirmar que la garant\u00eda no incluir\u00e1 los da\u00f1os que pudiere sufrir el equipo por errores de utilizaci\u00f3n, golpes y/o desgaste natural como son los transductores.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:35:13-04:00"}, {"id": "e1826dd81c382bc1380a5a7f9ea0dd47-1", "date": "2024-09-18T14:19:19-04:00", "title": "\u00cdtem 25 Cardiodesfibrilador", "description": "7.4 Frecuencia de marcapasos ajustable en el rango de 40 \u00b15 pulsos por minuto a 180 \u00b110 pulsos .\n\u00bfSe podr\u00eda considera de 40 o menos a 180 o m\u00e1s?", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:21:21-04:00"}, {"id": "00244ed9d1091076a7ef95b5e629acb7-1", "date": "2024-09-18T22:08:06-04:00", "title": "ITEM 44 \u2013 MAQUINA DE ANESTESIA", "description": "En el punto 5.3 donde dice \u201cCon medicion y aplicaci\u00f3n de los parametros respiratorios en pantalla LCD o LED color de 19 pulgadas \u00b1 2\"\u201d solicitamos amablemente a la convocante permita cotizar equipos con pantalla de al menos 15\u201d y asi dar apertura a las especificaciones t\u00e9cnicas para la participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:11-04:00"}, {"id": "eb5129f4dc58c5a34c168a23848d49e6-1", "date": "2024-09-14T11:03:44-04:00", "title": "Especificaciones T\u00e9cnicas  - \u00cdtem 16) Monitor Multiparam\u00e9trico", "description": "6.1 Con al menos 8 canales de EEG\n\nSolicitamos modificar el requerimiento de al menos 8 canales de EEG a 4 canales, ya que en muchos casos cl\u00ednicos rutinarios, 4 canales son suficientes para obtener informaci\u00f3n precisa y relevante sobre la actividad cerebral del paciente. Esta reducci\u00f3n no compromete la calidad del monitoreo en entornos donde no se requiere una alta resoluci\u00f3n de datos, adem\u00e1s de que simplifica el an\u00e1lisis y optimiza el uso de recursos. La reducci\u00f3n a 4 canales permite un equipo m\u00e1s accesible y eficiente sin perder eficacia diagn\u00f3stica en la mayor\u00eda de los escenarios cl\u00ednicos.", "answer": "Remitirse a la Adenda en el SICP.", "dateAnswered": "2024-09-26T07:14:10-04:00"}, {"id": "c423ae24634d16a8b6bc262e6f506c46-1", "date": "2024-09-18T22:29:49-04:00", "title": "ID 443857 - \u00cdtem 34 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Magnificaci\u00f3n de im\u00e1genes (Zoom) hasta 50x en tiempo real\" solicitamos a la convocante modificar este punto a \"Magnificaci\u00f3n de im\u00e1genes (Zoom) hasta 10x en tiempo real\" lo solicitado es est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos que modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:34:38-04:00"}, {"id": "510db8e68d3e5ead7f0d7357741ce54d-1", "date": "2024-09-13T12:15:08-04:00", "title": "Especificaciones t\u00e9cnicas. \u00cdtem 40 ESTUFA DE SECADO", "description": "\u00cdtem 40 estufa de secado: El PBC establece, pantalla LED.\nFavor considerar incluir opcional con pantalla LCD, ya que esto no afecta en las funciones del equipo y favorece la mayor participaci\u00f3n.", "answer": "Remitirse a la Adenda en el SICP.", "dateAnswered": "2024-09-26T07:09:08-04:00"}, {"id": "a29bf4e97ad582d71f74d89fe1cd4bd8-1", "date": "2024-09-18T14:19:37-04:00", "title": "\u00cdtem 26 Carro de paro", "description": "4.1 Estructura en pol\u00edmero de alta densidad, con tablero de ABS y barandilla en acero inoxidable AISI 304.\n\u00bfSe podr\u00eda considerar Estructura en pol\u00edmero de alta densidad o acero al carbono, con tablero de ABS y barandilla en acero inoxidable AISI 304?", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:21:51-04:00"}, {"id": "7c04ccb8ffaa6d5681f20974f1700221-1", "date": "2024-09-17T18:02:14-04:00", "title": "CONSULTA 2. ITEM 20 \u2013 CAMA EL\u00c9CTRICA PARA PACIENTE.", "description": "En el punto: \u201c5.1 Altura ajustable el\u00e9ctricamente (medido de la plataforma de la cama al piso, sin colch\u00f3n). Altura m\u00ednima 55cm +/- 5cm. Altura m\u00e1xima 85cm +/- 5cm\u201d.\nSe solicita amablemente a la convocante poder ampliar estos puntos para permitir mayor participaci\u00f3n. Se solicita altura m\u00ednima 45cm +/- 10cm y altura m\u00e1xima 85cm +/- 10cm. Con esta modificaci\u00f3n no se alterar\u00e1 el pedido original y la misma trae un beneficio en el rango de altura al ser m\u00e1s baja para mayor facilidad de salida del paciente y al ser m\u00e1s alta para procedimientos.", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:17:16-04:00"}, {"id": "a4af31092ef932cbc9db42365985d1a9-1", "date": "2024-09-18T17:44:06-04:00", "title": "\u00cdtem 44 \u2013 M\u00e1quina de Anestesia", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 5.16 se solicita \u201cMedici\u00f3n de volumen minuto, volumen tidal espirado, presi\u00f3n pico, presi\u00f3n plateu, presi\u00f3n media, PEEP, PEEP intr\u00ednseca, Compliance, Resistencia del pulm\u00f3n del paciente.\u201d solicitamos a la Convocante pueda modificar este punto por \u201cMedici\u00f3n de volumen minuto, volumen tidal espirado, presi\u00f3n pico, presi\u00f3n plateu, presi\u00f3n media, PEEP, Compliance, Resistencia del pulm\u00f3n del paciente.\u201d La PEEPi es un par\u00e1metro t\u00edpico en equipos de alta complejidad, por lo que al solicitar este par\u00e1metro se deben ofertar equipos de muchas m\u00e1s prestaciones que las solicitadas, unicamente para que cumpla con este punto. Se debe tener en cuenta que el equipo solicitado es un equipo de mediana complejidad.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:10:07-04:00"}, {"id": "f36123cac512f414fe05c0ad9de6c388-1", "date": "2024-09-18T22:48:29-04:00", "title": "CAPACIDAD TECNICA", "description": "Capacidad T\u00e9cnica punto 12- Declaraci\u00f3n jurada de que la empresa adjudicada se compromete a: - Que proveer\u00e1 Asistencia t\u00e9cnica seg\u00fan necesidad, sea mantenimiento preventivo o correctivo, en un periodo menor a 48 hs., stock de repuestos y accesorios originales de f\u00e1brica. Solicitamos a la Convocante aclarar que el plazo de provisi\u00f3n de repuestos sea de al menos 15 d\u00edas h\u00e1biles debido a que existen ciertas piezas de repuestos que no pueden ser almacenadas en stock, por lo que indefectiblemente deben ser importadas de f\u00e1brica", "answer": "Remitirse a la Adenda en el SICP.", "dateAnswered": "2024-09-26T08:36:37-04:00"}, {"id": "e9777b53122c256b936fe86be71a5b45-1", "date": "2024-09-17T17:43:19-04:00", "title": "ITEM 35", "description": "En el \u00edtem 35 de las Especificaciones t\u00e9cnicas donde dice \u201cDos puertos activos para conexi\u00f3n de transductores integrados al equipo sin necesidad del uso de adaptador\u201d, solicitamos la modificaci\u00f3n de este por \u201cUn puerto activo o m\u00e1s para la conexi\u00f3n de transductores\u201d, esta modificaci\u00f3n no afecta las caracter\u00edsticas esenciales del equipo y est\u00e1 en l\u00ednea con los est\u00e1ndares actuales del mercado de equipos port\u00e1tiles, permitiendo una mayor flexibilidad en las ofertas.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:16:33-04:00"}, {"id": "35392e358c965e891ef249c866f4ac3f-1", "date": "2024-09-18T17:51:43-04:00", "title": "\u00cdTEM 34 EC\u00d3GRAFO", "description": "Se solicita a la convocante admitir Controles TGC digital: 8 deslizadores, Para dar mayor participaci\u00f3n a oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:10:49-04:00"}, {"id": "97314f65cd10dd75617631c46aa35b1b-1", "date": "2024-09-18T18:48:56-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 33 punto 2.7", "description": "\u201cDisco duro interno SSD de al menos 1TB\u201d Solicitamos a la convocante que considere no limitar la especificaci\u00f3n del disco duro a un SSD de al menos 1TB, y permita tambi\u00e9n la opci\u00f3n de un HDD de capacidad equivalente. Esto permitir\u00eda una mayor diversidad en las propuestas, manteniendo la capacidad de almacenamiento solicitada sin comprometer el rendimiento del equipo.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:12:58-04:00"}, {"id": "f2e3c56c7a18938e6c19c480db355e20-1", "date": "2024-09-18T22:30:25-04:00", "title": "ID 443857 - \u00cdtem 34 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Hasta 15 \u00e1ngulos de direcci\u00f3n de transductor conmutables din\u00e1micamente\" solicitamos a la convocante modificar este punto a \"Hasta 7 \u00e1ngulos de direcci\u00f3n de transductor conmutables din\u00e1micamente\" lo solicitado es est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos que modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:34:44-04:00"}, {"id": "435c3eb2c29cc548abd21400c2e8c3f6-1", "date": "2024-09-18T18:51:54-04:00", "title": "Item 36 \u2013 Electrocardiografo", "description": "Donde dice:  36 4.3 Monitor TFT LCD Color Touch de 10 \u00b1 2\", con 1024x768 o mejor. Solicitamos se puedan cotizar resoluci\u00f3n de pantalla de 800 x 480 pixeles, esto es suficiente para una pantalla peque\u00f1a.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:14:24-04:00"}, {"id": "19b17f9576a3f2e88dba63fd008e0359-1", "date": "2024-09-25T22:12:54-04:00", "title": "EETT ITEM 23. 2.8", "description": "En relaci\u00f3n con la especificaci\u00f3n de \"Ancho de 65 cm \u00b1 5 cm\", solicitamos a la convocante considerar ajustar las especificaciones a 75 cm \u00b1 5 cm. Este ajuste proporcionar\u00eda una mayor comodidad y espacio para el paciente, permitiendo una mejor adaptaci\u00f3n de colchones y accesorios cl\u00ednicos, sin comprometer la funcionalidad o el rendimiento del equipo en entornos cl\u00ednicos\u00a0cr\u00edticos.", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:25:53-04:00"}, {"id": "9942b477f793c14a275891a96c0a2183-1", "date": "2024-09-17T17:32:43-04:00", "title": "item 34. Ecografo", "description": "6.2.10 Imagen trapezoidal hasta 70cm +/-10cm (funcionalidad para transductores lineales) \nCreemos que hay un error de tipeo en la solicitud y debe decir: 6.2.10 Imagen trapezoidal hasta 70% +/-10% (funcionalidad para transductores lineales)", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:15:44-04:00"}, {"id": "1c402fa61e1015fe78e51ed4ed737a08-1", "date": "2024-09-18T17:45:02-04:00", "title": "\u00cdtem 45 \u2013 M\u00e1quina de Anestesia", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 5.21 se solicita \u201cMedici\u00f3n de agentes anest\u00e9sicos (Sevoflurano, Isoflurano, Halotano, Enflurano y Desflurano), fracci\u00f3n inspirada y fracci\u00f3n espirada. Medici\u00f3n en mL de cada agente anest\u00e9sico\u201d solicitamos a la Convocante pueda modificar este punto por \u201cMedici\u00f3n de agentes anest\u00e9sicos (Sevoflurano, Isoflurano, Halotano, Enflurano y Desflurano), fracci\u00f3n inspirada y fracci\u00f3n espirada.\u201d. La gran mayor\u00eda de las marcas mundiales de m\u00e1quinas de anestesias miden sus niveles de agentes anest\u00e9sicos en porcentajes, por lo que solicitar la medici\u00f3n en mL ser\u00eda limitar la participaci\u00f3n de todas ellas, solicitamos esta modificaci\u00f3n de manera a permitir un mayor n\u00famero de oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:10:37-04:00"}, {"id": "6817fa814057059ab62449bdc60aa451-1", "date": "2024-09-18T18:51:45-04:00", "title": "Item 25 \u2013 Cardiodesfibrilador", "description": "Donde dice: 25 5.2 Energ\u00eda seleccionable por pasos, modo bif\u00e1sico. Limite inferior: 1 Joules \u00b1 1 J. L\u00edmite superior: 270 Joules o m\u00e1s. Solicitamos se revise esta especificaci\u00f3n puesto que en la tecnolog\u00eda bif\u00e1sica no se proporciona al paciente m\u00e1s de 200 J-", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:14:19-04:00"}, {"id": "332d4628e89bac9b0ae4eb083ca22a8f-1", "date": "2024-09-18T20:18:53-04:00", "title": "ESPECIFICACIONES TECNICAS - ITEM 37", "description": "En el punto 2.1 \u201cIluminaci\u00f3n por fibra \u00f3ptica\u201d, solicitamos que en esta convocatoria se considere la inclusi\u00f3n de alternativas como la iluminaci\u00f3n por LED, que ofrece una eficiencia energ\u00e9tica superior y un costo operativo inferior. Esto contribuir\u00e1 a ampliar la cantidad de oferentes en la licitaci\u00f3n.", "answer": "La consulta no corresponde al item.", "dateAnswered": "2024-09-26T08:18:25-04:00"}, {"id": "47ea49a29b6a3e7767f36e814eb51887-1", "date": "2024-09-18T17:01:43-04:00", "title": "ITEM 1 1 2.7 Filtro de aire en la salida del aspirador hacia el ambiente", "description": "Para este punto se solicita a la convocante aceptar filtro hidrof\u00f3bico a la entrada de la bomba del aspirador. De este modo se filtrar\u00eda el 99,9 % de virus y bacterias", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:28:00-04:00"}, {"id": "1fbbbc704ffe8151ef6ee7b7eda9e18f-1", "date": "2024-09-18T19:21:39-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 34. 7.4", "description": "\u201cTransductor endocavitario con ancho de banda de 3MHz o menor a 12 MHz o mayor. Con \u00e1ngulo de apertura de al menos 240\u00b0. Compatible para uso de elastosonograf\u00eda. Cantidad: 01 (una) unidad por cada equipo\u201d  Solicitamos a la convocante que considere ajustar la especificaci\u00f3n de \"Ancho de banda de 3 MHz o menor a 12 MHz o mayor\" a un rango de 3 MHz o menor a 12 \u00b12 MHz. Tambi\u00e9n solicitamos ajustar el \"\u00c1ngulo de apertura de al menos 240\u00b0\" a un rango de 165 \u00b15\u00b0. Un \u00e1ngulo de apertura de 165\u00b0 es suficiente para la mayor\u00eda de las aplicaciones cl\u00ednicas y ayudar\u00e1 a mantener la viabilidad t\u00e9cnica y econ\u00f3mica de los equipos, mientras que el rango ajustado en MHz asegura que el transductor siga siendo compatible con los est\u00e1ndares cl\u00ednicos necesarios para elastosonograf\u00eda. Este ajuste permitir\u00e1 una mayor competitividad entre los proveedores y un equilibrio m\u00e1s adecuado con los costos de los equipos.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:17:06-04:00"}, {"id": "61181c3f157a0e80166e5f39274febd6-1", "date": "2024-09-18T17:51:49-04:00", "title": "\u00cdTEM 34 EC\u00d3GRAFO", "description": "Se solicita a la convocante admitir Controles TGC digital: 8 deslizadores, Para dar mayor participaci\u00f3n a oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:11:22-04:00"}, {"id": "1e4246c0f7fb979a9c5454b16aa50988-1", "date": "2024-09-18T18:51:39-04:00", "title": "Item 25 \u2013 Cardiodesfibrilador", "description": "En el punto 25 4.5  Conectividad Bluetooth para transmisi\u00f3n de datos de descarga a trav\u00e9s\nde software para PC, solicitamos se permita cotizar como alternativa que los datos se puedan descargar v\u00eda USB a una PC.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:14:17-04:00"}, {"id": "50800074fdd65048ed21d0b84c8d7767-1", "date": "2024-09-17T15:20:28-04:00", "title": "Item 34 punto", "description": "6.1.9 donde dice\nBeamformer de al menos 16 zonas focales de transductor din\u00e1micamente controlados.\nSolicitamos que el m\u00ednimo sea de 8 zonas focales para mayor participaci\u00f3n de oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:15:06-04:00"}, {"id": "aba1e315ea5d5e9efc82ad1e2032fac3-1", "date": "2024-09-18T22:37:18-04:00", "title": "\u00cdtem 38 \u2013 Equipo de Rayos X M\u00f3vil", "description": "Donde dice \"Carga de 400Kg. distribuida o 200 kg carga localizada o mejor\" solicitamos a la convocante modificar este punto a \"Carga de 300Kg. distribuida o 100 kg carga localizada o mejor\" lo solicitado es el est\u00e1ndar en la mayor\u00eda de los equipos de rayos x m\u00f3vil y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos se actualice este punto a fin de tener la participaci\u00f3n de las marcas con reconocida representaci\u00f3n y comprobada calidad en el mercado local e internacional. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 38 est\u00e1n direccionadas a la marca SHIMADZU modelo MobileArt Eco MUX-10, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:35:52-04:00"}, {"id": "e2bb0b877c139dffac38d7b6ffd2ac2a-1", "date": "2024-09-18T22:27:45-04:00", "title": "ID 443857 - \u00cdtem 34 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Posibilidad de visualizar im\u00e1genes almacenadas en el equipo a trav\u00e9s de la pantalla t\u00e1ctil para realizar comparaciones con la imagen en la pantalla principal y seguimiento de estudios\" solicitamos a la convocante modificar este punto como OPCIONAL, lo solicitado no afecta a la calidad de imagen. Por lo que solicitamos que modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:33:41-04:00"}, {"id": "73967ffd2cf85f08d955457d36aeb86b-1", "date": "2024-09-18T21:03:07-04:00", "title": "\u00cdtem 37: Equipo para tratamiento de hemodi\u00e1lisis", "description": "El PBC solicita TEMPERATURA DE DIALIZADO De 30.0 \u00b0C a 40.0 \u00b0C, Se solicita amablemente a la convocante que, de manera a permitir la competencia de marcas de gran reconocimiento a nivel mundial y experiencia comprobada en el mercado local, y sin ir en detrimento de lo solicitado, atendiendo a rangos reales de ajuste del par\u00e1metro mencionado, sean aceptados equipos con TEMPERATURA DE DIALIZADO (\u00b0C): De 35.0 o menor a 39.0 o mayor, a fin de brindar mayor oportunidad de participacion de los oferentes.", "answer": "Se encuentra dentro del rango solicitado.", "dateAnswered": "2024-09-26T08:27:06-04:00"}, {"id": "f45cdbb624f2144963a472b327b43155-1", "date": "2024-09-18T14:18:15-04:00", "title": "\u00cdtem 16 Monitor Multiparam\u00e9trico", "description": "4.6.2 Etiquetado del sitio de medici\u00f3n: P1, P2, P3, ART, ART2, RAD, DORS, AO, FEM, UA, UV, PAP, CVP, RAP, RVP, LAP, LVP, ICP, ICP2, ICP3.\n\u00bfSe podr\u00eda cotizar: P1, P2, P3, ART, ART2, RAD, DORS, AO, FEM, UA, UV, PAP, CVP, RAP, RVP, LAP, LVP, ICP, ICP2, ICP3 o ART, PA, CVP, ICP, LAP, RAP, P1-P2?", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:19:41-04:00"}, {"id": "d0ece99319abdf7cbc725f9666838d17-1", "date": "2024-09-18T18:56:23-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 33. Punto 5.1", "description": "Posibilidad de agregar en el futuro los siguientes software \u201cSoftware para Strain y Strain Rate del Ventr\u00edculo izquierdo basado en el m\u00e9todo 2D speckle tracking con detecci\u00f3n autom\u00e1tica de bordes\u201d  Solicitamos a la convocante considerar la modificaci\u00f3n del requisito para que la posibilidad de agregar \"Software para Strain y Strain Rate del Ventr\u00edculo Izquierdo basado en el m\u00e9todo 2D speckle tracking con detecci\u00f3n autom\u00e1tica de bordes\" sea un requisito obligatorio en lugar de una opci\u00f3n. Dado que se trata de un ecocardiografo, estas caracter\u00edsticas son esenciales para el an\u00e1lisis avanzado de la funci\u00f3n cardiaca. La inclusi\u00f3n de este software como una caracter\u00edstica obligatoria asegura que los equipos propuestos cumplan con los est\u00e1ndares de alta gama requeridos para aplicaciones cardiol\u00f3gicas espec\u00edficas, garantizando as\u00ed que todos los oferentes ofrezcan soluciones completas y especializadas para la evaluaci\u00f3n cardiaca.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:16:09-04:00"}, {"id": "ffe985fb9d68ee85b75063ea66aef2af-1", "date": "2024-09-18T17:40:49-04:00", "title": "\u00cdtem 53 \u2013 Monitor Multiparam\u00e9trico", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 5.6.3 se solicita \u201cMedici\u00f3n de variaci\u00f3n de presi\u00f3n sist\u00f3lica (VPS), variaci\u00f3n de presi\u00f3n de pulso (VPP), presi\u00f3n de perfusi\u00f3n cerebral (PPC), medici\u00f3n de la presi\u00f3n venosa central al final de la expiraci\u00f3n (PVC-ET).\u201d, solicitamos a la convocante modificar este punto por \u201cOPCIONAL\u201d ya que lo solicitado son par\u00e1metros de un Monitor de Alta complejidad y no se ajusta a las especificaciones de un Monitores de Baja Complejidad tal como se solicita en el punto 4.1. Esta modificaci\u00f3n permitir\u00e1 la participaci\u00f3n de un mayor n\u00famero de oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:33:13-04:00"}, {"id": "c2d2c0e300a0f07c642ab1b29b22a262-1", "date": "2024-09-18T18:52:08-04:00", "title": "Item 36 \u2013 Electrocardiografo", "description": "Donde dice: 36 4.10 Capacidad de 18 derivadas con cables de 10 v\u00edas, sin necesidad de\ncambiar la posici\u00f3n de los electrodos. Solicitamos que este punto sea considerado opcional debido al precio referencial.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:14:30-04:00"}, {"id": "f3f3a936d543b418485ed42f3081dc6e-1", "date": "2024-09-17T17:27:41-04:00", "title": "item 33", "description": "En relaci\u00f3n con el \u00edtem 33 de las Especificaciones T\u00e9cnicas, donde se solicita un \u201cEncendido r\u00e1pido en menos de 60 segundos\u201d, solicitamos respetuosamente que se modifique dicho requerimiento por \u201cEncendido r\u00e1pido de al menos 180 segundos\u201d. Esta modificaci\u00f3n est\u00e1 dentro de los est\u00e1ndares para equipos de la gama solicitada y permitir\u00eda ampliar la participaci\u00f3n de oferentes, manteniendo al mismo tiempo la calidad y funcionalidad esperadas del equipo.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:15:26-04:00"}, {"id": "24e26ee7990059b27aefd6c872208a9d-1", "date": "2024-09-18T18:51:04-04:00", "title": "Item 15 \u2013 Caja de cirug\u00eda general", "description": "Donde solicitan: Certificaci\u00f3n de la calidad de los instrum\u00e9ntales: DIM EN 10088T.1-3, EN ISO 7153-1 , y EN ISO 13485:2016, por favor aclarar que se requiere alguno de ellos.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:13:46-04:00"}, {"id": "72125fba50734d2f6ed3a1518e70cf83-1", "date": "2024-09-18T22:37:10-04:00", "title": "\u00cdtem 38 \u2013 Equipo de Rayos X M\u00f3vil", "description": "Donde dice \"Resistencia al polvo y agua IP67 o mejor\" solicitamos a la convocante modificar este punto a \"El equipo deber\u00e1 contar con protecci\u00f3n IP67, IPX3 o mejor\" lo solicitado es el est\u00e1ndar en la mayor\u00eda de los equipos de rayos x m\u00f3vil y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos se actualice este punto a fin de tener la participaci\u00f3n de las marcas con reconocida representaci\u00f3n y comprobada calidad en el mercado local e internacional. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 38 est\u00e1n direccionadas a la marca SHIMADZU modelo MobileArt Eco MUX-10, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:35:49-04:00"}, {"id": "31b5d6481f7ead9707bb6f7dbb0ae29f-1", "date": "2024-09-18T11:20:45-04:00", "title": "Item 10 - SET DE INSTRUMENTALES PARA CAJA DE ABDOMEN \u2013 TORAX.", "description": "En el punto 2.39 donde solicitan 1 MANGO BISTUR\u00cd NO. 4 LARGO, de 15 a 16 cm de longitud\n\nFavor considerar aceptar y/o modificar la longitud del material a 21,5 (+/- 1cm) considerando que esta medida es la mas utilizada para este tipo de cirug\u00edas donde se necesita instrumentales largos por la profundidad.", "answer": "Respondido en la consulta 82.", "dateAnswered": "2024-09-26T07:18:16-04:00"}, {"id": "7c1c22c9df189000d108fe3643b1a3e5-1", "date": "2024-09-18T21:11:57-04:00", "title": "\u00cdtem 42: Ventilador pulmonar de alta complejidad.", "description": "El PBC solicita Pendiente de inyecci\u00f3n de flujo inspiratorio ajustable (%). De 5 a 100. Se solicita amablemente a la convocante permitir cotizar equipo, sin ir en detrimento de lo solicitado, y permitir la competencia de marcas con experiencia comprobada en el mercado local, sean aceptados equipos con Pendiente de inyecci\u00f3n de flujo inspiratorio ajustable (%). De 5 a 100 (opcional), a fin de brindar mayor oportunidad de participacion de los oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:27:14-04:00"}, {"id": "50035d9a3b2b77311245142bd84f6cca-1", "date": "2024-09-18T19:17:52-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 34. 6.1.6", "description": "\u201cAl menos 15.000.000 de canales digitales\u201dSolicitamos a la convocante que considere ajustar el requisito de \"Al menos 15.000.000 de canales digitales\" a un m\u00ednimo de 300.000 canales de procesamiento. La especificaci\u00f3n actual puede resultar excesiva en relaci\u00f3n con el costo referencial del equipo, limitando innecesariamente la participaci\u00f3n de proveedores y afectando la competitividad del proceso de licitaci\u00f3n. Un rango de 300.000 canales de procesamiento sigue siendo adecuado para proporcionar una calidad de imagen alta y cumplir con los est\u00e1ndares de desempe\u00f1o, mientras se ajusta mejor al presupuesto estipulado. Esto permitir\u00e1 una mayor flexibilidad en la selecci\u00f3n de equipos y contribuir\u00e1 a una mejor alineaci\u00f3n con el costo referencial propuesto.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:16:58-04:00"}, {"id": "d44fec48592b2ce82aa0d044820f0cd9-1", "date": "2024-09-18T19:30:30-04:00", "title": "ITEM 38 \u2013 Equipo de rayos x portatil", "description": "En el punto 3.3. donde dice \u201cLongitud total 1450 mm \u00b1 50 mm\u201d solicitamos amablemente a la convocante permita la cotizacion de equipos con longitud de al menos 1360 mm, considerando que esta solicitud no afecta en las prestaciones finales del equipo y permite la participaci\u00f3n de potenciales oferentes. Entonces solicitamos que el item quede de la siguiente manera: \u201cLongitud total 1350 mm \u00b1 50 mm\u201d.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:17:48-04:00"}, {"id": "a5ea712f4c54c6a925460a09d00dfbb3-1", "date": "2024-09-18T18:52:39-04:00", "title": "Item 52 \u2013 Monitor", "description": "Donde piden 52 2.7 Rango FHR: 50bpm \u00b1 3 a 250 bpm \u00b1 10. Solicitamos se puedan cotizar monitores fetales con Rango FHR: 50 bpm a 210 bpm, esta variaci\u00f3n no afecta a la performance del equipo.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:15:27-04:00"}, {"id": "3c453ab557b2b2753a2fe128d6230457-1", "date": "2024-09-17T16:36:11-04:00", "title": "Plan de entrega", "description": "En la P\u00e1gina 156 del PBC dice:\nLa entrega de los bienes se realizar\u00e1 de acuerdo al plan de entrega, El 100 % dentro de los 30 d\u00edas a partir de la firma del contrato en el Dto. de Suministros del HC San Lorenzo CP Lilian\nSuarez de Lunes a Viernes de 08: a 12:00 hs.\nConsiderando la situaci\u00f3n actual, bajante del rio, con su consecuente efecto en el retraso en el tr\u00e1nsito fluvial, solicitamos a la Convocante que extienda el plazo de entrega de por lo menos a 90 d\u00edas calendarios a partir de la firma del contrato, teniendo en cuenta que algunos Equipos deben ser importados.", "answer": "Remitirse a la respuesta de la consulta 1.", "dateAnswered": "2024-09-26T07:15:15-04:00"}, {"id": "3562418bdf340239508f4be433dbda40-1", "date": "2024-09-18T22:33:54-04:00", "title": "ID 443857 - \u00cdtem 34 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Transductor endocavitario con ancho de banda de 3MHz o menor a 12 MHz o mayor. Con \u00e1ngulo de apertura de al menos 240\u00b0. Compatible para uso de elastosonograf\u00eda. Cantidad: 01 (una) unidad por cada equipo\" solicitamos a la convocante modificar este punto a \"Transductor endocavitario con ancho de banda de 3.5MHz o menor a 10 MHz o mayor. Con \u00e1ngulo de apertura de al menos 240\u00b0. Compatible para uso de elastosonograf\u00eda. Cantidad: 01 (una) unidad por cada equipo\" dichos par\u00e1metros son est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos que modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:35:04-04:00"}, {"id": "3385b0d4efa7410b3bc6e58ae8806cf0-1", "date": "2024-09-18T19:30:35-04:00", "title": "ITEM 38 \u2013 Equipo de rayos x portatil", "description": "En el punto 3.5 donde dice \u201cPeso 260kg \u00b150 kg\u201d solicitamos amablemente a la convocante permita la cotizacion de equipos de peso mayor, como ser de 170 kg, considerando que esta caracter\u00edstica no afecta ni disminuye en las prestaciones finales del equipo y permite la participaci\u00f3n de potenciales oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:17:51-04:00"}, {"id": "c5fa242aeceb2ebedfba2d40a3ea82ba-1", "date": "2024-09-17T15:20:48-04:00", "title": "ITEM 34", "description": "4.6 donde dice: \nPosibilidad de visualizar im\u00e1genes almacenadas en el equipo a trav\u00e9s\nde la pantalla t\u00e1ctil para realizar comparaciones con la imagen en la\npantalla principal y seguimiento de estudios\nSolicitamos que este punto sea opcional para mayor participaci\u00f3n de oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:15:11-04:00"}, {"id": "4e1bf7d1366e0b65a9699aa9518afa50-1", "date": "2024-09-17T17:42:43-04:00", "title": "ITEM 34", "description": "En el \u00edtem 34 de las Especificaciones t\u00e9cnicas donde dice \u201cTransductor endocavitario con ancho de banda de 3MHz o menor a 12MHz o mayor. Con \u00e1ngulo de apertura de al menos 240\u00b0. Compatible para uso de elastosonograf\u00eda. Cantidad: 01 (una) unidad por cada equipo\u201d, solicitamos a la convocante la modificaci\u00f3n de este \u00edtem por \u201cTransductor endocavitario con ancho de banda de 4 MHz o menor a 12 MHz o mayor. Con \u00e1ngulo de apertura de al menos 120\u00b0. Cantidad: 01 (una) unidad por cada equipo\u201d, esta modificaci\u00f3n se alinea a los est\u00e1ndares de los transductores disponibles en el mercado, adem\u00e1s un \u00e1ngulo de apertura de 120\u00b0 ya ofrece un campo de visi\u00f3n m\u00e1s amplio, mejorando as\u00ed la cobertura en aplicaciones espec\u00edficas.", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:16:15-04:00"}, {"id": "2aa2e2978563b2afec598c25860457d3-1", "date": "2024-09-17T18:02:21-04:00", "title": "CONSULTA 4. ITEM 20 \u2013 CAMA EL\u00c9CTRICA PARA PACIENTE.", "description": "En el punto: \u201c5.4 Secci\u00f3n de ajuste de rodilla el\u00e9ctrico con rango de 0\u00b0 a 40\u00b0 +/-5\u00b0\u201d. Se solicita a la convocante permitir la participaci\u00f3n de camas el\u00e9ctricas con rango de 0\u00b0 a 35\u00b0 +/- 5\u00b0.", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:17:33-04:00"}, {"id": "d75bf3880f3dbade1d429b1a379331fe-1", "date": "2024-09-18T18:50:40-04:00", "title": "Item 9 \u2013 Caja de cirug\u00eda menor", "description": "Donde solicitan: Certificaci\u00f3n de la calidad de los instrum\u00e9ntales: DIM EN 10088T.1-3, EN ISO 7153-1 , y EN ISO 13485:2016, por favor aclarar que se requiere alguno de ellos.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:13:14-04:00"}, {"id": "112331f21f5095afb0b563924f836e8f-1", "date": "2024-09-25T17:21:43-04:00", "title": "Especificaciones Tecnicas", "description": "item 44- Maquina de Anestesia - Con medicion y aplicaci\u00f3n de los parametros respiratorios en pantalla LCD o LED color de 19 pulgadas \u00b1 2\". Solicitamos amablemente a la convocante ampliar el rango de tama\u00f1o de la pantalla del ventilador a 19\" \u00b1 4, para evitar limitar a oferentes que presentan equipo con mayores tama\u00f1o de pantalla, y en el rango inferior menor (15\") se considera suficiente para visualizar todos los parametros ajustables, valores monitorizados, 3 curvas en incluso 2 lazos. Adem\u00e1s la aceptaci\u00f3n del rango sugerido no limita las prestaciones del equipo", "answer": "Respondido en la Consulta 178.", "dateAnswered": "2024-09-26T14:24:47-04:00"}, {"id": "c790fc8a8578d7a62558ee92e5e12c75-1", "date": "2024-09-18T14:32:37-04:00", "title": "\u00cdTEM 33 ECOCARDI\u00d3GRAFO", "description": "Se solicita a la convocante admitir transductor sectorial o phased array de cristal \u00fanico para paciente adulto con ancho de banda de 1,5 a 4,5 MHz, para dar mayor participaci\u00f3n a oferentes.", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:23:05-04:00"}, {"id": "9029e55b7d53bc95e3c0be620641a345-1", "date": "2024-09-17T17:27:37-04:00", "title": "item 33", "description": "En relaci\u00f3n con el \u00edtem 33 de las Especificaciones T\u00e9cnicas, donde se solicita un \u201cDisco duro interno SSD de al menos 1TB\u201d, solicitamos que se modifique dicho requerimiento a \u201cDisco duro interno SSD de al menos 500GB\u201d, ya  que una capacidad de 500GB sigue siendo adecuada para las necesidades de almacenamiento del equipo, a la vez que permitir\u00eda reducir costos y fomentar una mayor participaci\u00f3n de oferentes, lo que beneficiar\u00eda tanto a la entidad convocante como al proceso de licitaci\u00f3n", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:15:23-04:00"}, {"id": "583d44d8a745fbc63d66931de2b70c8b-1", "date": "2024-09-18T22:22:38-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Para el \u00edtem 33 Donde dice \"Los equipos deber\u00e1n contar con 2 (dos) a\u00f1os de garant\u00eda desde la puesta en funcionamiento, e incluir como m\u00ednimo 1 (un) mantenimiento preventivo anual durante dicho periodo\" solicitamos a la convocante aclarar si la garant\u00eda solicitada incluye repuestos. Adem\u00e1s, solicitamos confirmar que la garant\u00eda no incluir\u00e1 los da\u00f1os que pudiere sufrir el equipo por errores de utilizaci\u00f3n, golpes y/o desgaste natural como son los transductores.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:28:27-04:00"}, {"id": "ce8bddef6354a05b004346e111d9a7ac-1", "date": "2024-09-18T19:30:48-04:00", "title": "ITEM 38 \u2013 Equipo de rayos x portatil", "description": "En el punto 3.6 donde dice \u201cAltura del foco con respecto al piso de 650 mm a al 1890 mm\u201d solicitamos amablemente a la convocante permita la cotizacion de equipos con rango de altura mayor, como ser a una altura de 650 mm o menor a 1900 mm o mayor con respecto al piso, y asi dar participaci\u00f3n de potenciales oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:17:54-04:00"}, {"id": "90cbee2b762b555c1d2b252e6d6c3ea5-1", "date": "2024-09-25T22:12:32-04:00", "title": "EETT ITEM 23. 2.2", "description": "En relaci\u00f3n con la especificaci\u00f3n de \"Respaldo rebatible y ajustable en forma manual con inclinaci\u00f3n de 0 a al menos 77\u00ba \u00b1 3\u00b0\". Solicitamos a la convocante considerar ajustar las especificaciones a un rango de inclinaci\u00f3n de 0 a 90\u00ba \u00b1 5\u00b0. Este ajuste ofrece una mayor versatilidad en la inclinaci\u00f3n del respaldo, lo que incrementa la comodidad y seguridad del paciente en diferentes posiciones, sin comprometer la funcionalidad o adaptabilidad del equipo en entornos cl\u00ednicos\u00a0exigentes.", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:25:45-04:00"}, {"id": "a3c4b1396d668f6484f50f565dee2942-1", "date": "2024-09-18T17:43:38-04:00", "title": "\u00cdtem 42 \u2013 Ventilador Pulmonar de Alta Complejidad", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 9.13 se solicita \u201cCon soporte de aspiraci\u00f3n: Preoxigenaci\u00f3n 2 [min]; tiempo post oxigenaci\u00f3n 1 [min]; nivel de ox\u00edgeno ajustable 21 - 100%. (con aspiraci\u00f3n abierta y l\u00ednea), suspensi\u00f3n de alarmas auditivas, y compensaci\u00f3n de flujo o presi\u00f3n durante aspiraci\u00f3n cerrada para evitar disminuci\u00f3n del PEEP.\u201d solicitamos a la Convocante pueda modificar este punto por \u201cCon soporte de aspiraci\u00f3n seg\u00fan tecnolog\u00eda del fabricante\u201d de manera a poder ajustarse a las tecnolog\u00edas disponibles en el mercado ya que varias marcas cuentan con esta funci\u00f3n, pero pudiendo diferenciarse en los tiempos de pre y post oxigenaci\u00f3n. Esta modificaci\u00f3n permite la participaci\u00f3n de m\u00e1s oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:34:06-04:00"}, {"id": "adba7c7290d366a29e9a4526c3ee42c0-1", "date": "2024-09-18T17:42:46-04:00", "title": "\u00cdtem 42 \u2013 Ventilador Pulmonar de Alta Complejidad", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 4.8 se solicita \u201cPausa Inspiratoria (Segundos). Apagado, 0,1 a 2,0\u201d solicitamos a la Convocante pueda modificar este punto por \u201cPausa Inspiratoria\u201d de manera a poder ajustarse a las tecnolog\u00edas disponibles en el mercado ya que varias marcas configuran este par\u00e1metro en porcentaje y no en segundos, con esta modificaci\u00f3n se estar\u00eda posibilitando la participaci\u00f3n de m\u00e1s oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:33:33-04:00"}, {"id": "9374b1054cabb6656ea677bbb17e95ec-1", "date": "2024-09-17T17:32:54-04:00", "title": "item 35 Ecografo port\u00e1til", "description": "4.6 Donde dice: Inicio r\u00e1pido del sistema inferior a 15 segundos \nSolicitamos diga: Inicio r\u00e1pido del sistema inferior a 20 segundos", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:15:47-04:00"}, {"id": "d7dd71cdfd6f7936fa8769a2d8062f5d-1", "date": "2024-09-18T19:30:59-04:00", "title": "ITEM 38 \u2013 Equipo de rayos x portatil", "description": "En el punto 3.10 donde dice \u201cRotaci\u00f3n del tubo alrededor de su eje + 90 grados min.,- 20 grados max.\u201d Solicitamos amablemente a la convocante permita la cotizacion de equipos con rotaci\u00f3n del tubo alrededor de su eje de +90\u00b0 como minimo y -20\u00b0 o m\u00e1s, y asi dar participaci\u00f3n de potenciales oferentes, considerando que este pedido no afecta en las prestaciones finales del equipo.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:18:01-04:00"}, {"id": "9a2d33fe72927ff02bbad0784174260d-1", "date": "2024-09-18T22:34:14-04:00", "title": "\u00cdtem 38 \u2013 Equipo de Rayos X M\u00f3vil", "description": "Para el \u00edtem 38 el PBC establece que el Plan de entrega de los bienes ser\u00e1: \"El 100 % dentro de los 30 d\u00edas a partir de la firma del contrato\" Favor solicitamos a la convocante modificar este punto a \"El 100 % dentro de los 120 d\u00edas posteriores a la recepci\u00f3n de la orden de compra por parte del proveedor\".  Lo solicitado obedece en su mayor\u00eda se trata de equipos cuya fabricaci\u00f3n se realiza tras un pedido al fabricante mediante orden de compra, y que posteriormente son importados, por lo que el plazo debe indefectiblemente incluir tiempo de transporte internacional y los procesos aduaneros realizados por terceros.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:35:06-04:00"}, {"id": "de9f279ed3389111b62e3481c099456a-1", "date": "2024-09-18T14:19:53-04:00", "title": "\u00cdtem 32 Citoscopio", "description": "Solicitamos reconsiderar el precio referencial fijado en este \u00edtem, considerando que no se ajusta al precio actual del mercado", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:22:40-04:00"}, {"id": "662fb2d520698aa14ec4c18eb7f6aa16-1", "date": "2024-09-25T14:32:11-04:00", "title": "\u00cdtem 1_ Aspirador de secreciones", "description": "\u00cdtem 1_ Aspirador de secreciones\nEn el punto 2.16 de las especificaciones t\u00e9cnicas la Convocante solicita:\n2 (dos) Frasco recolector graduado, en policarbonato de 5 litros como m\u00ednimo, con flotante mec\u00e1nico de seguridad, esterilizable en autoclave.\nSolicitamos respetuosamente a la Convocante permitir la cotizaci\u00f3n de equipos con:\n2 (dos) Frasco recolector graduado, en policarbonato de 3 litros como m\u00ednimo, con flotante mec\u00e1nico de seguridad, esterilizable en autoclave.", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:24:17-04:00"}, {"id": "3e71c95d2ca2232e621e2ed3b8316328-1", "date": "2024-09-25T18:26:27-04:00", "title": "\u00cdtem 55", "description": "Donde dice: \"Altura m\u00ednima 1,35 mts\" y \"Altura m\u00e1xima 2,25 mts\",\nSolicitamos a la convocante modificar los rangos a una altura m\u00ednima de 1,30 m \u00b1 5 cm y una altura m\u00e1xima de 2 m \u00b1 5 cm, de manera a permitir una mayor flexibilidad en las especificaciones y facilitar la participaci\u00f3n de m\u00e1s oferentes sin afectar la funcionalidad del equipo", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:25:30-04:00"}, {"id": "768451e9de2216a318008f00c50e40ac-1", "date": "2024-09-17T17:43:10-04:00", "title": "ITEM 35", "description": "En el \u00edtem 35 de las Especificaciones t\u00e9cnicas donde dice \u201c Pantalla t\u00e1ctil del tipo capacitivo para mejor tiempo de respuesta de los controles del usuario\u201d ,solicitamos a la convocante excluir este \u00edtem o clasificarlo como OPCIONAL. Esta modificaci\u00f3n facilitar\u00e1 la participaci\u00f3n de una mayor variedad de oferentes al permitir mayor flexibilidad en las ofertas y adaptarse a diferentes configuraciones tecnol\u00f3gicas, garantizando una competencia m\u00e1s abierta y efectiva", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:16:28-04:00"}, {"id": "fb6a3a45bc86ffc7489defe938bace76-1", "date": "2024-09-18T22:36:53-04:00", "title": "\u00cdtem 38 \u2013 Equipo de Rayos X M\u00f3vil", "description": "Donde dice \"Tiempo para visualizaci\u00f3n de la imagen de cinco segundos o menor\" solicitamos a la convocante modificar este punto a \"Tiempo para visualizaci\u00f3n de la imagen de seis segundos o menor.\" La diferencia solicitada es m\u00ednima, adem\u00e1s, dicho par\u00e1metro es est\u00e1ndar en la mayor\u00eda de los equipos de rayos x m\u00f3vil y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos se actualice este punto a fin de tener la participaci\u00f3n de las marcas con reconocida representaci\u00f3n y comprobada calidad en el mercado local e internacional. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 38 est\u00e1n direccionadas a la marca SHIMADZU modelo MobileArt Eco MUX-10, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:35:44-04:00"}, {"id": "ec2999aa458078186dfb4fb5ea2bf596-1", "date": "2024-09-14T11:07:05-04:00", "title": "Especificaciones T\u00e9cnicas - \u00cdtem 42) Ventilador Pulmonar de Alta Complejidad", "description": "DONDE DICE:\n\n9.6 Pantalla LCD de 19 \u00b1 2\". Perilla o botones selectores para ajuste de valores\n9.11 Monitorizaci\u00f3n de SpO2 en pantalla del ventilador\n9.13 Con soporte de aspiraci\u00f3n: Preoxigenaci\u00f3n 2 [min]; tiempo post oxigenaci\u00f3n 1 [min]; nivel de ox\u00edgeno ajustable 21 - 100%. (con aspiracion abierta y l\u00ednea), suspension de alarmas auditivas, y compensacion de flujo o presi\u00f3n durante aspiracion cerrada para evitar disminuci\u00f3n del PEEP.\n\nFavor modificar a: \n\n9.6 Pantalla LCD de 19 \u00b1 2\". Perilla o botones selectores para ajuste de valores. (OPCIONAL)\n9.11 Monitorizaci\u00f3n de SpO2 en pantalla del ventilador. (OPCIONAL)\n9.13 Con soporte de aspiraci\u00f3n: Preoxigenaci\u00f3n 2 [min]; tiempo post oxigenaci\u00f3n 1 [min]; nivel de ox\u00edgeno ajustable 21 - 100%. (con aspiracion abierta y l\u00ednea), suspension de alarmas auditivas, y compensacion de flujo o presi\u00f3n durante aspiracion cerrada para evitar disminuci\u00f3n del PEEP. (OPCIONAL)\n\nLo solicitado es por el motivo que sokn condiciones t\u00e9cnicas no indispensables para el funcionamiento del equipo, no afecta en sus prestaciones, y con la modificaci\u00f3n se permitir\u00e1 mayor concurrencia y posibilidad de contar con mayor cantidad de ofertas y marcas ofertadas, y como consecuencia, aumentar las posibilidades de mejores condiciones de contrataci\u00f3n para la entidad, en concordancia con los principios de econom\u00eda, eficacia y eficiencia y de igualdad y libre competencia.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:14:39-04:00"}, {"id": "86cbb3bc43daf4fd5bd1c4328c9a450f-1", "date": "2024-09-18T19:15:16-04:00", "title": "item 20 Cama electrica", "description": "En el Item 20 Cama el\u00e9ctrica a para paciente: En el punto 5.4 Solicitan Secci\u00f3n de ajuste de rodilla el\u00e9ctrico con Rango de 0 a 40\u00ba \u00b1 5\u00b0. Este punto solicitamos a la convocante poder cotizar con rango de 0 a 35\u00b0+/-5 cm", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:16:48-04:00"}, {"id": "d5836d7cd243765c6d2dee5977c34ae4-1", "date": "2024-09-14T11:07:21-04:00", "title": "Especificaciones T\u00e9cnicas - \u00cdtem 42) Ventilador Pulmonar de Alta Complejidad", "description": "DONDE DICE:\n\n10.12 Pantalla secundaria para control y monitorizaci\u00f3n del ventilador de 19\" \u00b1 2\". Conexi\u00f3n a la pantalla principal al\u00e1mbrica o inal\u00e1mbrica. Una (1) unidad por la totalidad de equipos incluyendo el carro para la pantalla secundaria\n10.13 Se deber\u00e1n incluir 2 (dos) conjuntos de cartuchos exhalatorios o filtro o cassettes exhalatorio o v\u00e1lvula exhalatoria o sensor de flujo o cualquier componente a ser cambiados por cada paciente para su limpieza, desinfecci\u00f3n o esterilizaci\u00f3n por cada equipo.\n\nFavor modificar a: \n\n10.12 Pantalla secundaria para control y monitorizaci\u00f3n del ventilador de 19\" \u00b1 2\". Conexi\u00f3n a la pantalla principal al\u00e1mbrica o inal\u00e1mbrica. Una (1) unidad por la totalidad de equipos incluyendo el carro para la pantalla secundaria. (OPCIONAL)\n10.13 Se deber\u00e1n incluir 2 (dos) conjuntos de cartuchos exhalatorios o filtro o cassettes exhalatorio o v\u00e1lvula exhalatoria o sensor de flujo o cualquier componente a ser cambiados por cada paciente para su limpieza, desinfecci\u00f3n o esterilizaci\u00f3n por cada equipo. (OPCIONAL\n\nLo solicitado es por el motivo que sokn condiciones t\u00e9cnicas no indispensables para el funcionamiento del equipo, no afecta en sus prestaciones, y con la modificaci\u00f3n se permitir\u00e1 mayor concurrencia y posibilidad de contar con mayor cantidad de ofertas y marcas ofertadas, y como consecuencia, aumentar las posibilidades de mejores condiciones de contrataci\u00f3n para la entidad, en concordancia con los principios de econom\u00eda, eficacia y eficiencia y de igualdad y libre competencia.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:14:42-04:00"}, {"id": "156c659ffef73e0cb47a8452ba56475d-1", "date": "2024-09-23T14:58:07-04:00", "title": "SOPORTE TECNICO", "description": "ITEM 34 en el punto 9.6 Soporte t\u00e9cnico durante el tiempo de duraci\u00f3n de la garant\u00eda. Presentar declaraci\u00f3n jurada. \nSolicitamos a la convocante pueda ser modificada este criterio de la siguiente manera: Soporte t\u00e9cnico durante el tiempo de duraci\u00f3n de la garant\u00eda del bien ofertado.  Presentar declaraci\u00f3n jurada.", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:24:07-04:00"}, {"id": "6f9aa772b01e876e3316860f19895a0c-1", "date": "2024-09-18T19:14:48-04:00", "title": "Item 56 Incubadora + Servocuna", "description": "En el \u00cdtem 56 Solicitan Incubadora +Servocuna: Solicitamos a la convocante poder cotizar Incubadora o Servocuna ya que estas especificaciones t\u00e9cnicas est\u00e1n dirigidas \u00fanicamente a la marca Fanem con su modelo duetto 2386", "answer": "El equipo solicitado corresponde a un equipo hibrido comercializado en nuestro pais por varias marcas. Refiere a una nueva tecnologia solicitada por el servicio.", "dateAnswered": "2024-09-26T08:16:26-04:00"}, {"id": "471073e7ae00081d495cc8feb45597d6-1", "date": "2024-09-18T19:30:53-04:00", "title": "ITEM 38 \u2013 Equipo de rayos x portatil", "description": "En el punto 3.8 donde dice \u201cRotaci\u00f3n de la columna portatubo \u00b1180 grados \u00b1 5\u00b0\u201d solicitamos amablemente a la convocante permita la cotizacion de equipos con rotaci\u00f3n de al menos +/-120\u00b0, y asi dar participaci\u00f3n de potenciales oferentes, considerando que este pedido no afecta en las prestaciones finales del equipo.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:17:56-04:00"}, {"id": "fdfbf732cf2607096af6076702e09144-1", "date": "2024-09-18T18:47:38-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 33. Punto 2.2", "description": "\"Pantalla t\u00e1ctil integrada para acceso al men\u00fa secundario de 13 o superior con ajuste de brillo y resoluci\u00f3n de al menos 1920x1080, que permita el manejo interactivo del men\u00fa, para acceso a modos de operaci\u00f3n, aplicaciones y configuraciones\". Solicitamos a la convocante que aclare si la medida de 13, mencionada para la pantalla t\u00e1ctil integrada, est\u00e1 especificada en cent\u00edmetros o pulgadas. En caso de estar en pulgadas, solicitamos que se considere establecer un rango entre 10 y 13 pulgadas, lo que permitir\u00eda mayor flexibilidad en la oferta sin comprometer la funcionalidad del equipo, facilitando as\u00ed la participaci\u00f3n de m\u00e1s oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:12:48-04:00"}, {"id": "88c8ae4f522e69d6efbeb87a9206e3a1-1", "date": "2024-09-18T17:43:11-04:00", "title": "\u00cdtem 42 \u2013 Ventilador Pulmonar de Alta Complejidad", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 9.6 se solicita \u201cPantalla LCD de 19 \u00b1 2\"\u201d solicitamos a la Convocante pueda modificar este punto por \u201cPantalla LCD de 17 \u00b1 2\"\u201d de manera a ajustarse a los valores est\u00e1ndares del mercado y no limitar los mismos. La modificaci\u00f3n sugerida no afecta en lo m\u00e1s m\u00ednimo la funcionalidad del equipo. Esta modificaci\u00f3n permite la participaci\u00f3n de m\u00e1s oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:34:03-04:00"}, {"id": "05b2a3bb5ba59a1d6825c20e86a911fc-1", "date": "2024-09-13T12:15:27-04:00", "title": "\u00cdtem 51  Microscopios de fluorescencia", "description": "\u00cdtem 51  Microscopios de fluorescencia. Establece el PBC en el punto 3.7: torreta universal de 7 posiciones como BF, DF. PH1, PH2, PH3, FL Y 2X. \nFavor considerar modificar la especificaci\u00f3n con - m\u00ednimo torreta de 5 posiciones, para BF,PH1,PH2,PH3 - Considerando el precio referencial, ya que 7 posiciones aumentar\u00eda demasiado el costo del equipo.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:09:18-04:00"}, {"id": "d7ae6b62cb9c53064810532043cdc14e-1", "date": "2024-09-17T17:42:56-04:00", "title": "ITEM 35", "description": "En el \u00edtem 35 de las especificaciones t\u00e9cnicas donde dice \u201cMonitor de alta resoluci\u00f3n LED Wide Screen Full HD de 18 \u00b13\", solicitamos a la convocante la modificaci\u00f3n de este \u00edtem por \u201cMonitor de alta resoluci\u00f3n LED de alta resoluci\u00f3n de 15\u201d o mejor\u201d, Esta modificaci\u00f3n est\u00e1 alineada con los est\u00e1ndares del mercado para equipos port\u00e1til y permitir\u00e1 una mayor apertura a potenciales oferentes, promoviendo una competencia m\u00e1s amplia y evitando la limitaci\u00f3n a una sola marca", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:16:22-04:00"}, {"id": "cbc702fbd215dc032830f35090d8ceee-1", "date": "2024-09-18T17:52:26-04:00", "title": "\u00cdTEM 35 EC\u00d3GRAFO", "description": "4.12 Se solicita a la convocante admitir  que El equipo debe trabajar con rangos de frecuencias de 1.2- 23 MHz, para dar mayor participaci\u00f3n a oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:11:33-04:00"}, {"id": "a27c1e9fcfa689256694531aa31482e9-1", "date": "2024-09-18T22:28:16-04:00", "title": "ID 443857 - \u00cdtem 34 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Memoria CINE de al menos 9000 cuadros\" solicitamos a la convocante modificar este punto a \"Memoria CINE de al menos 2.700 cuadros o mayor\" lo solicitado obedece a que, la finalidad de esta caracter\u00edstica es revisar breves instantes del estudio y evaluar el movimiento del tejido para lo cual el valor solicitado es m\u00e1s que suficiente.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:33:43-04:00"}, {"id": "0742dc81659b541878e7713e6088c0ea-1", "date": "2024-09-18T18:51:02-04:00", "title": "Item 14 \u2013 Caja de cirug\u00eda general", "description": "Solicitamos respetuosamente se eliminen los puntos 14.2.6 1 Trocar con Camisa N\u00b0 16 y 14.2.7 1 Trocar con Camisa N\u00b0 18, considerando que son descartables", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:13:43-04:00"}, {"id": "1c3b4a7ab758797afc0822f239f2ae58-1", "date": "2024-09-18T18:52:02-04:00", "title": "Item 36 \u2013 Electrocardiografo", "description": "36 4.6 Capacidad de transferir datos mediante USB, Ethernet y conexi\u00f3n a la\nred inal\u00e1mbrica como m\u00ednimo. Solicitamos que la conexi\u00f3n a la red inal\u00e1mbrica sea considerada opcional, de manera a resguardar los datos confidenciales de los pacientes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:14:26-04:00"}, {"id": "d209a95357b98ce4befd3055153d8bb3-1", "date": "2024-09-18T17:01:36-04:00", "title": "ITEM 1 1 2.5 Bot\u00f3n para el ajuste de la presi\u00f3n de vac\u00edo", "description": "Para este punto se solicita a la convocante aceptar un Mando giratorio de regulaci\u00f3n de vac\u00edo preciso y estable.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:27:55-04:00"}, {"id": "9372e3dea80c2d26105fe69417ea46bb-1", "date": "2024-09-18T14:20:30-04:00", "title": "\u00cdtem 32 Citoscopio", "description": "4.4 Capacitaci\u00f3n a usuarios sobre el funcionamiento del equipo y capacitaci\u00f3n t\u00e9cnica al personal t\u00e9cnico del Departamento de Electromedicina. Presentar declaraci\u00f3n jurada.\nSolicitamos excluir este requisito, considerando que no se trata de un equipo", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:22:58-04:00"}, {"id": "5264cc749ae561919b9cc13543869337-1", "date": "2024-09-18T14:52:44-04:00", "title": "Garant\u00eda de los equipos", "description": "En la Pg. 98 del PBC, \u00edtem 37 punto 3.5 establece que: \u201cLos equipos deber\u00e1n contar con 2 (dos) a\u00f1os de garant\u00eda desde la puesta en funcionamiento, e incluir como m\u00ednimo 1 (un) mantenimiento preventivo anual durante dicho periodo. Presentar declaraci\u00f3n Jurada\u201d, se solicita amablemente a convocante detallar, que la garant\u00eda solo cubre defectos de F\u00e1brica no as\u00ed problemas ocasionados por mala utilizaci\u00f3n por parte del operario y da\u00f1os por factores externos (sistema de agua tratada, alimentaci\u00f3n el\u00e9ctrica, entre otros).", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:24:07-04:00"}, {"id": "463aaf70ad7487d41e0ef6ab59c43402-1", "date": "2024-09-25T18:25:52-04:00", "title": "\u00cdtem 53", "description": "En los \u00edtems \"7.4 y 7.6 - Frecuencia de muestreo 100 Hz \u00b110% por canal, Rango \u00b1400 \u03bcV \u00b110%\", y \"Resoluci\u00f3n de 60 nV o mejor\", solicitamos a la convocante considerar estos requisitos como OPCIONALES, permitiendo as\u00ed una mayor participaci\u00f3n de oferentes con productos que ofrezcan alternativas viables", "answer": "Respondido en la Consulta 249.", "dateAnswered": "2024-09-26T14:25:22-04:00"}, {"id": "0cb48d28ed4a7df32defd9f3f3873259-1", "date": "2024-09-18T22:37:03-04:00", "title": "\u00cdtem 38 \u2013 Equipo de Rayos X M\u00f3vil", "description": "Donde dice \"Sistema de detecci\u00f3n autom\u00e1tica de disparo\" solicitamos a la convocante aclarar a qu\u00e9 funcionalidad se refiere lo solicitado en este punto.", "answer": "Se aclara que la deteccion automatica del disparo. Se refiere a que no existe ningun medio de sincronizacion entre el generador de rayos x y el panel de deteccion, lo cual permite su utilizacion como un CR.", "dateAnswered": "2024-09-26T08:35:47-04:00"}, {"id": "8fbc349fadc9f0c862270d6684ff2808-1", "date": "2024-09-18T19:31:03-04:00", "title": "ITEM 38 \u2013 Equipo de rayos x portatil", "description": "En el punto 6.2 donde dice \u201cMatriz de detectores 2500 x 3000 pixeles o mejor\u201d solicitamos amablemente a la convocante permita la cotizacion de equipos con matriz de detectores de al menos 2430 x 3000 pixeles o mejor, y asi dar participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:18:04-04:00"}, {"id": "07a6b708e8cdd150ac7f72acfb04825f-1", "date": "2024-09-17T17:27:55-04:00", "title": "item 33", "description": "En el Item 33 de las Especificaciones t\u00e9cnicas donde se solicita \u201cTransductor sectorial o phased array de cristal \u00fanico para paciente adulto con ancho de banda de 1 MHz o menor a 5 MHz o mayor. con Campo de apertura de al menos 90\u00b0. Que alcance una profundidad de escaneo de al menos 35cm o mayor. Cantidad: 01 unidad.\u201d Solicitamos a la convocante modificar este por \u201cTransductor sectorial o phased array de cristal \u00fanico para paciente adulto con ancho de banda de 1.5 MHz o menor a 5 MHz o mayor. Con Campo de apertura de al menos 85\u00b0. Que alcance una profundidad de escaneo de al menos 35cm o mayor. Cantidad: 01 unidad.\u201d, esta modificaci\u00f3n ampliar\u00e1 el rango de especificaciones, promoviendo una mayor participaci\u00f3n de oferentes y beneficiar\u00e1 a la convocante al facilitar un proceso de adquisici\u00f3n m\u00e1s competitivo y accesible.", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:15:39-04:00"}, {"id": "c96307f801458954eace8f8283a1952f-1", "date": "2024-09-25T17:41:21-04:00", "title": "\u00cdtem 42", "description": "Donde dice: \"Nebulizador con tecnolog\u00eda de malla vibratoria o ultras\u00f3nica.\"\nSolicitamos a la convocante cambiarlo a \"Nebulizador con tecnolog\u00eda de malla vibratoria, ultras\u00f3nica o neum\u00e1tica\" para ampliar la participaci\u00f3n de m\u00e1s oferentes que cumplan con la especificaci\u00f3n, asegurando un proceso competitivo.", "answer": "Respondido en la Consulta 71.", "dateAnswered": "2024-09-26T14:25:10-04:00"}, {"id": "c3e998cd70e642cfbd0e8c59b66ecc07-1", "date": "2024-09-18T17:44:58-04:00", "title": "\u00cdtem 45 \u2013 M\u00e1quina de Anestesia", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 5.21 se solicita \u201cMedici\u00f3n de agentes anest\u00e9sicos (Sevoflurano, Isoflurano, Halotano, Enflurano y Desflurano), fracci\u00f3n inspirada y fracci\u00f3n espirada. Medici\u00f3n en mL de cada agente anest\u00e9sico\u201d solicitamos a la Convocante pueda modificar este punto por \u201cMedici\u00f3n de agentes anest\u00e9sicos (Sevoflurano, Isoflurano, Halotano, Enflurano y Desflurano), fracci\u00f3n inspirada y fracci\u00f3n espirada.\u201d. La gran mayor\u00eda de las marcas mundiales de m\u00e1quinas de anestesias miden sus niveles de agentes anest\u00e9sicos en porcentajes, por lo que solicitar la medici\u00f3n en mL ser\u00eda limitar la participaci\u00f3n de todas ellas, solicitamos esta modificaci\u00f3n de manera a permitir un mayor n\u00famero de oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:10:35-04:00"}, {"id": "4e17fbbcf772748ce159e53851028837-1", "date": "2024-09-18T17:42:52-04:00", "title": "\u00cdtem 42 \u2013 Ventilador Pulmonar de Alta Complejidad", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 5.7 se solicita \u201cTerapia O2 de bajo y alto flujo o Terap\u00eda de O2 o similar con rango (l/min) de 1 a 65 \u00b1 5 l/min.\u201d solicitamos a la Convocante pueda modificar este punto por \u201cTerapia O2 de bajo y alto flujo o Terap\u00eda de O2 o similar con rango (l/min) de 2 o menor a 65 o mayor\u201d de manera a poder ajustarse a las tecnolog\u00edas disponibles en el mercado y no limitar la participaci\u00f3n de posibles oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:33:38-04:00"}, {"id": "87dd9337e20533ffccebceb20de8ef36-1", "date": "2024-09-18T19:43:43-04:00", "title": "Item 42 Ventilador Pulmonar", "description": "En el punto 4.11 donde dice \u201cFrecuencia respiratoria (bpm). L\u00edmite inferior 1 o menor y l\u00edmite superior 150 o mayor\u201d solicitamos a la convocante permita la cotizacion de equipos con rango de l\u00edmite superior de 50 o mayor, esto considerando que es el valor usual para aplicaciones Clinicas y asi tambien para dar participaci\u00f3n de potenciales oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:18:22-04:00"}, {"id": "41c7ec24778578d5fbc8b9a7ff3b023c-1", "date": "2024-09-18T19:14:41-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 33. 6.3", "description": "\u201cTransductor sectorial o phased array pedi\u00e1trico con ancho de banda de 2 MHz o menor a 9 MHz o mayor\u201d Solicitamos a la convocante que considere ajustar los requisitos para el \"Transductor sectorial o phased array pedi\u00e1trico\" para que el rango de ancho de banda sea de 2 MHz o menor a 7 MHz o mayor. Un rango de 2 MHz a 7 MHz ofrece una mayor flexibilidad en la selecci\u00f3n de transductores adecuados para una variedad de aplicaciones pedi\u00e1tricas, permitiendo una adaptaci\u00f3n m\u00e1s precisa a diferentes tipos de ex\u00e1menes y condiciones cl\u00ednicas. Esto no solo facilita la elecci\u00f3n de equipos que se ajusten mejor a las necesidades espec\u00edficas de los pacientes pedi\u00e1tricos, sino que tambi\u00e9n asegura que el equipo pueda proporcionar im\u00e1genes de alta calidad para un amplio rango de frecuencias, optimizando as\u00ed el rendimiento y la utilidad en entornos cl\u00ednicos variados", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:16:17-04:00"}, {"id": "fd2661f0eddec54f9a3d6f670742f1ea-1", "date": "2024-09-17T17:49:58-04:00", "title": "ITEM 35", "description": "En el \u00edtem 35 de las Especificaciones t\u00e9cnicas donde dice \u201c Al menos 4.000.000 de canales de procesamiento digital\u201d, solicitamos a la convocante modificar este \u00edtem por \u201cAl menos 1.000.00 de canales de procesamiento digital\u201d, este ajuste se alinea con el est\u00e1ndar de equipos modulares de la gama solicitada y facilitar\u00e1 una mayor participaci\u00f3n de potenciales oferentes, promoviendo as\u00ed un proceso de adquisici\u00f3n m\u00e1s inclusivo y competitivo.", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:17:04-04:00"}, {"id": "4bc1d8406415e4d4ba7d4239d6ed2c6c-1", "date": "2024-09-18T14:17:50-04:00", "title": "\u00cdtem N\u00ba 7 Caja de cirug\u00eda", "description": "Solicitamos excluir los sub items, orden o puntos: 2.24, 2.25, 2.26, 2.27, 2.28, 2.31, 2.32 y 2.33 considerando a que no corresponden a especificaciones de la caja solicitada en este \u00edtem", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:19:29-04:00"}, {"id": "3b36117d8c603c83d00947d83df46b08-1", "date": "2024-09-18T18:56:45-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 33. Punto 5.2", "description": "\"C\u00e1lculo de velocidades longitudinal, radial, circunferencial y Strain Global con despliegue autom\u00e1tico de ojo de buey\" sea un requisito obligatorio en lugar de opcional. Dado que se trata de un ecocardiografo, estas funcionalidades son cruciales para un an\u00e1lisis completo y preciso de la mec\u00e1nica card\u00edaca. La inclusi\u00f3n de estos c\u00e1lculos como requisitos obligatorios asegura que los equipos propuestos est\u00e9n equipados con las capacidades necesarias para una evaluaci\u00f3n exhaustiva y detallada, cumpliendo as\u00ed con los est\u00e1ndares de alta gama para aplicaciones cardiol\u00f3gicas avanzadas.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:16:12-04:00"}, {"id": "67359eeb2d86e4afdfe8150d75010e88-1", "date": "2024-09-25T17:08:21-04:00", "title": "Especificaciones Tecnicas", "description": "\"Item 42 - Ventilador pulmonar de alta complejidad. Donde dice \"\"        Pantalla LCD de 19 \u00b1 2\"\".\nPerilla o botones selectores para ajuste de valores.\"\" Solicitamos amablemente a la convocante ampliar el rango del tama\u00f1o de la pantalla de manera a aceptar equipos con mejores prestaciones. Sugerimos tama\u00f1o LCD 19\"\" \u00b1 4\"\", adem\u00e1s la aceptaci\u00f3n de esta sugerencia no desvia sustancialmente las prestaciones del equipo y no limitar a ciertas marcas u oferentes que presentan equipos que condicen con el tama\u00f1o limitado \"", "answer": "Respondido en la Consulta 23.", "dateAnswered": "2024-09-26T14:24:45-04:00"}, {"id": "fc2d900584ab70433605da737821ae9d-1", "date": "2024-09-18T17:51:32-04:00", "title": "\u00cdTEM 33 ECOCARDI\u00d3GRAFO", "description": "Se solicita a la convocante admitir  Profundidad de imagen desde 1.5-40cm, para dar mayor participaci\u00f3n a oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:10:45-04:00"}, {"id": "0bad85bd971f4e36879ddcd601570cea-1", "date": "2024-09-18T17:40:34-04:00", "title": "\u00cdtem 53 \u2013 Monitor Multiparam\u00e9trico", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 4.1 solicitan \u201cPantalla de 15 pulgadas como m\u00ednimo\u201d, solicitamos a la convocante modificar este punto por \u201cPantalla de 12 pulgadas como m\u00ednimo\u201d, la modificaci\u00f3n sugerida no implica una variaci\u00f3n en la funcionalidad del equipo.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:28:08-04:00"}, {"id": "34b4a27e569bddaebdc71ecfc9c83449-1", "date": "2024-09-18T22:43:18-04:00", "title": "\u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \"El sistema debe ser capaz de reconocer y medir la fracci\u00f3n de eyecci\u00f3n autom\u00e1ticamente sin necesidad de marcar puntos dentro de la imagen\" solicitamos a la convocante considerar este punto como OPCIONAL debido a que esta caracter\u00edstica encarece significativamente el precio referencial del ec\u00f3grafo requerido. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:29-04:00"}, {"id": "fda10fe358c547900e03114fca408c05-1", "date": "2024-09-18T18:50:28-04:00", "title": "Plan de entrega de los bienes", "description": "Con respecto al plazo de entrega: solicitamos que los equipos sean entregados entre 90 y 120 d\u00edas considerando que tienen configuraciones particulares y deben ser importados.", "answer": "Remitirse a la respuesta de la consulta 1.", "dateAnswered": "2024-09-26T08:13:03-04:00"}, {"id": "5f7e83f8ddf17c0714010063edf2ba72-1", "date": "2024-09-18T20:19:01-04:00", "title": "ESPECIFICACIONES TECNICAS - \u00cdtems 37", "description": "En el punto 2.4 \u201cPilas tipo C\u201d, se solicita al convocante modificar el requerimiento a bater\u00eda de iones de litio recargable, ya que las bater\u00edas de iones de litio suelen tener una mayor capacidad de almacenamiento de energ\u00eda, lo que significa que pueden alimentar el laringoscopio durante m\u00e1s tiempo entre recargas y   son recargables, lo que reduce el desperdicio y los costos a largo plazo.", "answer": "La consulta no corresponde al item.", "dateAnswered": "2024-09-26T08:18:27-04:00"}, {"id": "a53182f40abc72701974048df58bd5e4-1", "date": "2024-09-25T14:29:06-04:00", "title": "\u00cdtem 4_ Biometro", "description": "\u00cdtem 4_ Biometro\nEn el numeral 4.2 de las especificaciones t\u00e9cnicas la Convocante solicita:\nBiometro \u00f3ptico por fuente de barrido l\u00e1ser con Topograf\u00eda (Swept Source laser)\nEn este punto solicitamos a la Convocante permita la presentaci\u00f3n con la denominaci\u00f3n de cada fabricante, de tal manera que el PBC quede redactado de la siguiente manera: \nBiometro \u00f3ptico por fuente de barrido l\u00e1ser con Topograf\u00eda (Swept Source laser) o denominaci\u00f3n de cada fabricante.", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:24:09-04:00"}, {"id": "ae1570c811cf7555810f1d4549ca56c3-1", "date": "2024-09-25T17:29:06-04:00", "title": "ESPECIFICACIONES TECNICAS - ITEM 21. 5.2", "description": "Donde se solicita un \"Rango de 0\u00b0 a 80\u00ba \u00b1 5\u00b0\", solicitamos a la convocante considerar ajustar el rango a 80\u00b0 \u00b1 10\u00b0. Un rango m\u00e1s amplio de inclinaci\u00f3n ofrece mayor versatilidad en el posicionamiento del paciente, facilitando el ajuste preciso a las necesidades cl\u00ednicas de cada caso. Esta flexibilidad mejora la comodidad del paciente y permite una mayor adaptabilidad en los cuidados cr\u00edticos, sin comprometer la funcionalidad del equipo.", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:24:56-04:00"}, {"id": "2457a5aa99487965e8088ce07dbf428a-1", "date": "2024-09-18T10:27:55-04:00", "title": "/*Requisitos documentales para evaluar el criterio de capacidad t\u00e9cnica", "description": "12: Declaracion Jurada de que la empresa adjudicada se compromete a:... -Que los mantenimientos se realizaran seg\u00fan los est\u00e1ndares de la marca y del equipo ofertado, presentar copia el protocolo de mantenimiento. Favor aclarar a que se refieren con copia del protocolo de mantenimiento.", "answer": "Se refiere al protocolo de mantenimiento preventivo que establece el fabricante.", "dateAnswered": "2024-09-26T07:17:53-04:00"}, {"id": "f41cc7fc90b324c37bb4d55ff0db0862-1", "date": "2024-09-19T06:56:14-04:00", "title": "item 42", "description": "6.10 Concentraci\u00f3n de O2 inspirado (FiO2) Del 18 al 21 %vol., solicitamos que este punto sea eliminado", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:37:00-04:00"}, {"id": "046305a77e40d05b5bde689ee4ac3190-1", "date": "2024-09-18T22:02:55-04:00", "title": "Item 42 Ventilador Pulmonar", "description": "En el punto 6.27 donde dice \u201cPresi\u00f3n de Conduccion o Driving Pressure (PDRIVING), Driving Pressure Estimada (PDRIVING-EST)\u201d solicitamos amablemente a la convocante permita la cotizaci\u00f3n como opci\u00f3n alternativa del par\u00e1metro Distensibilidad Est\u00e1tica Calculada (Cest) que por definici\u00f3n es la relaci\u00f3n Vtinsp / (Pplt \u2013 PEEP), sabiendo que por definici\u00f3n Driving Pressure es Pplt \u2013 PEEP. Ambos par\u00e1metros aplican para el mismo sentido de monitorizaci\u00f3n y diagnostico; ya que uno le contiene al otro (Cest contiene como valor a PDRIVING). Adem\u00e1s, se dar\u00e1 apertura a la participaci\u00f3n de potenciales oferentes, por todo lo expuesto solicitamos que el \u00edtem quede de la siguiente manera: \u201cPresi\u00f3n de Conduccion o Driving Pressure (PDRIVING), Driving Pressure Estimada (PDRIVING-EST) \u00f3 Distensibilidad Est\u00e1tica Calculada (Cest)\u201d.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:27:51-04:00"}, {"id": "9e5e745fbb3b7318cde87d557143665d-1", "date": "2024-09-18T11:13:19-04:00", "title": "Item 9 \u2013 Caja de Cirug\u00eda Menor", "description": "Item 9 \u2013 Caja de Cirug\u00eda Menor.\nEn una parte de las especificaciones t\u00e9cnicas dice: Todos los instrumentales son de material de acero Inoxidable quir\u00fargico, demostrado por Certificados de calidad de la CE e ISO 13485.\nSolicitamos al convocante permita cotizar certificado de calidad de la CE e ISO 13485 (al menos una de ellas).", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:18:06-04:00"}, {"id": "feddb6621c532fac53179f56cd0eefbc-1", "date": "2024-09-18T22:51:08-04:00", "title": "CAPACITACION", "description": "ITEM 34 Punto 9.4 Capacitaci\u00f3n a usuarios sobre el funcionamiento del equipo y capacitaci\u00f3n t\u00e9cnica al personal t\u00e9cnico del Departamento de Electromedicina. Presentar declaraci\u00f3n jurada.\nSe solicita amablemente a la convocante especificar la cantidad de horas necesarias para realizar el entrenamiento. Sin embargo, se sugiere que para cumplir con dicho punto es m\u00e1s que suficiente 8 horas por 3 d\u00edas y de esta manera cubrir con todos los puntos que pueden realizar los usuarios.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:49-04:00"}, {"id": "5defee9f6d5b9207dd6b06d3feb3576c-1", "date": "2024-09-18T17:42:40-04:00", "title": "\u00cdtem 16 \u2013 Monitor Multiparam\u00e9trico", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 7.7 se solicita \u201c(dos) sistemas EEG de 8 canales por la totalidad de equipos.\u201d solicitamos a la Convocante pueda modificar este punto por \u201c(dos) sistemas EEG de al menos 8 derivaciones por la totalidad de equipos.\u201d de manera a poder ajustarse a las tecnolog\u00edas disponibles en el mercado y posibilitando la participaci\u00f3n de m\u00e1s oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:33:31-04:00"}, {"id": "141de88c4377477c31c018aac452623b-1", "date": "2024-09-18T22:35:30-04:00", "title": "\u00cdtem 38 \u2013 Equipo de Rayos X M\u00f3vil", "description": "Donde dice \"Longitud del brazo portatubo 650 a 1000 mm\u00b1 10\" solicitamos a la convocante indicar si esta medida se refiere a la longitud de la columna (extensi\u00f3n horizontal) o la longitud de movimiento vertical.", "answer": "Se aclara que esta medida se refiere a la extension horizontal del brazo porta tubo, en su extension minima y maxima posible.", "dateAnswered": "2024-09-26T08:35:20-04:00"}, {"id": "8fa5fc7d3b891e1dfbc7a08ba8b2cb21-1", "date": "2024-09-25T16:21:19-04:00", "title": "\u00cdtem 40 Estufa de secado", "description": "1.\tSe le consulta amablemente a la convocante que indique la temperatura de trabajo, ya que dentro de este rango de 10 a 310\u00b0C puede haber varios tipos de variaciones, desde +/- 0.5\u00b0C hasta +/-15\u00b0C\n2.\tSe consulta si la estabilidad de 0.4\u00b0C se considera como la variaci\u00f3n dentro del invernadero?\n3.\tCon relaci\u00f3n al requisito de Alarma activada cuando ocurre desviaci\u00f3n, sistema de protecci\u00f3n contra sobrecalentamiento, esta alarma ser\u00eda por el sistema de protecci\u00f3n o si el equipo est\u00e1 por encima de la temperatura programada (Set-Point)?\n4.\tSe le solicita amablemente a la convocante que el requisito De Puerta s\u00f3lida con ventana sea opcional porque a temperaturas muy altas, resulta dif\u00edcil instalar una ventana de cristal.\n5.\tCon relaci\u00f3n al punto de Debe incluir la calibraci\u00f3n de temperatura de 3 puntos, disponible para definir el l\u00edmite superior e inferior de la temperatura) - Se le solicita a la convocante amablemente mencionar las temperaturas de calibraci\u00f3n, porque en Brasil se realizan diferentes tipos de calibraci\u00f3n con empresas acreditadas por Inmetro, y para calibrar un dispositivo necesitamos saber temperatura, tiempo y carga, favor indicarnos esos datos.\n6.\tSe le solicita amablemente a la convocante que sea opcional el requisito de cable de alimentaci\u00f3n seg\u00fan norma CEE7/4 tipo F (Schuko) - No disponemos de este cable", "answer": "El oferente deber\u00e1 ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T14:24:39-04:00"}, {"id": "8805ac639db0830cdcad96718aef9e2e-1", "date": "2024-09-18T14:18:02-04:00", "title": "\u00cdtem 11 Caja de cirug\u00eda especializada", "description": "2.12 1 PAR SEPARADOR FARABEUF O SEPARADOR PARKER, de 13 a 14 cm de\nlongitud\n\u00bfSe podr\u00eda cotizar de 12 a 14cm?", "answer": "Respondido en la consulta 82.", "dateAnswered": "2024-09-26T07:19:35-04:00"}, {"id": "a8e38bb10c96cc1f206abad646ffef9f-1", "date": "2024-09-17T17:50:02-04:00", "title": "ITEM 35", "description": "En el \u00edtem 35 de las Especificaciones t\u00e9cnicas donde dice \u201cEl equipo debe trabajar con rangos de frecuencias de 1 a 22 MHz o mayor\u201d, solicitamos a la convocante la exclusi\u00f3n de este \u00edtem o que se considere como opcional. Dado que el equipo est\u00e1 destinado principalmente para aplicaciones en el \u00e1rea de cardiolog\u00eda, no requiere transductores de alta frecuencia, y esta modificaci\u00f3n permitir\u00e1 una mayor flexibilidad en las ofertas y una mejor alineaci\u00f3n con el prop\u00f3sito del equipo", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:17:06-04:00"}, {"id": "4665b69524068130cbbbb5a0da548c7c-1", "date": "2024-09-18T14:33:30-04:00", "title": "\u00cdTEM 35 EC\u00d3GRAFO", "description": "Se solicita a la convocante admitir Transductor microconvexo con ancho de banda de 3 a 11 Mhz. Para dar mayor participaci\u00f3n a oferentes.", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:23:35-04:00"}, {"id": "2fc0e28ddc17679f68a8a6522e2862d0-1", "date": "2024-09-17T17:33:42-04:00", "title": "ITEM 33", "description": "En el \u00edtem 34 de las Especificaciones t\u00e9cnicas donde dice \u201cRango Din\u00e1mico de al menos 350 dB.\u201d, solicitamos a la convocante la modificaci\u00f3n de este \u00edtem por \u201cRango din\u00e1mico de al menos 280 dB\u201d, La mayor\u00eda de los procedimientos cl\u00ednicos no demandan un rango din\u00e1mico de 350 dB. y la modificaci\u00f3n de este \u00edtem a 280 dB alinea el equipo con las necesidades reales de los usuarios y las normativas vigentes", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:15:49-04:00"}, {"id": "614df92b720c068ba28add6393946f12-1", "date": "2024-09-18T22:27:21-04:00", "title": "ID 443857 - \u00cdtem 34 \u2013 Ec\u00f3grafo", "description": "Para el \u00edtem 34 el PBC establece que el Plan de entrega de los bienes ser\u00e1: \"El 100 % dentro de los 30 d\u00edas a partir de la firma del contrato\" Favor solicitamos a la convocante modificar este punto a \"El 100 % dentro de los 90 d\u00edas posteriores a la recepci\u00f3n de la orden de compra por parte del proveedor\".  Lo solicitado obedece en su mayor\u00eda se trata de equipos cuya fabricaci\u00f3n se realiza tras un pedido al fabricante mediante orden de compra, y que posteriormente son importados, por lo que el plazo debe indefectiblemente incluir tiempo de transporte internacional y los procesos aduaneros realizados por terceros.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:29:21-04:00"}, {"id": "52d412e734483559d9c8206ecb41809a-1", "date": "2024-09-18T22:23:59-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Donde dice \"Frame Rate de 6600Hz o mayor\" solicitamos a la convocante modificar este punto a \"Frame Rate de 1.150Hz o mayor\" lo solicitado obedece a que, la finalidad de esta caracter\u00edstica es revisar breves instantes del estudio y evaluar el movimiento del tejido para lo cual el valor solicitado es m\u00e1s que suficiente.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:28:47-04:00"}, {"id": "7bf27c1027a5d531bd777a5a06117c7d-1", "date": "2024-09-18T22:25:15-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Donde dice \"Calculo de velocidades longitudinal radial, circunferencial y Strain Global con despliegue autom\u00e1tico de ojo de buey\" solicitamos a la convocante considerar este punto como OPCIONAL debido a que esta caracter\u00edstica encarece significativamente el precio referencial del ecocardi\u00f3grafo requerido.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:59-04:00"}, {"id": "1d1d43f9a843428da4bcce7dcc156363-1", "date": "2024-09-18T22:39:09-04:00", "title": "\u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Transductor Phased Array de cristal \u00fanico con un ancho de banda de 1 o menor a 5 o mayor Mhz. Que alcance una profundidad de al menos 345mm o mayor. Cantidad: 1 (uno) por equipo\" solicitamos a la convocante modificar este punto a \"Transductor Phased Array  con un ancho de banda de 1.5 o menor a 4.4 o mayor Mhz. Que alcance una profundidad de al menos 300mm o mayor. Cantidad: 1 (uno) por equipo\" dichos par\u00e1metros son est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:07-04:00"}, {"id": "1caa421262e09439ed569fb0cb3f3135-1", "date": "2024-09-19T06:56:20-04:00", "title": "item 42", "description": "6.16 Volumen de fuga De 0 a 3000 ml, solicitamos diga Volumen de fuga De 0 a 3000 ml o en porcentaje", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:37:03-04:00"}, {"id": "58f6f273352f4ecd37b386505e07c73c-1", "date": "2024-09-18T18:51:11-04:00", "title": "Item 16 \u2013 Monitor multiparam\u00e9trico", "description": "Donde piden 16 4.6.2 Etiquetado del sitio de medici\u00f3n: P1, P2, P3, ART, ART2, RAD, DORS, AO, FEM, UA, UV, PAP, CVP, RAP, RVP, LAP, LVP, ICP, ICP2, ICP3, solicitamos se puedan cotizar monitores con las siguientes etiquetas: P1, P2, ART, RAD, AO, FEM, UA, UV, PAP, CVP, RAP, LAP, LVP, ICP, considerando que se contar\u00e1n con dos etiquetas libres y que las etiquetas espec\u00edficas solicitadas corresponden a la marca Nihon Kohden por lo que limita la libre participaci\u00f3n de otros oferentes", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:13:51-04:00"}, {"id": "19693bab0748b073db2e5eea76c749c6-1", "date": "2024-09-14T20:04:44-04:00", "title": "Especificaciones T\u00e9cnicas - \u00cdtem 44 y 45) M\u00e1quinas de Anestesia", "description": "DONDE DICE:\n\n1.7 Normas de calidad espec\u00edficas: FDA, CE o JIS al menos alguna de ellas.\n\nFavor modificar a: \n\n3.1 Normas de calidad: FDA, CE, MERCOSUR o JIS al menos alguna de ellas,\n\nEn los dem\u00e1s \u00edtems de este mismo llamado, se aceptan normas de calidad MERCOSUR, y no aceptarlo en algunos \u00edtems en particular, como el 44 y 45, no tienen ning\u00fan tipo de sentido ni justificaci\u00f3n, salvo la intenci\u00f3n de excluir a alg\u00fan oferente o favorecer a otro.\n\nAdem\u00e1s, se recuerda que el Paraguay es un miembro activo y fundador del MERCOSUR, lo cual debe permitir la inclusi\u00f3n de equipos con normas MERCOSUR para su comercializaci\u00f3n entre los miembros.", "answer": "Remitirse a la Adenda en el SICP.", "dateAnswered": "2024-09-26T07:14:55-04:00"}, {"id": "8b5d6a251f0e4dfd6eeb4b647d47a0d6-1", "date": "2024-09-18T18:35:51-04:00", "title": "MONTO REFERENCIAL", "description": "En relaci\u00f3n con el precio referencial de 391.800.000 gs, observamos que este monto parece ser significativamente bajo considerando las caracter\u00edsticas avanzadas y espec\u00edficas solicitadas en la licitaci\u00f3n. Las especificaciones requeridas, como las funcionalidades de alta gama y las caracter\u00edsticas opcionales para equipos de \u00faltima tecnolog\u00eda, podr\u00edan implicar costos considerablemente mayores. Solicitamos una revisi\u00f3n del precio referencial para asegurar que refleje adecuadamente el valor del equipo con las caracter\u00edsticas requeridas, y permitir as\u00ed una competencia justa entre los oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:12:07-04:00"}, {"id": "9497c30554cee903351f33d94c409536-1", "date": "2024-09-18T18:50:50-04:00", "title": "Item 10 \u2013 Caja de cirug\u00eda especializada", "description": "En el punto 10 2.35 1 PAR SEPARADOR FARABEUF O SEPARADOR US ARMY, de 21 a 22 cm de longitud, solicitamos de pueda cotizar 1 PAR SEPARADOR PARKER-LANGENBERG de 21 a 22 cm de longitud, considerando que cumplen la misma funci\u00f3n", "answer": "La consulta no se identifica.", "dateAnswered": "2024-09-26T08:13:25-04:00"}, {"id": "01d08d81261fc2c7dd2687c2b6faae13-1", "date": "2024-09-18T14:19:14-04:00", "title": "\u00cdtem 25 Cardiodesfibrilador", "description": "6.1 Para pacientes adultos\nCreemos que deber\u00eda decir para pacientes infantiles", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:21:17-04:00"}, {"id": "1328ad7e37f82c30a4d822d6440b0527-1", "date": "2024-09-18T22:50:25-04:00", "title": "SOPORTE TECNICO", "description": "ITEM 33 Punto 8.6 SOPORTE TECNICO: Soporte t\u00e9cnico durante el tiempo de duraci\u00f3n de la garant\u00eda. Presentar declaraci\u00f3n jurada.\nSolicitamos a la convocante pueda ser modificada este criterio de la siguiente manera: Soporte t\u00e9cnico durante el tiempo de duraci\u00f3n de la garant\u00eda del bien ofertado.  Presentar declaraci\u00f3n jurada.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:44-04:00"}, {"id": "b93143893da3e7a7d2c59e9355d9a0bc-1", "date": "2024-09-18T17:42:16-04:00", "title": "\u00cdtem 16 \u2013 Monitor Multiparam\u00e9trico", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 4.6.2 se solicita \u201cEtiquetado del sitio de medici\u00f3n: al menos P1, P2, P3, ART, ART2, RAD, DORS, AO, FEM, UA, UV, PAP, CVP, RAP, RVP, LAP, LVP, ICP, ICP2, ICP3.\u201d, solicitamos a la convocante modificar este punto por \u201cEtiquetado del sitio de medici\u00f3n al menos 15 etiquetas\u201d esto teniendo en cuenta que cada fabricante cuenta con sus propias nomenclaturas para estas etiquetas de PAI, por lo que no necesariamente coincidan todas ellas. Esta modificaci\u00f3n permitir\u00e1 un mayor n\u00famero de oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:33:23-04:00"}, {"id": "aa026d1d34116bfc2364c694cf674950-1", "date": "2024-09-18T22:24:55-04:00", "title": "\u00cdtem 33 \u2013 Ecocardi\u00f3grafo", "description": "Donde dice \"Software para Strain y Strain Rate del Ventr\u00edculo izquierdo basado en el m\u00e9todo 2D speckle tracking con detecci\u00f3n autom\u00e1tica de bordes\" solicitamos a la convocante modificar este punto a \"Software para Strain y Strain Rate del Ventr\u00edculo izquierdo basado en el m\u00e9todo 2D speckle tracking con detecci\u00f3n autom\u00e1ticao manual de bordes\" lo solicitado no afectar\u00e1 la funcionalidad solicitada en este punto, adem\u00e1s lo solicitado es el est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda, por lo que solicitamos modificar este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:55-04:00"}, {"id": "8d94fe3015059249cab1f8ab8311b286-1", "date": "2024-09-18T19:14:44-04:00", "title": "REQUISITOS DOCUMENTALES PARA EVALUAR EL CRITERIO DE CAPACIDAD T\u00c9CNICA", "description": "En el apartado de Requisitos documentales para evaluar el criterio de capacidad t\u00e9cnica, en el \u00edtem 12 se expresa: \u201cDeclaraci\u00f3n jurada de que la empresa adjudicada se compromete a: Incluir mantenimientos preventivos y asistencia t\u00e9cnica a demanda por un a\u00f1o. Que los mantenimientos se realizaran seg\u00fan los est\u00e1ndares de la marca y del equipo ofertado, presentar copia el protocolo de mantenimiento. Que proveer\u00e1 Asistencia t\u00e9cnica seg\u00fan necesidad, sea mantenimiento preventivo o correctivo, en un periodo menor a 48 hs., stock de repuestos y accesorios originales de f\u00e1brica\u201d se solicita amablemente a la convocante aclarar si el mantenimiento correctivo debe incluir la provisi\u00f3n de repuestos. En caso afirmativo, tambi\u00e9n pedimos que se especifique que los mantenimientos correctivos solo cubrir\u00e1n defectos de f\u00e1brica, excluyendo problemas ocasionados por un uso inadecuado por parte del operario o da\u00f1os por factores externos (como por ejemplo el sistema de alimentaci\u00f3n el\u00e9ctrica). Asimismo, solicitamos la exclusi\u00f3n del t\u00e9rmino \"a demanda\", ya que resulta dif\u00edcil predecir la cantidad exacta de mantenimientos necesarios. Los equipos solicitados contar\u00e1n con garant\u00eda y ser\u00e1n nuevos, por lo que consideramos innecesario que el mantenimiento sea \"a demanda", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:16:23-04:00"}, {"id": "35b598a36c0226e84a2eafabcaf0f499-1", "date": "2024-09-25T17:55:01-04:00", "title": "ESPECIFICACIONES TECNICAS - ITEM 20. 4.5", "description": "\"Capacidad de ampliar el largo total del lecho de forma manual: 25 cm \u00b1 5 cm\", solicitamos a la convocante considerar ajustar la especificaci\u00f3n a 20 +-5 . Esto proporcionar\u00eda una mayor flexibilidad en el ajuste del lecho, permitiendo una mejor adaptaci\u00f3n a las necesidades de pacientes de diferentes alturas, sin comprometer la funcionalidad del equipo en entornos\u00a0cl\u00ednicos", "answer": "Respondido en la Consulta 261.", "dateAnswered": "2024-09-26T14:25:17-04:00"}, {"id": "9039d8c2f4d0960d704563b259c1ae0d-1", "date": "2024-09-23T14:57:01-04:00", "title": "Porcentaje de multas y Tasa de inter\u00e9s por Mora", "description": "Se solicita a la convocante que se considere la posibilidad de reducir el porcentaje de multa a un 0,01%, en concordancia con la tasa de inter\u00e9s por mora aplicada a la parte contratante. Consideramos que esta solicitud contribuir\u00e1 a una relaci\u00f3n m\u00e1s justa y equitativa entre ambas partes.", "answer": "Ajustarse a lo solicitado en el PBC, atendiendo a los plazos, establecidos en la Resoluci\u00f3n DNCP N\u00b0 1430/2024 \"Plazos m\u00e1ximos para comunicar a la DNCP los llamados, adjudicaciones y contratos que afecten a los procesos que comprometan el PGN 2024\", en cuanto se refiere a los env\u00edos de adjudicaciones, esta convocatoria de gran envergadura, cuenta con plazos limitados para la evaluaci\u00f3n, cierre y posterior firmas de contratos, se ha tenido suficiente tiempo para las consultas respectivas, las mismas han sido adendadas en su gran mayor\u00eda por la Instituci\u00f3n.", "dateAnswered": "2024-09-26T13:53:14-04:00"}, {"id": "f2d6b3bb31158ed7f64971f2cfddcc5c-1", "date": "2024-09-18T21:18:43-04:00", "title": "\u00cdtem 42: Ventilador pulmonar de alta complejidad.", "description": "El PBC solicita Pantalla LCD de 19 \u00b1 2\". Perilla o botones selectores para ajuste de valores.Se solicita amablemente a la convocante permitir cotizar equipo, sin ir en detrimento de lo solicitado, y permitir la competencia de marcas con experiencia comprobada en el mercado local, sean aceptados equipos con Pantalla LCD de al menos 15\u201d.Perilla o botones selectores para ajuste de valores, a fin de brindar mayor oportunidad de participacion a los oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:27:24-04:00"}, {"id": "ae649d6b0d40c5d9e7f6b79781719239-1", "date": "2024-09-18T19:10:39-04:00", "title": "ESPECIFICACIONES TECNICAS - Item 33. Punto 6.2", "description": "\u201cTransductor sectorial o phased array de cristal \u00fanico para paciente adulto con ancho de banda de 1 MHz o menor a 5 MHz o mayor. Con Campo de apertura de almenos 90\u00b0. Que alcance una profundidad de escaneo de al menos 35cm o mayor\u201d Solicitamos a la convocante que considere ajustar los requisitos para el \"Transductor sectorial o phased array de cristal \u00fanico para paciente adulto\" para que el campo de apertura sea de al menos 120\u00b0 y la profundidad de escaneo sea de 30 cm o m\u00e1s. Un campo de apertura mayor de 120\u00b0 permite una cobertura m\u00e1s amplia y mejora la capacidad para obtener im\u00e1genes de estructuras extensas en un solo barrido, lo cual puede ser crucial para un diagn\u00f3stico m\u00e1s eficiente y preciso. Adem\u00e1s, al especificar una profundidad de escaneo de 30 cm o m\u00e1s, se garantiza que el equipo pueda satisfacer una gama m\u00e1s amplia de necesidades cl\u00ednicas, sin limitar innecesariamente las propuestas a un rango muy espec\u00edfico. Estos ajustes ofrecen mayor flexibilidad a los oferentes y aseguran que el equipo se adapte mejor a diferentes aplicaciones cl\u00ednicas.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:16:15-04:00"}, {"id": "b65818301afee3b7ffaecfb746d3d618-1", "date": "2024-09-14T11:06:26-04:00", "title": "Especificaciones T\u00e9cnicas - \u00cdtem 42) Ventilador Pulmonar de Alta Complejidad", "description": "DONDE DICE:\n\n4.11 Frecuencia respiratoria (bpm). L\u00edmite inferior 1 o menor y limite superior 150 o mayor.\n4.13 Pausa Inspiratoria\n4.14 Pausa Espiratoria\n4.15 Pendiente de inyecci\u00f3n de flujo inspiratorio ajustable (%). De 5 a 100\n4.19 Posibilidad de realizar evaluaci\u00f3n del potencial de reclutamiento alveolar.\n4.20 Posibilidad de titulaci\u00f3n del PEEP.\n\nFavor modificar a: \n\n4.11 Frecuencia respiratoria (bpm). L\u00edmite inferior 1 o menor y limite superior 80 o mayor.\n4.15 Pendiente de inyecci\u00f3n de flujo inspiratorio ajustable (%). De 5 a 100 (OPCIONAL)\n4.19 Posibilidad de realizar evaluaci\u00f3n del potencial de reclutamiento alveolar. (OPCIONAL)\n4.20 Posibilidad de titulaci\u00f3n del PEEP. (OPCIONAL)\n\nLo solicitado es por el motivo que sokn condiciones t\u00e9cnicas no indispensables para el funcionamiento del equipo, no afecta en sus prestaciones, y con la modificaci\u00f3n se permitir\u00e1 mayor concurrencia y posibilidad de contar con mayor cantidad de ofertas y marcas ofertadas, y como consecuencia, aumentar las posibilidades de mejores condiciones de contrataci\u00f3n para la entidad, en concordancia con los principios de econom\u00eda, eficacia y eficiencia y de igualdad y libre competencia.", "answer": "Remitirse a la Adenda en el SICP.", "dateAnswered": "2024-09-26T07:14:34-04:00"}, {"id": "5a640ef0c4a362ba2f7b7e26aa9f51b7-1", "date": "2024-09-18T22:08:11-04:00", "title": "ITEM 44 \u2013 MAQUINA DE ANESTESIA", "description": "En el punto 5.6 donde dice \u201cDespliegue de curvas de presi\u00f3n vs. Tiempo y volumen vs. Tiempo, al menos cinco curvas en simultaneo en la pantalla de ventilaci\u00f3n\u201d solicitamos amablemente a la convocante que la cantidad de curvas en simultaneo que se despliegue en la pantalla sea de al menos tres, esto considerando la disponibilidad disponible en el mercado y que no solo una empresa lo pueda ofrecer como es el caso de la firma LCM. Solicitamos dar apertura a las eett y dar cumplimiento a lo establecido en ley de contrataciones publicas", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:28:14-04:00"}, {"id": "eb90987ce3aa5678a7107a03ee9835f5-1", "date": "2024-09-18T21:18:56-04:00", "title": "\u00cdtem 42: Ventilador pulmonar de alta complejidad.", "description": "El PBC solicita Sensor de SpO2 tipo pinza reutilizable de la misma marca que el ventilador. Se solicita amablemente a la convocante permitir cotizar equipo, sin ir en detrimento de lo solicitado, con la provisi\u00f3n de sensores de oximetr\u00eda aptos y validados para la tecnolog\u00eda de nuestros equipos y as\u00ed permitir la competencia de marcas con experiencia comprobada en el mercado local, sean aceptados equipos con Sensor de SpO2 tipo pinza reutilizable con tecnolog\u00eda validada para  el ventilador, a fin de brindar mayor oportunidad de participacion a los oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:27:28-04:00"}, {"id": "f3b35a6ffe6f1c2fd02d3ce65d2d310d-1", "date": "2024-09-18T22:37:59-04:00", "title": "\u00cdtem 38 \u2013 Equipo de Rayos X M\u00f3vil", "description": "Para el \u00edtem 38 Donde dice \"Los equipos deber\u00e1n contar con 2 (dos) a\u00f1os de garant\u00eda desde la puesta en funcionamiento, e incluir como m\u00ednimo 1 (un) mantenimiento preventivo anual durante dicho periodo\" solicitamos a la convocante aclarar si la garant\u00eda solicitada incluye repuestos y materiales de desgaste como son los tubos de rayos x. Adem\u00e1s, solicitamos confirmar que la garant\u00eda no incluir\u00e1 los da\u00f1os que pudiere sufrir el equipo por errores de utilizaci\u00f3n y/o golpes.", "answer": "Se aclara que la garantia de dos a\u00f1os debe incluir todos los materiales que requieren ser cambiados durante este periodo, incluyendo el tubo de rayos x, siempre y cuando el equipo sea utilizado de acuerdo a las indicaciones del fabricante.", "dateAnswered": "2024-09-26T08:36:02-04:00"}, {"id": "4306458dd323caab9078c43e1b282c96-1", "date": "2024-09-18T19:15:08-04:00", "title": "item 20 Cama electrica", "description": "En el Item 20 Cama el\u00e9ctrica a para paciente: En el punto 5.1 solicitan altura m\u00e1xima de 85 cm +/- 5 cm, solicitamos a la convocante poder cotizar con altura m\u00e1xima de 75 cm +/- 5 cm", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:16:43-04:00"}, {"id": "b355dc6f2527bb09c8b6b770800880d3-1", "date": "2024-09-18T22:36:45-04:00", "title": "ID 443857 - \u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Al menos 4.000.000 de canales digitales de procesamiento\" solicitamos a la convocante modificar este punto a \"Al menos 450.000 canales digitales de procesamiento\"   Lo solicitado obedece a que cada casa comercial calcula los canales de procesamiento digitales mediante una f\u00f3rmula matem\u00e1tica propia, que no se ha estandarizado en el mercado y lo cual hace que los n\u00fameros de canales digitales no sean comparables entre una marca y otra. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:35:41-04:00"}, {"id": "f3d84c8f62682b143f3a00d91d8eca29-1", "date": "2024-09-25T18:42:11-04:00", "title": "REQUISITOS DOCUMENTALES PARA EVALUAR EL CRITERIO DE CAPACIDAD T\u00c9CNICA", "description": "Requisito documental para evaluar el criterio de capacidad t\u00e9cnica: En la secci\u00f3n de requisito documental para evaluar el criterio de capacidad t\u00e9cnica se solicita en el \u00edtem 8: \u201cCertificado de Registro Sanitario, de conformidad a la Ley 4959/12\u201d. Se solicita a la convocante la exclusi\u00f3n para el \u00edtem 28 (Centr\u00edfuga), \u00edtem 40 (Estufa de secado) e \u00edtem 50 (Microscopio) del presente requerimiento. Estos equipos son de uso general en laboratorio y, de acuerdo con las resoluciones estipuladas por DINAVISA, no requieren registro sanitario", "answer": "Ajustarse a lo solicitado en el Pliego de Bases y Condiciones.", "dateAnswered": "2024-09-26T14:25:42-04:00"}, {"id": "6522929ecd62333776cc923cf837f009-1", "date": "2024-09-13T16:33:02-04:00", "title": "Item N\u00b0 37 \u2013 EETT.", "description": "Solicitamos amablemente a la convocante donde dice: \u201cPunto 2.17.2 \u2013 Desinfecci\u00f3n qu\u00edmica y termina, programables, con hasta 10 etapas\u201d, modificar como sigue: \u201cDesinfecci\u00f3n qu\u00edmica y termina, programables\u201d, ya que cada marca posee preconfigurada sus procesos de desinfecci\u00f3n, lo que normalmente se realiza es la modificaci\u00f3n del tiempo de cada etapa. Consideramos que este factor es limitante ya que una sola marca internacional posee esa opci\u00f3n de software. De esta forma se garantizara la libre competencia y mayor cantidad de posibles oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T07:14:05-04:00"}, {"id": "184880913a1eb373189e7905780c0928-1", "date": "2024-09-18T17:44:43-04:00", "title": "\u00cdtem 44 \u2013 M\u00e1quina de Anestesia", "description": "\u2022\tEn las Especificaciones T\u00e9cnicas en el punto 5.16 se solicita \u201cDisplay: de 17 pulgadas \u00b1 2\", tipo touchscreen (T\u00e1ctil). Tecnolog\u00eda LCD/TFT de alta resoluci\u00f3n. Trazados: 15 curvas fisiol\u00f3gicas de forma simult\u00e1nea.\u201d solicitamos a la Convocante pueda modificar este punto por \u201cDisplay: de 15 pulgadas \u00b1 2\", tipo touchscreen (T\u00e1ctil). Tecnolog\u00eda LCD/TFT de alta resoluci\u00f3n. Trazados: 12 curvas fisiol\u00f3gicas de forma simult\u00e1nea.\u201d De manera a ajustarse al tipo de equipo solicitado (mediana complejidad) y tambien al precio referencial unitario para este \u00edtem.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:10:10-04:00"}, {"id": "6d122b2d776c96445aca061d03a30a2a-1", "date": "2024-09-18T14:20:26-04:00", "title": "\u00cdtem 54 Nefroscopio", "description": "9.4 Capacitaci\u00f3n a usuarios sobre el funcionamiento del equipo y capacitaci\u00f3n t\u00e9cnica al personal t\u00e9cnico del Departamento de Electromedicina. Presentar declaraci\u00f3n jurada.\nSolicitamos excluir este requisito, considerando que no se trata de un equipo", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:22:56-04:00"}, {"id": "ef6e376fb479747a55bd2979d61e4817-1", "date": "2024-09-18T14:44:41-04:00", "title": "/*Requisitos documentales para evaluar el criterio de capacidad t\u00e9cnica", "description": "Solicitamos a la convocante aclarar si el punto 4 y el punto 11 serian lo mismo.", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:23:43-04:00"}, {"id": "5b1214562f900965c1fd38c0f8c716c9-1", "date": "2024-09-25T17:31:39-04:00", "title": "ESPECIFICACIONES TECNICAS - ITEM 20 4.4", "description": "Donde se solicita \"Dimensiones de la superficie para el paciente. Longitud m\u00ednima 190 cm \u00b1 5 cm, Ancho m\u00ednimo 80 cm \u00b1 5 cm\", solicitamos a la convocante considerar ajustar las especificaciones a 195 cm \u00b1 10 cm de longitud y 85 cm \u00b1 5 cm de ancho. Estas medidas ofrecen mayor comodidad para el paciente y permiten una mayor flexibilidad en el uso de colchones y accesorios cl\u00ednicos, sin comprometer la funcionalidad o adaptabilidad del equipo en entornos cr\u00edticos.", "answer": "Respondido en la Consulta 66.", "dateAnswered": "2024-09-26T14:24:58-04:00"}, {"id": "e9f63296c2a4260343063f236a7c716d-1", "date": "2024-09-18T09:40:38-04:00", "title": "Especificaciones tecnicas", "description": "SOLICITAMOS a la convocante modifique el punto 10.5\"Nebulizador con tecnolog\u00eda de malla vibratoria o ultras\u00f3nico. Adaptadores de v\u00edas a\u00e9reas para nebulizaci\u00f3n 5 (cinco) por cada equipo. Reservorio para el medicamento de la nebulizaci\u00f3n 2 (dos) por cada equipo.\", a \"Nebulizador con tecnolog\u00eda de malla vibratoria o ultras\u00f3nico o neum\u00e1tica. Adaptadores de v\u00edas a\u00e9reas para nebulizaci\u00f3n 5 (cinco) por cada equipo. Reservorio para el medicamento de la nebulizaci\u00f3n 2 (dos) por cada equipo.\" ya que esta modificaci\u00f3n no afecta la calidad y eficacia de los tratamientos realizados, ademas de no limitar la participaci\u00f3n. Caso contrario nos veremos en la necesidad de realizar una protesta en la que vamos a mencionar la marca y el modelo a que corresponde estas especificaciones que limitan la participaci\u00f3n", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:17:44-04:00"}, {"id": "0a0115431e03e24dd12601368ed77be9-1", "date": "2024-09-18T22:29:57-04:00", "title": "ID 443857 - \u00cdtem 34 \u2013 Ec\u00f3grafo", "description": "Donde dice \"Beam former de al menos hasta 16 zonas focales de transductor din\u00e1micamente controlados\" solicitamos a la convocante modificar este punto a \"Beam former de al menos hasta 8 zonas focales de transductor din\u00e1micamente controlados\" lo solicitado es est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda y lo normalmente aceptado por los m\u00e9dicos. Por lo que solicitamos que modifiquen este punto a fin de permitir la participaci\u00f3n de potenciales oferentes.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:34:41-04:00"}, {"id": "ddd073d243f6446f919064532f8db06c-1", "date": "2024-09-18T21:12:02-04:00", "title": "\u00cdtem 42: Ventilador pulmonar de alta complejidad.", "description": "El PBC solicita Nebulizador con tecnolog\u00eda de malla vibratoria o ultras\u00f3nico. Se solicita amablemente a la convocante permitir cotizar equipo, sin ir en detrimento de lo solicitado, y permitir la competencia de marcas con experiencia comprobada en el mercado local, sean aceptados equipos con Nebulizador con tecnolog\u00eda de malla vibratoria o ultras\u00f3nico o neum\u00e1tico controlado electr\u00f3nicamente, a fin de brindar mayor oportunidad de participacion a los oferentes.", "answer": "Remitirse la Adenda, en el SICP.", "dateAnswered": "2024-09-26T08:27:16-04:00"}, {"id": "cdad8c46d3c4cc1112882e53f4f7187e-1", "date": "2024-09-18T22:41:01-04:00", "title": "\u00cdtem 35 \u2013 Ec\u00f3grafo", "description": "Donde dice \"El software de Strain debe contar con 3 m\u00e9todos MANUAL, SEMIAUTOMATICO, AUTOMATICO para colocaci\u00f3n de puntos de evaluaci\u00f3n de los segmentos\" solicitamos a la convocante modificar este punto a \"El software de Strain debe contar con al menos 2 m\u00e9todos MANUAL y SEMIAUTOMATICO para colocaci\u00f3n de puntos de evaluaci\u00f3n de los segmentos\"  El cambio solicitado no afecta a la calidad de imagen, adem\u00e1s, la caracter\u00edstica solicitada es el est\u00e1ndar en la mayor\u00eda de los equipos de ecograf\u00eda, por lo que solicitamos se actualice este punto a fin de tener la participaci\u00f3n de las marcas con reconocida representaci\u00f3n y comprobada calidad en el mercado local e internacional. Dejamos conocimiento que el conjunto de todas las caracter\u00edsticas solicitadas para este \u00edtem n\u00famero 35 est\u00e1n direccionadas a la marca GE modelo Versana Active, por lo que solicitamos modifiquen este punto a fin de evitar favorecer a una marca en particular.", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:22-04:00"}, {"id": "c18ee3f360cd8b867a2f2349f3708bf6-1", "date": "2024-09-18T14:20:11-04:00", "title": "\u00edtem 48 Mesa quir\u00fargica", "description": "1. Mesa quir\u00fargica para uso con pacientes de hasta 280kg \u00b1 30 kg\nConsiderando que entre los accesorios se solicitan extensores para pacientes obesos (#1.3.11), creemos que el peso m\u00ednimo de pacientes deber\u00eda de al menos 400kg, favor verificar.", "answer": "Remitirse a la Adenda, en el SICP.", "dateAnswered": "2024-09-26T07:22:49-04:00"}, {"id": "90c033c8d4d9d52466f47f7c3e3a4352-1", "date": "2024-09-19T06:39:32-04:00", "title": "item 42 Ventilador", "description": "Donde dice Pendiente de inyecci\u00f3n de flujo inspiratorio ajustable (%). De 5 a 100, solicitamos diga Pendiente de inyecci\u00f3n de flujo inspiratorio ajustable en al menos 20 niveles, siendo 1 (lento) y 20 (r\u00e1pido)", "answer": "Ajustarse a lo solicitado en el PBC.", "dateAnswered": "2024-09-26T08:36:55-04:00"}, {"id": "089be0476abb2a2aa082f4c9082b0d65-1", "date": "2024-09-25T18:25:45-04:00", "title": "\u00cdtem 53", "description": "Donde dice \"7.8 - Nivel de ruido < 0.5 \u03bcV rms de 0,5 Hz a 30 Hz\", solicitamos a la convocante considerar un rango de ruido de 0,5 \u03bcV a 1,5 \u03bcV rms como m\u00e1ximo, con rangos de frecuencia que cubran 0,2 a 2 Hz en el extremo bajo y 15 a 30 Hz en el extremo alto. Esto permitir\u00e1 una mayor flexibilidad y facilitar\u00e1 la participaci\u00f3n de m\u00e1s oferentes.", "answer": "Respondido en la Consulta 249.", "dateAnswered": "2024-09-26T14:25:20-04:00"}], "lots": [{"id": "1ef66c97-bb37-622e-9c94-03138fe681b4", "title": "64 - 64 - Transductor para ecografo", "status": "active", "statusDetails": "activo", "value": {"amount": 41250000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "64", "id": "64"}]}, {"id": "1ef66c97-bab3-6a32-8e42-03138fe681b4", "title": "52 - 52 - Monitor cardiofetal", "status": "active", "statusDetails": "activo", "value": {"amount": 65766666, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "52", "id": "52"}]}, {"id": "1ef66c97-bb0b-6d04-9d2f-03138fe681b4", "title": "59 - 59 - Silla Sanitaria", "status": "active", "statusDetails": "activo", "value": {"amount": 8800002, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "59", "id": "59"}]}, {"id": "1ef66c97-ba81-63de-a101-03138fe681b4", "title": "42 - 42 - Ventilador pulmonar de alta complejidad", "status": "active", "statusDetails": "activo", "value": {"amount": 1048173332, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "42", "id": "42"}]}, {"id": "1ef66c97-b9c5-6fc6-b6d0-03138fe681b4", "title": "6 - 6 - Caja de Cirugia General", "status": "active", "statusDetails": "activo", "value": {"amount": 45000000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "6", "id": "6"}]}, {"id": "1ef66c97-b9bf-6f2c-bf46-03138fe681b4", "title": "5 - 5 - Caja de Cirugia especializada", "status": "active", "statusDetails": "activo", "value": {"amount": 22500000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "5", "id": "5"}]}, {"id": "1ef66c97-baa9-6460-89f5-03138fe681b4", "title": "50 - 50 - Microscopio Optico", "status": "active", "statusDetails": "activo", "value": {"amount": 150437500, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "50", "id": "50"}]}, {"id": "1ef66c97-b9e6-6622-8433-03138fe681b4", "title": "12 - 12 - Caja de Cirugia especializada", "status": "active", "statusDetails": "activo", "value": {"amount": 40950000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "12", "id": "12"}]}, {"id": "1ef66c97-ba00-6b12-a289-03138fe681b4", "title": "17 - 17 - Caja de Cirugia Pediatrica", "status": "active", "statusDetails": "activo", "value": {"amount": 70500000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "17", "id": "17"}]}, {"id": "1ef66c97-b9e1-66a4-a72d-03138fe681b4", "title": "11 - 11 - Caja de Cirugia especializada", "status": "active", "statusDetails": "activo", "value": {"amount": 30000000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "11", "id": "11"}]}, {"id": "1ef66c97-babd-6dca-b3c5-03138fe681b4", "title": "54 - 54 - Nefroscopio", "status": "active", "statusDetails": "activo", "value": {"amount": 115885000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "54", "id": "54"}]}, {"id": "1ef66c97-bb1e-690e-b0a4-03138fe681b4", "title": "61 - 61 - Sistema de Monitorizacion Holter", "status": "active", "statusDetails": "activo", "value": {"amount": 30300000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "61", "id": "61"}]}, {"id": "1ef66c97-ba15-6a62-99c8-03138fe681b4", "title": "21 - 21 - Cama electrica para paciente", "status": "active", "statusDetails": "activo", "value": {"amount": 142049997, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "21", "id": "21"}]}, {"id": "1ef66c97-ba3f-6c40-8ab2-03138fe681b4", "title": "29 - 29 - Caja de Cirugia", "status": "active", "statusDetails": "activo", "value": {"amount": 47466667, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "29", "id": "29"}]}, {"id": "1ef66c97-b9fb-6748-90c8-03138fe681b4", "title": "16 - 16 - Monitor multiparametrico", "status": "active", "statusDetails": "activo", "value": {"amount": 485749998, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "16", "id": "16"}]}, {"id": "1ef66c97-ba62-65b0-b112-03138fe681b4", "title": "36 - 36 - Electrocardiografo", "status": "active", "statusDetails": "activo", "value": {"amount": 180000000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "36", "id": "36"}]}, {"id": "1ef66c97-ba3a-6a10-9e0c-03138fe681b4", "title": "28 - 28 - Centrifuga", "status": "active", "statusDetails": "activo", "value": {"amount": 4829000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "28", "id": "28"}]}, {"id": "1ef66c97-ba8f-6dd0-9052-03138fe681b4", "title": "45 - 45 - Maquina de anestesia", "status": "active", "statusDetails": "activo", "value": {"amount": 382650000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "45", "id": "45"}]}, {"id": "1ef66c97-b9f1-6496-9f22-03138fe681b4", "title": "14 - 14 - Caja de Cirugia General", "status": "active", "statusDetails": "activo", "value": {"amount": 15491667, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "14", "id": "14"}]}, {"id": "1ef66c97-b9b4-6a96-89b0-03138fe681b4", "title": "3 - 3 - Balanza pediatrica", "status": "active", "statusDetails": "activo", "value": {"amount": 5166666, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "3", "id": "3"}]}, {"id": "1ef66c97-ba0f-6f68-a733-03138fe681b4", "title": "20 - 20 - Cama electrica para paciente", "status": "active", "statusDetails": "activo", "value": {"amount": 667333338, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "20", "id": "20"}]}, {"id": "1ef66c97-b9ba-65ae-ad97-03138fe681b4", "title": "4 - 4 - Biometro", "status": "active", "statusDetails": "activo", "value": {"amount": 318750000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "4", "id": "4"}]}, {"id": "1ef66c97-ba5d-657e-a55b-03138fe681b4", "title": "35 - 35 - Ecografo", "status": "active", "statusDetails": "activo", "value": {"amount": 236400000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "35", "id": "35"}]}, {"id": "1ef66c97-bb2f-601a-93dd-03138fe681b4", "title": "63 - 63 - Transductor para ecografo", "status": "active", "statusDetails": "activo", "value": {"amount": 41800000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "63", "id": "63"}]}, {"id": "1ef66c97-bace-63fa-a271-03138fe681b4", "title": "55 - 55 - Porta suero", "status": "active", "statusDetails": "activo", "value": {"amount": 8566660, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "55", "id": "55"}]}, {"id": "1ef66c97-ba99-6e70-99a5-03138fe681b4", "title": "47 - 47 - Mesa de Instrumental", "status": "active", "statusDetails": "activo", "value": {"amount": 7640000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "47", "id": "47"}]}, {"id": "1ef66c97-bae2-6c74-8406-03138fe681b4", "title": "56 - 56 - Incubadora  Servocuna", "status": "active", "statusDetails": "activo", "value": {"amount": 108666667, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "56", "id": "56"}]}, {"id": "1ef66c97-bb47-6354-b58a-03138fe681b4", "title": "66 - 66 - Transductor para ecografo", "status": "active", "statusDetails": "activo", "value": {"amount": 44000000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "66", "id": "66"}]}, {"id": "1ef66c97-ba25-661a-b623-03138fe681b4", "title": "24 - 24 - Cardiodesfibrilador", "status": "active", "statusDetails": "activo", "value": {"amount": 150666666, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "24", "id": "24"}]}, {"id": "1ef66c97-ba2f-69f8-a99d-03138fe681b4", "title": "26 - 26 - Carro de paro", "status": "active", "statusDetails": "activo", "value": {"amount": 70200000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "26", "id": "26"}]}, {"id": "1ef66c97-ba8b-6276-9db9-03138fe681b4", "title": "44 - 44 - Maquina de anestesia", "status": "active", "statusDetails": "activo", "value": {"amount": 729941334, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "44", "id": "44"}]}, {"id": "1ef66c97-b9a8-6354-903d-03138fe681b4", "title": "1 - 1 - Aspirador de Secreciones ", "status": "active", "statusDetails": "activo", "value": {"amount": 50500000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "1", "id": "1"}]}, {"id": "1ef66c97-b9d0-6ed0-a4fa-03138fe681b4", "title": "8 - 8 - Caja de Cirugia Menor", "status": "active", "statusDetails": "activo", "value": {"amount": 11000000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "8", "id": "8"}]}, {"id": "1ef66c97-ba6c-6bf0-8bf9-03138fe681b4", "title": "38 - 38 - Equipo de rayos X portatil", "status": "active", "statusDetails": "activo", "value": {"amount": 533277000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "38", "id": "38"}]}, {"id": "1ef66c97-baf4-61fe-b041-03138fe681b4", "title": "57 - 57 - Tabla  para Diseccion", "status": "active", "statusDetails": "activo", "value": {"amount": 311850000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "57", "id": "57"}]}, {"id": "1ef66c97-bb00-6792-9037-03138fe681b4", "title": "58 - 58 - Silla de rueda plegable", "status": "active", "statusDetails": "activo", "value": {"amount": 35333340, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "58", "id": "58"}]}, {"id": "1ef66c97-ba05-6b30-96b2-03138fe681b4", "title": "18 - 18 - Caja de traumatologia y ortopedia", "status": "active", "statusDetails": "activo", "value": {"amount": 44276667, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "18", "id": "18"}]}, {"id": "1ef66c97-bab8-6884-80fb-03138fe681b4", "title": "53 - 53 - Monitor multiparametrico", "status": "active", "statusDetails": "activo", "value": {"amount": 538050000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "53", "id": "53"}]}, {"id": "1ef66c97-ba34-6e08-9fbf-03138fe681b4", "title": "27 - 27 - Carro para curaciones", "status": "active", "statusDetails": "activo", "value": {"amount": 9666668, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "27", "id": "27"}]}, {"id": "1ef66c97-ba7c-6780-a897-03138fe681b4", "title": "41 - 41 - Lampara cialitica con satelite", "status": "active", "statusDetails": "activo", "value": {"amount": 413000000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "41", "id": "41"}]}, {"id": "1ef702d7-ddd8-6680-b15a-9186720705fb", "title": "60 - 60 - Set de Equipos odontologicos", "status": "active", "statusDetails": "activo", "value": {"amount": 69072340, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "60", "id": "60"}]}, {"id": "1ef66c97-ba4e-6e0c-b76e-03138fe681b4", "title": "32 - 32 - Citoscopio", "status": "active", "statusDetails": "activo", "value": {"amount": 40000000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "32", "id": "32"}]}, {"id": "1ef66c97-b9cb-6836-aaf2-03138fe681b4", "title": "7 - 7 - Caja de Cirugia", "status": "active", "statusDetails": "activo", "value": {"amount": 140000000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "7", "id": "7"}]}, {"id": "1ef66c97-baa3-6fec-bf9d-03138fe681b4", "title": "49 - 49 - Mesita de apoyo de cabecera / alimentacion del paciente", "status": "active", "statusDetails": "activo", "value": {"amount": 15049998, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "49", "id": "49"}]}, {"id": "1ef66c97-ba20-6296-be3b-03138fe681b4", "title": "23 - 23 - Camilla con ruedas", "status": "active", "statusDetails": "activo", "value": {"amount": 34741665, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "23", "id": "23"}]}, {"id": "1ef66c97-bb27-63a6-89c4-03138fe681b4", "title": "62 - 62 - Transductor para ecografo", "status": "active", "statusDetails": "activo", "value": {"amount": 41250000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "62", "id": "62"}]}, {"id": "1ef66c97-ba77-6474-a7a4-03138fe681b4", "title": "40 - 40 - Estufa de secado", "status": "active", "statusDetails": "activo", "value": {"amount": 23670000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "40", "id": "40"}]}, {"id": "1ef66c97-ba2a-6566-b221-03138fe681b4", "title": "25 - 25 - Cardiodesfibrilador", "status": "active", "statusDetails": "activo", "value": {"amount": 62000000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "25", "id": "25"}]}, {"id": "1ef66c97-b9d6-6772-b15e-03138fe681b4", "title": "9 - 9 - Caja de Cirugia Menor", "status": "active", "statusDetails": "activo", "value": {"amount": 35000000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "9", "id": "9"}]}, {"id": "1ef66c97-ba0a-68ba-9cca-03138fe681b4", "title": "19 - 19 - Caja de curacion", "status": "active", "statusDetails": "activo", "value": {"amount": 44000000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "19", "id": "19"}]}, {"id": "1ef66c97-ba49-6d4e-81da-03138fe681b4", "title": "31 - 31 - Set para cirugia laparoscopica", "status": "active", "statusDetails": "activo", "value": {"amount": 100333333, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "31", "id": "31"}]}, {"id": "1ef66c97-ba44-6c36-8d32-03138fe681b4", "title": "30 - 30 - Caja de Cirugia", "status": "active", "statusDetails": "activo", "value": {"amount": 26730000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "30", "id": "30"}]}, {"id": "1ef66c97-ba94-6fba-aac5-03138fe681b4", "title": "46 - 46 - Mesa de instrumental ", "status": "active", "statusDetails": "activo", "value": {"amount": 2033000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "46", "id": "46"}]}, {"id": "1ef66c97-baae-65be-9437-03138fe681b4", "title": "51 - 51 - Microscopios de fluorescencia", "status": "active", "statusDetails": "activo", "value": {"amount": 113219500, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "51", "id": "51"}]}, {"id": "1ef66c97-ba58-6a24-b58f-03138fe681b4", "title": "34 - 34 - Ecografo", "status": "active", "statusDetails": "activo", "value": {"amount": 391800000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "34", "id": "34"}]}, {"id": "1ef66c97-bb3e-6eca-8726-03138fe681b4", "title": "65 - 65 - Transductor para ecografo", "status": "active", "statusDetails": "activo", "value": {"amount": 44500000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "65", "id": "65"}]}, {"id": "1ef66c97-ba86-6096-88a5-03138fe681b4", "title": "43 - 43 - Laringoscopio Adulto", "status": "active", "statusDetails": "activo", "value": {"amount": 31466664, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "43", "id": "43"}]}, {"id": "1ef66c97-ba53-6b96-a2c5-03138fe681b4", "title": "33 - 33 - Ecocardiografo", "status": "active", "statusDetails": "activo", "value": {"amount": 455000000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "33", "id": "33"}]}, {"id": "1ef66c97-ba1a-6c24-a5b3-03138fe681b4", "title": "22 - 22 - Camilla fija", "status": "active", "statusDetails": "activo", "value": {"amount": 68397750, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "22", "id": "22"}]}, {"id": "1ef66c97-b9db-6bb4-bed9-03138fe681b4", "title": "10 - 10 - Caja de Cirugia especializada", "status": "active", "statusDetails": "activo", "value": {"amount": 130000000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "10", "id": "10"}]}, {"id": "1ef66c97-ba67-683a-8b82-03138fe681b4", "title": "37 - 37 - Equipo de hemodialisis", "status": "active", "statusDetails": "activo", "value": {"amount": 273133334, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "37", "id": "37"}]}, {"id": "1ef66c97-b9eb-6a6e-81a3-03138fe681b4", "title": "13 - 13 - Caja de Cirugia", "status": "active", "statusDetails": "activo", "value": {"amount": 12316667, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "13", "id": "13"}]}, {"id": "1ef66c97-bb4f-65ae-8700-03138fe681b4", "title": "67 - 67 - Caja de Cirugia Especializada", "status": "active", "statusDetails": "activo", "value": {"amount": 187641350, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "67", "id": "67"}]}, {"id": "1ef66c97-b9f6-64dc-94f1-03138fe681b4", "title": "15 - 15 - Caja de Cirugia General", "status": "active", "statusDetails": "activo", "value": {"amount": 17920933, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "15", "id": "15"}]}, {"id": "1ef66c97-b9af-650a-baeb-03138fe681b4", "title": "2 - 2 - Balanza electronica digital con tallimetro", "status": "active", "statusDetails": "activo", "value": {"amount": 275000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "2", "id": "2"}]}, {"id": "1ef66c97-ba72-603c-b0a3-03138fe681b4", "title": "39 - 39 - Estante para sala de esterilizacion", "status": "active", "statusDetails": "activo", "value": {"amount": 7316619, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "39", "id": "39"}]}, {"id": "1ef66c97-ba9e-6e20-90ac-03138fe681b4", "title": "48 - 48 - Mesa Quirurgica", "status": "active", "statusDetails": "activo", "value": {"amount": 368750000, "currency": "PYG"}, "simultaneousSupply": false, "attributes": [{"name": "Orden", "value": "48", "id": "48"}]}], "items": [{"id": "1ef66c97-ba59-65be-929b-03138fe681b4", "description": "Ecografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42201718-001", "description": "Ecografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42201718-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42201718", "description": "Ecografos y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42201718"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 391800000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba58-6a24-b58f-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "34", "id": "2"}]}, {"id": "1ef66c97-ba82-600e-a2e0-03138fe681b4", "description": "Ventilador pulmonar de alta complejidad", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42272207-001", "description": "Ventilador pulmonar de alta complejidad", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42272207-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42272207", "description": "Ventiladores de alta frecuencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42272207"}], "quantity": 4, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 262043333, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba81-63de-a101-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "42", "id": "2"}]}, {"id": "1ef66c97-b9b5-6928-9d05-03138fe681b4", "description": "Balanza pediatrica", "classification": {"scheme": "catalogoNivel5DNCP", "id": "41111508-002", "description": "Balanza pediatrica", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/41111508-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "41111508", "description": "Basculas de medicion del peso corporal", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/41111508"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 2583333, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9b4-6a96-89b0-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "3", "id": "2"}]}, {"id": "1ef66c97-bab9-6522-ba16-03138fe681b4", "description": "Monitor multiparametrico", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181904-002", "description": "Monitor multiparametrico", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181904-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181904", "description": "Unidades de transporte o de senales vitales moviles de multiparametro o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181904"}], "quantity": 17, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 31650000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bab8-6884-80fb-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "53", "id": "2"}]}, {"id": "1ef66c97-ba2b-6182-bcf8-03138fe681b4", "description": "Cardiodesfibrilador", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42172101-003", "description": "Cardiodesfibrilador", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42172101-003"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42172101", "description": "Desfibriladores externos automatizados (AED) o paletas rigidas", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42172101"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 62000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba2a-6566-b221-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "25", "id": "2"}]}, {"id": "1ef66c97-b9f7-606c-95e7-03138fe681b4", "description": "Caja de Cirugia General", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9998", "description": "Caja de Cirugia General", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9998"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 17920933, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9f6-64dc-94f1-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "15", "id": "2"}]}, {"id": "1ef66c97-bb20-6240-9b8c-03138fe681b4", "description": "Sistema de Monitorizacion Holter", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181713-9999", "description": "Sistema de Monitorizacion Holter", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181713-9999"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181713", "description": "Sistemas de monitorizacion Holter", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181713"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 15150000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb1e-690e-b0a4-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "61", "id": "2"}]}, {"id": "1ef66c97-ba06-6788-848c-03138fe681b4", "description": "Caja de traumatologia y ortopedia", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-002", "description": "Caja de traumatologia y ortopedia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 44276667, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba05-6b30-96b2-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "18", "id": "2"}]}, {"id": "1ef66c97-bb38-6aa2-a29f-03138fe681b4", "description": "Transductor para ecografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42201711-001", "description": "Transductor para ecografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42201711-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42201711", "description": "Transductores ecograficos medicos de ultrasonidos, efecto Doppler o eco, o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42201711"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 41250000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb37-622e-9c94-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "64", "id": "2"}]}, {"id": "1ef66c97-ba86-6c4e-a6e0-03138fe681b4", "description": "Laringoscopio Adulto", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42272001-002", "description": "Laringoscopio Adulto", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42272001-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42272001", "description": "Laringoscopios o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42272001"}], "quantity": 8, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 3933333, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba86-6096-88a5-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "43", "id": "2"}]}, {"id": "1ef66c97-ba45-67f8-bdb5-03138fe681b4", "description": "Caja de Cirugia", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181515-004", "description": "Caja de Cirugia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181515-004"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181515", "description": "Bandejas de examen y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181515"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 26730000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba44-6c36-8d32-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "30", "id": "2"}]}, {"id": "1ef66c97-baa4-6b86-b156-03138fe681b4", "description": "Mesita de apoyo de cabecera / alimentacion del paciente", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42191901-001", "description": "Mesita de apoyo de cabecera / alimentacion del paciente", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42191901-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42191901", "description": "Muebles clinicos de cabecera o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42191901"}], "quantity": 9, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 1672222, "currency": "PYG"}}, "relatedLot": "1ef66c97-baa3-6fec-bf9d-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "49", "id": "2"}]}, {"id": "1ef66c97-ba40-680c-a96f-03138fe681b4", "description": "Caja de Cirugia", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181515-004", "description": "Caja de Cirugia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181515-004"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181515", "description": "Bandejas de examen y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181515"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 47466667, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba3f-6c40-8ab2-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "29", "id": "2"}]}, {"id": "1ef66c97-ba1b-6912-ad01-03138fe681b4", "description": "Camilla fija", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42192207-005", "description": "Camilla fija", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42192207-005"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42192207", "description": "Camillas de paciente o accesorios de camilla", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42192207"}], "quantity": 9, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 7599750, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba1a-6c24-a5b3-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "22", "id": "2"}]}, {"id": "1ef66c97-b9b0-61f8-9110-03138fe681b4", "description": "Balanza electronica digital con tallimetro", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42182805-9999", "description": "Balanza  Electronica Digital con Tallimetro", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42182805-9999"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42182805", "description": "Basculas de piso para pacientes", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42182805"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 275000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9af-650a-baeb-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "2", "id": "2"}]}, {"id": "1ef66c97-bb48-679a-8107-03138fe681b4", "description": "Transductor para ecografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42201711-001", "description": "Transductor para ecografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42201711-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42201711", "description": "Transductores ecograficos medicos de ultrasonidos, efecto Doppler o eco, o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42201711"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 44000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb47-6354-b58a-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "66", "id": "2"}]}, {"id": "1ef66c97-bb30-6780-933f-03138fe681b4", "description": "Transductor para ecografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42201711-001", "description": "Transductor para ecografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42201711-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42201711", "description": "Transductores ecograficos medicos de ultrasonidos, efecto Doppler o eco, o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42201711"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 41800000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb2f-601a-93dd-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "63", "id": "2"}]}, {"id": "1ef66c97-b9c0-6bf2-aa8e-03138fe681b4", "description": "Caja de Cirugia especializada", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9997", "description": "Caja de Cirugia Especializada", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9997"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 5, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 4500000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9bf-6f2c-bf46-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "5", "id": "2"}]}, {"id": "1ef66c97-ba35-6a7e-b968-03138fe681b4", "description": "Carro para curaciones", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42192404-001", "description": "Carro para curaciones", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42192404-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42192404", "description": "Carros medicos o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42192404"}], "quantity": 4, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 2416667, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba34-6e08-9fbf-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "27", "id": "2"}]}, {"id": "1ef702d7-ddd9-6904-a99a-9186720705fb", "description": "Set de Equipos odontologicos", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42151705-001", "description": "Set de Equipos odontologicos ", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42151705-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42151705", "description": "Sets de mobiliario combinado para tratamientos odontologicos", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42151705"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 34536170, "currency": "PYG"}}, "relatedLot": "1ef702d7-ddd8-6680-b15a-9186720705fb", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "60", "id": "2"}]}, {"id": "1ef66c97-ba8b-6ee2-9a2f-03138fe681b4", "description": "Maquina de anestesia", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42272504-007", "description": "Maquina de anestesia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42272504-007"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42272504", "description": "Equipos para anestesia y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42272504"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 364970667, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba8b-6276-9db9-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "44", "id": "2"}]}, {"id": "1ef66c97-ba10-6df0-8b3f-03138fe681b4", "description": "Cama electrica para paciente", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42191807-001", "description": "Cama electrica para paciente", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42191807-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42191807", "description": "Camas de cuidado del paciente o accesorios de uso general", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42191807"}], "quantity": 14, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 47666667, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba0f-6f68-a733-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "20", "id": "2"}]}, {"id": "1ef66c97-b9dc-6b40-9ec9-03138fe681b4", "description": "Caja de Cirugia especializada", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9997", "description": "Caja de Cirugia Especializada", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9997"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 130000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9db-6bb4-bed9-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "10", "id": "2"}]}, {"id": "1ef66c97-b9f2-6184-91c2-03138fe681b4", "description": "Caja de Cirugia General", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9998", "description": "Caja de Cirugia General", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9998"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 15491667, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9f1-6496-9f22-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "14", "id": "2"}]}, {"id": "1ef66c97-bb40-6388-985e-03138fe681b4", "description": "Transductor para ecografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42201711-001", "description": "Transductor para ecografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42201711-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42201711", "description": "Transductores ecograficos medicos de ultrasonidos, efecto Doppler o eco, o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42201711"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 44500000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb3e-6eca-8726-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "65", "id": "2"}]}, {"id": "1ef66c97-b9e2-627a-ac07-03138fe681b4", "description": "Caja de Cirugia especializada", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9997", "description": "Caja de Cirugia Especializada", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9997"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 30000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9e1-66a4-a72d-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "11", "id": "2"}]}, {"id": "1ef66c97-ba01-66e8-8c0e-03138fe681b4", "description": "Caja de Cirugia Pediatrica", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-003", "description": "Caja de cirugia pediatrica", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-003"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 70500000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba00-6b12-a289-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "17", "id": "2"}]}, {"id": "1ef66c97-bad2-6af4-ac65-03138fe681b4", "description": "Porta suero", "classification": {"scheme": "catalogoNivel5DNCP", "id": "41123403-003", "description": "Porta suero", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/41123403-003"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "41123403", "description": "Goteros de dosificacion y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/41123403"}], "quantity": 20, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 428333, "currency": "PYG"}}, "relatedLot": "1ef66c97-bace-63fa-a271-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "55", "id": "2"}]}, {"id": "1ef66c97-b9fc-6328-a8e9-03138fe681b4", "description": "Monitor multiparametrico", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181904-002", "description": "Monitor multiparametrico", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181904-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181904", "description": "Unidades de transporte o de senales vitales moviles de multiparametro o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181904"}], "quantity": 6, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 80958333, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9fb-6748-90c8-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "16", "id": "2"}]}, {"id": "1ef66c97-ba26-627c-bd37-03138fe681b4", "description": "Cardiodesfibrilador", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42172101-003", "description": "Cardiodesfibrilador", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42172101-003"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42172101", "description": "Desfibriladores externos automatizados (AED) o paletas rigidas", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42172101"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 75333333, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba25-661a-b623-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "24", "id": "2"}]}, {"id": "1ef66c97-baf6-6850-a99d-03138fe681b4", "description": "Tabla  para Diseccion", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42261705-999", "description": "Tabla para Diseccion", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42261705-999"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42261705", "description": "Mesas o accesorios de diseccion de animales para autopsia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42261705"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 311850000, "currency": "PYG"}}, "relatedLot": "1ef66c97-baf4-61fe-b041-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "57", "id": "2"}]}, {"id": "1ef66c97-ba68-6488-a7ee-03138fe681b4", "description": "Equipo de hemodialisis", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42161632-001", "description": "Equipo de hemodialisis", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42161632-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42161632", "description": "Unidad de hemodialisis y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42161632"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 136566667, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba67-683a-8b82-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "37", "id": "2"}]}, {"id": "1ef66c97-ba78-60cc-96f9-03138fe681b4", "description": "Estufa de secado", "classification": {"scheme": "catalogoNivel5DNCP", "id": "41104506-003", "description": "Estufa de secado", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/41104506-003"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "41104506", "description": "Estufas de seguridad de laboratorio", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/41104506"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 11835000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba77-6474-a7a4-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "40", "id": "2"}]}, {"id": "1ef66c97-ba0b-64e0-8189-03138fe681b4", "description": "Caja de curacion", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181515-002", "description": "Caja de curacion", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181515-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181515", "description": "Bandejas de examen y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181515"}], "quantity": 10, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 4400000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba0a-68ba-9cca-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "19", "id": "2"}]}, {"id": "1ef66c97-bb50-6be8-b674-03138fe681b4", "description": "Caja de Cirugia Especializada", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9997", "description": "Caja de Cirugia Especializada", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9997"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 187641350, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb4f-65ae-8700-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "67", "id": "2"}]}, {"id": "1ef66c97-b9a9-6c22-9d7a-03138fe681b4", "description": "Aspirador de Secreciones ", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42271907-001", "description": "Aspirador de secreciones", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42271907-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42271907", "description": "Productos o accesorios de aspirador respiratorio", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42271907"}], "quantity": 4, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 12625000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9a8-6354-903d-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "1", "id": "2"}]}, {"id": "1ef66c97-b9c6-6cb4-8925-03138fe681b4", "description": "Caja de Cirugia General", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9998", "description": "Caja de Cirugia General", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9998"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 3, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 15000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9c5-6fc6-b6d0-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "6", "id": "2"}]}, {"id": "1ef66c97-ba3b-673a-8aaa-03138fe681b4", "description": "Centrifuga", "classification": {"scheme": "catalogoNivel5DNCP", "id": "40161701-001", "description": "Centrifuga ", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/40161701-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "40161701", "description": "Centrifugas de laboratorio y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/40161701"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 4829000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba3a-6a10-9e0c-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "28", "id": "2"}]}, {"id": "1ef66c97-ba63-61b8-8ef3-03138fe681b4", "description": "Electrocardiografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181716-001", "description": "Electrocardiografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181716-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181716", "description": "Electrocardiografia (ECG) y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181716"}], "quantity": 6, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 30000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba62-65b0-b112-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "36", "id": "2"}]}, {"id": "1ef66c97-ba9f-69e2-ad8a-03138fe681b4", "description": "Mesa Quirurgica", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42295108-001", "description": "Mesa Quirurgica", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42295108-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42295108", "description": "Mesas de fractura de paciente de la sala de operacion o mesas ortopedicas o accesorios o productos relacionados", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42295108"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 184375000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba9e-6e20-90ac-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "48", "id": "2"}]}, {"id": "1ef66c97-b9e7-65a4-9a99-03138fe681b4", "description": "Caja de Cirugia especializada", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9997", "description": "Caja de Cirugia Especializada", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9997"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 40950000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9e6-6622-8433-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "12", "id": "2"}]}, {"id": "1ef66c97-ba6d-67c6-a50c-03138fe681b4", "description": "Equipo de rayos X portatil", "classification": {"scheme": "catalogoNivel5DNCP", "id": "41111808-002", "description": "Equipo de rayos X portatil", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/41111808-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "41111808", "description": "Equipo de examen por rayos X y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/41111808"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 533277000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba6c-6bf0-8bf9-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "38", "id": "2"}]}, {"id": "1ef66c97-b9ec-696e-b6b6-03138fe681b4", "description": "Caja de Cirugia", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181515-004", "description": "Caja de Cirugia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181515-004"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181515", "description": "Bandejas de examen y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181515"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 12316667, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9eb-6a6e-81a3-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "13", "id": "2"}]}, {"id": "1ef66c97-ba30-65ce-902c-03138fe681b4", "description": "Carro de paro", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42172101-004", "description": "Carro de paro", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42172101-004"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42172101", "description": "Desfibriladores externos automatizados (AED) o paletas rigidas", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42172101"}], "quantity": 6, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 11700000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba2f-69f8-a99d-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "26", "id": "2"}]}, {"id": "1ef66c97-bb02-6bf0-8b0c-03138fe681b4", "description": "Silla de rueda plegable", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42192210-001", "description": "Silla de rueda plegable", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42192210-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42192210", "description": "Sillas de ruedas", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42192210"}], "quantity": 20, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 1766667, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb00-6792-9037-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "58", "id": "2"}]}, {"id": "1ef66c97-bb28-6896-823f-03138fe681b4", "description": "Transductor para ecografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42201711-001", "description": "Transductor para ecografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42201711-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42201711", "description": "Transductores ecograficos medicos de ultrasonidos, efecto Doppler o eco, o accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42201711"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 41250000, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb27-63a6-89c4-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "62", "id": "2"}]}, {"id": "1ef66c97-ba16-66f6-a709-03138fe681b4", "description": "Cama electrica para paciente", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42191807-001", "description": "Cama electrica para paciente", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42191807-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42191807", "description": "Camas de cuidado del paciente o accesorios de uso general", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42191807"}], "quantity": 9, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 15783333, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba15-6a62-99c8-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "21", "id": "2"}]}, {"id": "1ef66c97-ba73-604a-9ae1-03138fe681b4", "description": "Estante para sala de esterilizacion", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42281515-9998", "description": "Estante para sala de esterilizacion", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42281515-9998"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42281515", "description": "Muebles de sala de esterilizacion", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42281515"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 7316619, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba72-603c-b0a3-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "39", "id": "2"}]}, {"id": "1ef66c97-bb0d-697e-a323-03138fe681b4", "description": "Silla Sanitaria", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42192103-9999", "description": "Silla Sanitaria", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42192103-9999"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42192103", "description": "Sillas de paciente", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42192103"}], "quantity": 6, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 1466667, "currency": "PYG"}}, "relatedLot": "1ef66c97-bb0b-6d04-9d2f-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "59", "id": "2"}]}, {"id": "1ef66c97-ba4f-69c4-9d30-03138fe681b4", "description": "Citoscopio", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42294801-034", "description": "Cistoscopio", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42294801-034"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42294801", "description": "Endoscopios o accesorios o productos relacionados", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42294801"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 40000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba4e-6e0c-b76e-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "32", "id": "2"}]}, {"id": "1ef66c97-b9d7-6460-be6a-03138fe681b4", "description": "Caja de Cirugia Menor", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9999", "description": "Caja de Cirugia Menor", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9999"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 35000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9d6-6772-b15e-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "9", "id": "2"}]}, {"id": "1ef66c97-babe-6edc-a80b-03138fe681b4", "description": "Nefroscopio", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42142708-9999", "description": "Nefroscopio", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42142708-9999"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42142708", "description": "Instrumentos urologicos", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42142708"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 115885000, "currency": "PYG"}}, "relatedLot": "1ef66c97-babd-6dca-b3c5-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "54", "id": "2"}]}, {"id": "1ef66c97-bae5-6e10-abc9-03138fe681b4", "description": "Incubadora  Servocuna", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42191802-9999", "description": "Incubadora + Servocuna", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42191802-9999"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42191802", "description": "Incubadoras clinicas o calentadores de bebe y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42191802"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 108666667, "currency": "PYG"}}, "relatedLot": "1ef66c97-bae2-6c74-8406-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "56", "id": "2"}]}, {"id": "1ef66c97-ba54-6744-b576-03138fe681b4", "description": "Ecocardiografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181716-002", "description": "Ecocardiografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181716-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181716", "description": "Electrocardiografia (ECG) y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181716"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 455000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba53-6b96-a2c5-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "33", "id": "2"}]}, {"id": "1ef66c97-bab4-6626-9601-03138fe681b4", "description": "Monitor cardiofetal", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181901-001", "description": "Monitor cardiofetal", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181901-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181901", "description": "Unidades de monitorizacion materna o fetal de tratamiento agudo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181901"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 32883333, "currency": "PYG"}}, "relatedLot": "1ef66c97-bab3-6a32-8e42-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "52", "id": "2"}]}, {"id": "1ef66c97-baaf-61da-aa03-03138fe681b4", "description": "Microscopios de fluorescencia", "classification": {"scheme": "catalogoNivel5DNCP", "id": "41111722-001", "description": "Microscopios de fluorescencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/41111722-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "41111722", "description": "Microscopios de fluorescencia y Accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/41111722"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 113219500, "currency": "PYG"}}, "relatedLot": "1ef66c97-baae-65be-9437-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "51", "id": "2"}]}, {"id": "1ef66c97-ba4a-6956-aa26-03138fe681b4", "description": "Set para cirugia laparoscopica", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42294805-003", "description": "Set para cirugia laparoscopica", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42294805-003"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42294805", "description": "Laparoscopios o telescopios laparoscopicos", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42294805"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 100333333, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba49-6d4e-81da-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "31", "id": "2"}]}, {"id": "1ef66c97-ba5e-612c-8b0a-03138fe681b4", "description": "Ecografo", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42201718-001", "description": "Ecografo", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42201718-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42201718", "description": "Ecografos y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42201718"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 236400000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba5d-657e-a55b-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "35", "id": "2"}]}, {"id": "1ef66c97-b9cc-6416-9b4c-03138fe681b4", "description": "Caja de Cirugia", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42181515-004", "description": "Caja de Cirugia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42181515-004"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42181515", "description": "Bandejas de examen y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181515"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 140000000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9cb-6836-aaf2-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "7", "id": "2"}]}, {"id": "1ef66c97-baaa-600e-b2f1-03138fe681b4", "description": "Microscopio Optico", "classification": {"scheme": "catalogoNivel5DNCP", "id": "41111710-001", "description": "Microscopio Optico", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/41111710-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "41111710", "description": "Microscopios electronicos y opticos combinados", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/41111710"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 150437500, "currency": "PYG"}}, "relatedLot": "1ef66c97-baa9-6460-89f5-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "50", "id": "2"}]}, {"id": "1ef66c97-ba9a-6a3c-922f-03138fe681b4", "description": "Mesa de Instrumental", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42295112-002", "description": "Mesa de instrumental", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42295112-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42295112", "description": "Mesas de procedimiento de la sala de operacion o accesorios o productos relacionados", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42295112"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 3820000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba99-6e70-99a5-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "47", "id": "2"}]}, {"id": "1ef66c97-ba20-6ed0-baf2-03138fe681b4", "description": "Camilla con ruedas", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42192207-001", "description": "Camilla con ruedas", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42192207-001"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42192207", "description": "Camillas de paciente o accesorios de camilla", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42192207"}], "quantity": 5, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 6948333, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba20-6296-be3b-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "23", "id": "2"}]}, {"id": "1ef66c97-b9d1-6dbc-9a79-03138fe681b4", "description": "Caja de Cirugia Menor", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42171910-9999", "description": "Caja de Cirugia Menor", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42171910-9999"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42171910", "description": "Cajas paramedicas de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171910"}], "quantity": 5, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 2200000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9d0-6ed0-a4fa-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "8", "id": "2"}]}, {"id": "1ef66c97-b9bb-6166-8092-03138fe681b4", "description": "Biometro", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42183023-008", "description": "Biometro ", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42183023-008"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42183023", "description": "Oftalmometros", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42183023"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 318750000, "currency": "PYG"}}, "relatedLot": "1ef66c97-b9ba-65ae-ad97-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "4", "id": "2"}]}, {"id": "1ef66c97-ba7d-6310-bfa5-03138fe681b4", "description": "Lampara cialitica con satelite", "classification": {"scheme": "catalogoNivel5DNCP", "id": "39101602-002", "description": "Lampara cialitica con satelite", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/39101602-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "39101602", "description": "Lamparas medicas y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/39101602"}], "quantity": 2, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 206500000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba7c-6780-a897-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "41", "id": "2"}]}, {"id": "1ef66c97-ba90-694c-86ab-03138fe681b4", "description": "Maquina de anestesia", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42272504-007", "description": "Maquina de anestesia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42272504-007"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42272504", "description": "Equipos para anestesia y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42272504"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 382650000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba8f-6dd0-9052-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "45", "id": "2"}]}, {"id": "1ef66c97-ba95-6b90-a3dc-03138fe681b4", "description": "Mesa de instrumental ", "classification": {"scheme": "catalogoNivel5DNCP", "id": "42295112-002", "description": "Mesa de instrumental", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n5/42295112-002"}, "additionalClassifications": [{"scheme": "UNSPSC", "id": "42295112", "description": "Mesas de procedimiento de la sala de operacion o accesorios o productos relacionados", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42295112"}], "quantity": 1, "unit": {"name": "Unidad", "id": "UNI", "value": {"amount": 2033000, "currency": "PYG"}}, "relatedLot": "1ef66c97-ba94-6fba-aac5-03138fe681b4", "attributes": [{"name": "Presentacion", "value": "UNIDAD", "id": "1"}, {"name": "Orden", "value": "46", "id": "2"}]}], "tenderers": [{"name": "VICENTE SCAVONE & CIA. S.A.E", "id": "PY-RUC-80001446-4"}, {"name": "SOLUMEDIC S.A.", "id": "PY-RUC-80023913-0"}, {"name": "SUMI SOCIEDAD ANONIMA", "id": "PY-RUC-80068800-7"}, {"name": "DYSA HEALTHCARE S.A.", "id": "PY-RUC-80013820-1"}, {"name": "LCM SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80011068-4"}, {"name": "SURVYCON S.A. SURVEY & CONTROL", "id": "PY-RUC-80063377-6"}, {"name": "IN SITU S.A.", "id": "PY-RUC-80027373-7"}, {"name": "IMESE S.A.", "id": "PY-RUC-80016426-1"}, {"name": "ARGON S.R.L.", "id": "PY-RUC-80004373-1"}, {"name": "CATETERES Y AFINES S.A.", "id": "PY-RUC-80030030-0"}, {"name": "ALBATROS SACI", "id": "PY-RUC-80002766-3"}, {"name": "MACRO SCIENCE SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80064898-6"}, {"name": "ANDRES H. ARCE SA", "id": "PY-RUC-80023488-0"}, {"name": "GAESA SA", "id": "PY-RUC-80026596-3"}, {"name": "BIOERIX S.A. ", "id": "PY-RUC-80051821-7"}], "documents": [{"id": "b8b34f78-bae6-4cfe-963e-6cbdb2a1d07e", "datePublished": "2024-08-21T11:45:46-04:00", "title": "cdp-lpn-21-2024-66c60b81dab58.pdf", "url": "https://www.contrataciones.gov.py/api/convocatorias/1ef5fba1-ce71-61f8-8818-a11be0626a70/files/b8b34f78-bae6-4cfe-963e-6cbdb2a1d07e/download", "language": "es", "documentTypeDetails": "CDP"}, {"id": "lCs6IgRDU2E=", "datePublished": "2024-09-25T19:36:14-04:00", "title": "Pliego para la Adquisici\u00f3n de Bienes y/o Servicios - CONVENCIONAL - Ley N\u00ba 7021/22. 443857 Version 3", "url": "https://www.contrataciones.gov.py/documentos/download/pliego/1ef5fba1-ce71-61f8-8818-a11be0626a70/3", "language": "es", "documentType": "biddingDocuments", "documentTypeDetails": "Pliego Electr\u00f3nico de bases y Condiciones", "format": "application/pdf"}, {"id": "86c6ed57-cbab-4bbe-8f8f-7ef833d5143d", "datePublished": "2024-10-04T10:39:45-04:00", "title": "aper-lpn-21-2024-30715792664373671-66fffe3075063.pdf", "url": "https://www.contrataciones.gov.py/api/convocatorias/1ef5fba1-ce71-61f8-8818-a11be0626a70/files/86c6ed57-cbab-4bbe-8f8f-7ef833d5143d/download", "language": "es", "documentTypeDetails": "Acta de Apertura"}, {"id": "dix2iRRDbik=", "title": "URL de la Convocatoria", "url": "https://www.contrataciones.gov.py/licitaciones/convocatoria/1ef5fba1-ce71-61f8-8818-a11be0626a70.html", "language": "es", "documentType": "tenderNotice", "format": "text/html"}, {"id": "bea07869-cc89-42e3-8f38-397be9fe5366", "datePublished": "2024-08-21T11:45:46-04:00", "title": "anticipo-lpn-21-2024-66c6028e4dce7.pdf", "url": "https://www.contrataciones.gov.py/api/convocatorias/1ef5fba1-ce71-61f8-8818-a11be0626a70/files/bea07869-cc89-42e3-8f38-397be9fe5366/download", "language": "es", "documentTypeDetails": "Dictamen de justificaci\u00f3n de Anticipo"}, {"id": "6d05a0a9-0f20-4903-9f8a-b53a33158f48", "datePublished": "2024-08-21T11:45:46-04:00", "title": "reso-lpn-21-2024-66c6022080b27.pdf", "url": "https://www.contrataciones.gov.py/api/convocatorias/1ef5fba1-ce71-61f8-8818-a11be0626a70/files/6d05a0a9-0f20-4903-9f8a-b53a33158f48/download", "language": "es", "documentTypeDetails": "Aprobaci\u00f3n PBC"}, {"id": "ec62c1dd-a27c-45be-8692-6bde6e9d2376", "datePublished": "2024-08-21T11:45:46-04:00", "title": "dictamen-precios-lpn-21-2024-2-66c60269cce9e.pdf", "url": "https://www.contrataciones.gov.py/api/convocatorias/1ef5fba1-ce71-61f8-8818-a11be0626a70/files/ec62c1dd-a27c-45be-8692-6bde6e9d2376/download", "language": "es", "documentTypeDetails": "Antecedentes de la Estimaci\u00f3n de Costos"}, {"id": "19e1846e-554d-4805-a943-b0e7333cbbd8", "datePublished": "2024-08-21T11:45:46-04:00", "title": "dictamen-tecnico-lpn-21-2024-66c60235681a1.pdf", "url": "https://www.contrataciones.gov.py/api/convocatorias/1ef5fba1-ce71-61f8-8818-a11be0626a70/files/19e1846e-554d-4805-a943-b0e7333cbbd8/download", "language": "es", "documentTypeDetails": "Dictamen t\u00e9cnico"}, {"id": "7aa25488-7b10-475d-b0ce-3f26dc1d4a95", "datePublished": "2024-08-21T11:45:46-04:00", "title": "dictamen-precios-lpn-21-2024-1-66c602575ed86.pdf", "url": "https://www.contrataciones.gov.py/api/convocatorias/1ef5fba1-ce71-61f8-8818-a11be0626a70/files/7aa25488-7b10-475d-b0ce-3f26dc1d4a95/download", "language": "es", "documentTypeDetails": "Antecedentes de la Estimaci\u00f3n de Costos"}, {"id": "7RdSAitlcLBILNW4rrVbuw==", "datePublished": "2024-09-25T19:36:14-04:00", "title": "Pliego para la Adquisici\u00f3n de Bienes y/o Servicios - CONVENCIONAL - Ley N\u00ba 7021/22. 443857 Version 3", "url": "https://www.contrataciones.gov.py/documentos/download/pliego/1ef5fba1-ce71-61f8-8818-a11be0626a70/3/json", "language": "es", "documentType": "biddingDocuments", "documentTypeDetails": "Pliego Electr\u00f3nico de bases y Condiciones", "format": "application/json"}], "numberOfTenderers": 15}, "language": "es", "ocid": "ocds-03ad3f-443857-1", "date": "2025-04-14T09:05:39-04:00", "initiationType": "tender", "buyer": {"id": "DNCP-SICP-CODE-226", "name": "Universidad Nacional de Asunci\u00f3n (UNA)"}, "sources": [{"id": "dncp-sicp", "name": "Sistema de Informaci\u00f3n de las Contrataciones P\u00fablicas - DNCP", "url": "https://www.contrataciones.gov.py/"}], "contracts": [{"id": "LP-28001-24-246514", "amendments": [{"date": "2024-11-29T00:00:00-04:00", "description": "Ampliaci\u00f3n de Monto", "amendsAmount": {"amount": 326791000, "currency": "PYG"}, "id": "1efae62b-abbd-6f34-8783-3d2011b93bd7", "financialCode": "AC-28001-24-248637"}], "implementation": {"financialProgress": {"breakdown": [{"id": "2024/28/1/1/1/0/4/4/11/535/20/LP-28001-24-246514", "period": {"startDate": "2024-01-01T00:00:00Z", "endDate": "2024-12-31T00:00:00Z"}, "measures": {"monto_a_utilizar": 9600000000}, "classifications": {"anio": "2024", "nivel": "28", "entidad": "1", "tipo_programa": "1", "programa": "1", "sub_programa": "0", "proyecto": "4", "financiador": "4", "departamento": "11", "objeto_gasto": "535", "fuente_financiamiento": "20", "cdp": "1307"}, "financialCode": "LP-28001-24-246514"}]}, "transactions": [{"id": "SIAF+LP-28001-24-246514+001-001-0004145+4347906", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 12153281}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "LCM SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80011068-4"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0004145", "bill": {"id": "001-001-0004145", "type": "FACTURA", "date": "2024-11-28T00:00:00-04:00", "amount": {"amount": 13040000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 474182, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 45521, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 355636, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246514"}, {"id": "SIAF+LP-28001-24-246514+001-001-0004362+4363679", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 1652771519}, "date": "2025-01-08T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "LCM SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80011068-4"}, "requestDate": "2024-12-27T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0004362", "bill": {"id": "001-001-0004362", "type": "FACTURA", "date": "2024-12-17T00:00:00-04:00", "amount": {"amount": 1773360000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 64485818, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 6190639, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 48364364, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246514"}, {"id": "SIAF+LP-28001-24-246514+001-001-0004363+4358975", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 215180302}, "date": "2024-12-27T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "LCM SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80011068-4"}, "requestDate": "2024-12-23T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0004363", "bill": {"id": "001-001-0004363", "type": "FACTURA", "date": "2024-12-17T00:00:00-04:00", "amount": {"amount": 230963200, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 8398662, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 806272, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 6298996, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246514"}, {"id": "SIAF+LP-28001-24-246514+001-001-0003891+4347899", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 113973348}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "LCM SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80011068-4"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0003891", "bill": {"id": "001-001-0003891", "type": "FACTURA", "date": "2024-11-05T00:00:00-04:00", "amount": {"amount": 122289000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 4446873, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 426900, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 3335155, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246514"}, {"id": "SIAF+LP-28001-24-246514+001-001-0003893+4347900", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 53814426}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "LCM SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80011068-4"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0003893", "bill": {"id": "001-001-0003893", "type": "FACTURA", "date": "2024-11-05T00:00:00-04:00", "amount": {"amount": 57740800, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 2099665, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 201568, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 1574749, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246514"}, {"id": "SIAF+LP-28001-24-246514+001-001-0004360+4363678", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 992647103}, "date": "2025-01-08T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "LCM SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80011068-4"}, "requestDate": "2024-12-27T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0004360", "bill": {"id": "001-001-0004360", "type": "FACTURA", "date": "2024-12-17T00:00:00-04:00", "amount": {"amount": 1065072000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 38729891, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 3718070, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 29047418, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246514"}, {"id": "SIAF+LP-28001-24-246514+001-001-0004144+4347905", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 22025025}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "LCM SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80011068-4"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0004144", "bill": {"id": "001-001-0004144", "type": "FACTURA", "date": "2024-11-28T00:00:00-04:00", "amount": {"amount": 23632000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 859345, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 82497, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 644509, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246514"}, {"id": "SIAF+LP-28001-24-246514+001-001-0004109+4347902", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 721580496}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "LCM SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80011068-4"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0004109", "bill": {"id": "001-001-0004109", "type": "FACTURA", "date": "2024-11-26T00:00:00-04:00", "amount": {"amount": 774228000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 28153745, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 2702760, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 21115309, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246514"}, {"id": "SIAF+LP-28001-24-246514+001-001-0004111+4363677", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 93945600}, "date": "2025-01-08T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "LCM SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80011068-4"}, "requestDate": "2024-12-27T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0004111", "bill": {"id": "001-001-0004111", "type": "FACTURA", "date": "2024-11-26T00:00:00-04:00", "amount": {"amount": 100800000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 3665455, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 351884, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 2749091, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246514"}, {"id": "SIAF+LP-28001-24-246514+001-001-0003884+4347898", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 185901380}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "LCM SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80011068-4"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0003884", "bill": {"id": "001-001-0003884", "type": "FACTURA", "date": "2024-11-05T00:00:00-04:00", "amount": {"amount": 199465000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 7253273, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 696314, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 5439955, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246514"}, {"id": "SIAF+LP-28001-24-246514+001-001-0003894+4347901", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 684841057}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "LCM SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80011068-4"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0003894", "bill": {"id": "001-001-0003894", "type": "FACTURA", "date": "2024-11-05T00:00:00-04:00", "amount": {"amount": 734808000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 26720291, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 2565148, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 20040218, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246514"}, {"id": "SIAF+LP-28001-24-246514+001-001-0004143+4347904", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 380256000}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "LCM SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80011068-4"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0004143", "bill": {"id": "001-001-0004143", "type": "FACTURA", "date": "2024-11-28T00:00:00-04:00", "amount": {"amount": 408000000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 14836364, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 1424291, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 11127273, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246514"}, {"id": "SIAF+LP-28001-24-246514+001-001-0004110+4347903", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 63484113}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "LCM SOCIEDAD AN\u00d3NIMA", "id": "PY-RUC-80011068-4"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0004110", "bill": {"id": "001-001-0004110", "type": "FACTURA", "date": "2024-11-26T00:00:00-04:00", "amount": {"amount": 68116000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 2476945, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 237787, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 1857709, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246514"}]}, "awardID": "1ef8bc53-1543-618e-9005-ab792174d300", "status": "active", "statusDetails": "publicado", "period": {"startDate": "2024-11-01T00:00:00-04:00"}, "value": {"amount": 5571514000, "currency": "PYG"}, "documents": [{"id": "1efa3660-3fc2-6620-9172-0b73765ac33d", "datePublished": "2024-11-15T12:26:42-04:00", "title": "7-anexo-b-02-05-solumedicfirmado-67376831f3d99.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/ec4f3e12-d693-4a2c-b870-2fa129739cea/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3660-700f-667a-a8e4-0f67ac9bbc31", "datePublished": "2024-11-15T12:26:47-04:00", "title": "8-anexo-b-02-17-argonfirmado-673768370ae7b.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/68ea26f1-4b36-4580-b6c6-fa9ad2d88019/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0d8-13eb-6882-ba92-f3c7bb481882", "datePublished": "2024-11-07T10:38:00-04:00", "title": "expediente-de-mesa-de-entrada-dncp-n-13204-rv-nota-una-fcm-daf-dcp-n-2342-2024-672cc2b7e84dc.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/5908b4a7-992b-401f-a523-3228a7380ec5/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef983d9-4f29-60b2-898f-17396becb01a", "datePublished": "2024-11-01T07:39:33-04:00", "title": "resol-d-n-182-adm-de-contratos-001-6724afe5098eb.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/c36c59bd-2c7f-4dec-96b6-c28f70894aee/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1ef9d0d8-4cae-6bba-a5b0-1f20c47f9f09", "datePublished": "2024-11-07T10:38:05-04:00", "title": "chat-equipos-672cc2bde07cf.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/d6b15752-e6f3-4aa5-bcec-26d5cdb7c23d/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa365f-bab1-618e-a71f-cb897065ef3e", "datePublished": "2024-11-15T12:26:28-04:00", "title": "5-infor-eva-comp-02-lpn-21-24-673768238d31c.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/92b4a958-10a0-484b-af7a-2f54e46a3d51/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa365e-f13a-6274-9720-f3e1fa285666", "datePublished": "2024-11-15T12:26:06-04:00", "title": "2-respuesta-sobre-el-expediente-13204-equipos-medicos-6737680ee32fa.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/322ddaa0-0d94-48b3-b315-ce2d1eed489f/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef983d9-e7f5-6b60-9415-7f5dbca05ad2", "datePublished": "2024-11-01T07:39:49-04:00", "title": "cdp-lpn-n-21-2024-6724aff50afd0.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/8e8c4c7d-2405-4d07-8d77-78de99e4d147/download", "language": "es", "documentTypeDetails": "CDP"}, {"id": "1efa365f-22a0-65fc-85d2-ef1a541be196", "datePublished": "2024-11-15T12:26:12-04:00", "title": "3-notificacion-de-adjudicacion-complementaria-n-2-6737681416e93.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/2960cec2-9930-4238-b31c-8eae0020b367/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3660-d5ab-6b1e-8da1-77f79783a44a", "datePublished": "2024-11-15T12:26:57-04:00", "title": "10-cco-lpn-21-2024-comp2-67376841a3955.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/1a0630ee-d21c-4673-8f18-70c2169c6064/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0d8-b7c2-6654-9344-ed5ee3f6b105", "datePublished": "2024-11-07T10:38:17-04:00", "title": "nota-dncp-lpn-21-2024-comp2-exp-672cc2c8a984a.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/adfc89c2-be63-463f-a909-95beb2deee8d/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa365f-52c8-6d38-a40d-85956befd8da", "datePublished": "2024-11-15T12:26:17-04:00", "title": "4-resol-d-n-1873-2024-eval-compl-n-02-lpn-n-21-024-673768191e622.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/f6523f5b-c164-44ec-b992-f98a82908bb5/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3660-9e95-6396-86c7-fdbe8d1b5d20", "datePublished": "2024-11-15T12:26:52-04:00", "title": "9-anexo-b-02-17-solumedicfirmado-6737683be203c.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/f40cfc0e-a1ae-4121-ab8f-06501f6f09c0/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef983da-5216-66c0-a34e-113fc36d22d3", "datePublished": "2024-11-01T07:40:00-04:00", "title": "contrato-form-n-170-2024-lcm-s-a-lpn-n-21-2024-6724b0002d35f.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/450e1cd1-02fa-408d-a578-9f1e1dc2c282/download", "language": "es", "documentType": "contractSigned", "documentTypeDetails": "Contrato"}, {"id": "1ef9d0d7-d72d-6d28-a9e4-7926aa4ea81d", "datePublished": "2024-11-07T10:37:53-04:00", "title": "nota-n-2427-2024-reparo-lpn-21-2024firmado-672cc2b18e02b.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/4ef379aa-ce06-4c7b-995f-631b5353182c/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa365e-b7e4-64de-b183-c7afdfec0526", "datePublished": "2024-11-15T12:26:00-04:00", "title": "1-nota-n-2502-2024-reparo-lpn-21-2024firmado-67376808d2c3b.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/2d67fc21-8b3c-4b72-873e-5446f04c37fa/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3661-006d-66fe-aee5-67af094c76ea", "datePublished": "2024-11-15T12:27:02-04:00", "title": "11-cpa-lpn-21-2024-comp2-673768463234f.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/3339034f-57a9-40eb-8d76-b9d7c9471106/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3660-0965-6b2c-b55d-91b42ac90dc7", "datePublished": "2024-11-15T12:26:36-04:00", "title": "6-anexo-b-02-05-argonfirmado-6737682c4168a.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc53-1543-618e-9005-ab792174d300/files/3de0c7b6-07fb-46f4-9e71-ad811cbf7554/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}]}, {"id": "LP-28001-24-246517", "implementation": {"financialProgress": {"breakdown": [{"id": "2024/28/1/1/1/0/4/4/11/535/20/LP-28001-24-246517", "period": {"startDate": "2024-01-01T00:00:00Z", "endDate": "2024-12-31T00:00:00Z"}, "measures": {"monto_a_utilizar": 9600000000}, "classifications": {"anio": "2024", "nivel": "28", "entidad": "1", "tipo_programa": "1", "programa": "1", "sub_programa": "0", "proyecto": "4", "financiador": "4", "departamento": "11", "objeto_gasto": "535", "fuente_financiamiento": "20", "cdp": "1307"}, "financialCode": "LP-28001-24-246517"}]}, "transactions": [{"id": "SIAF+LP-28001-24-246517+001-003-0000321+4347863", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 290318000}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "IN SITU S.A.", "id": "PY-RUC-80027373-7"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-003-0000321", "bill": {"id": "001-003-0000321", "type": "FACTURA", "date": "2024-11-07T00:00:00-04:00", "amount": {"amount": 311500000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 11327273, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 1087418, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 8495455, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246517"}]}, "awardID": "1ef8bca8-b51b-68c8-91a9-592e0c6845ae", "status": "active", "statusDetails": "publicado", "period": {"startDate": "2024-10-29T00:00:00-04:00"}, "value": {"amount": 311500000, "currency": "PYG"}, "documents": [{"id": "1ef9d0d4-f11f-60e0-bac3-dbf69465e1ca", "datePublished": "2024-11-07T10:36:35-04:00", "title": "expediente-de-mesa-de-entrada-dncp-n-13204-rv-nota-una-fcm-daf-dcp-n-2342-2024-672cc263bd889.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/d45ec3db-d565-43f6-bd3b-2c7f4e4c089a/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa365a-9b48-6f04-aa2f-61b24f39abe2", "datePublished": "2024-11-15T12:24:10-04:00", "title": "1-nota-n-2502-2024-reparo-lpn-21-2024firmado-6737679a81960.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/237672cb-64ab-4752-b7f5-f56cd0a15f04/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa365c-9958-6ee0-b8ce-45683f639790", "datePublished": "2024-11-15T12:25:04-04:00", "title": "7-anexo-b-02-05-solumedicfirmado-673767d000892.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/2fa4252b-6393-432c-a99d-0eae412f80e0/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa365b-001c-67d2-a7da-0da2bad17cf7", "datePublished": "2024-11-15T12:24:21-04:00", "title": "3-notificacion-de-adjudicacion-complementaria-n-2-673767a51989e.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/500ac23b-e3e6-4037-86bb-5d57869bc4be/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa365c-65f3-6528-abec-9fb35da04a9a", "datePublished": "2024-11-15T12:24:58-04:00", "title": "6-anexo-b-02-05-argonfirmado-673767ca93f62.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/40ef0fca-bc30-4c39-b814-90a11b28b963/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0d5-2311-6dd2-9d82-7d772a113671", "datePublished": "2024-11-07T10:36:41-04:00", "title": "chat-equipos-672cc26902573.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/0e1e65e9-5575-401e-bbbe-f599a009c845/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0d5-8e26-6e4c-b9cd-475fb729d22a", "datePublished": "2024-11-07T10:36:52-04:00", "title": "nota-dncp-lpn-21-2024-comp2-exp-672cc273bddc6.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/70bd29d7-8e66-4fda-9b64-18016b048d29/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa365d-2d32-6f12-9057-d1924cf1d119", "datePublished": "2024-11-15T12:25:19-04:00", "title": "10-cco-lpn-21-2024-comp2-673767df7e083.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/66e770f3-c0fa-4272-8a4d-56a9c771274d/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa365c-ca0e-63fa-8bc4-9b2d497e9edc", "datePublished": "2024-11-15T12:25:09-04:00", "title": "8-anexo-b-02-17-argonfirmado-673767d520aa8.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/4b3fbb8f-f997-4ac4-8a50-bee8e5565ec9/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa365a-c76f-63d0-bd85-7902a94494f4", "datePublished": "2024-11-15T12:24:15-04:00", "title": "2-respuesta-sobre-el-expediente-13204-equipos-medicos-6737679f2443a.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/0fd97b4d-553a-4bb9-8eb5-d21317854918/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef95eea-580c-6a26-aed2-25b16a7c713f", "datePublished": "2024-10-29T09:09:28-04:00", "title": "contrato-form-n-169-2024-in-situ-s-a-lpn-n-21-2024-6720d07836669.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/00850912-3cf7-4874-8f1c-4a887aeb21c4/download", "language": "es", "documentType": "contractSigned", "documentTypeDetails": "Contrato"}, {"id": "1efa365c-fc68-66c0-8310-87a152ab64cf", "datePublished": "2024-11-15T12:25:14-04:00", "title": "9-anexo-b-02-17-solumedicfirmado-673767da5c107.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/f16a1a78-6a18-446e-91fa-969dc7c6bded/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef95eeb-b4ca-676c-8380-a1eb2b58bd1b", "datePublished": "2024-10-29T09:10:04-04:00", "title": "resol-d-n-182-adm-de-contratos-001-6720d09cc69f1.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/52c2ff4c-1cad-4f28-b92b-f3af7e8f2984/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa365d-5a30-6ac8-8c9e-83b60b6eedac", "datePublished": "2024-11-15T12:25:24-04:00", "title": "11-cpa-lpn-21-2024-comp2-673767e43d265.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/7269860a-2837-49c8-93ad-89ad9776a0c1/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef95eea-fa50-61b6-8b0e-ad5b613b5505", "datePublished": "2024-10-29T09:09:45-04:00", "title": "cdp-lpn-n-21-2024-6720d0893916f.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/ed79138d-7444-46ac-a8ab-0a00d6216be3/download", "language": "es", "documentTypeDetails": "CDP"}, {"id": "1ef9d0d4-a593-6edc-9a6a-f3612fa37167", "datePublished": "2024-11-07T10:36:27-04:00", "title": "nota-n-2427-2024-reparo-lpn-21-2024firmado-672cc25bcc310.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/b18c8e3d-51f5-413f-96f2-b6e5686fb9c9/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa365b-2fa6-6d72-ab2a-8ddc656a9281", "datePublished": "2024-11-15T12:24:26-04:00", "title": "4-resol-d-n-1873-2024-eval-compl-n-02-lpn-n-21-024-673767aa1164f.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/6123fe64-14bb-4187-bcc3-193fcbf8cf84/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa365b-8453-6b2c-9694-831c18c43cb7", "datePublished": "2024-11-15T12:24:35-04:00", "title": "5-infor-eva-comp-02-lpn-21-24-673767b2a27f6.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/91aa1140-7f0f-4c43-85db-a6bf8428d753/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef95eeb-60a8-67c4-a777-93262543f4e7", "datePublished": "2024-10-29T09:09:56-04:00", "title": "notificacion-adjudicacion-lpn-n-21-2024-6720d093ef1dc.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca8-b51b-68c8-91a9-592e0c6845ae/files/d433cea1-566b-4dcc-9421-4d23b78f524a/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}]}, {"id": "LP-28001-24-246510", "implementation": {"financialProgress": {"breakdown": [{"id": "2024/28/1/1/1/0/4/4/11/535/20/LP-28001-24-246510", "period": {"startDate": "2024-01-01T00:00:00Z", "endDate": "2024-12-31T00:00:00Z"}, "measures": {"monto_a_utilizar": 9600000000}, "classifications": {"anio": "2024", "nivel": "28", "entidad": "1", "tipo_programa": "1", "programa": "1", "sub_programa": "0", "proyecto": "4", "financiador": "4", "departamento": "11", "objeto_gasto": "535", "fuente_financiamiento": "20", "cdp": "1307"}, "financialCode": "LP-28001-24-246510"}]}, "transactions": [{"id": "SICP+LP-28001-24-246510+0010010003714+4387999", "sourceSystem": "SICP", "value": {"currency": "PYG", "amount": 62232923}, "date": "2025-01-30T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "DYSA HEALTHCARE S.A.", "id": "PY-RUC-80013820-1"}, "requestDate": "2025-01-30T00:00:00-04:00", "finantialObligations": [{"id": "0010010003714", "bill": {"id": "0010010003714", "type": "FACTURA", "date": "2024-12-05T00:00:00-04:00", "amount": {"amount": 66863200, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 1823542, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 2431389, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 83579, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 233413, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 1823542, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246510"}, {"id": "SIAF+LP-28001-24-246510+001-001-0003354+4347529", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 15579127}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "DYSA HEALTHCARE S.A.", "id": "PY-RUC-80013820-1"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0003354", "bill": {"id": "001-001-0003354", "type": "FACTURA", "date": "2024-11-07T00:00:00-04:00", "amount": {"amount": 16715800, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 607847, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 58353, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 455885, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246510"}]}, "awardID": "1ef8bc05-8114-6cda-9693-99740a454274", "status": "active", "statusDetails": "publicado", "period": {"startDate": "2024-11-01T00:00:00-04:00"}, "value": {"amount": 83579000, "currency": "PYG"}, "documents": [{"id": "1efa3655-2def-6bce-8040-f3706952e7b2", "datePublished": "2024-11-15T12:21:44-04:00", "title": "8-anexo-b-02-17-argonfirmado-67376708cd41c.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/2122f374-db18-42bc-a284-6a717d2cfbc8/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3653-5b14-6e6c-9beb-bdf31af3fa8a", "datePublished": "2024-11-15T12:20:55-04:00", "title": "4-resol-d-n-1873-2024-eval-compl-n-02-lpn-n-21-024-673766d7d4dce.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/51b331dc-65dd-4079-af33-5d724811e2a1/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0d0-5beb-65cc-9d9b-2588450efe3c", "datePublished": "2024-11-07T10:34:32-04:00", "title": "notificacion-adjudicacion-lpn-n-21-2024-672cc1e8bba1a.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/2bfd402a-2498-4e5f-9d5a-1c036eb5d7cd/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3652-bb00-6c1e-a249-532aff0a2ba5", "datePublished": "2024-11-15T12:20:39-04:00", "title": "1-nota-n-2502-2024-reparo-lpn-21-2024firmado-673766c71955d.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/021d118e-fe2b-4157-bceb-538c782254f2/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9841b-5acf-696a-ba55-27f3387d1dea", "datePublished": "2024-11-01T08:09:06-04:00", "title": "contrato-form-n-167-2024-dysa-healthcare-s-a-lpn-21-24-6724b6d1ddf73.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/ded13ecd-5ed8-42f7-985c-28ad049af0ec/download", "language": "es", "documentType": "contractSigned", "documentTypeDetails": "Contrato"}, {"id": "1efa3652-eab0-6b44-b3c7-fd2e7b7a94c7", "datePublished": "2024-11-15T12:20:44-04:00", "title": "2-respuesta-sobre-el-expediente-13204-equipos-medicos-673766cc1aa9d.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/6ec9e517-1d14-4301-8c43-bf367dd120bc/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0cf-ab1a-68b0-9ce9-71fcb6f98d7b", "datePublished": "2024-11-07T10:34:14-04:00", "title": "chat-equipos-672cc1d632db5.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/1f3dffb3-db5b-422c-9d0a-87c09c566fae/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3655-beb2-6b20-804f-995574a2dd7e", "datePublished": "2024-11-15T12:22:00-04:00", "title": "10-cco-lpn-21-2024-comp2-6737671802e1f.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/ff767cbf-1b66-49e8-a80d-1e30af3f87b5/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3655-f223-6572-b395-35394d4cf29a", "datePublished": "2024-11-15T12:22:05-04:00", "title": "11-cpa-lpn-21-2024-comp2-6737671d63814.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/f43ada9e-242e-4386-8c41-7273777c1616/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3653-e8bf-62d0-bcc2-c9245f3a41a7", "datePublished": "2024-11-15T12:21:10-04:00", "title": "5-infor-eva-comp-02-lpn-21-24-673766e672693.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/a028c0ab-d6a8-4c45-937f-ed66e0820257/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3654-d6f6-6156-9fb3-dbfc08c45f38", "datePublished": "2024-11-15T12:21:35-04:00", "title": "7-anexo-b-02-05-solumedicfirmado-673766ffb4dbf.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/7ef29b02-e006-4e01-ab04-805b259db10f/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9841c-1ee4-6350-84af-35ae32921e76", "datePublished": "2024-11-01T08:09:26-04:00", "title": "resol-d-n-182-adm-de-contratos-001-6724b6e676989.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/6d097f03-ccc2-4e91-af29-f38055328142/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa3655-7c88-6006-94c5-efabaa7d21b0", "datePublished": "2024-11-15T12:21:53-04:00", "title": "9-anexo-b-02-17-solumedicfirmado-67376710d0ca1.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/100737de-8a2f-4365-b0dc-ccb4b78f60f4/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3654-78e2-67ea-a737-918d4c89ef91", "datePublished": "2024-11-15T12:21:25-04:00", "title": "6-anexo-b-02-05-argonfirmado-673766f5d2c55.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/2a91d331-f8f4-45fd-b9db-f50b124cdd28/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3653-1f93-6780-8e1c-013aee2c4863", "datePublished": "2024-11-15T12:20:49-04:00", "title": "3-notificacion-de-adjudicacion-complementaria-n-2-673766d19db5b.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/9dce146c-66a5-4e09-b97f-9bf1dc89029e/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0cf-7122-6144-98e1-d16328a1339a", "datePublished": "2024-11-07T10:34:08-04:00", "title": "expediente-de-mesa-de-entrada-dncp-n-13204-rv-nota-una-fcm-daf-dcp-n-2342-2024-672cc1d01eab9.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/672ed596-9110-4365-96fe-6ae21725bcea/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0d0-20fb-6e26-a412-2b79f7fa89e7", "datePublished": "2024-11-07T10:34:26-04:00", "title": "nota-dncp-lpn-21-2024-comp2-exp-672cc1e22807a.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/5528203e-0da4-416a-a4bc-07b887a0d34e/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9841b-cc33-6656-8b4e-079d7616b65d", "datePublished": "2024-11-01T08:09:17-04:00", "title": "cdp-lpn-n-21-2024-6724b6ddc809f.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/00f25513-2e84-42e3-961c-d5ad6af14c9e/download", "language": "es", "documentTypeDetails": "CDP"}, {"id": "1ef9d0cf-3d97-61bc-940c-5d2885f42e88", "datePublished": "2024-11-07T10:34:02-04:00", "title": "nota-n-2428-2024-reparo-dysa-healthcare-s-a-lpn-21-2024firmado-672cc1cab1f3b.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc05-8114-6cda-9693-99740a454274/files/57ec73d0-869a-4b11-8580-08b1a0745773/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}]}, {"id": "LP-28001-24-246508", "implementation": {"financialProgress": {"breakdown": [{"id": "2024/28/1/1/1/0/4/4/11/535/20/LP-28001-24-246508", "period": {"startDate": "2024-01-01T00:00:00Z", "endDate": "2024-12-31T00:00:00Z"}, "measures": {"monto_a_utilizar": 9600000000}, "classifications": {"anio": "2024", "nivel": "28", "entidad": "1", "tipo_programa": "1", "programa": "1", "sub_programa": "0", "proyecto": "4", "financiador": "4", "departamento": "11", "objeto_gasto": "535", "fuente_financiamiento": "20", "cdp": "1307"}, "financialCode": "LP-28001-24-246508"}]}, "transactions": [{"id": "SICP+LP-28001-24-246508+0010010004002+4387998", "sourceSystem": "SICP", "value": {"currency": "PYG", "amount": 91586331}, "date": "2025-01-30T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "CATETERES Y AFINES S.A.", "id": "PY-RUC-80030030-0"}, "requestDate": "2025-01-30T00:00:00-04:00", "finantialObligations": [{"id": "0010010004002", "bill": {"id": "0010010004002", "type": "FACTURA", "date": "2025-01-13T00:00:00-04:00", "amount": {"amount": 98268596, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 2680053, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 3573403, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 343047, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 2680053, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246508"}]}, "awardID": "1ef8f9ac-dd29-6e46-8b90-1930e52a79ef", "status": "active", "statusDetails": "publicado", "period": {"startDate": "2024-11-11T00:00:00-04:00"}, "value": {"amount": 98268596, "currency": "PYG"}, "documents": [{"id": "1efa364f-b9dd-634e-bcd3-a3333a7e8560", "datePublished": "2024-11-15T12:19:18-04:00", "title": "6-anexo-b-02-05-argonfirmado-673766766e09a.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8f9ac-dd29-6e46-8b90-1930e52a79ef/files/705f82a5-c4a7-479f-9d24-9ebf376cc2db/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa364e-8219-6404-8b21-698ea7a23b8d", "datePublished": "2024-11-15T12:18:45-04:00", "title": "1-nota-n-2502-2024-reparo-lpn-21-2024firmado-67376655bb162.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8f9ac-dd29-6e46-8b90-1930e52a79ef/files/cc48465f-9dc3-48c5-b77b-dee3b20c08a4/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa364f-e584-62ea-ab82-8db1c76b315b", "datePublished": "2024-11-15T12:19:23-04:00", "title": "7-anexo-b-02-05-solumedicfirmado-6737667b039c3.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8f9ac-dd29-6e46-8b90-1930e52a79ef/files/1d35bfc2-a785-4d81-a7e8-97b1660541d3/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa0413-fdbc-65c4-aace-df7672c2348b", "datePublished": "2024-11-11T12:25:57-04:00", "title": "contrato-form-n-175-2024-cateteres-y-afines-s-a-lpn-n-21-2024-673222057fc1c.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8f9ac-dd29-6e46-8b90-1930e52a79ef/files/40de492a-2c7f-4484-a1b9-ae30f76e0a99/download", "language": "es", "documentType": "contractSigned", "documentTypeDetails": "Contrato"}, {"id": "1efa3650-c985-632c-bd51-331b1a0580b4", "datePublished": "2024-11-15T12:19:47-04:00", "title": "11-cpa-lpn-21-2024-comp2-67376692e152d.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8f9ac-dd29-6e46-8b90-1930e52a79ef/files/2c3755a5-bc9c-4f6a-b19f-e9318f0496f4/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3650-5fc4-6cee-a139-5f9ed276b6a7", "datePublished": "2024-11-15T12:19:35-04:00", "title": "9-anexo-b-02-17-solumedicfirmado-673766877aa58.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8f9ac-dd29-6e46-8b90-1930e52a79ef/files/df9124cf-7370-4637-9f98-f23b8bd4cb46/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa364e-ada2-6210-8a75-636a68978a3e", "datePublished": "2024-11-15T12:18:50-04:00", "title": "2-respuesta-sobre-el-expediente-13204-equipos-medicos-6737665a538c1.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8f9ac-dd29-6e46-8b90-1930e52a79ef/files/f13178d6-6dd1-41cb-940e-23caee034214/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa0414-be40-64bc-b387-85dcc6da1ab0", "datePublished": "2024-11-11T12:26:17-04:00", "title": "resol-d-n-182-adm-de-contratos-001-67322219b66ed.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8f9ac-dd29-6e46-8b90-1930e52a79ef/files/29785b60-b4df-4e05-95d6-c30de2969710/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa3650-1d28-6f98-b3dd-97b90f155d41", "datePublished": "2024-11-15T12:19:28-04:00", "title": "8-anexo-b-02-17-argonfirmado-67376680d2ec8.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8f9ac-dd29-6e46-8b90-1930e52a79ef/files/e7d64d0b-b06f-4082-9a3b-87e258a501f4/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa364f-1acb-61b6-9dca-1ff30fb76acc", "datePublished": "2024-11-15T12:19:01-04:00", "title": "4-resol-d-n-1873-2024-eval-compl-n-02-lpn-n-21-024-67376665b5ed7.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8f9ac-dd29-6e46-8b90-1930e52a79ef/files/b6341414-9317-4c5e-8277-4f59b07a3eb4/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa364f-7700-635a-b034-4fafb3b9e575", "datePublished": "2024-11-15T12:19:11-04:00", "title": "5-infor-eva-comp-02-lpn-21-24-6737666f239b1.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8f9ac-dd29-6e46-8b90-1930e52a79ef/files/17ace352-d2d4-4247-b7f1-dcd8e0313102/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa364e-e2c5-6712-8576-153f1b57a891", "datePublished": "2024-11-15T12:18:55-04:00", "title": "3-notificacion-de-adjudicacion-complementaria-n-2-6737665fe0a93.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8f9ac-dd29-6e46-8b90-1930e52a79ef/files/a0538db6-d897-4e77-a582-166ca31c55e2/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa0414-673a-6d8e-948b-ffa99e668877", "datePublished": "2024-11-11T12:26:08-04:00", "title": "cdp-lpn-n-21-2024-6732221097161.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8f9ac-dd29-6e46-8b90-1930e52a79ef/files/55464af6-5ebc-4e22-adc8-5b5ff457fbcc/download", "language": "es", "documentTypeDetails": "CDP"}, {"id": "1efa0415-17c5-6c6c-b2c8-9de8d769e7a6", "datePublished": "2024-11-11T12:26:27-04:00", "title": "notificacion-de-adjudicacion-complementaria-n-1-6732222325df4.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8f9ac-dd29-6e46-8b90-1930e52a79ef/files/5f740332-9157-4ae0-a90f-567538ee718b/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa3650-988d-6bb6-8141-d52e60ce3527", "datePublished": "2024-11-15T12:19:41-04:00", "title": "10-cco-lpn-21-2024-comp2-6737668dbef2a.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8f9ac-dd29-6e46-8b90-1930e52a79ef/files/f84fba1a-69b5-4328-be8c-debda42783b8/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}]}, {"id": "LP-28001-24-246515", "implementation": {"financialProgress": {"breakdown": [{"id": "2024/28/1/1/1/0/4/4/11/535/20/LP-28001-24-246515", "period": {"startDate": "2024-01-01T00:00:00Z", "endDate": "2024-12-31T00:00:00Z"}, "measures": {"monto_a_utilizar": 9600000000}, "classifications": {"anio": "2024", "nivel": "28", "entidad": "1", "tipo_programa": "1", "programa": "1", "sub_programa": "0", "proyecto": "4", "financiador": "4", "departamento": "11", "objeto_gasto": "535", "fuente_financiamiento": "20", "cdp": "1307"}, "financialCode": "LP-28001-24-246515"}]}, "transactions": [{"id": "SICP+LP-28001-24-246515+0010010000133+4387996", "sourceSystem": "SICP", "value": {"currency": "PYG", "amount": 282639290}, "date": "2025-01-30T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "SOLUMEDIC S.A.", "id": "PY-RUC-80023913-0"}, "requestDate": "2025-01-30T00:00:00-04:00", "finantialObligations": [{"id": "0010010000133", "bill": {"id": "0010010000133", "type": "FACTURA", "date": "2025-01-20T00:00:00-04:00", "amount": {"amount": 305920000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 8343273, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 11124364, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 2478150, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 1067939, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 8343273, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246515"}, {"id": "SIAF+LP-28001-24-246515+001-001-0000068+4348288", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 71279360}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "SOLUMEDIC S.A.", "id": "PY-RUC-80023913-0"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0000068", "bill": {"id": "001-001-0000068", "type": "FACTURA", "date": "2024-11-13T00:00:00-04:00", "amount": {"amount": 76480000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 2781091, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 266985, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 2085818, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246515"}]}, "awardID": "1ef8bc90-a11a-663e-b2d6-79cf5a5a412f", "status": "active", "statusDetails": "publicado", "period": {"startDate": "2024-11-08T00:00:00-04:00"}, "value": {"amount": 382400000, "currency": "PYG"}, "documents": [{"id": "1efa3664-b1a9-6690-9008-8101edf14684", "datePublished": "2024-11-15T12:28:41-04:00", "title": "11-cpa-lpn-21-2024-comp2-673768a94bd38.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc90-a11a-663e-b2d6-79cf5a5a412f/files/bfedf367-cabf-4480-9588-ff794ed1435c/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3664-18aa-6890-be09-0754de46b0fc", "datePublished": "2024-11-15T12:28:25-04:00", "title": "8-anexo-b-02-17-argonfirmado-673768993fdbe.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc90-a11a-663e-b2d6-79cf5a5a412f/files/f594f9b4-33e8-4c17-8a27-2e07187a31b2/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3664-81a9-6e86-bd1c-3d7264d259fe", "datePublished": "2024-11-15T12:28:36-04:00", "title": "10-cco-lpn-21-2024-comp2-673768a448bed.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc90-a11a-663e-b2d6-79cf5a5a412f/files/e33a47bc-7964-426f-b914-b0d4adaaf603/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3663-62d9-6b56-88fd-9782e0125e34", "datePublished": "2024-11-15T12:28:06-04:00", "title": "5-infor-eva-comp-02-lpn-21-24-67376885e29e8.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc90-a11a-663e-b2d6-79cf5a5a412f/files/36b9d2b0-5f38-437b-b920-d46b710adbb8/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3663-11ff-6ab4-b0bc-5f585531e105", "datePublished": "2024-11-15T12:27:57-04:00", "title": "4-resol-d-n-1873-2024-eval-compl-n-02-lpn-n-21-024-6737687da7c9a.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc90-a11a-663e-b2d6-79cf5a5a412f/files/74e6a19a-6e2c-4a31-bb16-37eb2ab7baf9/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9de5e-69f1-6fae-bcab-db687d51974d", "datePublished": "2024-11-08T12:27:01-04:00", "title": "cdp-lpn-n-21-2024-672e2dc5568be.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc90-a11a-663e-b2d6-79cf5a5a412f/files/7e95b4af-c606-42fc-9812-5ef511f3d8cc/download", "language": "es", "documentTypeDetails": "CDP"}, {"id": "1ef9de60-d172-6afa-901e-e515247e8205", "datePublished": "2024-11-08T12:28:05-04:00", "title": "chat-equipos-672e2e05d83ef.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc90-a11a-663e-b2d6-79cf5a5a412f/files/947277c6-bea6-4be2-9433-c675bc9bbadb/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1ef9de5e-1337-6952-8281-bff0192015f2", "datePublished": "2024-11-08T12:26:52-04:00", "title": "contrato-form-n-171-solumedic-s-a-lpn-n-21-2024-672e2dbc38759.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc90-a11a-663e-b2d6-79cf5a5a412f/files/61d8f579-ced5-4230-98e5-5d164302a34b/download", "language": "es", "documentType": "contractSigned", "documentTypeDetails": "Contrato"}, {"id": "1efa3664-4c82-6b2c-b901-b5be7ad7686a", "datePublished": "2024-11-15T12:28:30-04:00", "title": "9-anexo-b-02-17-solumedicfirmado-6737689eaf510.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc90-a11a-663e-b2d6-79cf5a5a412f/files/6cc9769a-cfd4-456f-b1e3-4819c492c6d4/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3662-7211-693a-8ca4-158115e383c6", "datePublished": "2024-11-15T12:27:41-04:00", "title": "1-nota-n-2502-2024-reparo-lpn-21-2024firmado-6737686ce8f82.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc90-a11a-663e-b2d6-79cf5a5a412f/files/79a2f882-f8dc-4478-8c2b-0c9da2a8827a/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3662-a74b-6e48-b32c-8f64279abe52", "datePublished": "2024-11-15T12:27:46-04:00", "title": "2-respuesta-sobre-el-expediente-13204-equipos-medicos-673768727e889.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc90-a11a-663e-b2d6-79cf5a5a412f/files/a6973668-dc9a-4b68-b904-56c3a9909757/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9de5f-8b7d-61a4-8daa-b9dc33d80afb", "datePublished": "2024-11-08T12:27:31-04:00", "title": "nota-dncp-lpn-21-2024-comp2-exp-672e2de345c05.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc90-a11a-663e-b2d6-79cf5a5a412f/files/b82c4cbc-2524-471d-bc3d-403abb621255/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1ef9de5e-f0fe-6d4e-8d84-91bcde6ed8ff", "datePublished": "2024-11-08T12:27:15-04:00", "title": "resol-d-n-182-adm-de-contratos-001-672e2dd37a665.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc90-a11a-663e-b2d6-79cf5a5a412f/files/49af118c-113a-4be7-b222-decee7c8468f/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa3663-9ec8-6130-accb-f7efc8f20e14", "datePublished": "2024-11-15T12:28:12-04:00", "title": "6-anexo-b-02-05-argonfirmado-6737688c78011.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc90-a11a-663e-b2d6-79cf5a5a412f/files/403fb8aa-8018-43a8-bbb5-44eedf132df4/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3662-dda2-6816-8ad0-b33a7b2a7671", "datePublished": "2024-11-15T12:27:52-04:00", "title": "3-notificacion-de-adjudicacion-complementaria-n-2-6737687836498.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc90-a11a-663e-b2d6-79cf5a5a412f/files/1bf02da1-49cb-4833-a6b5-a12c15fd51c0/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9de5f-e030-6bec-a4b2-97574538d3fb", "datePublished": "2024-11-08T12:27:40-04:00", "title": "expediente-de-mesa-de-entrada-dncp-n-13204-rv-nota-una-fcm-daf-dcp-n-2342-2024-672e2dec8def9.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc90-a11a-663e-b2d6-79cf5a5a412f/files/1aa8d83c-afdb-41fb-a2d8-ead155c9e168/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa3663-e21d-643a-a125-81217b695e70", "datePublished": "2024-11-15T12:28:19-04:00", "title": "7-anexo-b-02-05-solumedicfirmado-6737689385b0b.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc90-a11a-663e-b2d6-79cf5a5a412f/files/7db214bb-c0f9-43fd-aad7-8b4c9813fda4/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}]}, {"id": "LP-28001-24-246516", "implementation": {"financialProgress": {"breakdown": [{"id": "2024/28/1/1/1/0/4/4/11/535/20/LP-28001-24-246516", "period": {"startDate": "2024-01-01T00:00:00Z", "endDate": "2024-12-31T00:00:00Z"}, "measures": {"monto_a_utilizar": 9600000000}, "classifications": {"anio": "2024", "nivel": "28", "entidad": "1", "tipo_programa": "1", "programa": "1", "sub_programa": "0", "proyecto": "4", "financiador": "4", "departamento": "11", "objeto_gasto": "535", "fuente_financiamiento": "20", "cdp": "1307"}, "financialCode": "LP-28001-24-246516"}]}, "transactions": [{"id": "SICP+LP-28001-24-246516+0010020000108+4387997", "sourceSystem": "SICP", "value": {"currency": "PYG", "amount": 160770000}, "date": "2025-01-30T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "ARGON S.R.L.", "id": "PY-RUC-80004373-1"}, "requestDate": "2025-01-30T00:00:00-04:00", "finantialObligations": [{"id": "0010020000108", "bill": {"id": "0010020000108", "type": "FACTURA", "date": "2024-12-06T00:00:00-04:00", "amount": {"amount": 172500000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 4704545, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 6272727, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 602182, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 4704545, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246516"}]}, "awardID": "1ef8bbd9-8739-6b0a-9b77-1717c52fda49", "status": "active", "statusDetails": "publicado", "period": {"startDate": "2024-11-18T00:00:00-04:00"}, "value": {"amount": 172500000, "currency": "PYG"}, "documents": [{"id": "1efa5c3d-b75a-6d2e-9baf-a5f72d917c6e", "datePublished": "2024-11-18T12:43:29-04:00", "title": "5-infor-eva-comp-02-lpn-21-24-673b609fee16e.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbd9-8739-6b0a-9b77-1717c52fda49/files/a8ca40aa-df5c-4027-8a61-1ca9822032ec/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa5c3d-fd49-69f2-98ee-af1a8f097bec", "datePublished": "2024-11-18T12:43:36-04:00", "title": "6-anexo-b-02-05-argonfirmado-673b60a853731.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbd9-8739-6b0a-9b77-1717c52fda49/files/73a4f9a7-451a-4b78-ae51-43163e3e0a4c/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa5c3e-50a7-6ec8-aa00-7d3f3d0a2bfc", "datePublished": "2024-11-18T12:43:45-04:00", "title": "7-anexo-b-02-05-solumedicfirmado-673b60b11453c.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbd9-8739-6b0a-9b77-1717c52fda49/files/33e65379-5ad0-4d28-b2d1-2e1f0f6e4de4/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa5c40-24d8-6106-b42e-e10e8c695a3a", "datePublished": "2024-11-18T12:44:34-04:00", "title": "12-cdp-lpn-n-21-2024-673b60e22a8bf.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbd9-8739-6b0a-9b77-1717c52fda49/files/7e317b42-4874-452d-9122-d5bef2808a19/download", "language": "es", "documentTypeDetails": "CDP"}, {"id": "1efa5c3c-233c-64b8-bdce-ed51773d62a3", "datePublished": "2024-11-18T12:42:46-04:00", "title": "1-nota-n-2515-2024-comunicacion-de-contrato-argon-srlfirmado-673b60769e237.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbd9-8739-6b0a-9b77-1717c52fda49/files/d241e106-7684-4ef4-9441-8879aaf65823/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa5c3f-2fe9-63a2-af67-0d8b66000509", "datePublished": "2024-11-18T12:44:08-04:00", "title": "10-cco-lpn-21-2024-comp2-673b60c877fe8.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbd9-8739-6b0a-9b77-1717c52fda49/files/f735a5cc-764a-465a-94b3-fc94e0bce0ac/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa5c3c-9739-6b90-a178-ad08f13f1656", "datePublished": "2024-11-18T12:42:58-04:00", "title": "2-contrato-form-n-165-2024-argon-srl-lpn-21-24-673b6082c171f.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbd9-8739-6b0a-9b77-1717c52fda49/files/de835e28-f4d4-4565-a04d-5b4ecc28716f/download", "language": "es", "documentType": "contractSigned", "documentTypeDetails": "Contrato"}, {"id": "1efa5c3d-0d31-6c58-998f-5b38670f4dde", "datePublished": "2024-11-18T12:43:11-04:00", "title": "3-notificacion-de-adjudicacion-complementaria-n-2-673b608f25e59.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbd9-8739-6b0a-9b77-1717c52fda49/files/a1e44a7b-86fb-4d12-821e-adee2085f571/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa5c3e-8b19-6bec-b388-c7da11a89a4d", "datePublished": "2024-11-18T12:43:51-04:00", "title": "8-anexo-b-02-17-argonfirmado-673b60b731fca.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbd9-8739-6b0a-9b77-1717c52fda49/files/df103bc2-df05-483e-b15a-ee3d9b973819/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa5c3f-cffd-69ba-b27b-61b090d1c684", "datePublished": "2024-11-18T12:44:25-04:00", "title": "13-resol-d-n-182-adm-de-contratos-001-673b60d93e925.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbd9-8739-6b0a-9b77-1717c52fda49/files/be08a94b-cf84-424b-8611-9a2862dc23cd/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa5c3d-49d7-622a-a3de-07753fd4ea91", "datePublished": "2024-11-18T12:43:17-04:00", "title": "4-resol-d-n-1873-2024-eval-compl-n-02-lpn-n-21-024-673b60957639d.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbd9-8739-6b0a-9b77-1717c52fda49/files/f429d395-e364-46db-86d3-a7100c2ff3cf/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa5c3e-c7bc-600e-9bed-7d717204ad72", "datePublished": "2024-11-18T12:43:57-04:00", "title": "9-anexo-b-02-17-solumedicfirmado-673b60bd8bb6c.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbd9-8739-6b0a-9b77-1717c52fda49/files/02062d6c-9d17-431a-b1ca-1144a1d4843b/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa5c3f-653a-6bdc-9498-c95c818086c6", "datePublished": "2024-11-18T12:44:14-04:00", "title": "11-cpa-lpn-21-2024-comp2-673b60ce15ece.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbd9-8739-6b0a-9b77-1717c52fda49/files/b3897281-1fbd-40e3-8200-3bd37168ea52/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}]}, {"id": "LP-28001-24-246513", "implementation": {"financialProgress": {"breakdown": [{"id": "2024/28/1/1/1/0/4/4/11/535/20/LP-28001-24-246513", "period": {"startDate": "2024-01-01T00:00:00Z", "endDate": "2024-12-31T00:00:00Z"}, "measures": {"monto_a_utilizar": 9600000000}, "classifications": {"anio": "2024", "nivel": "28", "entidad": "1", "tipo_programa": "1", "programa": "1", "sub_programa": "0", "proyecto": "4", "financiador": "4", "departamento": "11", "objeto_gasto": "535", "fuente_financiamiento": "20", "cdp": "1307"}, "financialCode": "LP-28001-24-246513"}]}, "transactions": [{"id": "SIAF+LP-28001-24-246513+001-001-0000249+4363585", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 527884800}, "date": "2025-01-08T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "IMESE S.A.", "id": "PY-RUC-80016426-1"}, "requestDate": "2024-12-27T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0000249", "bill": {"id": "001-001-0000249", "type": "FACTURA", "date": "2024-12-10T00:00:00-04:00", "amount": {"amount": 566400000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 20596364, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 1977251, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 15447273, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246513"}, {"id": "SIAF+LP-28001-24-246513+001-001-0000204+4347786", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 41008000}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "IMESE S.A.", "id": "PY-RUC-80016426-1"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0000204", "bill": {"id": "001-001-0000204", "type": "FACTURA", "date": "2024-11-07T00:00:00-04:00", "amount": {"amount": 44000000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 1600000, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 153600, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 1200000, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246513"}, {"id": "SIAF+LP-28001-24-246513+001-001-0000202+4347784", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 131971200}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "IMESE S.A.", "id": "PY-RUC-80016426-1"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0000202", "bill": {"id": "001-001-0000202", "type": "FACTURA", "date": "2024-11-07T00:00:00-04:00", "amount": {"amount": 141600000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 5149091, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 494313, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 3861818, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246513"}, {"id": "SIAF+LP-28001-24-246513+001-001-0000203+4347785", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 41008000}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "IMESE S.A.", "id": "PY-RUC-80016426-1"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0000203", "bill": {"id": "001-001-0000203", "type": "FACTURA", "date": "2024-11-07T00:00:00-04:00", "amount": {"amount": 44000000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 1600000, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 153600, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 1200000, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246513"}]}, "awardID": "1ef8bc48-e024-6dae-8bb2-09ffc38db45b", "status": "active", "statusDetails": "publicado", "period": {"startDate": "2024-10-30T00:00:00-04:00"}, "value": {"amount": 796000000, "currency": "PYG"}, "documents": [{"id": "1ef96acc-a38c-6fda-a062-39abb3928f7a", "datePublished": "2024-10-30T07:50:34-04:00", "title": "contrato-form-n-168-2024-imese-s-a-lpn-n-21-2024-67220f7a38e3a.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/86a1238b-2d20-427b-befb-a929bc2409b8/download", "language": "es", "documentType": "contractSigned", "documentTypeDetails": "Contrato"}, {"id": "1efa3659-2caf-6a8a-a28a-b171df71a641", "datePublished": "2024-11-15T12:23:32-04:00", "title": "10-cco-lpn-21-2024-comp2-673767740d6f1.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/5d04ffc3-ac54-4202-ae32-28a0719c1b21/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0d2-675f-67ee-969a-63e224e9e55d", "datePublished": "2024-11-07T10:35:27-04:00", "title": "chat-equipos-672cc21f982c4.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/e85af7e6-c0ae-46f7-aebb-abd4e04f2995/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3658-fd41-649c-aeab-0f509f388c1c", "datePublished": "2024-11-15T12:23:27-04:00", "title": "9-anexo-b-02-17-solumedicfirmado-6737676f17cea.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/29b69989-1173-40dd-a161-90cd5820615a/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3657-45a9-651a-84e1-350d47b49ef8", "datePublished": "2024-11-15T12:22:41-04:00", "title": "1-nota-n-2502-2024-reparo-lpn-21-2024firmado-6737674101fec.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/59a0f724-bd70-4888-9149-2dc65947c77c/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3657-a73f-614e-b98b-cf8064ff0958", "datePublished": "2024-11-15T12:22:51-04:00", "title": "3-notificacion-de-adjudicacion-complementaria-n-2-6737674b3b333.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/7bcf4c7f-5e8a-4586-8761-5a5b53dfbad6/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3659-5ad5-607c-b964-f3751299247f", "datePublished": "2024-11-15T12:23:36-04:00", "title": "11-cpa-lpn-21-2024-comp2-67376778e1521.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/88ae8f87-d0a5-4254-a791-160c07fe6f18/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0d2-2101-67fc-aa40-3101e12adcd9", "datePublished": "2024-11-07T10:35:20-04:00", "title": "expediente-de-mesa-de-entrada-dncp-n-13204-rv-nota-una-fcm-daf-dcp-n-2342-2024-672cc21840856.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/db85c963-80bf-40a1-85c1-204fde9bce96/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3658-97cd-6d86-86bb-51fd2fadfb89", "datePublished": "2024-11-15T12:23:16-04:00", "title": "7-anexo-b-02-05-solumedicfirmado-6737676473c7d.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/fae0679c-93f6-4e0e-8e9e-5e1eaa0b9c7e/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef96acd-0e1f-6244-a2eb-9b430867ccf6", "datePublished": "2024-10-30T07:50:45-04:00", "title": "cdp-lpn-n-21-2024-67220f855afa1.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/c99cc6a5-055f-4323-9c49-7d6331a0944a/download", "language": "es", "documentTypeDetails": "CDP"}, {"id": "1efa3658-6969-6594-8203-e53c904ad19d", "datePublished": "2024-11-15T12:23:11-04:00", "title": "6-anexo-b-02-05-argonfirmado-6737675f94143.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/a860ea07-a3de-4bff-b8e4-3406411c77c4/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3657-760f-647a-b1e3-490dc056db78", "datePublished": "2024-11-15T12:22:46-04:00", "title": "2-respuesta-sobre-el-expediente-13204-equipos-medicos-673767461677e.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/97c60f06-2e0d-4c26-ab2a-7554263d87a6/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3658-3157-6566-b98a-d7481c010a81", "datePublished": "2024-11-15T12:23:05-04:00", "title": "5-infor-eva-comp-02-lpn-21-24-673767595e2c8.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/b1a6c4db-202b-4e8d-ae1e-05eda7016094/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0d2-d957-64fa-8ee7-13a73c03c7e9", "datePublished": "2024-11-07T10:35:39-04:00", "title": "nota-dncp-lpn-21-2024-comp2-exp-672cc22b23e12.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/b1a8fb8e-5dea-4c54-8b25-cb82724b0e23/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3657-d9b7-6e14-bca3-bbc151daffe5", "datePublished": "2024-11-15T12:22:56-04:00", "title": "4-resol-d-n-1873-2024-eval-compl-n-02-lpn-n-21-024-6737675078b1e.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/8374d16c-264d-41c9-b719-6782266f1273/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef96acd-ce82-686a-8369-33fc3329d7ac", "datePublished": "2024-10-30T07:51:05-04:00", "title": "notificacion-adjudicacion-lpn-n-21-2024-67220f998f2dc.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/e3e6224e-240f-4ac8-9b16-5a4f9b32b29a/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1ef9d0d1-ea29-6ed2-a044-99a440d53ab9", "datePublished": "2024-11-07T10:35:14-04:00", "title": "nota-n-2427-2024-reparo-lpn-21-2024firmado-672cc2127773c.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/23ebc180-7406-444b-9061-c1983ef9811b/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef96acd-ffdd-6662-8450-9de63f0aa88b", "datePublished": "2024-10-30T07:51:10-04:00", "title": "resol-d-n-182-adm-de-contratos-001-67220f9ebbcbe.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/813e3fd3-036f-4589-bf27-b808f35faa8a/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa3658-cc2f-617e-b4db-977bb7c387cb", "datePublished": "2024-11-15T12:23:22-04:00", "title": "8-anexo-b-02-17-argonfirmado-67376769ec6e0.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc48-e024-6dae-8bb2-09ffc38db45b/files/39073be7-8328-440a-9db2-6ab79946f9aa/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}]}, {"id": "AC-28001-24-248637", "implementation": {"financialProgress": {"breakdown": [{"id": "2024/28/1/1/1/0/4/4/11/535/20/AC-28001-24-248637", "period": {"startDate": "2024-01-01T00:00:00Z", "endDate": "2024-12-31T00:00:00Z"}, "measures": {"monto_a_utilizar": 326791000}, "classifications": {"anio": "2024", "nivel": "28", "entidad": "1", "tipo_programa": "1", "programa": "1", "sub_programa": "0", "proyecto": "4", "financiador": "4", "departamento": "11", "objeto_gasto": "535", "fuente_financiamiento": "20", "cdp": "1307"}, "financialCode": "AC-28001-24-248637"}]}}}, {"id": "LP-28001-24-244776", "implementation": {"financialProgress": {"breakdown": [{"id": "2024/28/1/1/1/0/4/4/11/535/20/LP-28001-24-244776", "period": {"startDate": "2024-01-01T00:00:00Z", "endDate": "2024-12-31T00:00:00Z"}, "measures": {"monto_a_utilizar": 9600000000}, "classifications": {"anio": "2024", "nivel": "28", "entidad": "1", "tipo_programa": "1", "programa": "1", "sub_programa": "0", "proyecto": "4", "financiador": "4", "departamento": "11", "objeto_gasto": "535", "fuente_financiamiento": "20", "cdp": "1307"}, "financialCode": "LP-28001-24-244776"}]}, "transactions": [{"id": "SIAF+LP-28001-24-244776+001-002-0000231+4347261", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 36348001}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "ANDRES H. ARCE SA", "id": "PY-RUC-80023488-0"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-002-0000231", "bill": {"id": "001-002-0000231", "type": "FACTURA", "date": "2024-11-11T00:00:00-04:00", "amount": {"amount": 39000000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 1418182, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 136145, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 1063636, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-244776"}]}, "awardID": "1ef8bbc8-387e-65ee-8df7-b79c7f8ce3dd", "status": "active", "statusDetails": "publicado", "period": {"startDate": "2024-10-29T00:00:00-04:00"}, "value": {"amount": 39000000, "currency": "PYG"}, "documents": [{"id": "1ef95ee3-1a6f-6a8a-8735-4d8696bd2c7e", "datePublished": "2024-10-29T09:06:13-04:00", "title": "contrato-form-n-164-2024-andres-h-arce-sa-lpn-n-21-2024-6720cfb5d5951.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbc8-387e-65ee-8df7-b79c7f8ce3dd/files/1e0ce9f5-af9f-4b1a-a230-c50800762d5a/download", "language": "es", "documentType": "contractSigned", "documentTypeDetails": "Contrato"}, {"id": "1ef95ee4-fdf7-6fe0-8167-eb96d72a6f49", "datePublished": "2024-10-29T09:07:04-04:00", "title": "resol-d-n-182-adm-de-contratos-001-6720cfe8893e7.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbc8-387e-65ee-8df7-b79c7f8ce3dd/files/8b3ce22c-5e7d-4369-b691-ca95fcafe785/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1ef95ee3-9c92-6d1e-9db5-fd49edb6e51d", "datePublished": "2024-10-29T09:06:27-04:00", "title": "cdp-lpn-n-21-2024-6720cfc38371c.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbc8-387e-65ee-8df7-b79c7f8ce3dd/files/7720158e-a04c-4e3c-85b5-86add8b1138f/download", "language": "es", "documentTypeDetails": "CDP"}, {"id": "1ef95ee4-8490-6cce-b95c-9bc18922692a", "datePublished": "2024-10-29T09:06:51-04:00", "title": "notificacion-adjudicacion-lpn-n-21-2024-6720cfdbce7c9.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbc8-387e-65ee-8df7-b79c7f8ce3dd/files/d4d472a9-1372-4119-b7a9-191bf8c415b7/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}]}, {"id": "LP-28001-24-246512", "implementation": {"financialProgress": {"breakdown": [{"id": "2024/28/1/1/1/0/4/4/11/535/20/LP-28001-24-246512", "period": {"startDate": "2024-01-01T00:00:00Z", "endDate": "2024-12-31T00:00:00Z"}, "measures": {"monto_a_utilizar": 9600000000}, "classifications": {"anio": "2024", "nivel": "28", "entidad": "1", "tipo_programa": "1", "programa": "1", "sub_programa": "0", "proyecto": "4", "financiador": "4", "departamento": "11", "objeto_gasto": "535", "fuente_financiamiento": "20", "cdp": "1307"}, "financialCode": "LP-28001-24-246512"}]}, "transactions": [{"id": "SIAF+LP-28001-24-246512+001-001-0011620+4347325", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 17931680}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "BIOERIX S.A. ", "id": "PY-RUC-80051821-7"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0011620", "bill": {"id": "001-001-0011620", "type": "FACTURA", "date": "2024-11-07T00:00:00-04:00", "amount": {"amount": 19240000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 699636, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 67165, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 524727, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246512"}, {"id": "SICP+LP-28001-24-246512+0010010011659+4388000", "sourceSystem": "SICP", "value": {"currency": "PYG", "amount": 71726720}, "date": "2025-01-30T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "BIOERIX S.A. ", "id": "PY-RUC-80051821-7"}, "requestDate": "2025-01-30T00:00:00-04:00", "finantialObligations": [{"id": "0010010011659", "bill": {"id": "0010010011659", "type": "FACTURA", "date": "2024-12-09T00:00:00-04:00", "amount": {"amount": 76960000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 2098909, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 2798545, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 268660, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 2098909, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246512"}]}, "awardID": "1ef8bbdd-ce68-682e-9cb6-832f507ce7a1", "status": "active", "statusDetails": "publicado", "period": {"startDate": "2024-11-06T00:00:00-04:00"}, "value": {"amount": 96200000, "currency": "PYG"}, "documents": [{"id": "1ef9c30b-32a0-6f32-8409-591f73beb026", "datePublished": "2024-11-06T08:17:25-04:00", "title": "cdp-lpn-n-21-2024-672b5044de4db.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/f129c713-c8c6-4b1e-882e-97447915210d/download", "language": "es", "documentTypeDetails": "CDP"}, {"id": "1efa364b-62c1-6712-9e9f-5b0e665f2168", "datePublished": "2024-11-15T12:17:22-04:00", "title": "4-resol-d-n-1873-2024-eval-compl-n-02-lpn-n-21-024-673766014a887.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/9c473594-8f84-4a80-889a-f74af7a82004/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9c30c-23c0-6c3c-85b1-f3a6dd605657", "datePublished": "2024-11-06T08:17:50-04:00", "title": "resol-d-n-182-adm-de-contratos-001-672b505e350f3.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/10f6ae15-fa62-4427-86d1-f74172a047d4/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa364c-9fb6-6108-be84-bf99b391499e", "datePublished": "2024-11-15T12:17:55-04:00", "title": "9-anexo-b-02-17-solumedicfirmado-6737662326ac9.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/2f2a9012-1d1e-425b-a70c-5105c08f5eb1/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa364c-353c-6d9a-b9f8-c1ad82d2fcfe", "datePublished": "2024-11-15T12:17:44-04:00", "title": "7-anexo-b-02-05-solumedicfirmado-67376618021f5.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/19746a4f-8923-4339-8395-c3f31c6f9005/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9c30a-abb4-6c4e-a2d3-ad50726822bd", "datePublished": "2024-11-06T08:17:10-04:00", "title": "contrato-form-n-166-2024-bioerix-s-a-lpn-n-21-2024-672b5036b69d7.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/243e808c-fbe6-4c42-98c4-1f2750df47f0/download", "language": "es", "documentType": "contractSigned", "documentTypeDetails": "Contrato"}, {"id": "1ef9d0cb-af32-6c8a-8f0e-9f04ec362f14", "datePublished": "2024-11-07T10:32:27-04:00", "title": "chat-equipos-672cc16b41e5c.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/fb416ecc-3ca5-4c5e-99ed-63f4ca6deb72/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0cc-3887-6594-ac41-c93ca644b59a", "datePublished": "2024-11-07T10:32:41-04:00", "title": "nota-dncp-lpn-21-2024-comp2-exp-672cc179451db.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/6c5c0c7a-ea0e-4020-bd71-0759c8338574/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa364a-8830-6080-8a85-1bb94f7ba5a5", "datePublished": "2024-11-15T12:16:59-04:00", "title": "1-nota-n-2502-2024-reparo-lpn-21-2024firmado-673765eb00177.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/a9b69b9b-09ff-4f74-b4b9-54099e935133/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa364c-6b53-6208-ab34-990a920346eb", "datePublished": "2024-11-15T12:17:49-04:00", "title": "8-anexo-b-02-17-argonfirmado-6737661dace89.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/775c10b7-acd1-4873-8e50-d4f8f0ad8f4d/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa364c-ff16-67d8-b9e6-43e3d90fb572", "datePublished": "2024-11-15T12:18:05-04:00", "title": "11-cpa-lpn-21-2024-comp2-6737662d219de.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/b5645adb-6408-4c87-a7ca-9f388cbec206/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0cb-7f04-6c7a-8bb2-df5281496e2d", "datePublished": "2024-11-07T10:32:22-04:00", "title": "expediente-de-mesa-de-entrada-dncp-n-13204-rv-nota-una-fcm-daf-dcp-n-2342-2024-672cc16630ee3.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/be268dd0-3fd7-4948-bdee-e322d322b8e7/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa364a-f3d4-64da-bf49-87f9d65de0c2", "datePublished": "2024-11-15T12:17:10-04:00", "title": "3-notificacion-de-adjudicacion-complementaria-n-2-673765f64df2a.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/4ad4ec14-3512-4e8e-abb8-03955971fc99/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa364b-bdda-6a18-beb3-f5656eecc63d", "datePublished": "2024-11-15T12:17:31-04:00", "title": "5-infor-eva-comp-02-lpn-21-24-6737660b33224.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/0e53db27-563a-471e-8c90-72df8b673be9/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa364c-007d-66b8-92eb-61a1e9ce4642", "datePublished": "2024-11-15T12:17:38-04:00", "title": "6-anexo-b-02-05-argonfirmado-673766127a479.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/d20db43e-0353-4812-a255-1dde3fce44fd/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa364c-d0fc-6802-be88-d9a1baa3fdb3", "datePublished": "2024-11-15T12:18:00-04:00", "title": "10-cco-lpn-21-2024-comp2-67376628544c1.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/270960ea-0a18-46bb-b1c2-c86337d2b0f4/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa364a-bdf7-6b00-a106-fb08ca639d4b", "datePublished": "2024-11-15T12:17:04-04:00", "title": "2-respuesta-sobre-el-expediente-13204-equipos-medicos-673765f0a24bf.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/cb59ce4d-b695-4ffa-a1b2-4992f35cbcc8/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0cb-2821-69bc-861f-dde8b45a1551", "datePublished": "2024-11-07T10:32:13-04:00", "title": "nota-n-2427-2024-reparo-lpn-21-2024firmado-672cc15d0314c.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbdd-ce68-682e-9cb6-832f507ce7a1/files/33f8aecf-aa62-41ef-9000-1c4ea52e2051/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}]}, {"id": "LP-28001-24-246511", "implementation": {"financialProgress": {"breakdown": [{"id": "2024/28/1/1/1/0/4/4/11/535/20/LP-28001-24-246511", "period": {"startDate": "2024-01-01T00:00:00Z", "endDate": "2024-12-31T00:00:00Z"}, "measures": {"monto_a_utilizar": 9600000000}, "classifications": {"anio": "2024", "nivel": "28", "entidad": "1", "tipo_programa": "1", "programa": "1", "sub_programa": "0", "proyecto": "4", "financiador": "4", "departamento": "11", "objeto_gasto": "535", "fuente_financiamiento": "20", "cdp": "1307"}, "financialCode": "LP-28001-24-246511"}]}, "transactions": [{"id": "SIAF+LP-28001-24-246511+001-001-0000676+4348295", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 88987360}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "SUMI SOCIEDAD ANONIMA", "id": "PY-RUC-80068800-7"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0000676", "bill": {"id": "001-001-0000676", "type": "FACTURA", "date": "2024-11-05T00:00:00-04:00", "amount": {"amount": 95480000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 3472000, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 333312, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 2604000, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246511"}, {"id": "SIAF+LP-28001-24-246511+001-001-0000796+4359057", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 355949440}, "date": "2024-12-27T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "SUMI SOCIEDAD ANONIMA", "id": "PY-RUC-80068800-7"}, "requestDate": "2024-12-23T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0000796", "bill": {"id": "001-001-0000796", "type": "FACTURA", "date": "2024-12-11T00:00:00-04:00", "amount": {"amount": 381920000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 13888000, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 1333248, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 10416000, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246511"}]}, "awardID": "1ef8bc9e-ca53-6df8-81d6-5539425ca473", "status": "active", "statusDetails": "publicado", "period": {"startDate": "2024-10-29T00:00:00-04:00"}, "value": {"amount": 477400000, "currency": "PYG"}, "documents": [{"id": "1efa3667-bf77-6ecc-bbae-11dbdc357f92", "datePublished": "2024-11-15T12:30:03-04:00", "title": "9-anexo-b-02-17-solumedicfirmado-673768fb48206.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/a6dc667f-a5e2-4a3c-84ee-5ec72612844b/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3666-42e6-62ba-bf4d-b3c6fb02ae4b", "datePublished": "2024-11-15T12:29:23-04:00", "title": "2-respuesta-sobre-el-expediente-13204-equipos-medicos-673768d35d868.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/4c8075cd-cfc9-4d71-b180-3f23b6d7e84b/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0da-a6ad-6e66-94dd-91d39cf64abd", "datePublished": "2024-11-07T10:39:09-04:00", "title": "chat-equipos-672cc2fd071d8.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/86691df0-2eb4-4d5f-b4ea-c944d50a9c93/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef95ef0-d05a-66c6-9a76-4f9787682cb4", "datePublished": "2024-10-29T09:12:21-04:00", "title": "cdp-lpn-n-21-2024-6720d125dbbb5.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/2fe724a0-737f-45c7-bce4-700ff1813a96/download", "language": "es", "documentTypeDetails": "CDP"}, {"id": "1ef95ef1-5a2e-6a64-a6f9-23d2f2479482", "datePublished": "2024-10-29T09:12:36-04:00", "title": "resol-d-n-182-adm-de-contratos-001-6720d13456f87.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/f47393ac-5ad7-4599-8920-31e3ddd120da/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa3668-23ff-617e-ab0e-19db72b220c2", "datePublished": "2024-11-15T12:30:13-04:00", "title": "11-cpa-lpn-21-2024-comp2-673769057e0bb.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/ec6fbcbb-1bd4-495d-a9e3-b2438ae4f25b/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0da-6d05-6664-ac05-db41138d89ca", "datePublished": "2024-11-07T10:39:03-04:00", "title": "expediente-de-mesa-de-entrada-dncp-n-13204-rv-nota-una-fcm-daf-dcp-n-2342-2024-672cc2f6f309b.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/db84fcd1-e54f-47db-9a97-eae25d8878ee/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3666-a2c7-6d64-80b1-3dabbaa6fa49", "datePublished": "2024-11-15T12:29:33-04:00", "title": "4-resol-d-n-1873-2024-eval-compl-n-02-lpn-n-21-024-673768dd66050.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/61e364a4-dcee-49c0-8f33-5b930642a3ef/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3666-0abd-6ffa-8972-6561015dd291", "datePublished": "2024-11-15T12:29:17-04:00", "title": "1-nota-n-2502-2024-reparo-lpn-21-2024firmado-673768cd74d68.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/abd332f8-28ec-4708-89d4-505336fb7899/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0da-38f9-6398-86d8-45044643843a", "datePublished": "2024-11-07T10:38:57-04:00", "title": "nota-n-2427-2024-reparo-lpn-21-2024firmado-672cc2f1767d0.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/122c4c20-e501-4d02-af05-e29431f46c62/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3667-5f06-67f0-83a3-ab50bafba5a1", "datePublished": "2024-11-15T12:29:53-04:00", "title": "7-anexo-b-02-05-solumedicfirmado-673768f12c46c.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/5fb1cc37-3a58-41b6-b3db-f3ca09baf5cd/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0db-1bd0-6e82-b730-eb7c0dad65e0", "datePublished": "2024-11-07T10:39:21-04:00", "title": "nota-dncp-lpn-21-2024-comp2-exp-672cc308d51f9.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/6d2d1dd9-21e9-4d18-891f-8e1d36882573/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3666-f265-63f8-ac88-1dbf79b74b2a", "datePublished": "2024-11-15T12:29:41-04:00", "title": "5-infor-eva-comp-02-lpn-21-24-673768e577598.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/d699e46f-c34b-4476-b798-c00bbd2ec6d9/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3667-917c-69aa-9f04-05bd1cc47d9e", "datePublished": "2024-11-15T12:29:58-04:00", "title": "8-anexo-b-02-17-argonfirmado-673768f6724fd.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/75a2dfee-5495-4fba-9d95-bfdca53b9896/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef95ef1-1a93-60bc-b4e3-49ef923c6833", "datePublished": "2024-10-29T09:12:29-04:00", "title": "notificacion-adjudicacion-lpn-n-21-2024-6720d12daa6eb.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/f12dd5f4-f418-4939-9a37-31c4fdcc4399/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa3667-2808-6f8c-a64e-b3c39d7651e3", "datePublished": "2024-11-15T12:29:47-04:00", "title": "6-anexo-b-02-05-argonfirmado-673768eb687ce.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/d06b32fa-7f43-4ba9-916a-bcd786fea48f/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3667-f4b7-69e8-9131-dfa8a7446a4f", "datePublished": "2024-11-15T12:30:08-04:00", "title": "10-cco-lpn-21-2024-comp2-67376900ccb94.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/79465156-54fd-410c-9b04-68f14b9575a6/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3666-72f2-62f6-8498-e5586e27455c", "datePublished": "2024-11-15T12:29:28-04:00", "title": "3-notificacion-de-adjudicacion-complementaria-n-2-673768d866f41.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/27ee2d59-850d-44f3-a5ae-05651dec2054/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef95ef0-4a53-6c80-b698-abf935a74268", "datePublished": "2024-10-29T09:12:07-04:00", "title": "contrato-form-n-172-2024-sumi-s-a-lpn-n-21-2024-6720d117d3f71.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bc9e-ca53-6df8-81d6-5539425ca473/files/d9c0ee12-384b-486e-8f27-ea6e3173e63f/download", "language": "es", "documentType": "contractSigned", "documentTypeDetails": "Contrato"}]}, {"id": "LP-28001-24-246509", "implementation": {"financialProgress": {"breakdown": [{"id": "2024/28/1/1/1/0/4/4/11/535/20/LP-28001-24-246509", "period": {"startDate": "2024-01-01T00:00:00Z", "endDate": "2024-12-31T00:00:00Z"}, "measures": {"monto_a_utilizar": 9600000000}, "classifications": {"anio": "2024", "nivel": "28", "entidad": "1", "tipo_programa": "1", "programa": "1", "sub_programa": "0", "proyecto": "4", "financiador": "4", "departamento": "11", "objeto_gasto": "535", "fuente_financiamiento": "20", "cdp": "1307"}, "financialCode": "LP-28001-24-246509"}]}, "transactions": [{"id": "SIAF+LP-28001-24-246509+001-004-0000203+4350560", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 205040000}, "date": "2024-12-05T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "SURVYCON S.A. SURVEY & CONTROL", "id": "PY-RUC-80063377-6"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-004-0000203", "bill": {"id": "001-004-0000203", "type": "FACTURA", "date": "2024-11-25T00:00:00-04:00", "amount": {"amount": 220000000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 8000000, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 768000, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 6000000, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246509"}]}, "awardID": "1ef8bca3-d665-62d6-bf3d-03e9b40e05cd", "status": "active", "statusDetails": "publicado", "period": {"startDate": "2024-11-06T00:00:00-04:00"}, "value": {"amount": 220000000, "currency": "PYG"}, "documents": [{"id": "1ef9c311-960d-697a-96d7-eba975a0ba46", "datePublished": "2024-11-06T08:20:16-04:00", "title": "resol-d-n-182-adm-de-contratos-001-672b50f060e9a.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/52cd0c06-556e-499f-b0a2-a68bf08e0320/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1ef9d0dc-f620-6eec-b405-45e8a95bec3b", "datePublished": "2024-11-07T10:40:11-04:00", "title": "chat-equipos-672cc33b08f6a.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/20efa5cf-22b4-4e8a-9f5d-62e75895f9a8/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9c310-b019-66bc-b0af-299b2a870e1f", "datePublished": "2024-11-06T08:19:52-04:00", "title": "contrato-form-n-173-2024-survycon-s-a-lpn-n-21-2024-672b50d83fd95.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/34ecdfe4-3607-4629-b6ec-2ead7ec84af0/download", "language": "es", "documentType": "contractSigned", "documentTypeDetails": "Contrato"}, {"id": "1ef9c311-4600-6c7a-aa1e-4f1a84239b05", "datePublished": "2024-11-06T08:20:08-04:00", "title": "cdp-lpn-n-21-2024-672b50e8088a0.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/0cdeb9f0-21ca-47b0-b235-22bb36273888/download", "language": "es", "documentTypeDetails": "CDP"}, {"id": "1efa366b-c345-6618-abc1-0b39e665cc9c", "datePublished": "2024-11-15T12:31:51-04:00", "title": "10-cco-lpn-21-2024-comp2-67376966b3600.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/f3dac4ae-422f-4d73-9a8f-760ff47fa402/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3669-c264-6606-990a-c9afb793be93", "datePublished": "2024-11-15T12:30:57-04:00", "title": "2-respuesta-sobre-el-expediente-13204-equipos-medicos-673769311b808.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/9f708982-6717-4138-8c49-26b1aa9cddb7/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa366a-e79e-6f38-843f-b59e5dcbca92", "datePublished": "2024-11-15T12:31:28-04:00", "title": "6-anexo-b-02-05-argonfirmado-6737694fa640d.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/1f6aad77-bcb6-4eda-985e-15f3345fd701/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa366b-1695-6a62-a757-c143d3cc5f3c", "datePublished": "2024-11-15T12:31:33-04:00", "title": "7-anexo-b-02-05-solumedicfirmado-6737695496c7d.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/2cf1c2f1-dc79-42c6-a85b-8cc879381ee2/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0dc-c8eb-613e-9635-2740379a9c74", "datePublished": "2024-11-07T10:40:06-04:00", "title": "expediente-de-mesa-de-entrada-dncp-n-13204-rv-nota-una-fcm-daf-dcp-n-2342-2024-672cc33649271.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/8a17ddc2-cafc-413a-8b05-6f2a2697bd74/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa366a-0a15-6496-8772-97784111ca93", "datePublished": "2024-11-15T12:31:04-04:00", "title": "3-notificacion-de-adjudicacion-complementaria-n-2-67376938ab010.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/16a62941-e073-4075-a910-de6e4b03a60e/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa366a-43b7-6e88-bb98-1b5ab0e8a4ef", "datePublished": "2024-11-15T12:31:10-04:00", "title": "4-resol-d-n-1873-2024-eval-compl-n-02-lpn-n-21-024-6737693eb0636.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/5d7e210b-c2a0-4bd7-99ed-e48fdac2cf7f/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa366b-4e06-6168-bbaf-f31288a1bbcd", "datePublished": "2024-11-15T12:31:38-04:00", "title": "8-anexo-b-02-17-argonfirmado-6737695a68062.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/4b321960-8cfd-4398-83c3-ff4cbaa4ac75/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3669-887d-6db6-ad8d-3f13b31bf452", "datePublished": "2024-11-15T12:30:51-04:00", "title": "1-nota-n-2502-2024-reparo-lpn-21-2024firmado-6737692b3337a.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/c0df5f74-9f3d-438e-a966-26e9ad7ef711/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0dc-902e-61f2-81be-bfbffcb5ba1b", "datePublished": "2024-11-07T10:40:00-04:00", "title": "nota-n-2427-2024-reparo-lpn-21-2024firmado-672cc330527b4.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/df634df8-669e-4d42-9787-d654bed4c43e/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa366b-85c1-6cd8-8a31-5f45674325bc", "datePublished": "2024-11-15T12:31:44-04:00", "title": "9-anexo-b-02-17-solumedicfirmado-6737696029431.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/ac5066f7-5281-48dd-8317-939592ebe014/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0dd-a707-6be8-9766-edb33c531d09", "datePublished": "2024-11-07T10:40:29-04:00", "title": "nota-dncp-lpn-21-2024-comp2-exp-672cc34d2e861.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/79f70e63-1371-499f-b092-c871573e8c11/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa366a-a5f3-6c3c-9927-33b4bad1157d", "datePublished": "2024-11-15T12:31:21-04:00", "title": "5-infor-eva-comp-02-lpn-21-24-6737694810988.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/fa6841cb-be95-4a18-869d-1c5b34886384/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa366b-f40b-684c-8362-2957907ca7e7", "datePublished": "2024-11-15T12:31:56-04:00", "title": "11-cpa-lpn-21-2024-comp2-6737696bafc72.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bca3-d665-62d6-bf3d-03e9b40e05cd/files/869fa48a-f991-4e10-bdcf-2628b3c969b7/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}]}, {"id": "LP-28001-24-246507", "implementation": {"financialProgress": {"breakdown": [{"id": "2024/28/1/1/1/0/4/4/11/535/20/LP-28001-24-246507", "period": {"startDate": "2024-01-01T00:00:00Z", "endDate": "2024-12-31T00:00:00Z"}, "measures": {"monto_a_utilizar": 9600000000}, "classifications": {"anio": "2024", "nivel": "28", "entidad": "1", "tipo_programa": "1", "programa": "1", "sub_programa": "0", "proyecto": "4", "financiador": "4", "departamento": "11", "objeto_gasto": "535", "fuente_financiamiento": "20", "cdp": "1307"}, "financialCode": "LP-28001-24-246507"}]}, "transactions": [{"id": "SIAF+LP-28001-24-246507+001-001-0002724+4347227", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 117503765}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "ALBATROS SACI", "id": "PY-RUC-80002766-3"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0002724", "bill": {"id": "001-001-0002724", "type": "FACTURA", "date": "2024-11-11T00:00:00-04:00", "amount": {"amount": 126077000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 4584618, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 440123, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 3438464, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246507"}, {"id": "SIAF+LP-28001-24-246507+001-001-0002725+4347228", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 131020560}, "date": "2024-12-03T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "ALBATROS SACI", "id": "PY-RUC-80002766-3"}, "requestDate": "2024-11-29T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0002725", "bill": {"id": "001-001-0002725", "type": "FACTURA", "date": "2024-11-11T00:00:00-04:00", "amount": {"amount": 140580000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 5112000, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 490752, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 3834000, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246507"}, {"id": "SIAF+LP-28001-24-246507+001-001-0002886+4358680", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 524082240}, "date": "2024-12-27T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "ALBATROS SACI", "id": "PY-RUC-80002766-3"}, "requestDate": "2024-12-23T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0002886", "bill": {"id": "001-001-0002886", "type": "FACTURA", "date": "2024-12-05T00:00:00-04:00", "amount": {"amount": 562320000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 20448000, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 1963008, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 15336000, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246507"}, {"id": "SIAF+LP-28001-24-246507+001-001-0002885+4358679", "sourceSystem": "SIAF", "value": {"currency": "PYG", "amount": 470015055}, "date": "2024-12-27T00:00:00-04:00", "payer": {"id": "DNCP-SICP-CODE-1360", "name": "Facultad de Ciencias Medicas / Universidad Nacional de Asunci\u00f3n"}, "payee": {"name": "ALBATROS SACI", "id": "PY-RUC-80002766-3"}, "requestDate": "2024-12-23T00:00:00-04:00", "finantialObligations": [{"id": "001-001-0002885", "bill": {"id": "001-001-0002885", "type": "FACTURA", "date": "2024-12-05T00:00:00-04:00", "amount": {"amount": 504308000, "currency": "PYG"}}, "retentions": [{"id": "1", "type": "tax", "name": "IVA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "2", "type": "tax", "name": "RENTA", "amount": {"amount": 18338473, "currency": "PYG"}}, {"id": "3", "type": "fee", "name": "MULTA", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "4", "type": "tax", "name": "RETENCION DNCP", "amount": {"amount": 1760493, "currency": "PYG"}}, {"id": "5", "type": "fee", "name": "ISC", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "6", "type": "fee", "name": "REPARO", "amount": {"amount": 0, "currency": "PYG"}}, {"id": "7", "type": "tax", "name": "RETENCION IVA", "amount": {"amount": 13753855, "currency": "PYG"}}]}], "financialCode": "LP-28001-24-246507"}]}, "awardID": "1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc", "status": "active", "statusDetails": "publicado", "period": {"startDate": "2024-11-06T00:00:00-04:00"}, "value": {"amount": 1333285000, "currency": "PYG"}, "documents": [{"id": "1efa3646-0aba-6fe6-beb1-07f052781fd4", "datePublished": "2024-11-15T12:14:58-04:00", "title": "4-resol-d-n-1873-2024-eval-compl-n-02-lpn-n-21-024-6737657272dea.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/dcf8f0dd-46ef-4c0b-ad9b-34bddf1265bb/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3646-e18c-63da-87f4-07211626e306", "datePublished": "2024-11-15T12:15:21-04:00", "title": "7-anexo-b-02-05-solumedicfirmado-673765890404e.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/dcfdb3c0-89bb-47c8-9cbd-cda2893067c9/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9c301-d743-627e-ab42-19be7b6ac21e", "datePublished": "2024-11-06T08:13:13-04:00", "title": "contrato-form-n-163-2024-albatros-saci-lpn-n-21-2024-672b4f49ae26e.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/ab53fc88-e46b-4c09-8feb-962466be8328/download", "language": "es", "documentType": "contractSigned", "documentTypeDetails": "Contrato"}, {"id": "1efa3647-53ec-6894-bad8-e3a4843a6ec0", "datePublished": "2024-11-15T12:15:33-04:00", "title": "9-anexo-b-02-17-solumedicfirmado-6737659504f82.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/987435fa-43e7-49fd-8ab6-2b0913aca6a2/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3645-9612-66ee-9c73-1fada1642dcc", "datePublished": "2024-11-15T12:14:46-04:00", "title": "2-respuesta-sobre-el-expediente-13204-equipos-medicos-673765663ffec.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/1904cb28-e740-43c8-bd06-a43ae19eee3f/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0c9-48a4-6632-816c-298737d9f9b1", "datePublished": "2024-11-07T10:31:22-04:00", "title": "nota-dncp-lpn-21-2024-comp2-exp-672cc12a61620.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/11266f0e-c621-4413-a2c4-92fc1a13e8bf/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3647-d873-6248-84a3-f97110af74ad", "datePublished": "2024-11-15T12:15:46-04:00", "title": "11-cpa-lpn-21-2024-comp2-673765a2e0a8d.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/3b28c6a6-5957-4ef5-b499-675d8deb87f4/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9c305-3397-60ea-8547-ffc63db4ca2e", "datePublished": "2024-11-06T08:14:44-04:00", "title": "cdp-lpn-n-21-2024-672b4fa3edd36.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/bd6d9d09-290c-4d2f-a6fe-9b8afc7577a4/download", "language": "es", "documentTypeDetails": "CDP"}, {"id": "1ef9c305-8493-62d2-bfb0-ffd4a2e34a4b", "datePublished": "2024-11-06T08:14:52-04:00", "title": "resol-d-n-182-adm-de-contratos-001-672b4fac6c460.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/95a30493-2cae-4d42-a1c1-227803759f26/download", "language": "es", "documentTypeDetails": "Nota de Comunicaci\u00f3n"}, {"id": "1efa3646-7c05-6ff2-b704-8b540fa32529", "datePublished": "2024-11-15T12:15:10-04:00", "title": "5-infor-eva-comp-02-lpn-21-24-6737657e150e9.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/6f6f2288-7693-42c9-8151-17461ecc5e6d/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0c7-da19-63bc-82e0-83feb124ab8e", "datePublished": "2024-11-07T10:30:44-04:00", "title": "expediente-de-mesa-de-entrada-dncp-n-13204-rv-nota-una-fcm-daf-dcp-n-2342-2024-672cc10460cd1.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/e5f482b6-8d49-4617-99e6-2e9a84478f3b/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0c8-34e2-66b8-bda9-71db67935219", "datePublished": "2024-11-07T10:30:53-04:00", "title": "chat-equipos-672cc10de1f0d.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/babacc22-48c8-40ac-8a85-e51a0cb0b3f8/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3646-b06f-64aa-bb03-cf22f64a097f", "datePublished": "2024-11-15T12:15:15-04:00", "title": "6-anexo-b-02-05-argonfirmado-67376583d4b3d.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/82c7e5b5-e400-45bd-875e-d84038eeee40/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3645-536c-63d0-b467-7dc99f083b8e", "datePublished": "2024-11-15T12:14:39-04:00", "title": "1-nota-n-2502-2024-reparo-lpn-21-2024firmado-6737655f44c84.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/617b7811-0be0-49c0-87e5-bf996214de35/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3645-d048-6110-91bc-0d76f3fa3ff0", "datePublished": "2024-11-15T12:14:52-04:00", "title": "3-notificacion-de-adjudicacion-complementaria-n-2-6737656bd3012.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/2d7e7715-7ed4-429a-9648-683b964bd3cd/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3647-942a-69c4-b3d4-03bf8d1c4837", "datePublished": "2024-11-15T12:15:39-04:00", "title": "10-cco-lpn-21-2024-comp2-6737659bb9eb5.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/db8056e0-aa9b-448c-ad30-7e0c785d1bea/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1ef9d0c5-b904-62f0-8d68-95d26ae10257", "datePublished": "2024-11-07T10:29:47-04:00", "title": "nota-n-2427-2024-reparo-lpn-21-2024firmado-672cc0cb35fa6.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/0020083d-10cb-4031-932a-18c7280a6dae/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}, {"id": "1efa3647-1b89-6826-87bf-29667e4ce2fe", "datePublished": "2024-11-15T12:15:27-04:00", "title": "8-anexo-b-02-17-argonfirmado-6737658f1d40d.pdf", "url": "https://www.contrataciones.gov.py/api/proveedor-adjudicado/1ef8bbb6-28a0-613e-a9c2-ab4e5a76d1bc/files/c7a02e45-a161-4fdf-99ed-3a6d4b3221a8/download", "language": "es", "documentTypeDetails": "Nota de Contestaci\u00f3n"}]}], "planning": {"identifier": "443857", "estimatedDate": "2024-08-31T00:00:00-04:00", "budget": {"description": "ADQUISICI\u00d3N DE EQUIPOS M\u00c9DICOS PARA LA FACULTAD DE CIENCIAS M\u00c9DICAS Y EL HOSPITAL DE CL\u00cdNICAS", "amount": {"currency": "PYG", "amount": 13086024147}, "budgetBreakdown": [{"id": "2024/28/1/1/1/0/4/4/11/535/20-sVmQiJ96e8M=", "sourceParty": {"id": "226", "name": "Universidad Nacional de Asunci\u00f3n"}, "period": {"startDate": "2024-01-01T00:00:00Z", "endDate": "2024-12-31T00:00:00Z"}, "measures": {"monto_utilizado": 11633928047, "monto_a_utilizar": 11633928047}, "classifications": {"anio": "2024", "nivel": "28", "entidad": "1", "tipo_programa": "1", "programa": "1", "sub_programa": "0", "proyecto": "4", "financiador": "4", "departamento": "11", "objeto_gasto": "535", "fuente_financiamiento": "20", "cdp": "1307"}}, {"id": "2024/28/1/1/1/0/4/1/11/535/10-ZRsV+cWVSWo=", "sourceParty": {"id": "226", "name": "Universidad Nacional de Asunci\u00f3n"}, "period": {"startDate": "2024-01-01T00:00:00Z", "endDate": "2024-12-31T00:00:00Z"}, "measures": {"monto_utilizado": 1452096100, "monto_a_utilizar": 1452096100}, "classifications": {"anio": "2024", "nivel": "28", "entidad": "1", "tipo_programa": "1", "programa": "1", "sub_programa": "0", "proyecto": "4", "financiador": "1", "departamento": "11", "objeto_gasto": "535", "fuente_financiamiento": "10", "cdp": "1307"}}]}, "items": [{"id": "1eee5df6-86aa-6fc2-8aeb-81baea6255d5", "description": "Suministros de intubacion", "classification": {"scheme": "UNSPSC", "id": "42272000", "description": "Suministros de intubacion", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42272000"}}, {"id": "1eee5df8-da51-61c4-9bd0-3d2bac0f689e", "description": "Estufas de laboratorio y accesorios", "classification": {"scheme": "UNSPSC", "id": "41104500", "description": "Estufas de laboratorio y accesorios", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/41104500"}}, {"id": "1eee5df7-a870-6dd6-90cf-ed8a3e646379", "description": "Instrumentos y accesorios de vision y observacion", "classification": {"scheme": "UNSPSC", "id": "41111700", "description": "Instrumentos y accesorios de vision y observacion", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/41111700"}}, {"id": "1eee5df4-90fc-6090-9a13-452c00779c9d", "description": "Productos para transporte de paciente", "classification": {"scheme": "UNSPSC", "id": "42192200", "description": "Productos para transporte de paciente", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42192200"}}, {"id": "1eee5df8-535b-6ac0-9151-6fbc49798bfd", "description": "Separadores", "classification": {"scheme": "UNSPSC", "id": "40161700", "description": "Separadores", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/40161700"}}, {"id": "1eee5df4-0676-6ae2-8d9c-c54e1d16e6d4", "description": "Unidades de control de cuidado intenso y productos relacionados", "classification": {"scheme": "UNSPSC", "id": "42181900", "description": "Unidades de control de cuidado intenso y productos relacionados", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181900"}}, {"id": "1eee5df5-e753-6e4c-b6bc-e34e1cf34489", "description": "Productos para la gestion de la via aerea", "classification": {"scheme": "UNSPSC", "id": "42271900", "description": "Productos para la gestion de la via aerea", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42271900"}}, {"id": "1eee5df3-6e6c-62ba-a24d-85944dc756cd", "description": "Unidades de electrocardiografia (ECG) y productos relacionados", "classification": {"scheme": "UNSPSC", "id": "42181700", "description": "Unidades de electrocardiografia (ECG) y productos relacionados", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181700"}}, {"id": "1eee5df2-cb15-6f76-9955-cd38bf1c1b9e", "description": "Evaluacion diagnostica y productos de examen de uso general", "classification": {"scheme": "UNSPSC", "id": "42181500", "description": "Evaluacion diagnostica y productos de examen de uso general", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42181500"}}, {"id": "1eee5df5-3661-6ed6-9826-ff1a0c816e2d", "description": "Productos de hacer imagenes de ultrasonido medico y de doppler y de eco", "classification": {"scheme": "UNSPSC", "id": "42201700", "description": "Productos de hacer imagenes de ultrasonido medico y de doppler y de eco", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42201700"}}, {"id": "1eee5df7-0dd5-68c6-b894-c78234a93f71", "description": "Endoscopios y accesorios y productos relacionados", "classification": {"scheme": "UNSPSC", "id": "42294800", "description": "Endoscopios y accesorios y productos relacionados", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42294800"}}, {"id": "1eee5df2-374f-6936-af9a-9732208f5c96", "description": "Productos de sacar, inmovilizar y trasladar de servicios medicos de urgencia", "classification": {"scheme": "UNSPSC", "id": "42171600", "description": "Productos de sacar, inmovilizar y trasladar de servicios medicos de urgencia", "uri": "https://www.contrataciones.gov.py/datos/api/v3/doc/itemClassification/n4/42171600"}}]}, "tag": ["compiled"]}}], "pagination": {"total_items": 1, "total_pages": 1, "current_page": 1, "items_per_page": 10, "total_in_page": 1}}
